UC series – compact stand-alone I/O modules with USB, Ethernet, CAN, and CANopen
The UC series is particularly suitable for small to medium-sized applications where a compact, ready-to-use stand-alone I/O module is required and no extensively expandable modular system architecture is needed. The modules are generally operated as stand-alone units. Versions with a USB interface and UC-CANopen modules can also be connected to one another via an optional In-Rail connector. UC versions with an Ethernet interface do not support In-Rail connection.
On this page
- The UC series at a glance
- Which applications is the UC series suitable for?
- When is the UC series the right choice?
- USB, Ethernet, CAN, or CANopen – which UC interface
is right? - Digital, analog, and temperature I/Os of the UC series
- How to select the right UC module
- Select UC modules by function
- Control the UC series and integrate it into your own
software - More than simple I/O – additional functions of the UC
series - The UC series in practice
- UC, NET, RO, or BS – which DEDITEC I/O series
is right? - Development, long-term availability, and
technical support - Frequently asked questions about the UC series
- Find the right UC module for your application
The UC series at a glance
| Feature | Benefit |
|---|---|
| Compact stand-alone I/O modules | For small to medium-sized measurement, control, and automation tasks without an extensive modular system architecture. |
| USB, Ethernet, CAN, or CANopen | The appropriate communication interface can be selected depending on the application. |
| Digital and analog I/Os | Different input and output signals can be acquired or output according to the requirements of the respective application. |
| Temperature measurement | Variants for temperature measurement with thermocouples extend the range of applications. |
| DIN rail mounting | Compact integration into control cabinets and technical installations. |
| Optional In-Rail connection | For UC modules with a USB interface and for UC-CANopen, the CAN bus and power supply can be passed between multiple modules via the In-Rail connector. Versions with an Ethernet interface do not support In-Rail connection. |
| DELIB/API and ICT-Tool | Integration into your own software as well as configuration, functional testing, and diagnostics. |
| Various I/O versions | Selection based on channel count, signal type, resolution, and electrical requirements. |
Which applications is the UC series suitable for?
The UC series is particularly suitable for compact measurement, control, and automation tasks where a stand-alone I/O module is to be connected directly to a control PC, network, or CAN system. With different variants for digital, analog, and temperature-related signals, the appropriate module can be selected according to the requirements of the respective application.
PC-based measurement and control systems
Small-scale automation projects
Acquire and output analog signals
The UC series offers different variants for analog voltage and current signals. These can be used to acquire measured values or output analog setpoint and control signals. Depending on the module, different channel counts, measurement ranges, and resolutions are available.
Digital control and switching tasks
For digital I/O applications, UC variants with optocoupler-isolated inputs and relay or MOSFET outputs are available. This allows digital signal states to be acquired and corresponding switching and control functions to be implemented.
Temperature measurement
For temperature measurement applications, UC variants with four thermocouple inputs for Type K sensors are available. This allows the UC series to be used for compact temperature acquisition and monitoring tasks.
CAN- and CANopen-based automation tasks
For CAN-based applications, UC-CAN variants are available. Supported communication modes include RAW CAN, SAE J1939, and the DEDITEC DELIB command mode. A separate UC-CANopen product family is available for standardized CANopen systems.
Other typical application areas for the UC series include test benches and test systems, laboratory and R&D applications, machine and plant control, measurement data acquisition, process monitoring and quality assurance, as well as PC-, CAN-, or CANopen-based automation systems.
When is the UC series the right choice?
The UC series is particularly suitable when a compact stand-alone I/O module is required for a small to medium-sized measurement, control, or automation task. Instead of implementing a larger modular I/O system, a suitable UC variant can be selected directly with the required inputs and outputs as well as the appropriate communication interface for the application.
- a compact stand-alone I/O module for DIN rail mounting is required,
- only a manageable number of defined inputs and outputs is needed,
- USB, Ethernet, CAN, or CANopen is required as the communication interface,
- digital or analog signals need to be acquired or output,
- temperature measurement is part of the application,
- the module is to be integrated directly into a custom PC or software application,
- no extensively expandable modular I/O architecture, such as the NET series, is required.
UC series or NET series?
The I/O configuration is predefined by the respective module variant and cannot subsequently be expanded by adding further I/O modules. The UC series is therefore particularly suited to applications where the required I/O configuration is already largely defined.
| If You Need … | More Suitable |
|---|---|
| Compact stand-alone I/O module | UC series |
| Small to medium-sized measurement or control task | UC series |
| Predefined I/O configuration | UC series |
| Modularly expandable I/O system | NET series |
| Multiple different I/O types within one system | NET series |
| Higher channel counts or future expansion | NET series |
Stand-alone – but expandable when required
UC variants with an Ethernet interface, however, do not support In-Rail connection. This applies both to UC-ETH modules and to UC-CAN variants with an additional Ethernet interface.
| UC variant | In-Rail connection |
|---|---|
| UC-USB | Yes |
| UC-ETH | No |
| UC-CAN with USB interface | Yes |
| UC-CAN with Ethernet interface | No |
| UC-CANopen | Yes |
When is the UC series less suitable?
- a large number of different I/O types need to be combined within a single modular system,
- an extensive I/O architecture with future modular expansion is planned from the outset,
- higher channel counts are required within a centrally structured I/O architecture.
In these cases, it should be evaluated whether the modular NET series is better suited to the application.
USB, Ethernet, CAN, or CANopen – which UC interface is right?
CAN and CANopen should not be treated as equivalent. The standard UC-CAN modules support communication modes including RAW CAN and SAE J1939.
The UC-CANopen series is a separate product family designed specifically for CANopen-based systems.
| Variant | Communication | Particularly suitable when … |
|---|---|---|
| UC-USB | USB | the I/O module is to be connected locally and directly to a PC. |
| UC-ETH | Ethernet / WiFi / TCP/IP | the module needs to be accessible via a network or Modbus TCP is to be used. |
| UC-CAN | CAN | the module is to be integrated into an existing CAN application or RAW CAN or SAE J1939 communication is required. |
| UC-CANopen | CANopen | standardized CANopen integration based on CiA profiles is required. |
UC-USB – direct connection to the control PC
UC-ETH – I/O via Ethernet, WiFi, and Modbus TCP
Some variants in the series additionally feature a WPS button for convenient WiFi setup. Alternatively, the WiFi configuration can be performed using the ICT-Tool.
UC-CAN – RAW CAN, SAE J1939, and automatic TX/RX functions
Depending on the variant, UC-CAN modules are additionally equipped with USB or Ethernet as a configuration interface. With UC-CAN, CAN remains the primary functional interface, while the additional interface is used for configuration. The additional interface also determines whether an In-Rail connection is supported: UC-CAN variants with a USB interface support the In-Rail connector, whereas variants with an Ethernet interface do not.
UC-CANopen – for standardized CANopen systems
Which interface should I choose?
- Choose USB if the module is to be operated locally and connected directly to a PC.
- Choose Ethernet/WiFi if the module needs to be accessible via a LAN or WiFi network or if Modbus TCP is required.
- Choose CAN if RAW CAN, SAE J1939, or project-specific CAN communication is required.
- Choose CANopen if the module is to be integrated as a CANopen I/O device into an existing CANopen network.
Digital, analog, and temperature I/Os of the UC series
The UC series offers different I/O variants for digital, analog, and temperature-related measurement and control tasks. Depending on the application, a module can be selected based on the required signal type, channel count, resolution, and electrical requirements.
| Category | Typical UC variants | Application |
|---|---|---|
| Analog inputs | AD2-16/18 ISO, AD16-16/18 | Acquisition of voltage and current signals |
| Analog outputs | DA2-16 ISO, DA4-16, DA8-16 | Output of analog setpoint and control signals |
| Digital inputs | OPTOIN / O16 | Acquisition of digital signal states |
| Relay outputs | R16_3A, O8-R8_3A | Potential-free relay-based switching tasks |
| MOSFET outputs | M16, O8-M8 | Electronic switching tasks |
| Temperature | THERMO4_K | Temperature measurement using Type K thermocouples |
| Combined digital I/Os | O8-R8 / O8-M8 | Digital inputs and outputs within a single module |
Analog inputs for voltage and current signals
For the acquisition of analog signals, UC modules with different channel counts and resolutions are available. Depending on the variant, voltage or current signals can be processed. Versions with galvanically isolated inputs are also available.
Analog outputs for setpoint and control signals
For the output of analog signals, UC modules with 2, 4, or 8 output channels are available. Depending on the module, the variants can be used for voltage signals and, where supported, also for current signals.
Digital inputs with optocouplers
For the acquisition of digital signal states, UC variants with optocoupler-isolated inputs are available. These are suitable for reliably detecting binary input signals and forwarding them to the higher-level control or software application.
Relay and MOSFET outputs
For switching applications, UC variants with relay or MOSFET outputs are available. The relay variants of the UC Series feature potential-free relay outputs. Depending on the application, this allows a choice between relay-based and electronic output stages.
Temperature measurement with thermocouples
For temperature measurement applications, the UC series offers variants with four inputs for Type K thermocouples. This makes the UC series suitable for compact temperature acquisition tasks.
Combined digital inputs and outputs
For applications that require both the acquisition of digital signal states and the switching of outputs, combined UC variants are available, for example with eight digital inputs and eight relay or MOSFET outputs.
Which I/O type is right?
- Choose analog inputs when voltage, current, or sensor signals need to be measured.
- Choose analog outputs when setpoints or analog control signals need to be generated.
- Choose digital inputs when switching states or binary signals need to be acquired.
- Choose relay outputs when electrical loads need to be switched using conventional relay contacts.
- Choose MOSFET outputs when electronic switching functions are required.
- Choose temperature modules when thermocouple signals need to be acquired directly.
- Choose combined I/O modules when digital inputs and outputs are required within a compact stand-alone module.
How to select the right UC module
Which UC module is suitable for an application primarily depends on five factors: communication interface, required I/O type, channel count, electrical signal type, and the desired software or protocol integration.
1. Define the communication interface
USB is suitable for a direct local connection to a PC. Ethernet enables integration via a network and, for the corresponding variants, also supports Modbus TCP. CAN is intended for applications using RAW CAN, SAE J1939, or the DEDITEC communication mode. CANopen is the appropriate variant for integration into CANopen-based systems.
2. Determine the required I/O type
Next, determine whether digital inputs, relay or MOSFET outputs, analog inputs or outputs, temperature inputs, or combined digital I/Os are required.
3. Select the channel count and resolution
Depending on the variant, analog input modules are available with, for example, 2 or 16 channels. Analog output variants are available with 2, 4, or 8 channels. For analog inputs, the required resolution must also be taken into account.
4. Check voltage, current, and switching requirements
For analog modules, the required voltage or current ranges must be determined. For digital outputs, the output technology and electrical load capacity must be suitable for the application.
5. Consider Software and Protocol Integration
For standard UC variants, DELIB, open DEDITEC protocols, and the ICT-Tool are available, among other options. Ethernet variants additionally support Modbus TCP; UC-CAN supports communication modes including RAW CAN and SAE J1939, while UC-CANopen provides standardized CANopen communication.
| Question | Selection criterion |
|---|---|
| How should the module communicate? | USB, Ethernet, CAN, or CANopen |
| Which signal types are required? | Digital, analog, or temperature |
| How many channels are required? | e.g. 2, 4, 8, or 16 channels |
| Which electrical signal type is used? | Voltage, current, relay, MOSFET |
| Which software/protocol interface is required? | DELIB, Modbus TCP, RAW CAN, J1939, or CANopen |
How is the right UC module selected?
Select UC modules by function
Analog inputs
Analog outputs
Relay outputs
MOSFET outputs
Digital inputs
Digital inputs/outputs
Temperature
Control the UC series and integrate it into your own software
| Control method / tool | Suitable for | Practical benefit |
|---|---|---|
| DELIB driver library / API | Custom PC and software applications | Consistent integration of UC hardware into custom applications |
| Open DEDITEC protocol | Custom or low-level hardware integration | Direct communication without DELIB via open protocols |
| Modbus TCP | Ethernet-based control and automation systems | Standardized access to I/O data via registers and bits |
| DELIB CLI | Scripts, testing, and automated processes | Command-line control |
| ICT-Tool | Commissioning, configuration, and diagnostics | Configure, test, diagnose, and update module firmware |
| RAW CAN / J1939 | CAN-based applications | Integration into corresponding CAN communication architectures |
| CANopen | CANopen-based systems | Standardized integration of UC-CANopen modules |
Custom applications with DELIB and API
For integration into custom applications, DELIB supports various programming languages and development environments, including C/C++, C#, Delphi, Visual Basic, Java, LabVIEW, and Python. For Python, DEDITEC provides the files delib.py and delib.dll, which can be integrated into the respective customer project. This makes the DELIB commands available in Python as well. For standard UC variants, the API provides access to the required I/O and communication functions.
Command-line control with DELIB CLI
With the DELIB CLI, UC-USB and UC-Ethernet modules can also be accessed via the command line. This is suitable, for example, for scripts, testing, and automated processes under Windows and Linux.
How can the UC Series be integrated into custom software?
Standard UC variants can be integrated into custom applications using the DEDITEC DELIB or, where supported by the respective interface, accessed directly via the open DEDITEC communication protocols. Ethernet variants additionally support Modbus TCP. The ICT-Tool is available for testing, configuration, and diagnostics. UC-CANopen is integrated separately into existing systems via CANopen.
Open DEDITEC protocol
For custom integrations, UC modules with the corresponding interfaces can also be accessed directly via the open DEDITEC communication protocols. This allows the hardware to be integrated into custom systems and applications independently of DELIB.
Commissioning and diagnostics with the ICT-Tool
With the ICT-Tool, UC modules can be configured, tested, and diagnosed without first having to develop a custom application. Firmware updates can also be transferred directly to the modules.
Modbus TCP for Ethernet variants
UC-Ethernet modules can also be accessed via Modbus TCP. This allows the I/Os to be integrated into suitably equipped control and automation systems using a standardized TCP/IP-based protocol.
Consider UC-CANopen separately
UC-CANopen is not controlled via DELIB but uses standardized CANopen communication. For this reason, UC-CANopen is treated separately from standard UC-CAN modules with regard to software and protocol integration.
More than simple I/O – additional functions of the UC series
| Function | Benefit |
|---|---|
| Event Control | Automatic actions based on defined input states or measured values |
| Timeout / watchdog function | For UC modules with digital or analog outputs: automatically switch off outputs if communication is interrupted |
| Digital input filters | Suppress short interference pulses |
| State change detection | Detect changes at digital inputs between two polling cycles |
| Input counters | Count events at digital inputs |
| CAN Auto TX/RX | Automatically transmit and receive CAN messages |
| M2M communication | Direct data exchange between compatible modules |
| Testing and diagnostics | Verify I/Os, communication, and access times |
Event Control for Local Responses
Example: If an analog input exceeds a defined threshold, the UC module can automatically switch an output, depending on its configuration, without requiring the response to be triggered continuously by the PC application.
Timeout / watchdog function for output modules
Digital input filters and state change detection
Digital input counters
Automatic transmission and reception of CAN messages
M2M – direct communication between modules
Testing and diagnostic options
For commissioning and troubleshooting, the ICT-Tool provides various testing and diagnostic functions. Digital and analog I/Os can be tested, signal paths can be verified using loopback tests, and access times can be measured. Additional graphical diagnostic functions are available for analog inputs.
| Diagnostic function | Benefit |
|---|---|
| Digital cable loopback test | Check wiring and digital signal paths |
| Analog cable loopback test | Check analog signal paths |
| Modbus I/O test | Test Modbus TCP communication and I/Os |
| Access time test | Determine minimum, maximum, and average access times |
| Input counters | Count events at digital inputs |
| A/D noise visualization | Graphically evaluate the behavior of an analog input signal |
Which additional functions does the UC Series offer?
In addition to digital, analog, and temperature-related I/O functions, the UC Series offers features such as Event Control, timeout functions, digital input filters, state change detection, and input counters, depending on the module configuration. UC-CAN variants also support automatic CAN TX/RX functions. For commissioning and troubleshooting, the ICT-Tool provides a comprehensive range of testing and diagnostic functions.
UC series in practice
PC-based measurement systems
Analog or digital measurement values can be acquired using a UC module and transferred to a PC application. Depending on the variant, communication takes place via USB, Ethernet, or CAN. For custom applications, the I/O functions can be integrated using the corresponding software and communication interfaces.
Compact automation and control tasks
Analog measurement and control tasks
Acquire digital states and switch outputs
Temperature measurement in compact test setups
CAN-based measurement and control tasks
Support for SAE J1939 should not be understood as a specific automotive positioning. UC-CAN modules are primarily designed for industrial applications, for example in control cabinet and plant engineering.
CANopen-based automation
What is the UC series used for?
UC, NET, RO, or BS – which DEDITEC I/O series is right?
| Requirement | Suitable series |
|---|---|
| Compact stand-alone I/O module | UC series |
| Small to medium-sized measurement and control task | UC series |
| USB, Ethernet, CAN, or CANopen as a compact I/O solution | UC series |
| Build a modular system and expand it later | NET series |
| Combine many different I/O types within one system | NET series |
| Higher channel counts and more complex I/O structures | NET series |
| Very low installation depth | RO series |
| Custom I/O configurations and special functions in a low-profile design | RO series |
| High I/O channel counts in a compact aluminum enclosure | RO series |
| No future modular expansion required | UC, RO, or BS series – depending on I/O requirements and form factor |
UC series – compact stand-alone I/O modules
NET series – modularly expandable I/O system
RO series – when low installation depth is critical
BS series – many I/Os in a compact enclosure
UC or NET – the key difference
| UC series | NET series |
|---|---|
| Compact stand-alone module | Modular I/O system |
| For defined I/O tasks | For flexibly configurable I/O structures |
| Small to medium-sized applications | Larger or more complex systems |
| Selection of a suitable module | Combination of CPU and I/O modules |
| No modular expansion required | Expandability is a core element of the system |
What is the difference between the UC and NET series?
The UC series consists of compact stand-alone I/O modules for small to medium-sized measurement, control, and automation tasks. The NET series, by contrast, is designed as a modularly expandable I/O system and is particularly suitable when different I/O types, higher channel counts, or future expansions are required.
Which criteria are important when selecting the appropriate I/O series?
1. How many inputs and outputs are required?
2. Which signal types need to be processed?
3. Which communication interface is required?
4. Does the system need to support modular expansion at a later stage?
5. What are the requirements regarding form factor and installation space?
In simplified terms: Compact and stand-alone → UC | Modular and expandable → NET | Particularly low-profile → RO | Many I/Os in an aluminum enclosure → BS.
Development, long-term availability and technical support
| Benefit | Description |
|---|---|
| Made in Germany | Development and manufacturing in Germany |
| 10 years of long-term availability | For long-term projects and future reordering |
| Technical support | Support with selection, commissioning and integration |
| Software & documentation | DELIB/API, sample code, ICT-Tool and open communication protocols |
Made in Germany
The UC series is developed and manufactured by DEDITEC in Germany. This keeps development, production and technical support closely integrated.
Software, documentation and sample code
Software tools, API functions and sample programs are available for integrating the UC series. DELIB can be used to integrate standard UC variants into custom applications; the ICT-Tool and open communication protocols are also available for the corresponding interfaces.
What advantages does DEDITEC offer for long-term use of the UC series?
The UC series is developed and manufactured in Germany. DEDITEC offers 10 years of long-term availability for the series and provides support with selection, commissioning and software integration. DELIB/API, sample code, the ICT-Tool and open communication protocols are available for integration.
10 years of long-term availability
DEDITEC offers 10 years of long-term availability for the UC series. This also supports long-term projects in which replacement modules or reordering may be required over an extended period.
The modular product development approach supports this long-term strategy, as individual assemblies can be adapted more selectively when component availability changes.
Custom software and firmware adaptations
As with the other DEDITEC series, custom software and firmware adaptations can also be implemented for the UC series if the standard functions are not sufficient for a specific application.
Technical support with selection and integration
DEDITEC provides support in selecting the appropriate UC module as well as with questions relating to the interface, I/O variant, commissioning and software integration. For specific requirements, custom software and firmware adaptations are also available.
Open communication protocols
For UC products with the corresponding interfaces, DEDITEC provides open communication protocols. This allows the modules to be integrated directly into project-specific applications without using DELIB.
Frequently asked questions about the UC series
What is the DEDITEC UC series?
What does “stand-alone” mean for the UC series?
Which interfaces are available for the UC series?
What is the difference between the UC and NET series?
Which digital and analog I/Os are available for the UC series?
Does the UC series support Modbus TCP?
Can the UC series be integrated into custom software?
Can a UC module be commissioned without custom programming?
What is the difference between UC-CAN and UC-CANopen?
Can the UC series automatically respond to input signals?
What happens if communication is interrupted?
Can multiple UC modules be connected together?
How long are products in the UC series available?
Find the right UC module for your application
If you need support in selecting the appropriate module or with software integration, DEDITEC can assist with the technical selection and integration.
Select UC products
Support with selection
Are you unsure which UC module is right?
Helpful information for your inquiry:
- preferred interface, e.g. USB, Ethernet, CAN or CANopen,
- number and type of required I/Os,
- voltage and/or current ranges,
- loads to be switched,
- software or programming language used,
- required communication protocol or special functions such as Event Control or
Modbus TCP.
Install the installation program and check the module functions.