NET series – modular remote I/O system for industrial automation
The NET series is particularly suitable for applications requiring a high number of channels, different I/O types, and a scalable system architecture – for example, test benches, machine and plant automation, as well as research and development projects.
On this page
- The NET series at a glance
- Which applications is the NET series suitable for?
- When is the NET series the right choice?
- Modular design with NET CPU and I/O modules
- NET-CPU-BASE or NET-CPU-PRO-CS?
- Digital, analog, and specialized I/O modules
- How to configure your NET system
- Control the NET series and integrate it into existing systems
- More than just remote I/O
- The NET series in practice
- Which DEDITEC I/O series is right for my application?
- Access protection, timeout, and diagnostics for controlled operation
- Development, long-term availability, and technical support
- Frequently asked questions about the NET series
- Find the right NET configuration for your application
The NET series at a glance
| Modular remote I/O system | NET CPU and I/O modules can be combined to create a scalable system. |
|---|---|
| Digital and analog I/Os | Different signal types can be combined within a single system. |
| Ethernet / TCP/IP | Communication via DELIB/API or directly via the open DEDITEC TCP/IP protocol. |
| Modbus TCP | Standardized integration into automation and control systems. |
| Additional interfaces | Both NET CPU variants provide Ethernet and USB, while the NET-CPU-PRO-CS additionally offers CAN, RS-232, or RS-485 as a configurable interface. |
| High channel counts | Designed for larger measurement, testing, and automation projects. |
| Flexible expansion | The I/O structure can be adapted to changing requirements. |
| Software integration | DELIB/API, documented protocols, ICT-Tool, and sample code. |
Which applications is the NET series suitable for?
The NET series is particularly suitable for demanding measurement, control, and automation tasks that require different I/O types, higher channel counts, and flexible integration into existing software or network environments.
Test benches and test systems
For testing and test systems in which digital and analog inputs and outputs need to be monitored and controlled together.
Machine and plant automation
For connecting and controlling different sensors, actuators, and signals within a machine or system.
Production monitoring
For acquiring, monitoring, and further processing states, measured values, and process signals.
Laboratory and R&D measurement systems
For flexible experimental and measurement setups, particularly when different signal types or custom software integration are required.
Building and facility automation
For monitoring and controlling technical conditions and functions within buildings and facilities.
Special-purpose machinery engineering
For custom systems where standard I/O solutions are insufficient in terms of channel count, expandability, or software integration.
When is the NET series the right choice?
The NET series is particularly suitable when a modular and expandable I/O solution is required for more demanding measurement, control, or automation tasks. Its key strengths include higher channel counts, the combination of different I/O types, and flexible integration into existing software and network environments.
The NET series is particularly suitable when:
- a large number of inputs and outputs is required and the system should be expandable later,
- digital and analog I/O types need to be combined,
- communication via Ethernet using TCP/IP or Modbus TCP is required,
- a centralized or decentralized I/O architecture is to be implemented,
- direct software integration via DELIB/API is required,
- functions such as FIFO, Event Control, or extensive diagnostic capabilities are needed,
- test benches, measurement systems, or more complex automation projects are to be implemented.
NET series or conventional PLC?
The NET series can be an interesting alternative when many different I/O types need to be combined and direct software or API integration is preferred over conventional PLC programming. It is not positioned as a general “replacement for a PLC,” but rather as a flexible I/O platform for software-based measurement, testing, and automation tasks.
NET series or simple remote I/O module?
A simple remote I/O module may be sufficient when only a few predefined signals need to be connected. The NET series, on the other hand, is designed for scalable systems with higher channel counts, different I/O types, and additional functions such as diagnostics, FIFO, or Event Control.
When is the NET series less suitable?
- for very small projects with only a few I/Os,
- when a particularly shallow installation depth is critical,
- in very harsh outdoor environments, unless a suitable protective enclosure is provided.
Modular design with NET CPU and I/O modules
A NET CPU serves as the central communication and power supply unit of the system. The required NET-DEV I/O modules are added according to the specific measurement, control, or automation task. The CPU provides the communication interfaces, communicates with the connected NET-DEV I/Os, and supplies them with power via the internal DIN rail bus.
This means that a system with a fixed number of predefined inputs and outputs does not have to be selected from the outset. The I/O structure can be configured to suit the specific task, expanded, and adapted to changing requirements as needed.
NET-CPU-BASE or NET-CPU-PRO-CS?
| CPU | Communication | Suitable when … |
|---|---|---|
| NET-CPU-BASE | Ethernet + USB | Ethernet, or Ethernet plus USB, is required for communication. |
| NET-CPU-PRO-CS | Ethernet + USB as well as an additional interface option: CAN, RS-232, or RS-485 | additional CAN or serial communication is required. |
The NET-CPU-PRO-CS additionally features a MicroSD card slot. For additional communication, CAN, RS-232, or RS-485 can be configured as the corresponding interface option.
Digital, analog, and specialized I/O modules
The NET-DEV modules provide the actual input and output functions of the system. Depending on the application, digital, analog, and specialized I/O functions can be combined with one another.
| Category | Module | Key function |
|---|---|---|
| Analog inputs | NET-DEV-AD2-16/18_ISO | 2 galvanically isolated analog inputs with 16- or 18-bit resolution. |
| Analog inputs | NET-DEV-AD16-16/18 | 16 analog input channels. |
| Analog outputs | NET-DEV-DA4/8_16 | 4 or 8 analog outputs with 16-bit resolution. |
| Analog outputs | NET-DEV-DA2-16_ISO | 2 analog outputs with 16-bit resolution; voltage and current output. |
| Relay outputs | NET-DEV-REL16 | 16 relay outputs, available in 3 A and 5 A variants. |
| Relay outputs | NET-DEV-REL4_UM | 4 changeover relays with up to 12 A. |
| MOSFET outputs | NET-DEV-MOS16_P | 16 MOSFET outputs. |
| PWM outputs | NET-DEV-PWM16_P | 16 MOSFET PWM outputs. |
| Digital inputs | NET-DEV-OPTO-IN16 | 16 optocoupler inputs. |
| Digital inputs/outputs | NET-DEV-O8-R8_3A/5A | 8 optocoupler inputs + 8 relay outputs. |
| Temperature | NET-DEV-THERMO | 4 inputs for type K thermocouples. |
Analog inputs
Module: NET-DEV-AD2-16/18_ISO
Analog outputs
Module: NET-DEV-DA4/8_16
Relay outputs
Module: NET-DEV-REL16
MOSFET outputs
PWM outputs
Module: NET-DEV-MOS16_P and
NET-DEV-PWM16_P
Digital inputs
Module: NET-DEV-OPTO-IN16
Digital inputs/outputs
Module: NET-DEV-O8-R8_3A/5A
Temperature
Module: NET-DEV-THERMO
Analog inputs for voltage and current signals
Analog outputs for setpoints and control signals
Relay, MOSFET, and PWM outputs
Digital inputs with additional evaluation functions
Temperature measurement with type K thermocouples
Which I/O modules are available for the DEDITEC NET series?
The NET series can be expanded with modules for digital inputs, relay, MOSFET, and PWM outputs, analog inputs and outputs, as well as thermocouples. Combined modules with digital inputs and relay outputs are also available. The required NET-DEV modules are combined with a NET CPU to create a modular I/O system.
How to configure your NET system
1. Determine the communication interface
2. Determine the signal types
3. Check the electrical requirements
4. Plan the channel count and expansion capacity
Control the NET series and integrate it into existing systems
| Control / Tool | Suitable for | Practical benefit |
|---|---|---|
| DELIB driver library / API | Custom PC and software applications | Standardized integration of DEDITEC hardware into custom software. |
| Modbus TCP | PLCs, control systems, SCADA, and industrial Ethernet applications | Standardized access to I/Os via registers and bits. |
| DEDITEC protocol | Custom or hardware-level integration | Direct communication with the module. For Ethernet, the open DEDITEC TCP/IP protocol can also be implemented directly via a TCP socket. |
| DELIB CLI | Scripts, tests, and automated processes | Command-line control under Windows and Linux. |
| ICT-Tool | Commissioning, configuration, service, and troubleshooting | Configure, test, diagnose, and update the firmware of modules. |
| Web interface | Ethernet-based NET systems | Configuration and access to inputs/outputs via a browser. The web interface is accessed via HTTP; a separate HTTP API is not available. |
| CAN / J1939 or RS-232 / RS-485 | Systems with corresponding fieldbus or serial interfaces | Integration into existing communication structures. |
Ethernet communication via TCP/IP and Modbus TCP
For Ethernet applications, the NET series offers two communication methods: Communication via DELIB/API or the open DEDITEC protocol is based on TCP/IP. Alternatively, Modbus TCP provides a standardized industrial protocol for accessing I/O data via registers and bits. This allows the NET series to be integrated into custom software solutions as well as appropriately equipped control, test bench, and automation systems.
RS-232 and RS-485
Alternatively, the additional interface of the NET-CPU-PRO-CS can be configured for RS-232 or RS-485. This also allows devices and systems with conventional serial interfaces to be integrated.
CAN, RAW CAN, and J1939
The additional interface of the NET-CPU-PRO-CS can be configured for CAN. RAW CAN and J1939 are supported, as well as configurable transmit and receive functions. This allows the NET series to be integrated, for example, into CAN-based test benches, development environments, or machine applications.
USB
USB enables a direct local connection between the NET CPU and a PC or USB hub. This connection is suitable, for example, for local test benches, laboratory setups, development environments, and commissioning.
Commissioning and diagnostics with the ICT-Tool
With the ICT-Tool, NET modules can be configured, tested, and diagnosed without first having to develop a custom application. Available functions include digital and analog I/O tests, graphical displays, CAN parameters, Modbus I/O tests, loopback tests, access time tests, FIFO tests, and firmware updates.
Custom applications with DELIB and API
The DELIB driver library enables the integration of DEDITEC hardware into custom applications. Supported programming languages include C, C++, C#, Delphi, Visual Basic, VB.NET, VBA, Java, Python, and LabVIEW. For Python, the existing DELIB is integrated via a wrapper, making the DELIB functions available there as well. DEDITEC provides sample programs with source code for various programming languages.
How can the NET series be integrated into custom software?
The NET series can be integrated into custom Windows and Linux applications via the DEDITEC DELIB. For Ethernet, communication is handled via TCP/IP. Alternatively, the open DEDITEC TCP/IP protocol can be implemented directly, or Modbus TCP can be used. The ICT-Tool is available for commissioning and diagnostics, and Ethernet variants also provide a web interface. DEDITEC provides sample programs and source code for various programming languages.
Open DEDITEC protocol
For products with Ethernet, CAN, or serial interfaces, DEDITEC provides open, documented communication protocols. These can also be used without the DELIB driver library on devices equipped with the corresponding interface. For Ethernet, communication is handled via TCP/IP. The open DEDITEC TCP/IP protocol can also be implemented directly in a custom application via a TCP socket. This enables operating-system-independent and project-specific integration at the protocol level.
More than just remote I/O
Software FIFO for time-critical inputs and outputs
The NET series supports software FIFO functions for digital and analog I/O modules. Data can be buffered and assigned to specific I/O modules. This is particularly relevant when values are not only set or queried occasionally, but need to be processed continuously or according to defined timing sequences.
Event Control for local automation tasks
With Event Control, the NET series can respond independently to defined events. For example, relays or outputs can be switched when a digital input changes state or an analog measured value reaches a specified threshold. This means that an external control computer does not have to continuously trigger the corresponding response.
M2M – direct communication between modules
With the M2M function, selected input signals from one module can be automatically transferred to outputs of another module. This allows distributed I/O tasks to be implemented without having to control every individual data exchange through a higher-level application.
Testing and diagnostic capabilities
The ICT-Tool offers extensive capabilities for commissioning and troubleshooting. These include digital and analog I/O tests, graphical displays, cable loopback tests, Modbus I/O tests, access time tests, A/D noise visualization, and FIFO input/output tests.
| Software FIFO | Buffered processing of fast or time-critical input and output data. |
|---|---|
| Event Control | Automatic actions based on defined input states or measured values. |
| M2M | Direct signal exchange between modules. |
| Live / functional tests | Check inputs and outputs during commissioning. |
| Loopback tests | Check wiring and signal paths. |
| Modbus I/O test | Specifically test Modbus communication. |
| Graphical diagnostics | Assess measured values and signal behavior more easily. |
NET series in practice
Test bench and test systems
Different measurement, control, and switching signals can be combined within a NET system. Analog and digital inputs and outputs, as well as relays, can be integrated into automated test sequences. The modular architecture makes it possible to adapt test benches to changing measurement tasks or additional channels.
Machine and plant automation
Digital and analog signals as well as temperature values can be acquired and controlled within a modular I/O system. Via Ethernet, the NET series can be integrated into existing machine and automation structures using TCP/IP or Modbus TCP and expanded as I/O requirements grow.
Building and facility automation
Temperature values, switching states, pumps, valves, and other technical equipment can be monitored and controlled through a common I/O system. Thanks to its Ethernet connectivity, the NET series is also suitable for distributed automation tasks within building services systems.
Development test benches and special-purpose machines
For development and testing tasks, sensor signals can be acquired and actuators can be controlled via digital, analog, or relay-based outputs. API integration enables the I/O hardware to be incorporated into custom testing and control software.
Research and development
The NET series is suitable for modular laboratory, development, and experimental setups that require different analog and digital signals. Thanks to interchangeable and expandable I/O modules, the hardware can be adapted to changing measurement and control tasks.
Practical example: Control unit testing
For a customer in the measurement and testing sector, a NET system was used to generate and process analog signals for control unit testing. The solution combines analog inputs and outputs with the required communication interface within a modular, expandable system.
Practical example: Buffered analog output via ethernet
For a development setup in automotive engineering, analog output signals with a required output rate of up to 1 kHz and Ethernet communication were needed. The NET series was used because of its FIFO function, which allows output data to be buffered for signal processing.
Which DEDITEC I/O series is right for my application?
NET series
UC series
RO series
BS series
Which criteria are important when selecting the right I/O series?
Access protection, timeout, and diagnostics for controlled operation
The NET series offers various functions to protect communication and configuration, define specific states in the event of connection interruptions, and diagnose faults during commissioning and operation. These include TCP encryption, access protection for configuration data, controllable web access, an output timeout function, and extensive testing and diagnostic capabilities via the ICT-Tool.
Encrypted TCP communication and access rights
TCP communication between the control PC and the NET module can be encrypted. Different user and administrator rights make it possible to specifically control access to the I/Os or to the complete module configuration. Appropriate administrative access is required to change encryption settings.
Defined behavior in the event of a communication failure
The timeout function can be used to define how digital outputs should behave if the connection between the control PC and the NET module is interrupted. Depending on the configuration, outputs can be switched on or off automatically, or remain in their current state. The timeout period is configurable.
Write protection for configuration data
Write protection that can be enabled via a DIP switch can prevent changes to the stored module configuration memory via Ethernet or USB. This protects stored configuration values from unintended changes.
Internal communication without wireless transmission
Data transmission within the NET system is wired. This eliminates the additional wireless attack surface associated with Wi-Fi/WLAN communication.
Recognize status directly on the module
LEDs indicate, among other things, communication activity, Ethernet status, communication problems between the CPU and I/O modules, detected input state changes, and an output state triggered by the timeout function.
Controlled web access
Access via the web interface can be enabled or disabled and protected with a username and password. It can also be configured separately whether access to the I/Os via the web interface is permitted.
Which security and diagnostic functions does the NET series offer?
The DEDITEC NET series offers, among other things, encrypted TCP communication, user and administrator rights, hardware-based write protection for configuration data, and controlled access via the web interface. A timeout function enables defined output states in the event of communication interruptions. For commissioning and troubleshooting, various I/O, Modbus, loopback, and diagnostic tests are available via the ICT-Tool.
Commissioning and troubleshooting with the ICT-Tool
Digital and analog I/Os, Modbus communication, access times, and other system functions can be specifically tested and diagnosed. Loopback tests also help verify wiring and signal paths.
| Digital cable loopback test | Check wiring and digital signal paths. |
|---|---|
| Analog cable loopback test | Check analog output and feedback measurement. |
| Modbus I/O test | Test digital and analog I/Os directly via Modbus TCP. |
| Readback | Verify written output values. |
| Access time test | Determine minimum, maximum, and average times for I/O and register access. |
| A/D noise visualization | Graphically analyze the behavior of an analog input channel. |
| FIFO test | Test FIFO input and FIFO output. |
| Error log / DebugView | Analyze software and communication errors. |
Development, long-term availability, and technical support
Made in Germany
The NET series is developed and manufactured by DEDITEC in Germany. This keeps development, production, and technical support closely connected.
Documentation and sample code
For integrating the NET series, DEDITEC provides comprehensive technical documentation, API descriptions, and sample programs with source code for various programming languages. DEDITEC also openly documents its own communication protocol, allowing it to be integrated directly into project-specific applications.
10 years of long-term availability
DEDITEC is committed to the long-term availability of its products and components. This makes the NET series suitable for projects in which expansion, replacement, or reordering must be considered over an extended period.
The modular design supports this long-term approach: If individual components are no longer available, specific modules can be revised without having to redesign the entire product.
Binding terminology: “10 years of long-term availability” must not be equated with a product warranty.
Technical support for selection and integration
DEDITEC provides support in selecting the appropriate I/O system as well as with questions regarding control, software integration, and communication. For special requirements, customized software and firmware modifications are also possible.
Custom modifications
If the standard functions are not sufficient for an application, DEDITEC can develop project-specific software and firmware functions and adapt existing solutions to special requirements.
Frequently asked questions about the NET series
What is the DEDITEC NET series?
The NET series is a modular remote I/O system for measurement, control, and automation tasks. A NET CPU handles communication and supplies power to the connected NET-DEV I/O modules. This makes it possible to combine different digital and analog I/O functions within an expandable system.
When is the NET series the right choice?
The NET series is particularly suitable when higher channel counts, different I/O types, and an expandable system architecture are required. Typical applications include test benches and test systems, machine and plant automation, production monitoring, laboratory and R&D systems, and special-purpose machines. For small applications with only a few I/Os, the more compact UC series may be a more suitable choice.
Which I/O types can be combined in a NET system?
Available I/O types include digital inputs, relay, MOSFET, and PWM outputs, analog inputs and outputs, as well as temperature measurement using type K thermocouples. Digital inputs also support functions such as counters, input filters, and state change detection.
Which NET CPU do I need?
The NET-CPU-BASE provides Ethernet and USB. The NET-CPU-PRO-CS also provides Ethernet and USB, as well as an additional configurable interface for CAN, RS-232, or RS-485. The choice therefore mainly depends on whether CAN or serial communication is required in addition to Ethernet and USB.
Does the NET series support Modbus TCP?
Yes. In addition to TCP/IP communication via DELIB or the open DEDITEC protocol, the NET series also supports Modbus TCP over Ethernet. Modbus TCP provides standardized access to I/O data via registers and bits.
Can I integrate the NET series into my own software?
Yes. DEDITEC provides the DELIB driver library with an API for this purpose. Supported programming languages include C, C++, C#, Delphi, Visual Basic, VB.NET, VBA, Java, Python, and LabVIEW. For Python, the existing DELIB is integrated via a wrapper. DELIB is available for Windows and Linux.
Can the NET series also be commissioned without custom programming?
Yes. With the ICT-Tool, modules can be configured, tested, and diagnosed without first having to develop a custom application. Available functions include I/O tests, Modbus tests, graphical displays, loopback tests, FIFO diagnostics, and firmware updates.
What happens to the outputs if the connection to the control PC is interrupted?
A timeout function is available for digital outputs. It can be configured whether an output should be activated, deactivated, or remain in its current state in the event of a communication failure. The response can be defined in software for the respective channels.
Can a NET system be expanded later?
Yes. The NET series has a modular design. NET-DEV I/O modules are connected to the NET CPU via the internal DIN rail bus and can be configured, expanded, or replaced according to the required I/O structure.
What is the difference between the NET series and the UC series?
The NET series is designed for modular, expandable systems, higher channel counts, and more complex measurement, testing, and automation tasks. The UC series, on the other hand, is more focused on compact stand-alone applications and smaller projects.
Does the NET series support CAN and J1939?
Yes. With the NET-CPU-PRO-CS, the additional interface can be configured for CAN. RAW CAN and J1939 are supported, along with configurable transmit and receive functions. Alternatively, the interface can be configured for RS-232 or RS-485.
How many I/Os are possible with the NET series?
Up to 16 NET-DEV modules can be combined with a single NET CPU in a practical system configuration; depending on the modules used, this allows, for example, up to 256 I/O channels.
Can the NETseries also perform special functions locally?
Yes. With Event Control, the NET system can respond to defined input states or analog threshold values and then trigger configured actions. In addition, M2M functions are available for direct signal exchange between modules, as well as software FIFO functions for buffered I/O data.
Is support available for configuring a NET system?
Yes. DEDITEC provides support in selecting the appropriate I/O types and system architecture, as well as with questions regarding API and Modbus TCP integration. Custom software and firmware functions can also be implemented for special requirements.
Suitable NET configuration for your application
Configure your NET series according to the required interfaces, I/O types, and channel count. If you need assistance selecting the NET CPU, I/O modules, or integrating the system into your software, DEDITEC can help you configure a suitable system.
Select NET products
Configure the CPU and suitable I/O modules for your own system.
Support with configuration
Unsure which CPU, I/O modules, interfaces, or software integration you need?
Helpful information for a technical inquiry:
- required interface, e.g. Ethernet, USB, or CAN,
- number and type of required I/Os,
- voltage and current ranges,
- loads to be switched,
- software or programming language used,
- special requirements such as FIFO, Event Control, or Modbus TCP.
Install the installation program and check the module functions.