CAN analog converter * 16-bit D/A converter – 4/8 channels

The UC-CAN-DA4/8 is a high-performance CAN-to-analog converter with 4 or 8 precise D/A channels for outputting voltages. It is ideal for industrial automation and flexible signal generation. Typical applications include the simulation of sensor signals in test benches and the control of analog actuators in CAN-based control systems. Rugged, galvanically isolated, and perfect for demanding measurement and test environments.

Price range: € 447,44 through € 613,06 Incl. 19% VAT plus shipping

SKU: UC-CAN-DA4/8_16 Categories: ,

Our promise to you

Product Description – CAN analog converter module

The UC‑CAN‑DA4/8 is a versatile CAN analog converter designed specifically for industrial applications requiring precise analog output signals. With a choice of 4 or 8 galvanically isolated D/A channels, the module enables the reliable output of signal voltages, making it ideal for automation, test systems, and demanding measurement environments. The galvanic isolation protects connected systems from interference and potential differences, ensuring maximum operational reliability.
The CAN analog converter module can be flexibly integrated into existing networks via the CAN interface. The adjustable baud rate, automatic RX/TX mode, and clearly structured CAN logging simplify implementation in a wide variety of control and test architectures. Thanks to its high resolution and fast response times, the device is ideally suited for simulating sensor signals, controlling analog actuators, or precisely setting process variables.
The robust industrial design ensures reliable operation even under harsh environmental conditions. Thanks to its compact design, the UC-CAN-DA4/8_16 can be easily integrated into distributed systems. Whether in test benches, laboratory environments, or industrial CAN networks—the UC-CAN-DA4/8 offers a powerful, durable, and flexible solution for all applications requiring precise analog output signals.

CAN interface with flexible USB configuration

The CAN interface of the UC-CAN-DA4/8_16 is based on the CAN 2.0A/B standard and enables robust, error-resistant communication in industrial networks. It supports the typical multi-master CAN bus architecture, allowing multiple nodes to efficiently exchange data without a central controller. The bit rate is flexibly configurable, enabling the CAN analog converter module to be easily adapted to different network speeds and system environments. Communication is handled via standardized CAN telegrams with event-driven data transmission for fast and reliable signal processing.
The entire CAN configuration, including TX/RX behavior, is conveniently carried out via the integrated USB interface on a PC. This allows parameters such as bus speed and message handling to be quickly configured and tested. This combination of CAN and USB connectivity significantly simplifies commissioning and reduces integration and diagnostic effort.

Flexible CAN control via auto TX/RX and DELIB command mode

The control of the UC-CAN-DA4/8_16 is generally based on two operating modes: the Auto TX/RX mode and the DELIB command mode. In Auto TX/RX mode, the module can automatically send and receive CAN messages without the need for a continuously connected control PC.
Alternatively, the DELIB command mode provides direct register-based access via a proprietary CAN protocol, where specific commands are transmitted to the CAN analog converter module. Read and write operations are implemented using defined CAN IDs and structured data packets, enabling highly flexible and precise control.
Configuration of these operating modes is conveniently performed, depending on the product variant, via the integrated USB or Ethernet interface on a PC. Using the corresponding tool, parameters such as communication behavior, TX/RX logic, and DELIB command structure can be easily set up and tested. This allows the CAN analog converter module to be quickly adapted to different applications and efficiently integrated into existing CAN systems.

High-precision analog outputs for industrial control and regulation applications

The UC-CAN-DA4/8_16 provides, depending on the variant, 4 or 8 high-resolution analog outputs designed for demanding automation and control tasks. Each channel features 16-bit resolution, enabling particularly fine and precise signal generation. The outputs on the CAN analog converter module can be flexibly operated as voltage or current interfaces and support common ranges such as 0–10 V, ±10 V, and 0/4–20 mA. This allows a wide variety of actuators such as control valves, drives, or process control systems to be precisely controlled.
Thanks to the high conversion speed and stable signal quality, even dynamic control processes can be reliably implemented. In addition, galvanic isolation between output groups ensures robust and interference-resistant integration in industrial environments.

M2M communication – direct device-to-device networking

The M2M (machine-to-machine) function enables direct communication between multiple modules or systems without a central control unit. States and events can be automatically exchanged and synchronized between devices, allowing the creation of distributed and autonomously operating automation structures. Communication is carried out via defined protocols and can be flexibly integrated into existing system architectures. As a result, M2M is particularly well suited for connected industrial and IoT applications.

Robust industrial design with a well-engineered connection and mounting architecture

The CAN analog converter module is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-CAN-DA4/8_16, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm². In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.

Reliability and Industrial Quality

With the UC-CAN-DA4/8_16, users get a reliable industrial module designed for continuous use in demanding automation projects. German engineering, galvanic isolation, and robust electronics ensure a high level of safety and stability. Clear documentation, stable drivers, and the ICT diagnostic tool make it easy to integrate and operate the module efficiently. Long-term updates and direct support round out this professional package.

Technical Specifications

The UC-CAN-DA4/8 analog converter offers 4 or 8 galvanically isolated 16-bit D/A channels for precise voltage outputs. It supports 0–5 V, 0–10 V, +5 V, and +10 V. Robust galvanic isolation up to 1 kV ensures reliable signal transmission in industrial applications. The CAN interface allows the module to be reliably integrated into automation and control systems, delivering stable output signals for professional industrial environments.

Ethernet interface:

  • Ethernet 10/100 Mbps
  • Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP
  • Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP
  • Encrypted Ethernet communication possible
  • Open standard or Modbus TCP protocol
  • Web interface and app (smartphone and tablet)
  • Electrically isolated up to 1.5 kV

Wi-Fi interface:

  • Wi-Fi connection available
  • WPS feature

USB interface:

  • USB 2.0 interface up to 480 Mbit/s
  • Quick setup thanks to plug-and-play integration
  • Control: API for Windows and Linux (DELIB driver library), command-line interface

CAN interface:

  • CAN interface according to ISO 11898
  • Open CAN protocol (RAW CAN)
  • Automatic transmit/receive mode
  • Electrically isolated up to 500 V

Analog outputs:

  • 16-bit resolution per channel
  • Voltage ranges: 0–5 V, 0–10 V, ±5 V, ±10 V
  • Isolation from power supply: max. 500 V AC
  • D/A converter conversion time: 10–12 µs
  • Load resistance: ≥ 2 kΩ

Additional features:

  • Configurable event control
  • M2M functionality

Analog outputs

Our digital/analog converters enable the precise control of current- or voltage-controlled actuators such as valves or servomotors. They ensure reliable and interference-free signal transmission, particularly in industrial environments with long distances. This makes them ideal for demanding applications in automation technology.

