User Account 1 1
Cart 0 € 0,00

BS series – robust I/O modules for high channel counts

The DEDITEC BS series comprises robust I/O modules in aluminum enclosures for industrial measurement, control, and automation tasks. It is particularly suitable for applications that require a large number of digital inputs and outputs within a stand-alone module. Depending on the variant, digital inputs with optocouplers as well as relay or MOSFET outputs are available. In addition, the BS-WEU product family also provides analog inputs and outputs.

The BS series is divided into the BS-USB and BS-WEU product families. While BS-USB modules provide digital I/O configurations with a total of 32 channels, BS-WEU includes purely digital variants with 16 to 128 channels as well as analog and combined variants. For modules with analog I/O functions, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, can be combined. BS-USB uses USB as its standard interface. BS-WEU includes USB, Ethernet, and WiFi/WLAN as standard interfaces. CAN and serial RS-232 interfaces are optionally available for both product families.

With their high channel counts, robust aluminum enclosure design, and DIN rail mounting, the BS series is particularly suitable for PC-based measurement and control systems, test benches, and industrial automation applications.

The BS series at a glance

The DEDITEC BS series offers a range of I/O modules for industrial measurement, control, and automation tasks. The BS-USB and BS-WEU product families differ primarily in terms of channel counts, available I/O types, and communication interfaces.
Feature Benefit
Robust aluminum enclosure Closed enclosure design for industrial measurement, control, and automation applications.
High digital channel counts Purely digital BS-WEU variants with 16 to 128 channels. For analog I/O combinations, a maximum of 32 digital inputs or outputs, or 16 inputs and 16 outputs.
BS-USB and BS-WEU Two product families with different channel counts, I/O configurations, and communication options.
Digital inputs and outputs Optocoupler-isolated inputs for state detection as well as relay or MOSFET outputs for switching and control tasks.
Analog I/O variants BS-WEU additionally provides analog inputs and outputs as well as combined analog/digital variants.
USB, Ethernet, and WiFi/WLAN BS-USB with USB as the standard interface. BS-WEU with USB, Ethernet, and WiFi/WLAN as standard interfaces.
Optional CAN and RS-232 interfaces Additional communication options for BS-USB and BS-WEU.
DIN rail mounting Mounting on a DIN rail, for example in a control cabinet.
DELIB/API and ICT-Tool Software integration, configuration, functional testing, and diagnostics of the modules.

Which applications is the BS series suitable for?

The DEDITEC BS series is particularly suitable for industrial measurement, control, and automation tasks that require a large number of digital inputs and outputs within a stand-alone I/O module. With different channel counts, I/O configurations, and communication interfaces, the modules can be integrated into PC-based test and control systems as well as industrial installations. In addition to acquiring digital states and switching electrical loads, the BS-WEU product family also supports the processing of analog signals.

Test benches and automated test systems

For test benches and automated test systems that require numerous digital states to be acquired or switching operations to be controlled. Depending on the module, optocoupler-isolated inputs as well as relay or MOSFET outputs are available. The high channel counts make it possible to connect a large number of test signals within a single module.

Machine and plant automation

For industrial machines and systems in which numerous digital input and output signals need to be processed. The BS series can, for example, acquire switching states, control actuators, or switch electrical loads via relay or MOSFET outputs. Processing and control are performed via the connected customer application.

Production and process monitoring

For acquiring and monitoring digital states within industrial production and process workflows. Optocoupler-isolated inputs can be used, for example, to read switching states or other binary process signals and forward them to a higher-level application.

Control of numerous electrical loads

For applications in which many electrical loads or circuits need to be controlled via a common I/O module. Depending on the required output technology, variants with relay or MOSFET outputs are available. The choice of the appropriate module depends, among other factors, on the channel count, load type, and electrical requirements.

Analog measurement and control tasks

For applications that require analog voltage or current signals to be acquired or output. The BS-WEU product family provides analog input and output variants as well as modules that combine analog and digital I/O functions. This makes it possible, for example, to acquire analog measured values and output setpoint or control signals.

Laboratory, development, and research systems

For PC-based experimental, measurement, and development setups with numerous digital signals or combined analog and digital I/O requirements. The modules can be integrated into custom software applications via the DELIB driver library and used for project-specific measurement and control processes.

When is the BS series the right choice?

The DEDITEC BS series is particularly suitable when a large number of inputs and outputs is required within a stand-alone I/O module for industrial measurement, control, or automation tasks. Its main strengths are high digital channel counts, a robust aluminum enclosure, and a range of I/O configurations. Depending on the application, analog inputs and outputs as well as various communication interfaces are also available.

The BS series is particularly suitable when:

  • a large number of digital inputs or outputs is required within a single module,
  • digital states need to be acquired or numerous electrical loads need to be switched via relay or MOSFET outputs,
  • a closed aluminum enclosure for DIN rail mounting is required,
  • a predefined I/O configuration without later modular expansion is planned,
  • analog and digital signals need to be combined within a single module (BS-WEU),
  • USB connectivity is required for BS-USB, or communication via USB, Ethernet, or WiFi/WLAN is required for BS-WEU,
  • optional CAN or serial RS-232 interfaces are required,
  • the modules need to be integrated into custom PC-based measurement, testing, or control applications.

BS series or modular I/O system?

The BS series is particularly suitable for applications where the required inputs and outputs are already largely defined and a high channel count needs to be provided within a single module. The I/O configuration is determined by the selected BS variant.

In contrast, the NET series is designed for modularly expandable I/O systems. Different I/O modules can be combined via a central NET CPU, and the system configuration can be expanded as required.

If a large number of inputs and outputs is required in a predefined configuration, the BS series can be a suitable solution. If different I/O types need to be combined flexibly or additional modules may be added later, the NET series is generally the better choice.

If you need … More suitable
Many digital I/Os within a stand-alone module BS series
Closed aluminum enclosure with DIN rail mounting BS series
High channel counts with a predefined I/O configuration BS series
Modularly expandable I/O architecture NET series
Flexible combination of different I/O modules NET series
Later expansion with additional I/O modules NET series

BS-USB or BS-WEU?

Within the BS series, the choice of product family primarily depends on the required channel count, signal types, and communication interface. BS-USB is suitable for PC-based applications where a total of 32 digital channels in a predefined configuration is sufficient. BS-WEU offers purely digital variants with 16 to 128 channels as well as analog and combined analog/digital I/O modules. For analog combinations, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, is available. USB, Ethernet, and WiFi/WLAN are included as standard with BS-WEU. CAN and serial RS-232 interfaces are optionally available for both product families.

When is the BS series less suitable?

The BS series is generally not the first choice when:

  • the I/O system is intended to be expanded later with additional I/O modules featuring different functions,
  • a particularly compact design for smaller measurement and control tasks is the main priority,
  • a particularly low installation depth is required,
  • a freely configurable combination of different I/O functions and specialized functions within a modular architecture is required.

In these cases, it should be evaluated whether the NET, UC, or RO series is better suited to the respective requirements.

BS-USB or BS-WEU – which variant is right for your application?

The DEDITEC BS series comprises the BS-USB and BS-WEU product families. Both offer I/O modules in aluminum enclosures for industrial measurement, control, and automation tasks. They differ primarily in terms of available channel counts, signal types, and communication options.

While BS-USB is designed for digital I/O applications with a total of 32 channels, BS-WEU offers a wider range of digital channel counts as well as additional analog and combined I/O variants. This allows the appropriate product family to be selected according to the required signals and the intended system connection.

Feature BS-USB BS-WEU
Digital channel counts 32 channels 16, 32, 64, 96, or 128 channels for purely digital variants
Digital inputs Optocoupler-isolated Optocoupler-isolated
Digital outputs Relay or MOSFET Relay or MOSFET
I/O configuration Input-only, output-only, or combined Input-only, output-only, or combined
Analog inputs/outputs Not available Analog and combined analog/digital variants; additionally, a maximum of 32 digital inputs or outputs, or 16 inputs and 16 outputs
USB Standard interface Standard interface
Ethernet / WiFi Not available for the current BS-USB variants Standard interface
CAN / RS-232 Optional Optional
Enclosure / mounting Aluminum / DIN rail Aluminum / DIN rail
Software integration DELIB/API; ICT-Tool DELIB/API; ICT-Tool

BS-USB – digital I/O modules for PC connectivity

BS-USB modules are suitable for PC-based measurement, testing, and control tasks that require a total of 32 digital inputs and outputs. Depending on the variant, modules are available with 32 optocoupler-isolated inputs, 32 relay or MOSFET outputs, or combined configurations with 16 inputs and 16 outputs.

Communication is provided via USB as standard. For applications with corresponding communication requirements, optional CAN or serial RS-232 interfaces are available.

BS-WEU – high channel counts and additional analog I/Os

The BS-WEU product family expands the range with purely digital I/O modules featuring 16 to 128 channels. Depending on the variant, input-only, output-only, or combined configurations are available with optocoupler-isolated inputs and relay or MOSFET outputs.

BS-WEU also provides modules with analog inputs and outputs as well as combined analog/digital variants. In these configurations, a maximum of 32 digital inputs or 32 digital outputs, or 16 digital inputs and 16 digital outputs, can be combined with the analog functions. USB, Ethernet, and WiFi/WLAN are included as standard with all BS-WEU modules. CAN and serial RS-232 interfaces are optionally available.

Which BS product family should I choose?

The choice between BS-USB and BS-WEU primarily depends on the required channel count, signal types, and communication interface.

  • Choose BS-USB if 32 digital I/O channels are sufficient and a direct USB connection to a control PC is required.
  • Choose BS-WEU if different or higher digital channel counts are required, analog signals need to be processed, or Ethernet/WiFi connectivity is required as standard. For combined analog/digital variants, the limited number of digital channels must be taken into account.
  • Consider the optional interfaces if the application needs to communicate via CAN or RS-232.

Digital and analog I/Os of the BS series

The DEDITEC BS series offers different I/O variants for acquiring digital states, switching electrical loads, and processing analog signals. