UC-CAN 16/18-bit A/D converter with galvanic isolation – 2 channels
The UC-CAN A/D module offers two galvanically isolated 16/18-bit inputs for precise measurement of voltages and currents via an open CAN interface. Ideal for industrial applications and test benches, e.g., for acquiring sensor signals or monitoring process variables. Thanks to its Auto RX/TX mode and robust design, the module is perfectly suited for reliable measurement tasks in CAN-based systems.
Price range: € 704,48 through € 723,35 Incl. 19% VAT plus shipping
Our promise to you
Product Description – industry test bench module with CAN and galvanic isolation
The UC-CAN A/D converter module was specifically developed for precise measurement tasks in industrial CAN networks. With two galvanically isolated 16/18-bit analog inputs, it enables high-resolution measurement of voltages and currents—even in noisy environments. The galvanic isolation reliably protects connected systems from potential differences and ensures maximum operational safety.
The industry test bench module with CAN and galvanic isolation supports flexible CAN communication with an adjustable baud rate and offers an automatic RX/TX mode that facilitates integration into existing measurement and control architectures. Thanks to robust electronics, an industrial-grade design, and precise signal processing, the device is ideally suited for demanding applications such as test benches, sensor data acquisition, or process monitoring.
Thanks to its compact design, the UC-CAN-AD2-16ISO can be easily integrated into distributed measurement systems. The high resolution enables precise analysis of even the smallest signal changes—a decisive advantage for industrial automation, quality assurance, and research. With its reliable performance, clearly structured CAN parameterization, and durable hardware, the UC-CAN A/D module offers a professional solution for precise measurement tasks in modern CAN-based systems.
CAN interface with flexible USB configuration
The CAN interface of the UC-CAN-AD2-16ISO is based on the CAN 2.0A/B standard and enables robust, error-resistant communication in industrial networks. It supports the typical multi-master CAN bus architecture, allowing multiple nodes to efficiently exchange data without a central controller. The bit rate is flexibly configurable, enabling the industry test bench module with CAN and galvanic isolation to be easily adapted to different network speeds and system environments. Communication is handled via standardized CAN telegrams with event-driven data transmission for fast and reliable signal processing.
The entire CAN configuration, including TX/RX behavior, is conveniently carried out via the integrated USB interface on a PC. This allows parameters such as bus speed and message handling to be quickly configured and tested. This combination of CAN and USB connectivity significantly simplifies commissioning and reduces integration and diagnostic effort.
Flexible CAN control via auto TX/RX and DELIB command mode
The control of the UC-CAN-AD2-16ISO is generally based on two operating modes: the Auto TX/RX mode and the DELIB command mode. In Auto TX/RX mode, the module can automatically send and receive CAN messages without the need for a continuously connected control PC.
Alternatively, the DELIB command mode provides direct register-based access via a proprietary CAN protocol, where specific commands are transmitted to the industry test bench module with CAN and galvanic isolation. Read and write operations are implemented using defined CAN IDs and structured data packets, enabling highly flexible and precise control.
Configuration of these operating modes is conveniently performed, depending on the product variant, via the integrated USB or Ethernet interface on a PC. Using the corresponding tool, parameters such as communication behavior, TX/RX logic, and DELIB command structure can be easily set up and tested. This allows the industry test bench module with CAN and galvanic isolation to be quickly adapted to different applications and efficiently integrated into existing CAN systems.
Accurate and interference-resistant analog signal acquisition for industrial applications
The analog inputs of the UC-CAN-AD2-16ISO are designed for precise acquisition of voltage and current signals in industrial applications and provide two independently usable measurement channels. They support common input signals such as ±40 V as well as current signals in the ranges 0–20 mA, 4–20 mA, and 0–24 mA, enabling flexible adaptation to various sensors. The inputs on the industry test bench module with CAN and galvanic isolation are implemented with high impedance, ensuring that connected signal sources are only minimally loaded and stable measurement values are guaranteed. Due to the high resolution of the conversion, even small signal changes are reliably detected and accurately represented. In addition, galvanic isolation of the input stages provides safe decoupling between the measurement system and the signal source, effectively reducing interference and potential differences. As a result, the analog inputs are particularly well suited for demanding measurement and monitoring tasks in industrial environments.
Event Control – event-based automation
The Event Control function enables direct, event-driven processing of both digital and analog signals in the industry test bench module with CAN and galvanic isolation, without requiring cyclic polling by higher-level software. Digital signal transitions can immediately trigger internal actions, while analog signals can generate events based on defined thresholds, measurement ranges, or significant value changes. This allows responses to be implemented much faster and more resource-efficiently compared to traditional polling-based processing.
The event logic can be flexibly configured, enabling both simple switching conditions and more complex dependencies between digital and analog signals. In addition, functions such as filtering, hysteresis, and threshold monitoring are available to ensure stable and reliable trigger conditions.
As a result, Event Control is particularly well suited for automation applications where signals must be evaluated intelligently and processed immediately.
M2M communication – direct device-to-device networking
The M2M (machine-to-machine) function enables direct communication between multiple modules or systems without a central control unit. States and events can be automatically exchanged and synchronized between devices, allowing the creation of distributed and autonomously operating automation structures. Communication is carried out via defined protocols and can be flexibly integrated into existing system architectures. As a result, M2M is particularly well suited for connected industrial and IoT applications.
Robust industrial design with a well-engineered connection and mounting architecture
The industry test bench module with CAN and galvanic isolation is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-CAN-AD2-16ISO, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm². In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.
Application and Benefits
The UC-CAN-AD2-16ISO offers a reliable and long-term solution for industrial automation tasks. With stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated and efficiently maintained. The robust electronics, developed in Germany and featuring galvanic isolation, ensure high operational reliability, while direct developer support and regular updates guarantee sustainable use in professional environments.
Technical Specifications
The UC-CAN A/D module offers two analog inputs with 16- or 18-bit resolution for precise measurement of voltages and currents. Electrical isolation up to 1 kV ensures a high level of safety in industrial applications. Flexible ranges such as 0–10 V or 4–20 mA make the module ideal for sensor applications and test benches. Using the open CAN protocol, it integrates reliably into existing systems and delivers stable measurement data.
Ethernet interface:
- Ethernet 10/100 Mbps
- Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP
- Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP
- Encrypted Ethernet communication possible
- Open standard or Modbus TCP protocol
- Web interface and app (smartphone and tablet)
- Electrically isolated up to 1.5 kV
Wi-Fi interface:
- Wi-Fi connection available
- WPS feature
USB interface:
- USB 2.0 interface up to 480 Mbit/s
- Quick setup thanks to plug-and-play integration
- Control: API for Windows and Linux (DELIB driver library), command-line interface
CAN interface:
- CAN interface according to ISO 11898
- Open CAN protocol (RAW CAN)
- Automatic transmit/receive mode
- Electrically isolated up to 500 V
16-bit analog inputs:
- Design: single-ended
- 16-bit resolution per channel
- Voltage ranges: 0–5 V, 0–10 V, 0–20 V, 0–40 V, ±5 V, ±10 V, ±20 V, ±40 V
- Current ranges: 0–20 mA, 4–20 mA, 0–24 mA
- Channel-to-channel isolation: max. 1 kV AC
- Electrical isolation for the power supply: max. 500 V
- A/D converter conversion time: 4 µs
Additional features:
- Configurable event control
- M2M functionality
- General
- Technical data
- ICT-Tool
- Configuration CAN
- M2M
- Event-Control
- Controlling CAN
- Connection examples
- Connectors
- Downloads & manuals
- Scope of delivery
- Accessories
Analog inputs
Analog/digital converter modules are suitable for measuring and monitoring voltages and currents. Transducers, for example, convert physical variables such as pressure, temperature, humidity etc. into corresponding currents or voltages and can therefore be recorded and digitally processed with our A/D modules.
A/D filter
Electrical or electromagnetic interference in measurement signals is smoothed and optimized by the software A/D filter by averaging the measurements.
Automatic transmit and receive mode
Use our Auto TX/RX mode and automate the workflow of your DEDITEC product by automatically processing or sending CAN packets from other participants in the network. With our free ICT-Tool, you can define how the TX and RX packets should be processed via a graphical user interface.
Plug connector
A screwless system from the manufacturer WAGO® Kontakttechnik is used as the connector. The 1-wire female connectors are 100 % protected against mismating and have an ejection and locking mechanism.
Easy installation thanks to DIN rail bus
Thanks to the practical bus connector, which is clipped into the DIN rail, individual modules of a system can be added or replaced very easily. This Plug'n Play principle makes commissioning easier for you and eliminates the need for tedious wiring.
LEDs
Each digital input and output has a separate LED that lights up when the signal status is active. The status of the operating voltage, communication with the interface, error events or the occurrence of a timeout can also be displayed.
M2M
Machine-to-machine, or M2M for short, involves direct communication between two or more modules. Analog or digital input signals from one transmitter module can be automatically transmitted to another module on a channel-by-channel basis.
M2M transmission is supported by all our products in the WEU series or by products with a CAN interface.
Event-Control
This function can be used to implement small control tasks that are saved in the module. These control tasks are configured as events and actions and then executed automatically according to the “if-then” principle.
| Power supply | +12 V ... +24 V DC |
|---|---|
| LEDs general |
|
| LEDs product-specific |
A/D-version:
D/A-version:
Thermo version:
|
| DIN rail mounting | 35 x 7,5 mm |
| Operating temperature | +10 °C ... +50 °C |
| Dimensions | 120 mm x 22.5 mm x 111 mm (H x W x D) |
Special features
| Event-Control | With our event control, you have the option of linking occurring events to a specific action. With the help of our ICT tool, the control tasks can be stored directly in the module memory thanks to an intuitive “if-then” logic. Monitor, control and regulate without an additional control PC. |
|---|
| A/D-filter | Our A/D software filter can be used to smooth and optimize electrical disturbance variables that affect the measurement signal. The filter principle is based on averaging a sum of measurements. The higher the filter level is selected, the more measurements are used to calculate the average value. |
|---|
Interfaces
CAN Interface
| CAN-Interface |
|
|---|
USB Interface
| USB-interface |
|
|---|---|
| Access speed |
|
Inputs/Outputs
Analog inputs
| Inputs |
|
|---|---|
| Conversion rates |
|
| Galvanic isolation | Galvanic isolation from the power supply: max. 500V |
| A/D-filter |
|
Connectors
| Plug connector 16-pin |
|
|---|
| Plug connector 5-pin |
|
|---|
The ICT-Tool
Integration, configuration and testing - Our all-in-one Windows tool contains all the functions you need to put our products into operation quickly, easily and efficiently. Start with the setup and configuration, install firmware updates and use the extensive test and diagnostic options. The integrated help menu provides additional support if required.
Below you will find a brief overview of the program’s basic menus.
Module selection
Here you can integrate a new product into the ICT tool by clicking on the “+” symbol and then configure it.
ICT TreeView
In the TreeView, on the left-hand side of the program window, you can see the respective control elements or functions that are supported by your selected module. The scope of the functions depends on the respective product.
Overview
All relevant module information can be accessed here at a glance.
- Module name
- Module ID
- Firmware revision
- MAC address
- LAN and WiFi Network address (module dependent)
Inputs / Outputs
This overview shows the number of I/Os supported by your module.
Module infos
Here you will find all the important feature information for your module.
General features
Here you will find all the important feature information for your module.
Digital I/O features
Here you will find information about the digital I/Os supported by the module.
Analog I/O features
Here you will find information about the type of analog I/Os supported by your module.
Special I/O features
Here you will find information about the type of special I/Os supported by your module.
In den folgenden Kapitel, würden wir Ihnen unsere neue All-In-One-Software gerne genauer vorstellen.
Info
All relevant module information can be called up here at a glance.
- Module name
- Module ID
- Firmware revision
- Interface type
- Current DIP switch setting (only for Ethernet modules)
Identification
If several DEDITEC Ethernet modules are active in the network, a signal LED on the selected module can be activated via an identification function. This facilitates visual assignment.
Restart
You can restart your module here. The module status shows whether the restart was successful.
USB configuration
If you want to use several USB modules from the same product series on one PC, each of these modules must first be assigned its own module number.
LAN info
On this information page, you will find the current LAN network information and all the settings for your module at a glance.
LAN configuration
Integrate the product into your network or control it directly via a 1-to-1 connection.
The following parameters can be changed.
- Board name
- DHCP on/off
- IP address
- Subnet mask
- Default gateway
- TCP Port
WiFi info
All important WiFi settings are displayed on this page
WiFi configuration
Here you can change the network settings of the selected WiFi product.
The following settings can be made:
- Board name
- WLAN on/off
- Router name
- Router password
WPS
With the WPS function, your module can be connected to the router quickly and easily, automatically (WPS on the router is required)
CAN configuration
With our CAN products in the BS, NET and UC series, settings for the interface and the TX/RX packets can be made using the ICT tool.
More information can be found here:
Serial configuration
For our serial products in the BS, NET, UC and RO series, changes to the interface can be made using the
ICT tool.
More information can be found here:
Modbus TCP
Here you can set the Modbus TCP configuration of the module.
The following configurations can be made.
- Enable/disable access via Modbus TCP
- TCP port
TCP encryption
Here you can make settings for the encryption of your module.
The following configurations can be made.
- Allow unencrypted protocol
- Allow “User” encryption mode
- User password
- Allow “Admin” encryption mode
- Admin password
NTP configuration
You can make changes to the NTP service here.
The following configurations can be made.
- NTP service on/off
- server
- Port
- Timezone
WEB-Login
Here you can change the login settings of the web interface.
The following configurations can be made.
- Session duration
- Login name
- Login password
- Allow I/O access via web interface
D/A Default Values
Here you can set the D/A values and modes with which the module should be started.
The value and mode can be set individually for each channel.
Watchdog configuration
Here you can make and save settings on your watchdog stick.
Save or Load config
Using the “Save or Load config” function, you can save your entire module configuration in an external XML file.
This means you can always load your module in the desired original state.
The following configurations can be saved depending on the module type.
- USB configuration
- LAN configuration
- WiFi configuration
- TCP encryption
- NTP configuration
- Serial configuration
- CAN configuration
Status
This gives you an overview of the activity of the transmitter and receiver module
The following information from the transmitter module is displayed:
- Status of the activity: If the check mark is set, this action is currently being performed.
- Total number of actions performed. Is reset to 0 after a restart of the module.
- Number of actions per second.
- Number of DELIB errors that occur when executing commands from the DEDITEC driver library.
The following information from the receiver module is displayed:
- Connected: If the check mark is set, the transmitter and receiver modules are connected.
- IP address of the receiver module.
- Number of connection attempts.
Receiver modules
You can set the network settings of the receiver module here.
The following settings can be made
- Name for the receiver module
- Network settings of the receiver module
- Timeout
- Encryption type/ password
Action
With an action, you define which input signal is to be sent from the transmitter module to which output of a receiver module.
The following settings can be made:
- Type of task (digital, analog)
- Which receiver module should be used
- The interval at which the operations are to be carried out
- Start channel of the transmitter module
- Number of channels to be transmitted
- Start channel of the receive module
In the image on the right, DI data is sent every 100ms from channel 3(CH Start) to channel 8 ((CH Start) + (CH Count)) to channels 0-5 of the target module.
In den folgenden Kapitel, würden wir Ihnen unsere neue All-In-One-Software gerne genauer vorstellen.
Status
The Status area provides an overview of all active events and executed actions.
The following information is listed:
- Event number
- Event type
- Time interval of the event
- Number of events that have occurred
- Action number
- Number of triggered actions
- Number of other actions
Events configuration
Up to 16 different events can be created in the configuration menu. An event can be used, for example, to define switching thresholds at the analog inputs or logical states at the digital inputs of the module and link them to an executable action. The configuration itself is saved permanently in the module configuration memory of the module.
The following event modes are available, depending on the module type:
- DI: High-Low state of a digital input.
- DI flip-flop: Status change of a digital input (is stored in the module with the so-called flip-flop flag and deleted again after readout).
- DO readback: ON-OFF status of a digital output (is read out using a DO readback command).
- A/D: Current or voltage level at the analog inputs
Configuration actions
Up to 16 different actions can be created in the configuration menu. An action defines what should happen within an event after a condition is met.
The following action modes are available, depending on the module type:
- Set DO output: Switches a digital output on or off
- Set D/A output: Outputs a current or voltage value at an analog output
- Send CAN packet: A special CAN TX event is triggered (up to eight CAN TX events can be configured separately).
Digital Out
Hier können Sie die digitalen Ausgänge Ihres Modules ein- und ausschalten.
Folgende Funktionen können in dieser Form getestet werden.
- Kanalweise Ein- und Ausschalten der digitalen Ausgänge
- Readback der Kanäle
- Setzen eines Digitalausgangs für eine bestimmte Zeit (Modulabhängig)
- Gibt an welchen Status die Kanäle nach Ablauf der Zeit einnehmen sollen (Modulabhängig)
- Testen der Ausgänge
Digital Out
All digital outputs of your product can be checked by clicking on the buttons.
The following switching options are possible:
- Switching on and off channel by channel
- Channel-by-channel switching on or off for a specific time (product-dependent)
- Reading back the switching status (readback)
Digital In
In this view, the logical states of all optocoupler inputs can be read out.
The following information is displayed:
- Logical status of the inputs (ON/OFF)
- Number of detected pulses (counter function)
- Change of state detected (flip-flop)
TTL I/O
In this menu, the TTL channels of the module can be configured as inputs or outputs. The individual TTL outputs can be switched on or off by pressing the buttons. In addition, the status of all TTL inputs can be read out.
The tool offers the following functions:
- Configuration of the channels as input or output (in blocks of 8)
- Switching on and off channel by channel
- Reading back the switching status (output readback)
- Displaying the logical status of the inputs (input readback)
Analog Out
Here you can test the analog outputs of the module and manually enter any voltage or current value.
Analog In
In this menu, voltage or current values of all A/D channels can be displayed.
It is also possible to activate our A/D software filter with different filter levels.
CAN Runtime Parameter
Here you can change the CAN settings of the interface, the RX and TX packets in runtime.
The following settings can be made:
- Baud rate
- Extended ID
- Active on/off
- CAN ID
- Mode
CNT48
Here you can read out the counter readings of a counter module, select filter options and set various counting modes.
The following counting modes are supported:
- Read on rising edge
- Read on rising edge x2
- Read on rising edge x4
- Period duration
- Frequency measurement
- PWM measurement
Pulse generator
The pulse generator can be used to generate square-wave signals. High and low time as well as the number of pulses can be set here.
PWM Out
In this menu you have the option of testing various PWM frequencies. In addition, the duty cycle can be entered manually for each individual channel.
Temp
The temperature of all connected temperature sensors is displayed here directly in °C.
Graphical display
This menu allows a graphical representation of all analog input signals, such as A/D, temperature or FIFO-IN.
Watchdog
This tool can be used to check the configured watchdog parameters for correct function.
I/O – Timeout
You can use the timeout function in the I/O area to simulate a timeout case for your module.
The following is a description of the timeout window
- Read / Write symbol: Flashes to indicate an active connection to the module
- Automatic access: Removing the tick triggers a timeout after the timeout time has expired
- Manual access: Manual retrieval of data from the module
- Timeout status: Shows whether the timeout is active and whether a timeout event has occurred
- Timeout mode: Selection between 3 timeout modes, Normal, Reactivate and Secure
- Timeout duration: The time after which the timeout should be triggered is set here
- Activate / deactivate: Activates or deactivates the timeout function
Access times tests
You can test the access times for the module here. The following access time tests can be performed:
- Register – Read/Write/Write + Readback
- Digital I/O – Read/Write/Write + Readback
- Analog I/O – Read/Write/Write + Readback
Access times tests
This test can be used to determine the access times to the module. The test values are read and written in 8, 16, 32, or 64-bit commands.
Access times Register
The following example checks the register accesses to an Ethernet module. The average access time here is 0.5 ms.
Access times Analog I/O
In the following example, the access times to an Ethernet module with analog I/Os are checked. The average access time here is 0.6 ms.
Access times Digital I/O
In the following example, the access times to an Ethernet module with digital I/Os are checked. The average access time here is 0.6 ms.
Cable feedback tests
For this test, the digital or analog outputs of the module are connected to the corresponding digital or analog inputs of the module via cable. The feedback test now checks whether the output and input values match.
Cable return test
The cable return test can be used to check the function of all digital and analog inputs and outputs (I/Os) of a module. To do this, inputs and outputs are wired together externally on a 1:1 basis. The test software analyzes whether the output signals arrive correctly at the inputs, thereby identifying wiring errors or hardware defects.
Analog test
In analog test mode, the D/A converter outputs defined test voltages, which are then read in by the A/D converter and compared with the target values. The software counts the number of test runs and automatically documents any deviations.
Digital test
In the digital test, the switching states of the relay or MOSFET outputs are fed back externally to the optocoupler inputs. Here, too, the software counts and compares the number of cycles and automatically detects transmission errors or deviations.
Cable return test
The cable return test can be used to check the function of all digital and analog inputs and outputs (I/Os) of a module. To do this, inputs and outputs are wired together externally on a 1:1 basis. The test software analyzes whether the output signals arrive correctly at the inputs, thereby identifying wiring errors or hardware defects.
Analog test
In analog test mode, the D/A converter outputs defined test voltages, which are then read in by the A/D converter and compared with the target values. The software counts the number of test runs and automatically documents any deviations.
Digital test
In the digital test, the switching states of the relay or MOSFET outputs are fed back externally to the optocoupler inputs. Here, too, the software counts and compares the number of cycles and automatically detects transmission errors or deviations.
A/D ripple
The ripple test displays the residual ripple of the individual A/D inputs.
A/D quality measurements
The quality of an A/D measurement is influenced by various factors and can be affected by external interference. A reliable method for checking measurement quality is to measure a stable battery voltage. Our diagnostic tools can be used to determine the residual ripple and noise behavior.
A/D ripple
The A/D ripple test can be used to measure the residual ripple of the individual A/D inputs and check for interference signals such as mains hum or voltage instabilities.
A/D noise
The noise behavior of each A/D channel can be displayed graphically using A/D noise measurement. Additional filter stages with averaging can be used to smooth and improve the measurement signal.
FIFO In/Out
The software FIFO test can be used to specifically test the integrated FIFO buffering of our digital and analog NET I/O modules. Depending on whether it is an input or output module, data is read from the submodule FIFO or written to the submodule FIFO.
FIFO settings
The submodule number can be used to specify which module is to be tested. The start and end channels can also be used to transmit several channels simultaneously. In addition, the transmission frequency can be set and the desired FIFO mode selected – for example, for the use of test values or the actual measured values of the module.
All important information at a glance
During program execution, key information such as the size of the data packets, free and occupied bytes in the FIFO buffer, the number of data packets sent or received, and the current FIFO status are clearly displayed.
D/A output test
The D/A output test enables targeted testing of each individual D/A channel of a module. A freely selectable test voltage can be output directly. Currently, simple square wave signals with configurable high and low times are available. The signals can be monitored simultaneously with an oscilloscope. This function is also ideal for long-term tests. The test software detects DELIB errors and logs them automatically.
Mustertext
Mustertext
DO 4* value + wait
In this test, adjustable 16-bit values are written to the digital outputs of the module.
The values are sent to the module using the DapiDOSet16 command. The start channel is always channel 0.
You can set different wait times between the individual calls.
The test is intended for testing the functionality of the module.
Mustertext
Mustertext
Modbus I/O test
In the diagnostics section of the ICT-Tool, you can test the module’s digital and analog inputs and outputs directly via Modbus TCP. Register addresses as well as transfer and return values are displayed in a debug panel, allowing you to quickly diagnose problems with the D/A converter, for example. A complete overview of all register addresses and examples can be found in the Modbus manual at the following link:
To benefit from the latest functions and prevent errors, we recommend that you always keep your DEDITEC product up to date.
Flash Files
Downloading the firmware flash file package via the ICT tool
- Go to Flash Files in the “Firmware update” menu
- Click on the download button to start the download.
- Administration rights are required for the automatic unpacking of the flash files. If these rights are not available, the files are downloaded to the download area of your PC and must be extracted manually to the installation directory.
\DEDITEC\DELIB\programs\flash_files
Downloading the firmware flash file package via the DEDITEC homepage
- Download the required firmware flash file package from our homepage: Downloads -> Software -> Firmware
- Extract the files to the following installation path: ..\DEDITEC\DELIB\programs\flash_files
Flash modules
In the “Firmware update” menu, select the module you want to update and then click on the “Flash modules” or “Flash submodules” button.
The firmware is now updated and the module is then restarted automatically.
Information on the firmware flasher
The following information is displayed in the firmware flasher:
- Last FW: Displays the last firmware version
- Current FW: Displays the currently installed firmware version
- Newest FW: Displays the latest firmware version
- Log: Displays status or error messages during the flash process
In den folgenden Kapitel, würden wir Ihnen unsere neue All-In-One-Software gerne genauer vorstellen.
General
Here you can make general configurations to the ICT tool.
The following changes can be made:
- Language – setting between German and English possible
Updates
Here you can search for available DELIB or firmware updates.
- Automatic update search at program start
- Search for DELIB updates
- Search for firmware updates
Error log
Here you can make settings for the deditec_debug.log. This is saved under the path C:\Users\?USER?\AppData\Local\DEDITEC.
The following settings can be made:
- Enable writing to the debug.log
- Activate log notifications
- Activate automatic deletion of the debug.log
- Setting after how many days the debug.log should be deleted
- Set the maximum size of the debug.log
DELIB – DebugView – Global
Settings can be made here for the information that is to be displayed with the DebugView.
- Activate debug output
- Activate display of errors
DELIB – DebugView – Details
More detailed settings can be made here for the information to be displayed with the DebugView.
Configuration of CAN modules
The parameters of the CAN interface can be fully configured via the ICT-Tool. In addition to the baud rate, CAN address and other settings, automatic send and receive packets can also be set up.
Automatic transmission (TX mode)
The Auto-TX mode allows cyclical transmission of data packets, optionally with analog or digital input states to other CAN addresses. Alternatively, a trigger event can also be defined. In this case, a data packet is only sent once a data packet has been received on a certain CAN ID (e.g. CAN sync on ID 0x80).
Automatic receiving (RX mode)
With Auto-RX mode, on the other hand, received data packets are forwarded directly to analog or digital outputs. For example, relay outputs can be set via another CAN bus subscriber.
ICT-Tool
The ICT-Tool can be used to quickly and easily read out or change CAN interface settings.
Status interface
Here you can find information about the status of the CAN interface
- Baud rate
- Module address
- Receiving address
- CAN status
- Extended ID
- CAN modus
Hier finden Sie Informationen über die TX / RX -Pakete
- Anzahl gesendeter / empfangener Pakete
- TX / RX – Pakete pro Sekunde
- Durchschnitt gesendeter / empfangener Pakete
Settings can be made on the CAN interface here.
- Baud rate
- Adress Bit-mode
- Module address
- Receiver address
Here you can configure the CAN settings of the connected submodules.
- A/D mode
- A/D filter
- D/A mode
- Counter mode
- Timeout
- CNT48 mode
- CNT48 submode
- CNT48 filter
Here you can make settings to the TX package configuration.
- activate / deactivate
- Trigger mode
- Interval
- Use extended ID
- Send to CAN-ID
- TX mode
You can make settings to the RX package configuration here.
- activate / deactivate
- Use extended ID
- Receive from CAN-ID
- RX mode
You can find more details on control and some programming examples in the programming section.
M2M
Machine to Machine
M2M is the abbreviation for “machine-to-machine” and enables automatic data transmission between two or more devices. This means that analog or digital input signals from a transmitter module can be automatically transmitted to a receiver module, where they are immediately output again.
Data exchange without a control PC
The modules communicate directly at device level and therefore do not require any additional user software. The one-off configuration of the transmitter module can be carried out very easily using our ICT-Tool. All settings remain permanently stored in the module memory, even in the event of a power failure. After a restart, the module automatically switches back to M2M operation.
M2M Ethernet or M2M CAN
With our DEDITEC products, we differentiate between M2M Ethernet and M2M CAN. We also refer to the latter as CAN-TX/RX mode. Both M2M methods are supported by most of our modules with Ethernet or CAN interface.
M2M-CAN
All DEDITEC products with a CAN interface are equipped with the M2M-CAN feature. The “Auto TX/RX mode” can be set in the ICT-Tool via the configuration menu. Depending on the product type, 8(4) TX and 8(4) RX modes can be defined.
"TX modes" submenu
The pictures on the right show an example configuration for a transmitter module (TX mode) and a corresponding receiver module (RX mode).
The TX mode on the transmitter module sends the logical states of inputs 1-64 to CAN ID 0x700 every 500ms.
The RX mode on the receiver module receives data packets on CAN ID 0x700 and outputs these values to outputs 1-64.
General information on Event-Control
In den folgenden Kapitel, würden wir Ihnen unsere neue All-In-One-Software gerne genauer vorstellen.
To make our modules even more customer-friendly and flexible and to make it easier for you to enter the world of automated control technology, we have implemented Event-Control as a new feature in our products. This function can be used to implement small control tasks that are stored in the module. These control tasks are configured as events and actions and then executed automatically according to the “if-then” principle.
Configuration in the ICT-Tool
The ICT-Tool can be used to configure and monitor 16 events and 16 actions.
Processing in the module
The events stored in the module are automatically monitored and processed by the CPU in the module after the module is started. As soon as the set condition (“event”) is fulfilled, the corresponding action is executed. This automatism in the module makes an additional control PC with associated user software superfluous.
Functions
The following actions, among others, can be combined with the Event-Control:
- Monitoring the analog and digital inputs (A/D, DI)
- Setting switching thresholds for analog inputs
- Switching the module outputs (relay, MOSFET, D/A)
- Sending CAN packages
We are constantly expanding the range of promotional options. We are also happy to implement your special customer requirements on request.
Modulauswahl
Hier können Sie Ihre Module mit einem Klick auf das „+“ Symbol ins ICT-Tool einbinden, um diese anschließend konfigurieren oder testen zu können.
Module series that support this function:
- BS-USB2 series
- BS-WEU series
- NET series
- UC series
- CAN-Box series
Module series that do not support this function:
- Starter series
- RO series
- COS series
ICT Treeview
Im Treeview auf der linken Seite des Programmfensters, sehen Sie die jeweiligen Formen, die von Ihrem Modul unterstützt werden.
Mit einem Klick können Sie sich diese Form dann im rechten Teil des Programmes anzeigen lassen und mögliche Konfigurationen oder Tests durchführen.
In den folgenden Kapitel, würden wir Ihnen unsere neue All-In-One-Software gerne genauer vorstellen.
With the Event-Control module, you can react flexibly and automatically to external signals – directly on the I/O module, without a PC or additional controller.
How does it work?
The system registers external events, such as the switching of an input or the triggering of a sensor, and then executes predefined actions. These actions can be simple tasks such as switching on a relay or sending a CAN message.
The advantages:
-
Independent processing – Control takes place directly on the module, independently of the host system.
-
Flexibly customizable – you can link any inputs and outputs together.
-
Complex logic possible – Thanks to logical operators such as AND, OR or NOT, even more sophisticated controls can be implemented.
-
Simple configuration – events and actions are conveniently defined via our ICT-Tool and transferred to the module without any programming knowledge.
Example:
A digital input detects the opening of a door. The system then automatically switches on a light without a PC being involved.
Modulauswahl
Hier können Sie Ihre Module mit einem Klick auf das „+“ Symbol ins ICT-Tool einbinden, um diese anschließend konfigurieren oder testen zu können.
Modulserien, die von dieser Funktion unterstützt werden:
- BS-USB2-Serie
- BS-WEU-Serie
- NET-Serie
- UC-Serie
- CAN-Box
Modulserien, die von dieser Funktion nicht unterstützt werden:
- Starter-Serie
- RO-Serie
- COS-Serie
ICT Treeview
Im Treeview auf der linken Seite des Programmfensters, sehen Sie die jeweiligen Formen, die von Ihrem Modul unterstützt werden.
Mit einem Klick können Sie sich diese Form dann im rechten Teil des Programmes anzeigen lassen und mögliche Konfigurationen oder Tests durchführen.
Our ICT-Tool in the “Statistics” section provides a quick overview of all current campaigns and events.
Eine mini SPS
Um unsere Module noch kundenfreundlicher und flexibler zu gestalten und Ihnen den Einstieg in die Welt der automatisierten Steuer- und Regelungstechnik zu erleichtern, haben wir als neues Feature das sog. Event-Control in unsere Produkte implementiert. Mit dieser Funktion lassen sich kleine Steueraufgaben in das Modul speichern, die anschließend nach dem „Wenn-Dann“ Prinzip automatisch Aktionen ausführen.
The following information can be taken from the statistics:
- Executed event no.
- Event mode
- Interval
- Number of events executed
- Number of the executed action
- Number of actions performed
Modulserien, die von dieser Funktion unterstützt werden:
- BS-USB2-Serie
- BS-WEU-Serie
- NET-Serie
- UC-Serie
- CAN-Box
Modulserien, die von dieser Funktion nicht unterstützt werden:
- Starter-Serie
- RO-Serie
- COS-Serie
ICT Treeview
Im Treeview auf der linken Seite des Programmfensters, sehen Sie die jeweiligen Formen, die von Ihrem Modul unterstützt werden.
Mit einem Klick können Sie sich diese Form dann im rechten Teil des Programmes anzeigen lassen und mögliche Konfigurationen oder Tests durchführen.
An event is used to execute a specific action as soon as a condition is met.
A time period can also be specified for how long the condition must be fulfilled in order to execute an action.
These settings are saved directly in the Module-Configuration-Memory of the module.
Example: Voltages can be automatically output via the D/A converter or relays can be switched when a previously defined switching threshold is reached at the A/D inputs or a signal is detected at a digital input.
Depending on the features of your product, you can choose from different modes:
“DI” / “DI flip-flop” / “DO readback”
DI: High or low signal of a digital input.
Flip-Flop: If the status of the digital input changes, the flip-flop of the channel is set and then reset again.
DO-Readback: The status of the output channel is read out.
The following settings can be made:
- Number of the channel to be monitored
- Condition of the channel status (on = 1 / off = 0)
- Minimum time to wait until the action is triggered
- Number of the action to be executed (this is configured in the Action area)
“A/D”
The voltage currently present at the analog input is read out.
The following settings can be made:
- Number of the channel to be monitored
- A/D mode (selection depends on module)
- Condition that must be fulfilled (value greater than … , value less than … , value in a range)
- Values that must be achieved for the condition
- Minimum time to wait until the action is triggered
- Number of the action to be executed (this is configured in the Action area)
In the “Actions” section of our ICT-Tool, you define which tasks are to be performed automatically as soon as a condition (“event”) is fulfilled.
For example, you can specify that a certain CAN packet should be sent when a certain voltage is measured on an A/D channel or a signal is detected at a digital input.
Depending on the features of your product, you can choose from different modes:
Folgende Informationen können der Statistik entnommen werden:
- Ausgeführte Event-Nr.
- Event-Modus
- Intervall
- Anzahl ausgeführter Events
- Nummer der ausgeführten Aktion
- Anzahl ausgeführter Aktionen
“Set D/A output”
Outputs a voltage or a current at an analog output.
The following settings can be made:
- Number of the channel on which the action is to be executed
- D/A mode (selection depends on module)
- Voltage or current to be output
- Time to wait before executing the action again
“Set DO output”
Switches a digital output on or off.
The following settings can be made:
- Number of the channel to be controlled
- State (0 = off / 1 = on) that is to be set
- Time to wait before executing the action again
“Send CAN package”
The set CAN TX event is triggered. For this function, the trigger mode in the CAN TX package must be set to “TX-EVENT” (see configuration).
The following settings can be made:
- Number of the CAN TX event to be triggered
- Time to wait before executing the action again (prevents a CAN packet from being sent too frequently)
You can find more information on configuring TX mode here:
Control of our CAN modules
Our RAW CAN modules can be controlled in two ways:
1. Auto TX/RX mode
2. DELIB command mode
1. Auto TX / RX mode
This operating mode allows the module to process CAN packets automatically without the need for an additional control PC. Configuration is very simple using the ICT tool and requires no programming knowledge.
Automatic transmission (TX mode)
Auto-TX mode allows automatic, cyclical transmission of CAN packets to other bus participants. The module's digital and analog input signals can thus be forwarded directly to other devices.
As an alternative to cyclic transmission, trigger events can also be defined. This means that a CAN packet is only sent, for example, when a CAN message has been received on a specific CAN ID.
TX mode configuration
The following settings can be configured:
- Enable/disable TX mode
- Trigger mode
- Interval
- Use extended ID
- Send to CAN ID
- TX mode
Automatic receive (RX mode)
In Auto-RX mode, received data packets are forwarded directly to the analog or digital outputs of the module. For example, relay outputs can be set on the module via another CAN bus participant.
RX mode configuration
The following settings can be configured:
- Enable/disable RX mode
- Use extended ID
- Receive from CAN ID
- RX mode
2. DELIB command mode
In DELIB command mode, the module's registers are accessed via a CAN protocol developed by DEDITEC. The module expects the CAN messages on a CAN address specified in command mode. Read and write accesses with different data lengths (BYTE, WORD, LONG) are possible. Details on the protocol structure and register assignment can be found in the “Protocols & Register Assignment” manual in the download area.
Connection example AD2-ISO I-Mode:
Connection example AD2-ISO U-Mode:
Connection example AD2-ISO with extended U-Mode:
Screwless connector system
The customer-side connection wiring of the inputs and outputs is carried out using screwless, pluggable terminal strips. The conductor connection is made using a so-called actuating tool.
A locking and ejecting mechanism facilitates the insertion and removal of the complete terminal strip.
Handling:
Steps 1-5
Step 1
See the scope of delivery for the operating tool.
Step 2
Insert the operating tool firmly into the side opening in the direction of the conductor connection.
Step 3
Now insert the stripped conductor into the open clamp contact.
Step 4
Pull out the operating tool again.
Step 5
Check that the conductor is properly connected. It should now no longer be possible to pull it out easily.
Manual
Manual UC series
Quickstart - Hardware description - Software description - ICT-Tool
- Safety instructions
- Installing the drivers
- Connecting the power supply
- Connecting to the PC or network
- Connecting the I/O connectors
- Function test
Hardware description
- List of technical data
- Definition of the LEDs
- Functions of switches and buttons
- Pin assignment of the connectors
- Connection examples
Software description
- Control options via the DELIB, protocol level, DELIB CLI, graphical applications
- DELIB Driver Library, DELIB Sample Sources, DELIB for Linux
- Web interface (only for Ethernet modules)
- DELIB API and its functions
ICT-Tool
- Add module on the PC
- Configure module/interface (Ethernet, USB, CAN, serial)
- Setting options for M2M and event control (only for supported modules)
- Test and diagnose module
- Install firmware updates
- Save/load module configurations using a separate file
Software packages ICT-Tool / DELIB driver library
ICT-Tool + DELIB for Windows (64-bit)
For Windows 11/10, Windows 7, Windows 8, Vista, XP and 2000
Software package for the 64-bit version of the ICT-Tool and the DELIB driver library.
The following operating systems are compatible:
64-bit:
- Windows 10/11 x64
- Windows 8 x64
- Windows 7 x64
- Windows Server 2012 x64
- Windows Server 2008 x64
- Windows Vista x64
- Windows XP x64
- Windows Server 2003 x64
- Windows 2000 x64
Supplied software
ICT-Tool x64
- Updating the DEDITEC module-firmware
- Assigning module addresses
- Module-specific settings
- Configuration of CAN modules
- Test and diagnosis of module functions
- Configuration of the watchdog stick
Replaces the following software
- DT-Flasher x64
- DELIB Module Demo x64
- CAN Configuration Utility x64
- DELIB Module Config x64
- DELIB Configuration Utility x64
- Watchdog Configuration Utility x64
DELIB Command Line Interface x64
Enables the execution of DELIB commands in the command line.
ICT-Tool + DELIB for Windows (32-bit)
For Windows 11/10, Windows 7, Windows 8, Vista, XP and 2000
Software package for the 32-bit version of the ICT-Tool and the DELIB driver library.
The following operating systems are compatible:
32-bit:
-
-
- Windows 10/11
- Windows 8
- Windows 7
- Windows Server 2012
- Windows Server 2008
- Windows Vista
- Windows XP
- Windows Server 2003
- Windows 2000
-
Supplied software
ICT-Tool x32
-
-
- Updating the DEDITEC module-firmware
- Assigning module addresses
- Module-specific settings
- Configuration of CAN modules
- Test and diagnosis of module functions
- Configuration of the watchdog stick
-
Replaces the following software
-
-
- DT-Flasher
- DELIB Module Demo
- CAN Configuration Utility
- DELIB Module Config
- DELIB Configuration Utility
- Watchdog Configuration Utility
-
Attention:
With this version of the driver library, only 32-bit applications can be created, which can then be executed on 32- and 64-bit systems.
DELIB driver library for Linux (32/64-bit)
For 32/64-bit Linux distributions from kernel 2.6.x. Version 2.73 from 28.10.2024
DELIB driver library for Linux distributions (32/64-bit) from kernel 2.6.x
This driver package contains the following components
- DELIB USB driver
- DELIB Ethernet driver
- DELIB CLI
DELIB USB driver
Support for the following products:
- NET series (via USB interface)
- RO-USB series
- BS-USB series
- USB mini-sticks
- USB watchdog
- USB-OPTION-8 / USB-RELAY-8
- USB-TTL-32 / USB-TTL-64
Note:
With the standard version of the USB driver, several USB products with different module IDs (e.g. one RO-USB and one USB-OPTOIN-8) can be addressed. No further driver installation is required.
If several USB products with the same module ID (e.g. a USB-OPTOIN-8 and a USB-RELAIS-8) are to be addressed, the Linux FTDI driver must also be installed. You can find the FTDI driver at http://www.ftdichip.com.
DELIB Ethernet driver
Support for the following products:
- NET series (via Ethernet interface)
- RO-ETH series
- RO-ETH/LC series
- BS-ETH series
- ETH-OPTION-8 / ETH-RELAY-8
- ETH-TTL-64
DELIB CLI
With the DELIB CLI (Command Line Interface) for Linux, all commands for digital and analog I/Os can be set directly via the command line
Manual
Manual for ICT-Tool and DELIB
Software Description - ICT-Tool - DELIB API Reference
Software Description
- Control options via DELIB, protocol level, DELIB CLI, graphical applications
- DELIB driver library, DELIB sample sources, DELIB for Linux
- Web interface (only for Ethernet modules)
- DELIB API and its functions
ICT-Tool
- Add module to PC
- Configure module/interface (Ethernet, USB, CAN, Serial)
- Settings for M2M and Event Control (only for supported modules)
- Test and diagnose module
- Install firmware updates
- Save/load module configurations using a separate file
DELIB API Reference
- Directory structure of DELIB
- Management functions
- Error handling
- Manage digital inputs and outputs
- Manage analog inputs and outputs
- Manage software FIFO
- Manage output timeout
- Register read and write commands
Download
Hardware updates (firmware flash file package)
Firmware flash file package for the ICT tool
This package contains the latest firmware files for the following product series:
- STARTER series
- BS series
- RO series
- NET series
- UC series
- CAN-IO-Box
- Development accessories
The firmware flash file package can alternatively be downloaded via the ICT tool.
USB cable A plug to C plug
USB cable for connecting our modules to the control PC.
- Type: USB 2.0, A plug to C plug
- Length: 1 m
5-pin plug connector
Enables the power supply to be connected to the DEDITEC module.
- Type: Phoenix Contact® - 1876343
- 100 % mismatch protected
- For all conductor types from 0.2 mm² to 2.5 mm²
16-pin plug connector
Required for connecting inputs and outputs of the DEDITEC module.
- Type: WAGO® 713-1108/037-000
- Plug-in female multipoint connector with locking mechanism
- 100 % mismatch protected
- 1-wire connection for all conductor types up to 1.5 mm²
Actuating tool for Wago connectors
Used to open and close the terminal contacts on the WAGO® connectors.
- Type: WAGO® - 734-231
DIN-Rail connector
The DIN rail connector is a single BUS segment that enables connection to other modules. It is clipped into the top-hat rail and plugged onto the side of an existing DIN rail connector.
- Type: Phoenix Contact® - 2203852
- Connection of a NET or UC module
- For expanding the NET or UC bus system
- 1 Piece
USB cable A plug to C plug
USB cable for connecting our modules to the control PC.
- Type: USB 2.0, A plug to C plug
- Length: 1 m
5-pin plug connector
Enables the power supply to be connected to the DEDITEC module.
- Type: Phoenix Contact® - 1876343
- 100 % mismatch protected
- For all conductor types from 0.2 mm² to 2.5 mm²
16-pin plug connector
Required for connecting inputs and outputs of the DEDITEC module.
- Type: WAGO® 713-1108/037-000
- Plug-in female multipoint connector with locking mechanism
- 100 % mismatch protected
- 1-wire connection for all conductor types up to 1.5 mm²
Actuating tool for Wago connectors
Used to open and close the terminal contacts on the WAGO® connectors.
- Type: WAGO® - 734-231
DIN-Rail connector
The DIN rail connector is a single BUS segment that enables connection to other modules. It is clipped into the top-hat rail and plugged onto the side of an existing DIN rail connector.
- Type: Phoenix Contact® - 2203852
- Connection of a NET or UC module
- For expanding the NET or UC bus system
- 1 Piece
Strain relief plate for 16 or 18-pin Wago connectors
The strain relief plate is pushed onto the center of the female connector and enables the connected cables or strands to be fixed in place.
- Type: WAGO® - 713-127
- Strain relief for the connection wiring
- Suitable for 16 or 18-pole female connectors
- Slide onto the female connector from the side
Top hat rail
Top-hat rail for mounting our control technology modules.
- DIN rail according to DIN EN 50022
- Type: Phoenix Contact® - 1208131
- Dimensions in mm: 450 x 35 x 7.5 (L x W x H)
24V/2A power supply unit for top-hat rail mounting
The DR-4524 from Mean Well is a 48W power supply unit for DIN rail mounting for industrial applications. It offers protection against short circuit, overload, overvoltage and overheating.
- Input voltage range: 85 V.. 264 V AC / 120 V DC ... 370 V DC
- Output voltage: 24 V DC
- Output current: 2 A
- Rated power: 48 W
Typical Application Areas:
- Process optimization through automation:
Thanks to the integrated auto TX/RX mode, modules can communicate directly with each other and exchange signals—without the need for an additional control PC. - Decentralized CAN network nodes:
The industry test bench module with CAN and galvanic isolation is suitable as a decentralized CAN I/O unit within industrial control architectures. Via the CAN bus, states and data are reliably transmitted and distributed to other system participants, enabling the integration of remote system areas into a centralized structure. - Industrial sensor data acquisition:
The analog inputs are suitable for precise acquisition of physical measurement variables such as pressure, temperature, or fill levels in industrial processes. - Laboratory and testing technology:
The industry test bench module with CAN and galvanic isolation is ideally suited for experimental setups, data acquisition, and calibrations where high accuracy and reliability are essential. - Process data acquisition in production:
Ideal for capturing continuous process values in manufacturing plants in order to make production workflows transparent and analyzable.
Comparison of UC-CAN-AD2-16ISO with common market products
Interfaces & Communication |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
|---|---|---|---|
| Protocol transparency | For many standard modules, the telegram structure or integration is manufacturer-specific. | Open CAN protocol for seamless integration into existing CAN architectures. | Facilitates integration into existing controllers, gateways, and CAN networks. |
| Automatic telegram processing | Recurring CAN telegrams often have to be processed using external control logic. | Auto TX/RX mode for automatic processing of CAN packets. | Reduces the implementation effort in the controller and simplifies recurring communication tasks. |
| CAN standards and bit rates | Supported CAN parameters are often limited or less clearly specified. | Supports CAN 2.0A / 2.0B and bit rates from 10 kbit/s to 1 Mbit/s. | Offers greater flexibility when integrating into different CAN systems and existing installations. |
| Industrial use | Often used for simple control tasks | Designed for industrial automation and CAN networks | Suitable for demanding applications with high requirements for stability and continuous operation. |
| USB Standard | usually only USB-A / B | Thanks to USB-C, it is significantly more modern and faster than typical USB I/O boards | Improves compatibility with current devices and simplifies integration. |
| Number of USB modules that can be used simultaneously | 1–4 modules, often without proper management | Up to 16 modules per system | Enables larger system configurations without additional distributors or expansion devices. |
| Galvanic isolation of the CAN interface | A galvanically isolated CAN interface is not standard on all devices. | Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments. | Improves interference immunity and protects communication in harsh industrial environments. |
Analog inputs |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
| Current and voltage measurement | Some providers offer only voltage or only current | Both signal types supported | Enables the use of different sensor types without additional signal converters, thereby reducing hardware and wiring costs. |
| Resolution and accuracy | Typically 8–12 bit | High‑resolution 16‑bit for precise signal control | Improves measurement accuracy and enables reliable evaluation of even small signal changes. |
| Firmware filtering | External filtering required | Smoothing and averaging directly in the module; filters adjustable | Reduces measurement noise and ensures more stable input values without external filter hardware. |
| Galvanic isolation | Often, there is no isolation from the power supply | Electrical isolation for the module’s power supply | Protects connected systems from interference voltages and prevents interactions between measurement circuits and the power supply. |
| Galvanic isolation between all channels | Often a common reference potential for all channels | Galvanic isolation up to 500 V between all channels | Enables measurements in environments with different reference potentials and prevents compensation currents between channels. |
Automation & Diagnostics |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
| Diagnostic tools | Mostly not available | Extensive diagnostic capabilities integrated in the ICT tool | Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions. |
| Automated control and monitoring | Additional control PC required | Configurable event control enables automated process monitoring without a control PC | Reduces the need for external control logic and enables automated processes directly within the module. |
Hardware flexibility |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
| Supply voltage | Usually fixed (e.g., +24 V) | Flexible +12 V DC … +28 V DC | Facilitates use in various power supply configurations and reduces the need for additional power supplies. |
| EMC stability | Low-cost OEM modules often susceptible to interference | Industrial‑grade EMC design | Ensures low-interference operation in industrial environments with high electromagnetic interference. |
Software & Integration |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
| Software integration | Limited drivers | DELIB library for C, C++, C#, Java, VB | Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations. |
| Example programs | Barely available or only upon request | Example programs can be downloaded for free | Accelerates implementation and facilitates the transition to project-specific applications. |
| Firmware updates | Often paid or limited | Free for life | Ensures long-term functionality and enables improvements without additional licensing costs. |
| Example code | Fewer languages or restricted examples | Extensive examples for C, C++, C#, Java, VB, LabView | Supports various development environments and facilitates integration into existing software landscapes. |
| Response times | Partially higher latency with standard I/O | Very fast firmware | Improves real-time performance and enables reliable processing of time-critical signals. |
| System integration | Proprietary systems complicate integration | Easy integration into PLCs, PCs, and test benches | Facilitates integration into existing automation and test systems without extensive modifications. |
| Test system integration | Competitors often more expensive or less flexible | Ideal for automotive and test bench applications | Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments. |
Mechanical & physical properties |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
| Mounting | Depending on the supplier, different or less standard designs may be used. | Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I/O systems. | Enables quick and standards-compliant integration into existing control cabinets. |
Reliability |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
| Long-term availability | Typically 3–5 years | 10‑year guaranteed availability | Simplifies long-term plant planning and reduces risks associated with early product discontinuations. |
| Firmware updates | Often paid or limited | Free for life | Ensures continuous functional improvement without additional operating costs. |
| ICT tool | Often multiple tools, fewer functions | One tool for commissioning, diagnostics, loopback testing, long‑term simulation | Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution. |
| Production location | Many manufacturers produce in Asia | Made in Germany | Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts. |
| MTBF | Low-cost OEM modules with shorter lifespan | High MTBF values | Reduces the probability of failure and increases availability in continuous-operation applications. |
| Failure rate | Higher failure rates with low‑cost I/O | Very low field failure rates | Minimizes unplanned downtime and reduces maintenance and service costs. |
| Spare parts availability | Often early discontinuation | Long‑term spare parts availability | Facilitates maintenance and modernization of existing systems over many years. |
Service and support |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
| Support quality | Call centers or external service providers | Direct developer support | Enables fast and technically sound problem-solving without the need to escalate issues through external service providers. |
| Response time | Sometimes several days | Very fast response, often same day | Reduces downtime and speeds up the restoration of system operations when technical issues arise. |
| Customization | Rare or very expensive | Custom hardware/firmware possible | Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components. |
| Documentation | Often minimal or incomplete | Comprehensive and practical documentation | Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation. |
| Consulting | Often only sales support | Technicians instead of general sales staff | Ensures application-oriented support directly tailored to technical requirements. |
Economy |
|||
| Feature | Market Comparison | Advantages of the DEDITEC UC-CAN-AD2-16ISO</th > | Practical Benefits of the modules |
| Price-performance ratio | Major brands significantly more expensive | Very good price‑performance ratio | Reduces total cost per channel and enables cost-effective system expansions. |
| License costs | Modbus/features often require additional payment | No additional costs for protocols | Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions. |
| Series prices | Large manufacturers often inflexible | Attractive volume pricing | Simplifies budget planning for larger volumes and enables cost-effective scaling of projects. |
You might also like …
-
RO-CAN-16/32/64/128 * A/D input module with galvanically isolated A/D inputs (16 bit)
Price range: € 1.022,81 through € 6.370,67 Incl. 19% VAT plus shipping View Product -
UC-CANopen module with 2 analog inputs
Price range: € 770,53 through € 849,66 Incl. 19% VAT plus shipping View Product -
NET-DEV 16/18-bit A/D converter with galvanic isolation – 2 channels
Price range: € 770,53 through € 973,42 Incl. 19% VAT plus shipping View Product
You might also like …
-
NET-DEV 16/18-bit A/D converter with galvanic isolation – 2 channels
Price range: € 770,53 through € 973,42 Incl. 19% VAT plus shipping View Product -
RO-CAN-16/32/64/128 * A/D input module with galvanically isolated A/D inputs (16 bit)
Price range: € 1.022,81 through € 6.370,67 Incl. 19% VAT plus shipping View Product
Install the installation program and check the module functions.