User Account 1 1
Cart 0  0,00

CANopen A/D voltage reading * CANopen module with 16 analog inputs

The CANopen AD module enables the precise acquisition of voltages via high-resolution A/D converters and, thanks to galvanic isolation, provides reliable signal processing in industrial applications. It supports CiA profiles, can be flexibly configured, and operates reliably in a network of multiple CANopen modules. Typical applications include reading sensor voltages and monitoring analog measured variables in automation systems.

Price range: € 565,85 through € 608,69 Incl. 19% VAT plus shipping

SKU: UC-CANOPEN-AD16-16/18 Categories: ,

Our promise to you

Product Description – CANopen A/D module for reading voltage signals

The CANopen A/D module UC-CANOPEN-AD16-16/18 is a high-precision A/D acquisition module designed for industrial measurement and automation tasks. With 16 analog inputs and a choice of 16- or 18-bit resolution, the device enables extremely precise digitization of voltage and current signals. Voltage ranges from ±5 V to ±40 V and current ranges of 0–24 mA available—ideal for sensors, transducers, and process signals. Electrical isolation up to 500 V reliably protects connected systems and the module from interference and potential differences.

The electrical isolation of the inputs and the CAN bus ensures safe and interference-free signal processing, even in industrial environments with high EMC loads.
The module supports the CANopen profiles CiA 301, CiA 305, and CiA 401, allowing it to integrate seamlessly into existing CANopen networks. Node number and baud rate can be conveniently configured via DIP switches or LSS.

Typical applications include reading sensor voltages, monitoring analog measured variables such as temperature, pressure, or level, as well as use in test benches and industrial automation systems where reliable CANopen AD signal processing is required.

Standardized CANopen communication for industrial automation networks

The CANopen interface of the UC-CANOPEN-AD16-16/18 is based on the internationally established CiA® specifications 301, 305, and 401 and enables reliable and standardized integration into industrial fieldbus environments. By supporting CAN 2.0A and CAN 2.0B, a high level of compatibility with a wide range of control and automation systems is ensured. Galvanic isolation of the bus connection provides robust signal transmission and reliably protects communication against interference in harsh industrial environments. Device addressing is conveniently carried out via integrated rotary coding switches, allowing the node ID to be set directly on the device at hardware level, which enables fast commissioning without additional configuration software. In addition, the baud rate can be flexibly adapted to the respective network, ensuring easy integration into existing system architectures. Furthermore, the interface on the module supports data rates of up to 1 Mbit/s as well as features such as auto-baud detection to further simplify commissioning. This results in a powerful, stable, and standards-compliant communication solution that supports both fast installation and reliable operation in industrial environments.

Flexible control via CANopen for easy system integration

The control of the UC-CANOPEN-AD16-16/18 is fully based on the standardized CANopen protocol, enabling seamless integration into existing automation and control systems. By supporting the object-oriented communication model according to CiA 301, all functions are addressed and controlled via the Object Dictionary. Configuration is conveniently performed using standardized communication objects such as SDOs, while cyclic process data exchange via PDOs ensures fast and deterministic response in real-time operation.
In addition, the CANopen A/D module for reading voltage signals supports typical CANopen Network Management (NMT) functions, enabling defined start, stop, and error states of the device within the network. Flexible assignment of node ID and baud rate simplifies adaptation to different network topologies and control environments. Thanks to this consistent implementation of the CANopen standard, the module can be efficiently integrated into existing automation architectures and centrally operated via the control system.

Precise data acquisition with 16 analog inputs

The 16 galvanically isolated A/D inputs of the UC-CANOPEN-AD16-16/18 enable reliable acquisition of analog signals such as voltage and current. Typical sensors include temperature, pressure, or humidity sensors.
Thanks to versatile measurement ranges (0–5 V, 0–10 V, ±5 V, ±10 V, or optional current measurement) and high resolution, the IoT Analog Converter is particularly suitable for industrial measurement tasks with high demands for accuracy, stability, and flexibility.

Compact DIN rail design with modular system integration

Das CANopen A/D module for reading voltage signals ist für die Montage auf der DIN-Hutschiene ausgelegt und verfügt über ein kompaktes, industrietaugliches Gehäuse, das auf den Einsatz in rauen Automatisierungsumgebungen optimiert ist. Die elektrischen Anschlüsse sind über robuste, steckbare Klemmsysteme realisiert, die eine vibrationssichere Verdrahtung und eine schnelle Installation ermöglichen. Ein zentrales Merkmal ist der integrierte T-Bus, der als interner Systembus sowohl die Kommunikation als auch die Versorgungsspannung zwischen mehreren Modulen ohne zusätzliche Verdrahtung durchreicht. Dadurch entsteht eine durchgängige Backplane-Struktur, bei der Module mechanisch auf der Hutschiene verbunden und elektrisch automatisch gekoppelt werden. Der T-Bus reduziert den Verkabelungsaufwand erheblich und sorgt gleichzeitig für eine saubere, EMV-optimierte Systemarchitektur mit geringem Störpotenzial. Über die modulare Steckmechanik lassen sich weitere Teilnehmer einfach ergänzen, ohne das bestehende System neu verdrahten zu müssen. Die CANopen-Kommunikation des UC-CANOPEN-AD16-16/18 wird dabei nahtlos in diese T-Bus-Struktur eingebettet, wodurch eine skalierbare und systematisch aufgebaute Netzwerktopologie entsteht.
Zusätzlich verfügt das CANopen A/D module for reading voltage signals über integrierte Drehkodierschalter zur schnellen und einfachen Parametrierung direkt am Gerät. Über diese lassen sich zentrale Einstellungen wie beispielsweise die Node-ID ohne Softwarezugriff konfigurieren. Dies ermöglicht eine besonders schnelle Inbetriebnahme sowie eine eindeutige Geräteadressierung im Feld. Die Einstellung erfolgt dabei robust und manipulationssicher, auch im spannungslosen Zustand.

User Benefits and Practical Application

The UC-CANOPEN-AD16-16/18 offers a practical solution for industrial control and monitoring tasks. Its rugged, galvanically isolated electronics ensure reliable operation, while the documentation, drivers, and ICT diagnostic tool enable quick integration. Thanks to regular updates and direct developer support, the module remains operational over the long term and supports sustainable planning in professional environments.

Technical Specifications

The module offers 16 high-resolution 16-bit A/D channels for the precise acquisition of analog voltages across various measurement ranges. Electrical isolation ensures interference-free signal processing, while CANopen integration in accordance with the CiA standard enables reliable integration into industrial networks. Typical applications include the acquisition of analog sensor signals and the monitoring of process values in automation systems.

CANopen interface:

  • CANopen profiles according to CiA® specifications CiA 301, CiA 305, and CiA 401
  • CAN 2.0A or CAN 2.0B
  • Electrically isolated up to 500 V
  • Configurable via DIP switches
  • 1 Mbit/s, 800 Kbit/s, 500 Kbit/s, 250 Kbit/s, 125 Kbit/s, 100 Kbit/s, 50 Kbit/s, 20 Kbit/s, 10 Kbit/s, auto baud

16-bit analog inputs:

  • Design: single-ended
  • 16-bit resolution per channel
  • Voltage ranges: 0–5 V, 0–10 V, ±5 V, ±10 V
  • Optional voltage ranges: 0–20 V, 0–40 V, ±20 V, ±40 V
  • Optional current ranges: 0–20 mA, 4–20 mA, 0–24 mA
  • Electrical isolation for the power supply: max. 500 V
  • A/D converter conversion time: 4 µs

18-bit analog inputs:

  • Design: single-ended
  • 18-bit resolution per channel
  • Voltage ranges: ±5 V, ±10 V
  • Electrical isolation for the power supply: max. 500 V
  • A/D converter conversion time: 4 µs

Analog inputs

Analog/digital converter modules are suitable for measuring and monitoring voltages and currents. Transducers, for example, convert physical variables such as pressure, temperature, humidity etc. into corresponding currents or voltages and can therefore be recorded and digitally processed with our A/D modules.

Symbole analoge Eingänge

Plug connector

A screwless system from the manufacturer WAGO® Kontakttechnik is used as the connector. The 1-wire female connectors are 100 % protected against mismating and have an ejection and locking mechanism.

Symbol für Steckverbinder


Easy installation thanks to DIN rail bus

Thanks to the practical bus connector, which is clipped into the DIN rail, individual modules of a system can be added or replaced very easily. This Plug'n Play principle makes commissioning easier for you and eliminates the need for tedious wiring.

din_rail_bus_1024q


LEDs

Each digital input and output has a separate LED that lights up when the signal status is active. The status of the operating voltage, communication with the interface, error events or the occurrence of a timeout can also be displayed.

Symbol für LEDs

General information

Power supply as a stand-alone device +7 V DC ... +24 V DC
Power supply as a combined device Externally via the DIN rail connector
LEDs general
  • Green = CANopen RUN -> Indicates the current CANopen status of the module (e.g. “preoperational” or “stopped”).
  • Red = CANopen ERR -> Indicates an error, e.g. faulty CAN-BUS wiring
  • Yellow = Power/Status -> Lights up when power supply = ok
  • U mode active / not active
  • I mode active / not active
  • Read/write access to the A/D converter
LEDs product-specific

UC-CANOPEN-AD2:

  • A/D channel active / not active

 

UC-CANOPEN-AD16:

  • Extended voltage range (U-E) active / not active
  • 16-bit mode active / not active
  • 18-bit mode active / not active
  • 20-bit mode active / not active
   
Bus connector (optional)
  • Bus connector for clipping into the top-hat rail
  • Plug and play connection of several DEDITEC CANopen modules
  • CAN-High, CAN-Low
  • +24 V, GND
DIN rail mounting 35 x 7,5 mm
Operating temperature +10 °C ... +50 °C


Interfaces

CANopen Interface

CANopen interface
  • CANopen (galvanically isolated up to 500 V)
  • CANopen profiles according to CiA® specification CiA 301, CiA 305 and CiA 401
  • CAN 2.0A or CAN 2.0B
NODE-ID Configurable via coding switch
Baud rates

Configurable via coding switch

  • 1 Mbit/s
  • 800 Kbit/s
  • 500 Kbit/s
  • 250 Kbit/s
  • 125 Kbit/s
  • 100 Kbit/s
  • 50 Kbit/s
  • 20 Kbit/s
  • 10 Kbit/s
  • Autobaud


Inputs/Outputs

Analog inputs

Inputs
  • 16 A/D channels (single ended)
  • Resolution: 16-bit or 18-bit per channel
  • Measuring ranges 16-bit version:
    0-5 V, 0-10 V, 0-20 V*, 0-40 V*, +-5 V, +-10 V, +-20 V*, +-40 V*
    0-20 mA, 4-20 mA, 0-24 mA, 0-50 mA**
  • Measuring ranges 18-bit version:
    +-5 V, +- 10 V
  • Input resistance: >500 kOhm
  • Accuracy: +3 ppm / °C
  • Zero error temperature drift: +1 ppm / °C
  • Full-scale error temperature drift: + 1 ppm / °C
  • Bipolar Full-Scale Error: Min: - 50 LSB / Max: +50 LSB
  • Unipolar Full-Scale Error: Min: - 70 LSB / Max: +70 LSB

* is not supported by modules of the BS-WEU series
** is only supported by modules of the BS-WEU series

Conversion rates
  • A/D converter conversion rate: 4 µs
  • Conversion rate of the module (all 16 A/D channels are converted):
    78 conversions / second with A/D filter level switched off (filter level = 0)
    48 conversions / second with an A/D filter level of 10
Galvanic isolation For power supply: max. 500 V
A/D-Filter
  • Electrical or electromagnetic interference in measurement signals is smoothed and optimised by the software-side A/D filter by averaging the measurements
  • Filter level 0 at module start (= filter deactivated)
  • Can be set via DELIB commands:Set: DapiSpecialCommand(handle, DAPI_SPECIAL_CMD_AD, DAPI_SPECIAL_AD_FILTER_SET, ((filterlevel & 0xff) << 8) | (submodule_nr & 0xff) , 0)Read back: DapiSpecialCommand(handle, DAPI_SPECIAL_CMD_AD, DAPI_SPECIAL_AD_FILTER_GET, (submodule_nr & 0xff) , 0)


Connectors

Plug connector 18-pin
  • Type: Wago contact technology 713-1109/037-000
  • Pluggable female connector with locking mechanism
  • 100 % protected against mismating
  • 1-wire connection for all conductor types up to 1.5 mm²
Plug connector 5-pin
  • Type: Phoenix Contact 1876343
  • Pluggable screw terminal
  • 100 % mismating protected
  • For all conductor types from 0.14 mm² to 1.5 mm²

Configuration of CANopen modules

The CANopen interface is configured via the CANopen bus of the module and via three rotary coding switches located on the front of the module.
The upper and middle rotary coding switches determine the node ID, the lower one the baud rate.

Icon Canopen

Rotary coding switch

In this example, the operating mode is CANopen, the bit rate is 250 kBit/s and the node ID is 0x24.
 
The upper rotary coding switch determines the high-order bits and the middle switch the low-order bits.
The lower rotary coding switch is used to set the baud rate, the following is a list of all settings:
Cos Konfiguration 615 464

Meaning of lower rotary switch:

Value Operating mode Description
0 CANopen Bitrate = 1000 kBit/s
1 CANopen Bitrate = 800 kBit/s
2 CANopen Bitrate = 500 kBit/s
3 CANopen Bitrate = 250 kBit/s
4 CANopen Bitrate = 125 kBit/s
5 CANopen Bitrate = 100 kBit/s
6 CANopen Bitrate = 50 kBit/s
7 CANopen Bitrate = 20 kBit/s
8 CANopen Bitrate = 10 kBit/s
9 CANopen Autobaud + LSS
A CANopen Autobaud
B CANopen Bootloader Bitrate = 250 kBit/s
C CANopen Bootloader Bitrate = 1000 kBit/s, Node ID = 0x7e
D CAN 2.0 A/B Use settings from EEPROM
E CAN 2.0 A/B Bitrate = 1000 kBit/s, CAN ID = 0x100
F CANopen Bitrate = 1000 kBit/s, CAN ID = 0x7e

Control of CANopen modules

The CANopen modules are controlled via a so-called object directory. Standardized communication objects such as PDOs and SDOs are used for this purpose.

Icon Canopen

EDS
Select the EDS file for your module to load all the registers required for the controller.

Canopen Explorer Eds

Read register
Under the "Device Profile Segment" tab, you will find all the registers for controlling the module.
In register 0x6200 it is possible to write or read the states of the relays.
In the example, the status of the first 8 relays is read.

Canopen Explorer Read

Write register
Under the "Device Profile Segment" tab, you will find all the registers for controlling the module.
In register 0x6200 it is possible to write or read the states of the relays.
In the example, the status of the first 8 relays is written.

Canopen Explorer Write

Connection example AD16:

Connection example

Screwless connector system

The customer-side connection wiring of the inputs and outputs is carried out using screwless, pluggable terminal strips. The conductor connection is made using a so-called actuating tool.
A locking and ejecting mechanism facilitates the insertion and removal of the complete terminal strip.

Handling:

Steps 1-5

Step 1

See the scope of delivery for the operating tool.

Wago Betaetigungswerkzeug 615 464 Kopie
Step 2

Insert the operating tool firmly into the side opening in the direction of the conductor connection.

Konf Werkz Montage2 615 464 Kopie
Step 3

Now insert the stripped conductor into the open clamp contact.

Konf Werkz Montage3 615 464 Kopie
Step 4

Pull out the operating tool again.

Konf Werkz Montage4 615 464 Kopie
Step 5

Check that the conductor is properly connected. It should now no longer be possible to pull it out easily.

Konf Werkz Montage5 615 464 Kopie

Manual

DDT Icons Downloads PDF Transparent 250606

Manual UC-CANopen modules

Quickstart - Hardware description - CANopen protocol
Commissioning/Quickstart

  • Safety instructions
  • Connecting the power supply
  • Installation
  • Connecting the I/O connectors

Hardware description

  • List of technical data
  • Definition of the LEDs
  • Pin assignment of the connectors
  • Connection examples

CANopen protocol

  • Identifier
  • Network management
  • Information on communication, manufacturer and device profile
  • Access via SDOs
  • Device monitoring
  • Information on the CAN bus length

UC-CANopen firmware

DDT-Icons-Downloads_ZIP_transparent_250606

UC-CANopen firmware files

This ZIP file contains all firmware files for the UC-CANopen series.

You can use these files to renew or update the firmware of your CANopen module.


CANopen EDS files

DDT-Icons-Downloads_ZIP_transparent_250606

CANopen EDS files

This ZIP file contains all EDS files for the CANopen modules.

The EDS files are used to control a CANopen module.

5-pin plug connector

Enables the power supply to be connected to the DEDITEC module.

  • Type: Phoenix Contact® - 1876343
  • 100 % mismatch protected
  • For all conductor types from 0.2 mm² to 2.5 mm²
Zbh Steck 05 Gew 600

16-pin plug connector

Required for connecting inputs and outputs of the DEDITEC module.

  • Type: WAGO® 713-1108/037-000
  • Plug-in female multipoint connector with locking mechanism
  • 100 % mismatch protected
  • 1-wire connection for all conductor types up to 1.5 mm²
ZBH STECK 16 AUSW 600


Actuating tool for Wago connectors

Used to open and close the terminal contacts on the WAGO® connectors.

  • Type: WAGO® - 734-231
Zbh Steck Werkz 600


DIN-Rail connector

The DIN rail connector is a single BUS segment that enables connection to other modules. It is clipped into the top-hat rail and plugged onto the side of an existing DIN rail connector.

  • Type: Phoenix Contact® - 2203852
  • Connection of a NET or UC module
  • For expanding the NET or UC bus system
  • 1 Piece
Din Rail Bus 615 464

5-pin plug connector

Enables the power supply to be connected to the DEDITEC module.

  • Type: Phoenix Contact® - 1876343
  • 100 % mismatch protected
  • For all conductor types from 0.2 mm² to 2.5 mm²
Zbh Steck 05 Gew 600

16-pin plug connector

Required for connecting inputs and outputs of the DEDITEC module.

  • Type: WAGO® 713-1108/037-000
  • Plug-in female multipoint connector with locking mechanism
  • 100 % mismatch protected
  • 1-wire connection for all conductor types up to 1.5 mm²
ZBH STECK 16 AUSW 600


18-pin plug connector

Required for connecting inputs and outputs of the DEDITEC module.

  • Type: WAGO® - 713-1109/037-000
  • Plug-in female multipoint connector with locking mechanism
  • 100 % mismatch protected
  • 1-wire connection for all conductor types up to 1.5 mm²
ZBH STECK 18 AUSW 600


Actuating tool for Wago connectors

Used to open and close the terminal contacts on the WAGO® connectors.

  • Type: WAGO® - 734-231
Zbh Steck Werkz 600


DIN-Rail connector

The DIN rail connector is a single BUS segment that enables connection to other modules. It is clipped into the top-hat rail and plugged onto the side of an existing DIN rail connector.

  • Type: Phoenix Contact® - 2203852
  • Connection of a NET or UC module
  • For expanding the NET or UC bus system
  • 1 Piece
Din Rail Bus 615 464


Strain relief plate for 16 or 18-pin Wago connectors

The strain relief plate is pushed onto the center of the female connector and enables the connected cables or strands to be fixed in place.

  • Type: WAGO® - 713-127
  • Strain relief for the connection wiring
  • Suitable for 16 or 18-pole female connectors
  • Slide onto the female connector from the side
ZBH STECK PL 16
ZBH STECK PL 16 Wago


Top hat rail

Top-hat rail for mounting our control technology modules.

  • DIN rail according to DIN EN 50022
  • Type: Phoenix Contact® - 1208131
  • Dimensions in mm: 450 x 35 x 7.5 (L x W x H)
Zbhhutschiene 1m 600


24V/2A power supply unit for top-hat rail mounting

The DR-4524 from Mean Well is a 48W power supply unit for DIN rail mounting for industrial applications. It offers protection against short circuit, overload, overvoltage and overheating.

  • Input voltage range: 85 V.. 264 V AC / 120 V DC ... 370 V DC
  • Output voltage: 24 V DC
  • Output current: 2 A
  • Rated power: 48 W
Zbhnetzteil 24v 2a 600

Typical Application Areas:

  • Standardized automation networks (CiA 301/401):
    The CANopen A/D modules for reading voltage signals is ideally suited for standards-based CANopen networks in industrial applications. Thanks to support for established CiA profiles, it can be seamlessly integrated into existing automation systems.
  • Decentralized machine control in a CANopen network:
    In CANopen structures, the UC-CANOPEN-AD16-16/18 can act as an intelligent network participant and support synchronized processes with other nodes in machines and systems.
  • System networking in industrial production:
    Perfect for structured networking of multiple machines or plant sections via CANopen. This enables scalable and modularly expandable production systems.
  • Synchronized real-time process communication:
    CANopen enables deterministic communication between multiple participants. This makes the CANopen A/D module for reading voltage signals suitable for time-critical control and synchronization tasks within the system network.
  • Diagnostics and network management in CANopen systems:
    By integrating into CANopen structures, the CANopen A/D module for reading voltage signals can also contribute to network diagnostics and monitoring of communication states within the overall system.
  • Building and environmental automation:
    Continuous monitoring of climate and environmental sensors in large building complexes is easily possible with the UC-CANOPEN-AD16-16/18.
  • Laboratory and testing technology:
    The CANopen A/D module for reading voltage signals is ideally suited for experimental setups, data acquisition, and calibrations where high accuracy and reliability are essential.
  • Machine and plant networking:
    Integration of analog measurement values into control and SCADA systems.
  • Energy and consumption monitoring:
    The inputs of the UC-CANOPEN-AD16-16/18 can be used to record current, voltage, or power values in order to monitor energy flows in systems.

Comparison of UC-CANOPEN-AD16-16/18 with common market products

</tr ></tr ></tr ></tr ></tr ></tr ></tr ></tr >

Interfaces & Communication

Feature Market Comparison Advantages of the DEDITEC UC-CANOPEN-AD16-16/18</th > Practical Benefits of the modules
Galvanic isolation of the CAN interface A galvanically isolated CAN interface is not standard on all devices. Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments. Improves interference immunity and protects communication in harsh industrial environments.

Analog inputs

Feature Market Comparison Advantages of the DEDITEC UC-CANOPEN-AD16-16/18</th > Practical Benefits of the modules
Resolution and accuracy Typically 8–12 bit High‑resolution 16‑bit for precise signal control Improves measurement accuracy and enables reliable evaluation of even small signal changes.
Galvanic isolation Often, there is no isolation from the power supply Electrical isolation for the module’s power supply Protects connected systems from interference voltages and prevents interactions between measurement circuits and the power supply.

Hardware flexibility

Feature Market Comparison Advantages of the DEDITEC UC-CANOPEN-AD16-16/18</th > Practical Benefits of the modules
Supply voltage Usually fixed (e.g., +24 V) Flexible +12 V DC … +28 V DC Facilitates use in various power supply configurations and reduces the need for additional power supplies.
EMC stability Low-cost OEM modules often susceptible to interference Industrial‑grade EMC design Ensures low-interference operation in industrial environments with high electromagnetic interference.

Software & Integration

Feature Market Comparison Advantages of the DEDITEC UC-CANOPEN-AD16-16/18</th > Practical Benefits of the modules
System integration Proprietary systems complicate integration Easy integration into PLCs, PCs, and test benches Facilitates integration into existing automation and test systems without extensive modifications.
Test system integration Competitors often more expensive or less flexible Ideal for automotive and test bench applications Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.

Mechanical & physical properties

Feature Market Comparison Advantages of the DEDITEC UC-CANOPEN-AD16-16/18</th > Practical Benefits of the modules
Mounting Depending on the supplier, different or less standard designs may be used. Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I/O systems. Enables quick and standards-compliant integration into existing control cabinets.

Reliability

Feature Market Comparison Advantages of the DEDITEC UC-CANOPEN-AD16-16/18</th > Practical Benefits of the modules
Long-term availability Typically 3–5 years 10‑year guaranteed availability Simplifies long-term plant planning and reduces risks associated with early product discontinuations.
Firmware updates Often paid or limited Free for life Ensures continuous functional improvement without additional operating costs.
Production location Many manufacturers produce in Asia Made in Germany Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.
MTBF Low-cost OEM modules with shorter lifespan High MTBF values Reduces the probability of failure and increases availability in continuous-operation applications.
Failure rate Higher failure rates with low‑cost I/O Very low field failure rates Minimizes unplanned downtime and reduces maintenance and service costs.
Spare parts availability Often early discontinuation Long‑term spare parts availability Facilitates maintenance and modernization of existing systems over many years.

Service and support

Feature Market Comparison Advantages of the DEDITEC UC-CANOPEN-AD16-16/18</th > Practical Benefits of the modules
Support quality Call centers or external service providers Direct developer support Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.
Response time Sometimes several days Very fast response, often same day Reduces downtime and speeds up the restoration of system operations when technical issues arise.
Consulting Often only sales support Technicians instead of general sales staff Ensures application-oriented support directly tailored to technical requirements.

Economy

Feature Market Comparison Advantages of the DEDITEC UC-CANOPEN-AD16-16/18</th > Practical Benefits of the modules
Price-performance ratio Major brands significantly more expensive Very good price‑performance ratio Reduces total cost per channel and enables cost-effective system expansions.
Series prices Large manufacturers often inflexible Attractive volume pricing Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.
My cart
Your cart is empty.

Looks like you haven't made a choice yet.