Symbole analoge Ausgänge

Fail-Safe Mode

The Fail-Safe mode is a safety function in which the DEDITEC module switches to a previously configured, safe switching state in the event of a connection failure.
This is intended to prevent connected installations or systems from continuing to run in an uncontrolled manner.

Symbol für den Fail-Safe Modus


Automatic transmit and receive mode

Use our Auto TX/RX mode and automate the workflow of your DEDITEC product by automatically processing or sending CAN packets from other participants in the network. With our free ICT-Tool, you can define how the TX and RX packets should be processed via a graphical user interface.

Symbol für CAN RX-TX Modi


Plug connector

A screwless system from the manufacturer WAGO® Kontakttechnik is used as the connector. The 1-wire female connectors are 100 % protected against mismating and have an ejection and locking mechanism.

Symbol für Steckverbinder


Easy installation thanks to DIN rail bus

Thanks to the practical bus connector, which is clipped into the DIN rail, individual modules of a system can be added or replaced very easily. This Plug'n Play principle makes commissioning easier for you and eliminates the need for tedious wiring.

din_rail_bus_1024q


LEDs

Each digital input and output has a separate LED that lights up when the signal status is active. The status of the operating voltage, communication with the interface, error events or the occurrence of a timeout can also be displayed.

Symbol für LEDs


M2M

Machine-to-machine, or M2M for short, involves direct communication between two or more modules. Analog or digital input signals from one transmitter module can be automatically transmitted to another module on a channel-by-channel basis.
M2M transmission is supported by all our products in the WEU series or by products with a CAN interface.

Symbol für M2M


Event-Control

This function can be used to implement small control tasks that are saved in the module. These control tasks are configured as events and actions and then executed automatically according to the “if-then” principle.

Symbol für Event-Control

Power supply +12 V ... +24 V DC
LEDs general
  • Interface communication
  • Module status
  • One LED per input and output channel (only for digital modules)
LEDs product-specific

A/D-version:

  • A/D channel active / not active
  • Read/write access to A/D channel
  • U mode active / not active
  • I mode active / not active

D/A-version:

  • D/A channel active / not active
  • Read/write access to D/A channel
  • U mode active / not active

Thermo version:

  • A/D channel active / not active
  • Read/write access to A/D channel
  • U mode active / not active
  • I mode active / not active

 

DIN rail mounting 35 x 7,5 mm
Operating temperature +10 °C ... +50 °C
Dimensions 120 mm x 22.5 mm x 111 mm (H x W x D)

Special features

Event-Control With our event control, you have the option of linking occurring events to a specific action. With the help of our ICT tool, the control tasks can be stored directly in the module memory thanks to an intuitive “if-then” logic. Monitor, control and regulate without an additional control PC.

Fail-Safe-function

FAIL-SAFE-function
  • Simple and uncomplicated setting of the timeout protection function possible via software
  • Time-definable automatic activation of the timeout protection function in the event of a timeout (between 0.1 seconds and 6553 seconds)
  • In the event of a timeout, digital outputs can be activated, deactivated or left unchanged
Timeout-mode "Normal" The "Normal mode" is valid once and must be reactivated manually by software command after each timeout event. The customer application still has access to all controller outputs.
Timeout-mode „Auto reactivate“ In “Auto reactivate mode”, the timeout function is automatically reactivated once communication with the control PC has been re-established. The customer application still has access to all outputs of the control unit.
Timeout-mode "Secure Outputs" The “Secure outputs mode” blocks access to the outputs after the timeout event. Unlocking can only be carried out by software command. This is an important safety aspect in the event of a fault.


Interfaces

CAN Interface

CAN-Interface
  • Connection: 9-pin D-Sub socket
  • CAN 2.0A or 2.0B
  • 1 Mbit/s, 500 Kbit/s, 250 Kbit/s, 125 Kbit/s, 100 Kbit/s, 50 Kbit/s, 20 Kbit/s or 10 Kbit/s
  • Galvanically isolated up to 500 V
  • Open CAN protocol
  • Automatic processing of CAN packets (Auto TX/RX mode)

USB Interface

USB-interface
  • Connection: Type C
  • USB 2.0 / USB 1.1 interface with up to 480 Mbit/s
Access speed
  • USB: 2,06 ms

    Calculated with 1000 accesses to the module via the DELIB driver library with the command DapiDoSet32


Inputs/Outputs

Analog outputs

Output
  • D/A channels with 16-bit resolution each
  • Voltage ranges: 0-5 V, 0-10 V, ±5 V, ±10 V
  • Relative Accuracy: Min: -16 LSB / Max: +16 LSB
  • Bipolar Zero Error (T = 25°C): ±4 ppm FSR / °C
  • Zero-scale error (T = 25°C): ±2 ppm FSR / °C
  • Full-scale error temperature drift: ±1 ppm / °C
Galvanic isolation
  • Channel 1 ... 4 to channel 5 ... 8: max. 1000 V AC*
  • For power supply: max. 500 V AC*

* only applies to modules of the NET series and the UC-CANOPEN series

Load resistance > 2 KOhm
Conversion rate 10-12 µs conversion time of the D/A converter
   
   


Connectors

Plug connector 16-pin
  • Type: Wago contact technology 713-1108/037-000
  • Pluggable female connector with locking mechanism
  • 100 % protected against mismating
  • 1-wire connection for all conductor types up to 1.5 mm²
Plug connector 5-pin
  • Type: Phoenix Contact 1876343
  • Pluggable screw terminal
  • 100 % mismating protected
  • For all conductor types from 0.14 mm² to 1.5 mm²

The ICT-Tool

Integration, configuration and testing - Our all-in-one Windows tool contains all the functions you need to put our products into operation quickly, easily and efficiently. Start with the setup and configuration, install firmware updates and use the extensive test and diagnostic options. The integrated help menu provides additional support if required.

Below you will find a brief overview of the program’s basic menus.

Module selection
Here you can integrate a new product into the ICT tool by clicking on the “+” symbol and then configure it.

ICT TreeView
In the TreeView, on the left-hand side of the program window, you can see the respective control elements or functions that are supported by your selected module. The scope of the functions depends on the respective product.

Overview
All relevant module information can be accessed here at a glance.

  • Module name
  • Module ID
  • Firmware revision
  • MAC address
  • LAN and WiFi Network address (module dependent)

Inputs / Outputs
This overview shows the number of I/Os supported by your module.

Module infos
Here you will find all the important feature information for your module.

General features
Here you will find all the important feature information for your module.

Digital I/O features
Here you will find information about the digital I/Os supported by the module.

Analog I/O features

Here you will find information about the type of analog I/Os supported by your module.

Special I/O features

Here you will find information about the type of special I/Os supported by your module.

In den folgenden Kapitel, würden wir Ihnen unsere neue All-In-One-Software gerne genauer vorstellen.

Info
All relevant module information can be called up here at a glance.

  • Module name
  • Module ID
  • Firmware revision
  • Interface type
  • Current DIP switch setting (only for Ethernet modules)

Identification
If several DEDITEC Ethernet modules are active in the network, a signal LED on the selected module can be activated via an identification function. This facilitates visual assignment.

Restart
You can restart your module here. The module status shows whether the restart was successful.

USB configuration
If you want to use several USB modules from the same product series on one PC, each of these modules must first be assigned its own module number.

LAN info
On this information page, you will find the current LAN network information and all the settings for your module at a glance.

LAN configuration
Integrate the product into your network or control it directly via a 1-to-1 connection.
The following parameters can be changed.

  • Board name
  • DHCP on/off
  • IP address
  • Subnet mask
  • Default gateway
  • TCP Port

WiFi info
All important WiFi settings are displayed on this page

WiFi configuration
Here you can change the network settings of the selected WiFi product.

The following settings can be made:

  • Board name
  • WLAN on/off
  • Router name
  • Router password

WPS
With the WPS function, your module can be connected to the router quickly and easily, automatically (WPS on the router is required)

CAN configuration
With our CAN products in the BS, NET and UC series, settings for the interface and the TX/RX packets can be made using the ICT tool.

More information can be found here:

Serial configuration
For our serial products in the BS, NET, UC and RO series, changes to the interface can be made using the
ICT tool.

More information can be found here:

Modbus TCP
Here you can set the Modbus TCP configuration of the module.
 
The following configurations can be made.

  • Enable/disable access via Modbus TCP
  • TCP port

TCP encryption
Here you can make settings for the encryption of your module.

The following configurations can be made.

  • Allow unencrypted protocol
  • Allow “User” encryption mode
  • User password
  • Allow “Admin” encryption mode
  • Admin password

NTP configuration
You can make changes to the NTP service here.

The following configurations can be made.

  • NTP service on/off
  • server
  • Port
  • Timezone

WEB-Login
Here you can change the login settings of the web interface.

The following configurations can be made.

  • Session duration
  • Login name
  • Login password
  • Allow I/O access via web interface

D/A Default Values
Here you can set the D/A values and modes with which the module should be started.
The value and mode can be set individually for each channel.

Watchdog configuration
Here you can make and save settings on your watchdog stick.

Save or Load config
Using the “Save or Load config” function, you can save your entire module configuration in an external XML file.
This means you can always load your module in the desired original state.

The following configurations can be saved depending on the module type.

  • USB configuration
  • LAN configuration
  • WiFi configuration
  • TCP encryption
  • NTP configuration
  • Serial configuration
  • CAN configuration

 

Status
This gives you an overview of the activity of the transmitter and receiver module

The following information from the transmitter module is displayed:

  • Status of the activity: If the check mark is set, this action is currently being performed.
  • Total number of actions performed. Is reset to 0 after a restart of the module.
  • Number of actions per second.
  • Number of DELIB errors that occur when executing commands from the DEDITEC driver library.

The following information from the receiver module is displayed:

  • Connected: If the check mark is set, the transmitter and receiver modules are connected.
  • IP address of the receiver module.
  • Number of connection attempts.

 

Receiver modules
You can set the network settings of the receiver module here.

The following settings can be made

  • Name for the receiver module
  • Network settings of the receiver module
  • Timeout
  • Encryption type/ password

Action
With an action, you define which input signal is to be sent from the transmitter module to which output of a receiver module.

The following settings can be made:

  • Type of task (digital, analog)
  • Which receiver module should be used
  • The interval at which the operations are to be carried out
  • Start channel of the transmitter module
  • Number of channels to be transmitted
  • Start channel of the receive module

In the image on the right, DI data is sent every 100ms from channel 3(CH Start) to channel 8 ((CH Start) + (CH Count)) to channels 0-5 of the target module.

 

In den folgenden Kapitel, würden wir Ihnen unsere neue All-In-One-Software gerne genauer vorstellen.

Status
The Status area provides an overview of all active events and executed actions.

The following information is listed:

  • Event number
  • Event type
  • Time interval of the event
  • Number of events that have occurred
  • Action number
  • Number of triggered actions
  • Number of other actions

Events configuration
Up to 16 different events can be created in the configuration menu. An event can be used, for example, to define switching thresholds at the analog inputs or logical states at the digital inputs of the module and link them to an executable action. The configuration itself is saved permanently in the module configuration memory of the module.

The following event modes are available, depending on the module type:

  • DI: High-Low state of a digital input.
  • DI flip-flop: Status change of a digital input (is stored in the module with the so-called flip-flop flag and deleted again after readout).
  • DO readback: ON-OFF status of a digital output (is read out using a DO readback command).
  • A/D: Current or voltage level at the analog inputs

 

Configuration actions
Up to 16 different actions can be created in the configuration menu. An action defines what should happen within an event after a condition is met.

The following action modes are available, depending on the module type:

  • Set DO output:    Switches a digital output on or off
  • Set D/A output:    Outputs a current or voltage value at an analog output
  • Send CAN packet:      A special CAN TX event is triggered (up to eight CAN TX events can be configured separately).

 

Digital Out
Hier können Sie die digitalen Ausgänge Ihres Modules ein- und ausschalten.
 
Folgende Funktionen können in dieser Form getestet werden.

  • Kanalweise Ein- und Ausschalten der digitalen Ausgänge
  • Readback der Kanäle
  • Setzen eines Digitalausgangs für eine bestimmte Zeit (Modulabhängig)
  • Gibt an welchen Status die Kanäle nach Ablauf der Zeit einnehmen sollen (Modulabhängig)
  • Testen der Ausgänge

Digital Out
All digital outputs of your product can be checked by clicking on the buttons.

The following switching options are possible:

  • Switching on and off channel by channel
  • Channel-by-channel switching on or off for a specific time (product-dependent)
  • Reading back the switching status (readback)

Digital In
In this view, the logical states of all optocoupler inputs can be read out.

The following information is displayed:

  • Logical status of the inputs (ON/OFF)
  • Number of detected pulses (counter function)
  • Change of state detected (flip-flop)

TTL I/O
In this menu, the TTL channels of the module can be configured as inputs or outputs. The individual TTL outputs can be switched on or off by pressing the buttons. In addition, the status of all TTL inputs can be read out.

The tool offers the following functions:

  • Configuration of the channels as input or output (in blocks of 8)
  • Switching on and off channel by channel
  • Reading back the switching status (output readback)
  • Displaying the logical status of the inputs (input readback)

 

Analog Out
Here you can test the analog outputs of the module and manually enter any voltage or current value.

Analog In
In this menu, voltage or current values of all A/D channels can be displayed.
It is also possible to activate our A/D software filter with different filter levels.

CAN Runtime Parameter

Here you can change the CAN settings of the interface, the RX and TX packets in runtime.

The following settings can be made:

  • Baud rate
  • Extended ID
  • Active on/off
  • CAN ID
  • Mode

CNT48

Here you can read out the counter readings of a counter module, select filter options and set various counting modes.

The following counting modes are supported:

  • Read on rising edge
  • Read on rising edge x2
  • Read on rising edge x4
  • Period duration
  • Frequency measurement
  • PWM measurement

Pulse generator
The pulse generator can be used to generate square-wave signals. High and low time as well as the number of pulses can be set here.

PWM Out
In this menu you have the option of testing various PWM frequencies. In addition, the duty cycle can be entered manually for each individual channel.

Temp
The temperature of all connected temperature sensors is displayed here directly in °C.

Graphical display
This menu allows a graphical representation of all analog input signals, such as A/D, temperature or FIFO-IN.

Watchdog
This tool can be used to check the configured watchdog parameters for correct function.

I/O – Timeout

You can use the timeout function in the I/O area to simulate a timeout case for your module.

The following is a description of the timeout window

  1. Read / Write symbol:   Flashes to indicate an active connection to the module
  2. Automatic access: Removing the tick triggers a timeout after the timeout time has expired
  3. Manual access: Manual retrieval of data from the module
  4. Timeout status: Shows whether the timeout is active and whether a timeout event has occurred
  5. Timeout mode: Selection between 3 timeout modes, Normal, Reactivate and Secure
  6. Timeout duration: The time after which the timeout should be triggered is set here
  7. Activate / deactivate: Activates or deactivates the timeout function

 

Access times tests
You can test the access times for the module here. The following access time tests can be performed:

  • Register – Read/Write/Write + Readback
  • Digital I/O – Read/Write/Write + Readback
  • Analog I/O – Read/Write/Write + Readback

Access times tests

This test can be used to determine the access times to the module. The test values are read and written in 8, 16, 32, or 64-bit commands.

Access times Register
The following example checks the register accesses to an Ethernet module. The average access time here is 0.5 ms.

Access times Analog I/O
In the following example, the access times to an Ethernet module with analog I/Os are checked. The average access time here is 0.6 ms.

Access times Digital I/O
In the following example, the access times to an Ethernet module with digital I/Os are checked. The average access time here is 0.6 ms.


Cable feedback tests
For this test, the digital or analog outputs of the module are connected to the corresponding digital or analog inputs of the module via cable. The feedback test now checks whether the output and input values match.

Cable return test

The cable return test can be used to check the function of all digital and analog inputs and outputs (I/Os) of a module. To do this, inputs and outputs are wired together externally on a 1:1 basis. The test software analyzes whether the output signals arrive correctly at the inputs, thereby identifying wiring errors or hardware defects.

Analog test
In analog test mode, the D/A converter outputs defined test voltages, which are then read in by the A/D converter and compared with the target values. The software counts the number of test runs and automatically documents any deviations.

Digital test
In the digital test, the switching states of the relay or MOSFET outputs are fed back externally to the optocoupler inputs. Here, too, the software counts and compares the number of cycles and automatically detects transmission errors or deviations.

Cable return test

The cable return test can be used to check the function of all digital and analog inputs and outputs (I/Os) of a module. To do this, inputs and outputs are wired together externally on a 1:1 basis. The test software analyzes whether the output signals arrive correctly at the inputs, thereby identifying wiring errors or hardware defects.

Analog test
In analog test mode, the D/A converter outputs defined test voltages, which are then read in by the A/D converter and compared with the target values. The software counts the number of test runs and automatically documents any deviations.

Digital test
In the digital test, the switching states of the relay or MOSFET outputs are fed back externally to the optocoupler inputs. Here, too, the software counts and compares the number of cycles and automatically detects transmission errors or deviations.


A/D ripple
The ripple test displays the residual ripple of the individual A/D inputs.

A/D quality measurements

The quality of an A/D measurement is influenced by various factors and can be affected by external interference. A reliable method for checking measurement quality is to measure a stable battery voltage. Our diagnostic tools can be used to determine the residual ripple and noise behavior.

A/D ripple
The A/D ripple test can be used to measure the residual ripple of the individual A/D inputs and check for interference signals such as mains hum or voltage instabilities.

A/D noise
The noise behavior of each A/D channel can be displayed graphically using A/D noise measurement. Additional filter stages with averaging can be used to smooth and improve the measurement signal.


FIFO In/Out

The software FIFO test can be used to specifically test the integrated FIFO buffering of our digital and analog NET I/O modules. Depending on whether it is an input or output module, data is read from the submodule FIFO or written to the submodule FIFO.

 

FIFO settings

The submodule number can be used to specify which module is to be tested. The start and end channels can also be used to transmit several channels simultaneously. In addition, the transmission frequency can be set and the desired FIFO mode selected – for example, for the use of test values or the actual measured values of the module.

All important information at a glance

During program execution, key information such as the size of the data packets, free and occupied bytes in the FIFO buffer, the number of data packets sent or received, and the current FIFO status are clearly displayed.


D/A output test

The D/A output test enables targeted testing of each individual D/A channel of a module. A freely selectable test voltage can be output directly. Currently, simple square wave signals with configurable high and low times are available. The signals can be monitored simultaneously with an oscilloscope. This function is also ideal for long-term tests. The test software detects DELIB errors and logs them automatically.


Mustertext

Mustertext

DO 4* value + wait

In this test, adjustable 16-bit values are written to the digital outputs of the module.
The values are sent to the module using the DapiDOSet16 command. The start channel is always channel 0.
You can set different wait times between the individual calls.
The test is intended for testing the functionality of the module.


Mustertext

Mustertext

Modbus I/O test

In the diagnostics section of the ICT-Tool, you can test the module’s digital and analog inputs and outputs directly via Modbus TCP. Register addresses as well as transfer and return values are displayed in a debug panel, allowing you to quickly diagnose problems with the D/A converter, for example. A complete overview of all register addresses and examples can be found in the Modbus manual at the following link:

To benefit from the latest functions and prevent errors, we recommend that you always keep your DEDITEC product up to date.

Flash Files
Downloading the firmware flash file package via the ICT tool

  1. Go to Flash Files in the “Firmware update” menu
  2. Click on the download button to start the download.
  3. Administration rights are required for the automatic unpacking of the flash files. If these rights are not available, the files are downloaded to the download area of your PC and must be extracted manually to the installation directory.
    \DEDITEC\DELIB\programs\flash_files

Downloading the firmware flash file package via the DEDITEC homepage

  1. Download the required firmware flash file package from our homepage: Downloads -> Software -> Firmware
  2. Extract the files to the following installation path: ..\DEDITEC\DELIB\programs\flash_files

Flash modules
In the “Firmware update” menu, select the module you want to update and then click on the “Flash modules” or “Flash submodules” button.
The firmware is now updated and the module is then restarted automatically.

 

Information on the firmware flasher
The following information is displayed in the firmware flasher:

  • Last FW: Displays the last firmware version
  • Current FW: Displays the currently installed firmware version
  • Newest FW: Displays the latest firmware version
  • Log: Displays status or error messages during the flash process

In den folgenden Kapitel, würden wir Ihnen unsere neue All-In-One-Software gerne genauer vorstellen.

General
Here you can make general configurations to the ICT tool.

The following changes can be made:

  • Language – setting between German and English possible

Updates
Here you can search for available DELIB or firmware updates.

  • Automatic update search at program start
  • Search for DELIB updates
  • Search for firmware updates

Error log
Here you can make settings for the deditec_debug.log. This is saved under the path C:\Users\?USER?\AppData\Local\DEDITEC.

The following settings can be made:

  • Enable writing to the debug.log
  • Activate log notifications
  • Activate automatic deletion of the debug.log
  • Setting after how many days the debug.log should be deleted
  • Set the maximum size of the debug.log

DELIB – DebugView – Global

Settings can be made here for the information that is to be displayed with the DebugView.

  • Activate debug output
  • Activate display of errors

DELIB – DebugView – Details
More detailed settings can be made here for the information to be displayed with the DebugView.

Configuration of CAN modules

The parameters of the CAN interface can be fully configured via the ICT-Tool. In addition to the baud rate, CAN address and other settings, automatic send and receive packets can also be set up.

Icon Can

Automatic transmission (TX mode)

The Auto-TX mode allows cyclical transmission of data packets, optionally with analog or digital input states to other CAN addresses. Alternatively, a trigger event can also be defined. In this case, a data packet is only sent once a data packet has been received on a certain CAN ID (e.g. CAN sync on ID 0x80).

 

Automatic receiving (RX mode)

With Auto-RX mode, on the other hand, received data packets are forwarded directly to analog or digital outputs. For example, relay outputs can be set via another CAN bus subscriber.

ICT-Tool

The ICT-Tool can be used to quickly and easily read out or change CAN interface settings.

Status interface
Here you can find information about the status of the CAN interface

  • Baud rate
  • Module address
  • Receiving address
  • CAN status
  • Extended ID
  • CAN modus
FormCfgCANStatus
Status TX/RX
Hier finden Sie Informationen über die TX / RX -Pakete
 

  • Anzahl gesendeter / empfangener Pakete
  • TX / RX – Pakete pro Sekunde
  • Durchschnitt gesendeter / empfangener Pakete
FormCfgCANStatistic
Config interface
Settings can be made on the CAN interface here.
 

  • Baud rate
  • Adress Bit-mode
  • Module address
  • Receiver address
FormCfgCANConfigStd
Config I/O Init
Here you can configure the CAN settings of the connected submodules.
 

  • A/D mode
  • A/D filter
  • D/A mode
  • Counter mode
  • Timeout
  • CNT48 mode
  • CNT48 submode
  • CNT48 filter
FormCfgCANConfigIO
Config TX mode
Here you can make settings to the TX package configuration.
 

  • activate / deactivate
  • Trigger mode
  • Interval
  • Use extended ID
  • Send to CAN-ID
  • TX mode
FormCfgCANTX
Config RX mode
You can make settings to the RX package configuration here.
 

  • activate / deactivate
  • Use extended ID
  • Receive from CAN-ID
  • RX mode
FormCfgCANRX
Click here to download the latest driver library.
 
You can find more details on control and some programming examples in the programming section.

M2M

Machine to Machine
M2M is the abbreviation for “machine-to-machine” and enables automatic data transmission between two or more devices. This means that analog or digital input signals from a transmitter module can be automatically transmitted to a receiver module, where they are immediately output again.

Data exchange without a control PC
The modules communicate directly at device level and therefore do not require any additional user software. The one-off configuration of the transmitter module can be carried out very easily using our ICT-Tool. All settings remain permanently stored in the module memory, even in the event of a power failure. After a restart, the module automatically switches back to M2M operation.

M2M Ethernet or M2M CAN
With our DEDITEC products, we differentiate between M2M Ethernet and M2M CAN. We also refer to the latter as CAN-TX/RX mode. Both M2M methods are supported by most of our modules with Ethernet or CAN interface.

Overview M2M

M2M-CAN

All DEDITEC products with a CAN interface are equipped with the M2M-CAN feature. The “Auto TX/RX mode” can be set in the ICT-Tool via the configuration menu. Depending on the product type, 8(4) TX and 8(4) RX modes can be defined.

"TX modes" submenu
The pictures on the right show an example configuration for a transmitter module (TX mode) and a corresponding receiver module (RX mode).

The TX mode on the transmitter module sends the logical states of inputs 1-64 to CAN ID 0x700 every 500ms.

The RX mode on the receiver module receives data packets on CAN ID 0x700 and outputs these values to outputs 1-64.

M2M CAN TX
M2M CAN RX

Control of our CAN modules

Our RAW CAN modules can be controlled in two ways:

1. Auto TX/RX mode

2. DELIB command mode

 

 

Icon Can

1. Auto TX / RX mode

This operating mode allows the module to process CAN packets automatically without the need for an additional control PC. Configuration is very simple using the ICT tool and requires no programming knowledge.

 

 

Automatic transmission (TX mode)

Auto-TX mode allows automatic, cyclical transmission of CAN packets to other bus participants. The module's digital and analog input signals can thus be forwarded directly to other devices.

As an alternative to cyclic transmission, trigger events can also be defined. This means that a CAN packet is only sent, for example, when a CAN message has been received on a specific CAN ID.

 

 

TX mode configuration

The following settings can be configured:

  • Enable/disable TX mode
  • Trigger mode
  • Interval
  • Use extended ID
  • Send to CAN ID
  • TX mode

 

 

 

FormCfgCANTX

Automatic receive (RX mode)

In Auto-RX mode, received data packets are forwarded directly to the analog or digital outputs of the module. For example, relay outputs can be set on the module via another CAN bus participant.

 

 

 

RX mode configuration
The following settings can be configured:

 

  • Enable/disable RX mode
  • Use extended ID
  • Receive from CAN ID
  • RX mode
FormCfgCANRX

2. DELIB command mode

In DELIB command mode, the module's registers are accessed via a CAN protocol developed by DEDITEC. The module expects the CAN messages on a CAN address specified in command mode. Read and write accesses with different data lengths (BYTE, WORD, LONG) are possible. Details on the protocol structure and register assignment can be found in the “Protocols & Register Assignment” manual in the download area.

 

Connection example DA4/8:

Connection example

Screwless connector system

The customer-side connection wiring of the inputs and outputs is carried out using screwless, pluggable terminal strips. The conductor connection is made using a so-called actuating tool.
A locking and ejecting mechanism facilitates the insertion and removal of the complete terminal strip.

Handling:

Steps 1-5

Step 1

See the scope of delivery for the operating tool.

Wago Betaetigungswerkzeug 615 464 Kopie
Step 2

Insert the operating tool firmly into the side opening in the direction of the conductor connection.

Konf Werkz Montage2 615 464 Kopie
Step 3

Now insert the stripped conductor into the open clamp contact.

Konf Werkz Montage3 615 464 Kopie
Step 4

Pull out the operating tool again.

Konf Werkz Montage4 615 464 Kopie
Step 5

Check that the conductor is properly connected. It should now no longer be possible to pull it out easily.

Konf Werkz Montage5 615 464 Kopie

Manual

DDT Icons Downloads PDF Transparent 250606

Manual UC series

Quickstart - Hardware description - Software description - ICT-Tool
Commissioning/Quickstart

  • Safety instructions
  • Installing the drivers
  • Connecting the power supply
  • Connecting to the PC or network
  • Connecting the I/O connectors
  • Function test

Hardware description

  • List of technical data
  • Definition of the LEDs
  • Functions of switches and buttons
  • Pin assignment of the connectors
  • Connection examples

Software description

  • Control options via the DELIB, protocol level, DELIB CLI, graphical applications
  • DELIB Driver Library, DELIB Sample Sources, DELIB for Linux
  • Web interface (only for Ethernet modules)
  • DELIB API and its functions

ICT-Tool

  • Add module on the PC
  • Configure module/interface (Ethernet, USB, CAN, serial)
  • Setting options for M2M and event control (only for supported modules)
  • Test and diagnose module
  • Install firmware updates
  • Save/load module configurations using a separate file

Software packages ICT-Tool / DELIB driver library

DDT-Icons-Downloads_ZIP_transparent_250606

ICT-Tool + DELIB for Windows (64-bit)

For Windows 11/10, Windows 7, Windows 8, Vista, XP and 2000

Software package for the 64-bit version of the ICT-Tool and the DELIB driver library.

The following operating systems are compatible:
64-bit:

  • Windows 10/11 x64
  • Windows 8 x64
  • Windows 7 x64
  • Windows Server 2012 x64
  • Windows Server 2008 x64
  • Windows Vista x64
  • Windows XP x64
  • Windows Server 2003 x64
  • Windows 2000 x64

Supplied software

ICT-Tool x64

  • Updating the DEDITEC module-firmware
  • Assigning module addresses
  • Module-specific settings
  • Configuration of CAN modules
  • Test and diagnosis of module functions
  • Configuration of the watchdog stick

Replaces the following software

  • DT-Flasher x64
  • DELIB Module Demo x64
  • CAN Configuration Utility x64
  • DELIB Module Config x64
  • DELIB Configuration Utility x64
  • Watchdog Configuration Utility x64


DELIB Command Line Interface x64

Enables the execution of DELIB commands in the command line.

DDT-Icons-Downloads_ZIP_transparent_250606

ICT-Tool + DELIB for Windows (32-bit)

For Windows 11/10, Windows 7, Windows 8, Vista, XP and 2000

Software package for the 32-bit version of the ICT-Tool and the DELIB driver library.

The following operating systems are compatible:
32-bit:

      • Windows 10/11
      • Windows 8
      • Windows 7
      • Windows Server 2012
      • Windows Server 2008
      • Windows Vista
      • Windows XP
      • Windows Server 2003
      • Windows 2000
    •  

Supplied software

ICT-Tool x32

      • Updating the DEDITEC module-firmware
      • Assigning module addresses
      • Module-specific settings
      • Configuration of CAN modules
      • Test and diagnosis of module functions
      • Configuration of the watchdog stick

 

Replaces the following software

      • DT-Flasher
      • DELIB Module Demo
      • CAN Configuration Utility
      • DELIB Module Config
      • DELIB Configuration Utility
      • Watchdog Configuration Utility

Attention:

With this version of the driver library, only 32-bit applications can be created, which can then be executed on 32- and 64-bit systems.

DDT-Icons-Downloads_ZIP_transparent_250606

DELIB driver library for Linux (32/64-bit)

For 32/64-bit Linux distributions from kernel 2.6.x. Version 2.73 from 28.10.2024

DELIB driver library for Linux distributions (32/64-bit) from kernel 2.6.x

This driver package contains the following components

  • DELIB USB driver
  • DELIB Ethernet driver
  • DELIB CLI

DELIB USB driver

Support for the following products:

  • NET series (via USB interface)
  • RO-USB series
  • BS-USB series
  • USB mini-sticks
  • USB watchdog
  • USB-OPTION-8 / USB-RELAY-8
  • USB-TTL-32 / USB-TTL-64

Note:

With the standard version of the USB driver, several USB products with different module IDs (e.g. one RO-USB and one USB-OPTOIN-8) can be addressed. No further driver installation is required.

If several USB products with the same module ID (e.g. a USB-OPTOIN-8 and a USB-RELAIS-8) are to be addressed, the Linux FTDI driver must also be installed. You can find the FTDI driver at http://www.ftdichip.com.

DELIB Ethernet driver

Support for the following products:

  • NET series (via Ethernet interface)
  • RO-ETH series
  • RO-ETH/LC series
  • BS-ETH series
  • ETH-OPTION-8 / ETH-RELAY-8
  • ETH-TTL-64

DELIB CLI

With the DELIB CLI (Command Line Interface) for Linux, all commands for digital and analog I/Os can be set directly via the command line


Manual

DDT Icons Downloads PDF Transparent 250606

Manual for ICT-Tool and DELIB

Software Description - ICT-Tool - DELIB API Reference

Software Description

  • Control options via DELIB, protocol level, DELIB CLI, graphical applications
  • DELIB driver library, DELIB sample sources, DELIB for Linux
  • Web interface (only for Ethernet modules)
  • DELIB API and its functions

ICT-Tool

  • Add module to PC
  • Configure module/interface (Ethernet, USB, CAN, Serial)
  • Settings for M2M and Event Control (only for supported modules)
  • Test and diagnose module
  • Install firmware updates
  • Save/load module configurations using a separate file

DELIB API Reference

  • Directory structure of DELIB
  • Management functions
  • Error handling
  • Manage digital inputs and outputs
  • Manage analog inputs and outputs
  • Manage software FIFO
  • Manage output timeout
  • Register read and write commands


Download

DDT-Icons-Downloads_ZIP_transparent_250606

Hardware updates (firmware flash file package)

Firmware flash file package for the ICT tool

This package contains the latest firmware files for the following product series:

  • STARTER series
  • BS series
  • RO series
  • NET series
  • UC series
  • CAN-IO-Box
  • Development accessories

The firmware flash file package can alternatively be downloaded via the ICT tool.

USB cable A plug to C plug

USB cable for connecting our modules to the control PC.

  • Type: USB 2.0, A plug to C plug
  • Length: 1 m
Zbh Kab Usb Ac 600

5-pin plug connector

Enables the power supply to be connected to the DEDITEC module.

  • Type: Phoenix Contact® - 1876343
  • 100 % mismatch protected
  • For all conductor types from 0.2 mm² to 2.5 mm²
Zbh Steck 05 Gew 600


16-pin plug connector

Required for connecting inputs and outputs of the DEDITEC module.

  • Type: WAGO® 713-1108/037-000
  • Plug-in female multipoint connector with locking mechanism
  • 100 % mismatch protected
  • 1-wire connection for all conductor types up to 1.5 mm²
ZBH STECK 16 AUSW 600


Actuating tool for Wago connectors

Used to open and close the terminal contacts on the WAGO® connectors.

  • Type: WAGO® - 734-231
Zbh Steck Werkz 600


DIN-Rail connector

The DIN rail connector is a single BUS segment that enables connection to other modules. It is clipped into the top-hat rail and plugged onto the side of an existing DIN rail connector.

  • Type: Phoenix Contact® - 2203852
  • Connection of a NET or UC module
  • For expanding the NET or UC bus system
  • 1 Piece
Din Rail Bus 615 464

USB cable A plug to C plug

USB cable for connecting our modules to the control PC.

  • Type: USB 2.0, A plug to C plug
  • Length: 1 m
Zbh Kab Usb Ac 600

5-pin plug connector

Enables the power supply to be connected to the DEDITEC module.

  • Type: Phoenix Contact® - 1876343
  • 100 % mismatch protected
  • For all conductor types from 0.2 mm² to 2.5 mm²
Zbh Steck 05 Gew 600


16-pin plug connector

Required for connecting inputs and outputs of the DEDITEC module.

  • Type: WAGO® 713-1108/037-000
  • Plug-in female multipoint connector with locking mechanism
  • 100 % mismatch protected
  • 1-wire connection for all conductor types up to 1.5 mm²
ZBH STECK 16 AUSW 600


Actuating tool for Wago connectors

Used to open and close the terminal contacts on the WAGO® connectors.

  • Type: WAGO® - 734-231
Zbh Steck Werkz 600


DIN-Rail connector

The DIN rail connector is a single BUS segment that enables connection to other modules. It is clipped into the top-hat rail and plugged onto the side of an existing DIN rail connector.

  • Type: Phoenix Contact® - 2203852
  • Connection of a NET or UC module
  • For expanding the NET or UC bus system
  • 1 Piece
Din Rail Bus 615 464


Strain relief plate for 16 or 18-pin Wago connectors

The strain relief plate is pushed onto the center of the female connector and enables the connected cables or strands to be fixed in place.

  • Type: WAGO® - 713-127
  • Strain relief for the connection wiring
  • Suitable for 16 or 18-pole female connectors
  • Slide onto the female connector from the side
ZBH STECK PL 16
ZBH STECK PL 16 Wago


Top hat rail

Top-hat rail for mounting our control technology modules.

  • DIN rail according to DIN EN 50022
  • Type: Phoenix Contact® - 1208131
  • Dimensions in mm: 450 x 35 x 7.5 (L x W x H)
Zbhhutschiene 1m 600


24V/2A power supply unit for top-hat rail mounting

The DR-4524 from Mean Well is a 48W power supply unit for DIN rail mounting for industrial applications. It offers protection against short circuit, overload, overvoltage and overheating.

  • Input voltage range: 85 V.. 264 V AC / 120 V DC ... 370 V DC
  • Output voltage: 24 V DC
  • Output current: 2 A
  • Rated power: 48 W
Zbhnetzteil 24v 2a 600

Typical Application Areas:

  • Process optimization through automation:
    Thanks to the integrated auto TX/RX mode, modules can communicate directly with each other and exchange signals—without the need for an additional control PC.
  • Decentralized CAN network nodes:
    The CAN analog converter module is suitable as a decentralized CAN I/O unit within industrial control architectures. Via the CAN bus, states and data are reliably transmitted and distributed to other system participants, enabling the integration of remote system areas into a centralized structure.
  • Automation technology:
    The D/A outputs of the UC-CAN-DA4/8_16 enable precise control of actuators and test benches in industrial applications.
  • Industrial process control:
    Analog signals can be flexibly output to actuators and control variables using the CAN analog converter module.
  • Research and development:
    Use in laboratories and test environments for scientific experiments and test setups.

Comparison of UC-CAN-DA4/8_16 with common market products

</tr ></tr ></tr ></tr ></tr ></tr ></tr ></tr ></tr >

Interfaces & Communication

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Protocol transparency For many standard modules, the telegram structure or integration is manufacturer-specific. Open CAN protocol for seamless integration into existing CAN architectures. Facilitates integration into existing controllers, gateways, and CAN networks.
Automatic telegram processing Recurring CAN telegrams often have to be processed using external control logic. Auto TX/RX mode for automatic processing of CAN packets. Reduces the implementation effort in the controller and simplifies recurring communication tasks.
CAN standards and bit rates Supported CAN parameters are often limited or less clearly specified. Supports CAN 2.0A / 2.0B and bit rates from 10 kbit/s to 1 Mbit/s. Offers greater flexibility when integrating into different CAN systems and existing installations.
Industrial use Often used for simple control tasks Designed for industrial automation and CAN networks Suitable for demanding applications with high requirements for stability and continuous operation.
USB Standard usually only USB-A / B Thanks to USB-C, it is significantly more modern and faster than typical USB I/O boards Improves compatibility with current devices and simplifies integration.
Number of USB modules that can be used simultaneously 1–4 modules, often without proper management Up to 16 modules per system Enables larger system configurations without additional distributors or expansion devices.
Galvanic isolation of the CAN interface A galvanically isolated CAN interface is not standard on all devices. Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments. Improves interference immunity and protects communication in harsh industrial environments.

Analog outputs

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Analog voltage output Basic analog outputs, often only 0–5 V or 0–10 V Precise voltage output over 0–5 V, 0–10 V or ±10 V Enables precise control of various actuators and reduces the need for external signal converters.
Current and voltage output Some providers offer only voltage or only current Both signal types supported Increases compatibility with various industrial and process signals and simplifies integration into existing systems.
Low output ripple Stronger ripple in OEM modules Low ripple and stable output signals Improves signal quality and ensures stable output values in sensitive control and regulation applications.
Galvanic isolation Often, there is no isolation from the power supply Electrical isolation for the module’s power supply Protects connected devices from interference voltages and prevents feedback between the output stage and the power supply.

Automation & Diagnostics

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Diagnostic tools Mostly not available Extensive diagnostic capabilities integrated in the ICT tool Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.
Automated control and monitoring Additional control PC required Configurable event control enables automated process monitoring without a control PC Reduces the need for external control logic and enables automated processes directly within the module.

Hardware flexibility

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Supply voltage Usually fixed (e.g., +24 V) Flexible +12 V DC … +28 V DC Facilitates use in various power supply configurations and reduces the need for additional power supplies.
EMC stability Low-cost OEM modules often susceptible to interference Industrial‑grade EMC design Ensures low-interference operation in industrial environments with high electromagnetic interference.

Software & Integration

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Software integration Limited drivers DELIB library for C, C++, C#, Java, VB Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.
Example programs Barely available or only upon request Example programs can be downloaded for free Accelerates implementation and facilitates the transition to project-specific applications.
Firmware updates Often paid or limited Free for life Ensures long-term functionality and enables improvements without additional licensing costs.
Example code Fewer languages or restricted examples Extensive examples for C, C++, C#, Java, VB, LabView Supports various development environments and facilitates integration into existing software landscapes.
Response times Partially higher latency with standard I/O Very fast firmware Improves real-time performance and enables reliable processing of time-critical signals.
System integration Proprietary systems complicate integration Easy integration into PLCs, PCs, and test benches Facilitates integration into existing automation and test systems without extensive modifications.
Test system integration Competitors often more expensive or less flexible Ideal for automotive and test bench applications Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.

Mechanical & physical properties

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Mounting Depending on the supplier, different or less standard designs may be used. Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I/O systems. Enables quick and standards-compliant integration into existing control cabinets.

Reliability

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Long-term availability Typically 3–5 years 10‑year guaranteed availability Simplifies long-term plant planning and reduces risks associated with early product discontinuations.
Firmware updates Often paid or limited Free for life Ensures continuous functional improvement without additional operating costs.
ICT tool Often multiple tools, fewer functions One tool for commissioning, diagnostics, loopback testing, long‑term simulation Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.
Production location Many manufacturers produce in Asia Made in Germany Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.
MTBF Low-cost OEM modules with shorter lifespan High MTBF values Reduces the probability of failure and increases availability in continuous-operation applications.
Failure rate Higher failure rates with low‑cost I/O Very low field failure rates Minimizes unplanned downtime and reduces maintenance and service costs.
Spare parts availability Often early discontinuation Long‑term spare parts availability Facilitates maintenance and modernization of existing systems over many years.

Service and support

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Support quality Call centers or external service providers Direct developer support Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.
Response time Sometimes several days Very fast response, often same day Reduces downtime and speeds up the restoration of system operations when technical issues arise.
Customization Rare or very expensive Custom hardware/firmware possible Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.
Documentation Often minimal or incomplete Comprehensive and practical documentation Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.
Consulting Often only sales support Technicians instead of general sales staff Ensures application-oriented support directly tailored to technical requirements.

Economy

Feature Market Comparison Advantages of the DEDITEC UC-CAN-DA4/8_16</th > Practical Benefits of the modules
Price-performance ratio Major brands significantly more expensive Very good price‑performance ratio Reduces total cost per channel and enables cost-effective system expansions.
License costs Modbus/features often require additional payment No additional costs for protocols Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.
Series prices Large manufacturers often inflexible Attractive volume pricing Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.
My cart
Your cart is empty.

Looks like you haven't made a choice yet.