User Account 1 1
Cart 0 € 0,00

RO series – low-profile, modularly configurable I/O modules for measurement and control tasks

The DEDITEC RO series comprises particularly low-profile I/O modules for industrial measurement, control, and automation tasks. A communication interface forms the basis of the system, while digital, analog, and specialized I/O submodules can be combined via a plug-in system to create a project-specific configuration. Depending on the interface, communication is provided via USB, Ethernet, CAN, or RS-232/RS-485.

The RO series is particularly suitable when different signal types need to be combined within a limited installation depth. In addition to digital inputs, relay, MOSFET, and PWM outputs, as well as analog I/Os, submodules are available for counters, incremental encoders, and PT100 temperature measurement.

The RO series at a glance

Feature Benefit
Particularly low-profile module design For applications with limited installation depth.
Modular plug-in system Configure the interface and suitable I/O submodules individually.
Digital and analog I/Os Combine different signal types within a single configuration.
Specialized functions Counters, incremental encoders, and PT100 temperature measurement.
USB, Ethernet, CAN, or serial Select the communication interface to match the control and software environment.
DIN rail mounting Integration into control cabinets and technical installations.
DELIB/API and open protocols Integration with custom software and industrial communication systems.
ICT-Tool Configuration, I/O testing, diagnostics, and firmware updates.

Which applications is the RO series suitable for?

The RO series is suitable for applications where digital, analog, and specialized I/O functions need to be provided in a space-saving design and integrated into software systems.

Machine and plant automation

Acquisition of machine states and sensor signals, switching of actuators, and output of analog control values.

Test benches and automated test systems

Combination of different measurement, test, and switching signals with custom test software via DELIB/API or suitable protocols.

Compact control cabinets and special-purpose machinery

Custom I/O configuration for applications with limited installation depth.

Counter and encoder evaluation

Acquisition of pulses and evaluation of incremental encoders using specialized submodules.

Temperature measurement

PT100 temperature acquisition combined with digital or analog I/O functions.

When is the RO series the right choice?

The RO series is the right choice when installation depth is limited and multiple different I/O functions need to be combined in a project-specific, low-profile module configuration. The key factors are the available installation space, the signal types, the selected interface, and the electrical design.

The RO series is particularly suitable when:

  • Very low installation depth is a key selection criterion.
  • Digital, analog, and specialized I/O functions need to be combined.
  • USB, Ethernet, CAN, or a serial communication interface is required.
  • Specialized modules for counters, incremental encoders, or PT100 temperature measurement are required.
  • The I/Os need to be integrated into custom PC or automation software.

When is the RO series less suitable?

For small, predefined stand-alone tasks, a module from the UC series may be sufficient. If a centrally structured architecture designed for later expansion with larger I/O systems is planned, the NET series should be considered. For applications requiring many I/Os in a closed aluminum enclosure, the BS series may be a suitable alternative.

Modular design of the RO series – individually combine the interface and I/O submodules

The RO series consists of a communication interface and I/O submodules connected via a plug-in system. The interface provides the connection to the higher-level application. The submodules provide the required digital, analog, and specialized measurement and control functions.

A maximum of ten I/O submodules can be connected per RO interface. The available submodules can be combined independently of the selected communication interface. The number of inputs and outputs depends on the type and number of submodules used.

Thanks to the particularly low-profile aluminum-plastic enclosure and DIN rail mounting, the configuration can be integrated in a space-saving manner. The overall length varies depending on the type and number of submodules used.

Subsequent expansion of the RO series

Existing RO configurations can be expanded by adding additional I/O submodules. The submodules are also available individually. If the number of submodules is increased, a correspondingly larger enclosure must also be ordered. From eight submodules onward, an additional terminating resistor is required. A maximum of ten submodules can be connected in total.

When assembling the system, the specified submodule order must be observed: Interface → digital outputs (DO) → digital inputs (DI) → counters/incremental encoders (CNT/IGR) → analog inputs (A/D) → analog outputs (D/A).

USB, Ethernet, CAN, or RS-232/RS-485 – which RO interface is right?

The appropriate communication interface depends on the existing system architecture. Depending on the interface variant, the RO series provides USB, Ethernet, CAN, or serial connectivity.
Interface Communication Particularly suitable when …
RO-USB USB the module is to be connected directly to a local control PC.
RO-ETH_LC Ethernet / TCP/IP; Modbus TCP I/O data needs to be accessible via a network.
RO-CAN RAW CAN / SAE J1939 a CAN-based control or test application is used.
RO-SER RS-232 and RS-485; depending on revision an existing serial communication interface is to be used.

RO-USB – direct connection to the control PC

RO-USB connects the RO configuration to a PC or USB hub via USB. This is suitable, for example, for local test benches, laboratory setups, and PC-based control software.

RO-ETH_LC – Ethernet and Modbus TCP

The RO-ETH_LC interface enables integration of the RO series into Ethernet networks. Supported protocols include HTTP, UDP, TCP, DHCP, and Modbus TCP. Control is available via the DEDITEC DELIB driver library, a command-line interface, and open communication protocols. The interface also provides a web interface and an app for smartphones and tablets. Encrypted Ethernet communication is also supported.

RO-CAN – RAW CAN and SAE J1939

RO-CAN supports CAN communication with 11-bit or 29-bit identifiers as well as J1939 addressing. Configurable automatic transmit and receive functions simplify the processing of CAN messages. CAN is not equivalent to CANopen.

RO-SER – RS-232 and RS-485

The RO-SER interface supports serial communication via RS-232 and RS-485. Both interfaces are supported by hardware revisions 1.0 and 2.0. Currently, only revision 2.0 is available. With this revision, part of the configuration is performed using DIP switches, while additional settings are configured via the DEDITEC ICT-Tool.

Which RO interface should I choose?

USB for direct PC connections, Ethernet for TCP/IP and Modbus TCP, CAN for RAW CAN or SAE J1939, and RS-232/RS-485 for corresponding serial communication systems. The supported additional functions depend on the respective interface and hardware revision.

Digital, analog, and specialized I/O modules of the RO series

The RO series provides I/O submodules for acquiring and outputting digital and analog signals as well as for specialized measurement and control tasks.
Category Module types Function
Digital inputs RO-OPT16 Optocoupler-isolated inputs for state detection.
Relay outputs RO-REL16 / RO-REL8_UM Relay-based switching of electrical loads.
MOSFET / PWM RO-MOS16 / RO-PWM Electronic switching and pulse-width-modulated control.
Combined digital I/Os RO-OPT8-REL8 Digital input signals and relay outputs.
Analog inputs RO-AD16_ISO / RO-AD16-DA4 Acquire voltage and optional current signals.
Analog outputs RO-DA2_ISO / RO-DA4/8 / RO-AD16-DA4 Output analog setpoint and control signals.
Counters RO-CNT8 Count pulses and process counter values.
Incremental encoders RO-CNT/IGR Evaluate encoder and position signals.
Temperature RO-PT100-4 Four PT100 measurement channels.

Digital inputs and switching outputs

Optocoupler-isolated inputs acquire binary states. Depending on the submodule, relay, MOSFET, and PWM outputs are available for switching tasks. The output technology should be selected according to the load and the required control function.

Analog inputs and outputs

Depending on the design, analog RO submodules process voltage and current signals. When selecting a module, the supported signal ranges, any required galvanic isolation, and the electrical connection requirements must be taken into account.

Counters and incremental encoders

The RO-CNT8 module is used for pulse acquisition, while the RO-CNT/IGR module is used to evaluate incremental encoder signals. These functions are suitable, for example, for testing and positioning tasks.

PT100 temperature measurement

RO-PT100 modules acquire temperature values using four PT100 resistance sensors. Temperature measurement can be combined with additional I/O functions within a suitable configuration.

Which I/O modules are available for the DEDITEC RO series?

The RO series offers digital inputs, relay, MOSFET, and PWM outputs, analog inputs and outputs, as well as specialized modules for counters, incremental encoders, and PT100 temperature measurement. The specific selection depends on the signal type, channel count, and electrical requirements. The available I/O submodules can be combined with all RO interfaces.

Even if a specific combination of interface and I/O submodules is not offered as a preconfigured product variant in the web shop, the required submodules can be ordered individually and assembled into a suitable RO configuration.

How many I/O channels does the RO series support?

The maximum number of channels in an RO configuration depends on the I/O submodules used. Up to ten submodules can be connected per interface. For example, configurations using digital input or output modules can provide up to 160 channels. Other module types and combined I/O configurations provide different channel counts depending on their respective features.

I/O function Maximum number of channels
Digital inputs 160
Digital outputs 160
Analog inputs 160
Analog outputs 80
PT100 40
Incremental encoders 20
Combined digital inputs and outputs 80 inputs / 80 outputs
ICT-Tool Configuration, I/O testing, diagnostics, and firmware updates.

How to configure your RO system

To configure an RO system, first define the required communication interface and signal requirements. Then determine the electrical requirements and mechanical installation conditions.
R

1. Select the communication interface

Select USB, Ethernet, CAN, or RS-232/RS-485 to match the existing application.
R

2. Determine the required I/O functions

Identify the required digital inputs, relays, MOSFET/PWM outputs, analog inputs or outputs, and any specialized modules.
R

3. Check the channel count and electrical requirements

Consider the number of input and output channels, measurement ranges, switching loads, galvanic isolation, and power supply requirements.
R

4. Plan submodules and installation space

Combine suitable submodules and take into account the variable overall length of the configuration on the DIN rail. A maximum of ten I/O submodules can be connected per RO interface. When assembling the system, the specified order of the submodules as well as the mechanical requirements must be observed.
Technical note:
Interface → DO → DI → CNT/IGR → A/D → D/A

R

5. Define the software and protocol integration

Consider DELIB/API, open DEDITEC protocols, and – for Ethernet – Modbus TCP.
Key question Criterion
How does the system communicate? USB, Ethernet, CAN, or serial
Which signals are processed? Digital, analog, counters, encoders, stepper, PT100
How many channels are required? Input/output channels per submodule
Which electrical requirements apply? Voltage, current, switching load, galvanic isolation
How much installation space is available? Installation depth, overall length, and DIN rail
Which control method is intended? DELIB/API, open protocols, Modbus TCP

Select RO modules by function

Select the RO interfaces and I/O submodules according to the required function. The final configuration must match the communication interface, signal type, channel count, and electrical requirements.

Relay outputs

MOSFET

Digital inputs/outputs

Analog inputs

Analog outputs

CNT / IGR

Control the RO series and integrate it into custom software

The RO series can be integrated into custom measurement, control, and automation software via DELIB/API. Open DEDITEC protocols are available for Ethernet, CAN, and serial products; Ethernet variants also support Modbus TCP. The ICT-Tool is used for configuration, testing, and diagnostics, among other functions.
Control method / Tool Application Practical benefit
DELIB / API Custom PC applications Unified access to I/O functions.
Open DEDITEC protocols Direct integration Communication without DELIB for suitable interfaces.
Modbus TCP Ethernet automation Register- and bit-based I/O access.
RAW CAN / J1939 CAN systems CAN-based I/O communication.
RS-232 / RS-485 Serial systems Integration into existing serial environments.
DELIB CLI Scripts / Tests Control via the command line.
ICT-Tool Commissioning / Diagnostics Configuration, I/O testing, and firmware updates.
Web interface Suitable Ethernet interfaces Configuration and supported I/O functions via a web browser.

Custom software with DELIB and API

The DELIB driver library enables I/O access from custom applications. Supported programming languages and environments include C, C++, C#, Delphi, Visual Basic, VB.NET, VBA, Java, Python, and LabVIEW. Corresponding driver versions are available for Windows and Linux. All DELIB commands can be executed via Python.

RAW CAN and SAE J1939

RO-CAN supports CAN communication and the configuration of automatic TX/RX functions; SAE J1939 uses the corresponding 29-bit CAN addressing. CANopen functionality is not supported.

Web interface and app for RO-ETH_LC

The RO-ETH_LC interface provides a web interface for configuring and operating various I/O functions. It can be used to change network settings, set digital outputs, read digital inputs and input counters, write analog output values, and read analog input values. Channel names can also be edited. In addition, an app is available for operation via smartphone and tablet.

Open DEDITEC protocols

For Ethernet, CAN, and serial products, DEDITEC provides open communication protocols with documented register assignments. These enable project-specific control independently of DELIB.

Serial communication

RO-SER provides integration with corresponding RS-232 or RS-485 systems; the specific functionality depends on the hardware revision.

How can the RO series be integrated into custom software?

Custom applications can access RO modules via DELIB/API. Depending on the interface, open communication protocols are also available for Ethernet, CAN, or serial communication. Modbus TCP is additionally available for Ethernet. The ICT-Tool is used for commissioning and diagnostics.

Modbus TCP via Ethernet

I/O data can be read from and written to suitable Ethernet RO modules via Modbus TCP using registers and bits.

DELIB CLI and ICT-Tool

DELIB CLI enables command-line applications on Windows and Linux. The ICT-Tool can be used to add, configure, test, and diagnose modules, as well as update their firmware.

More than basic I/O – additional functions of the RO series

In addition to standard I/O tasks, the RO series offers additional functions for signal evaluation, output control, and diagnostics. Individual functions depend on the module configuration.
Function Benefit
Digital input filters Suppress short unwanted pulses; filter time from 0 to 255 ms.
16-bit input counters Acquire digital events at suitable inputs.
State change detection Detect signal changes between two read operations.
Timeout protection Define output behavior in the event of a communication interruption.
M2M / CAN Auto TX/RX Direct data transmission with appropriately equipped interfaces.
ICT-Tool diagnostics Perform I/O, access time, Modbus, and signal tests.

Digital input filters and state change detection

Suitable optocoupler-isolated inputs can use configurable filters to suppress interference in the input signals. State changes are detected internally and can be taken into account during the next software query.

Input counters and pulse acquisition

Additional digital counter functions are also available. For specialized counting tasks, RO-CNT8 and other corresponding modules can be used.

Timeout protection for digital outputs

For appropriately equipped output modules, a defined behavior can be configured in the event of a communication failure, such as switching on, switching off, or retaining the current state.

M2M communication and CAN Auto TX/RX

CAN-based modules can automatically transmit or receive data according to configured rules. The RO-ETH_LC interface supports the M2M receive function and can receive corresponding data from compatible DEDITEC modules. An M2M transmit function is not available with RO-ETH_LC.

Diagnostics and testing

The ICT-Tool provides functions for testing digital and analog I/Os, displaying measurement data, and diagnosing communication or signal problems. The available tests depend on the functions supported by the module.

RO series in practice

DDT-Icon_Prüfstands-und-Testsysteme

Machine and plant automation

Acquire digital switching states, control actuators via relays or MOSFETs, and provide analog setpoints. The low-profile design is beneficial where installation space is limited.
DDT-Icon_Maschinen-und-Anlagenautomation

Test benches and test systems

Combine digital and analog signals in a custom-configured RO system and integrate them into test software via DELIB.
DDT-Icon_Gebaeude-und-Facility-Automation

Space-saving control cabinet installation

Mount the interface and required submodules on the DIN rail when the available installation depth in the control cabinet is limited.
DDT-Icon_Entwicklungspruefstaende-und-Sondermaschinen

Pulse counting and position detection

Acquire counter and encoder signals for testing and motion applications using RO-CNT8 and RO-CNT/IGR.
DDT-Icon_Praxisbeispiel-Steuergeraetepruefung

PT100 temperature measurement

Acquire four or eight PT100 signals and process them together with additional I/O data within a single application.

UC, NET, RO, or BS – which DEDITEC I/O series is right for your application?

The DEDITEC I/O series differ primarily in terms of design, I/O architecture, channel count, and expansion requirements. The RO series is suitable for particularly low-profile, individually configurable I/O systems. The UC series offers compact stand-alone modules, the NET series provides an expandable system architecture, and the BS series provides a large number of I/Os in a closed aluminum enclosure.
Requirement More suitable series
Particularly low installation depth RO series
Custom I/O combination in a low-profile design RO series
Targeted combination of counters, encoders, or PT100 RO series
Compact stand-alone I/O module for defined tasks UC series
Modular I/O architecture with later expansion NET series
Larger and more complex I/O systems NET series
Large number of I/Os in a closed aluminum enclosure BS series

RO series – low-profile and combinable I/O functions

Choose the RO series when low installation depth or a combination of specific I/O functions in a low-profile plug-in system configuration is important.

UC series – compact stand-alone I/O modules

Choose the UC series when the required I/O configuration is largely fixed and a compact stand-alone module is sufficient.

NET series – modularly expandable remote I/O system

Choose the NET series when higher channel counts, a centrally structured architecture, or future expansion are required.

BS series – many I/Os in an aluminum enclosure

Choose the BS series when a larger number of inputs and outputs is required in a closed aluminum enclosure.

RO or NET – what is the main difference?

The RO series focuses on particularly low-profile, project-specific combinations of interfaces and I/O submodules. The NET series uses a central NET CPU with NET-DEV modules and is designed for a scalable remote I/O architecture.

RO or UC – what is the difference?

The UC series consists of stand-alone modules with largely predefined I/O configurations, while the RO series is based on an individual combination of a communication interface and I/O submodules.

Development, long-term availability, and technical support

For industrial I/O modules, long-term availability, documentation, and support for integration and service are just as important as the technical features. DEDITEC relies on a modular development approach that makes it easier to modify individual assemblies.
Area Benefit
Modular product development Targeted modification of individual assemblies when components change.
Long-term product availability Supports long-term planning and future reordering.
Technical support Support for hardware, software, and commissioning issues.
Documentation and sample code DELIB/API, open protocols, ICT-Tool, and programming examples.
Development and manufacturing in Germany Development and production of the RO series by DEDITEC in Germany.
Custom adaptations Adaptation of software and firmware functions to specific project requirements.
DDT 20 002 USP Leiste 10 Jahre Teil 02

Modular development and long-term availability

Thanks to the modular architecture, individual assemblies can be revised when component availability changes without having to completely redesign the entire product.

DDT 20 002 USP Leiste Teil 04

Documentation and sample code

Hardware descriptions, API references, examples, and open protocols support integration into custom software solutions. The ICT-Tool simplifies setup and diagnostics.

Slider-Logo_Made in Germany

Development and manufacturing in Germany

The DEDITEC RO series is developed and manufactured in Germany. This enables DEDITEC to combine hardware and software development with its own manufacturing and technical support.

Slider-Logo_DDT-Guetesiegel

Custom software and firmware adaptations

In addition to the standard functions, DEDITEC also offers custom software and firmware adaptations for the RO series. This makes it possible to accommodate specific requirements of industrial measurement, testing, and automation applications.

Slider-Logo_DDT-Guetesiegel

Technical support for selection and integration

DEDITEC provides support for both hardware and software. Users receive assistance with commissioning, interfaces, and communication.

DDT 20 002 USP Leiste 10 Jahre Teil 02

10 years of long-term availability

DEDITEC offers ten years of long-term availability for the RO series. This supports long-term planning for measurement, control, and automation projects where replacement units or future reordering may be required over an extended period.

The modular product development approach supports this long-term strategy, as individual assemblies can be adapted in a targeted manner when component availability changes.

Accessories and additional components for the RO series

Suitable power supply and connection components are required to operate an RO configuration. Which additional components need to be ordered depends on the interface, the submodules used, and the scope of delivery.
DDT-Icon_Prüfstands-und-Testsysteme

Power supply

The RO interfaces are operated using an external DC power supply in the range of 7 to 24 V DC. When selecting the power supply, the requirements of the entire configuration must be taken into account.
DDT-Icon_Maschinen-und-Anlagenautomation

Connectors and connection accessories

For signal wiring, the RO series uses pluggable terminal blocks with different numbers of poles depending on the module. Connectors and tools already included in the respective scope of delivery do not need to be ordered separately.
DDT-Icon_Maschinen-und-Anlagenautomation

Accessories for subsequent expansion

Existing RO configurations can be expanded by adding additional I/O submodules. If the number of submodules increases, a correspondingly larger enclosure is required. For configurations with eight or more submodules, an additional terminating resistor is also required.
DDT-Icon_Gebaeude-und-Facility-Automation

Optional galvanic isolation

Suitable interface variants provide options for galvanic isolation.

Frequently asked questions about the DEDITEC RO series

What is the DEDITEC RO series?

:
;
The RO series comprises particularly low-profile, modularly configurable I/O modules for measurement, control, and automation tasks. An interface and suitable I/O submodules are combined to create a project-specific configuration.

What are the advantages of the low-profile design?

:
;
The low-profile aluminum-plastic design enables DIN rail mounting even where the available installation depth is limited. The overall length depends on the type and number of submodules used.

Can different I/O modules be combined?

:
;
Yes. The plug-in system allows digital, analog, and specialized I/O submodules to be combined with the available RO interfaces. A maximum of ten submodules can be used per RO configuration. The specified submodule order and mechanical requirements must be observed.

Which interfaces does the RO series support?

:
;
Depending on the interface variant, USB, Ethernet, CAN, and serial RS-232/RS-485 connections are available. Ethernet modules support the Modbus TCP protocol, while CAN modules enable communication via RAW CAN and SAE J1939.

Does the RO series support Modbus TCP?

:
;
Yes. The Ethernet interfaces support Modbus TCP. This protocol can be used to read and write I/O data using registers and bits.

Which specialized I/O functions are available?

:
;
The RO series supports, among other functions, counters, incremental encoder evaluation, and temperature measurement using PT100 sensors.

Can I integrate the RO series into custom software?

:
;
Yes. DELIB/API provides functions for integration into custom applications. For suitable interfaces, open DEDITEC protocols are also available, as well as Modbus TCP for Ethernet.

Which additional functions does the RO series provide?

:
;
Depending on the module, digital filters, input counters, state change detection, and configurable timeout protection are available. The ICT-Tool supports configuration and diagnostics.

What is the difference between the RO and NET series?

:
;
The RO series focuses on particularly low-profile, project-specific I/O configurations. The NET series uses a central CPU and expandable NET-DEV modules for a scalable I/O architecture.

Which applications is the RO series suitable for?

:
;
Typical applications include machine automation, test benches, compact control cabinets, and applications using counters, encoders, or PT100 sensors.

Can the RO series be expanded later?

:
;
Yes. Existing RO configurations can be expanded by adding additional I/O submodules. If the number of submodules is increased, a correspondingly larger enclosure is required. From eight submodules onward, an additional terminating resistor is required. A maximum of ten submodules can be connected in total.

Find the rightRO configurationfor your application

Configure your RO system to match your measurement, control, or automation task. Select the appropriate communication interface and the required digital, analog, or specialized I/O submodules. DEDITEC provides support with module selection, electrical configuration, and software integration.

Select RO modules

View RO interfaces and I/O submodules by function.

Support with selection

Request support with interface selection, channel count, or module combination.

Not sure which RO configuration is right for you?

For a targeted technical inquiry, it is helpful to provide information about the required interface, type and number of I/Os, voltage and current ranges, switching loads, specialized functions, available installation space, and the planned software or protocol integration.

Helpful information for your inquiry:

  • required interface, e.g. USB, Ethernet, CAN or RS232/RS485,
  • number and type of required I/Os,
  • voltage and/or current ranges,
  • loads to be switched,
  • software or programming language used,
  • required communication protocol or special functions such as Event Control or
    Modbus TCP.
My cart
Your cart is empty.

Looks like you haven't made a choice yet.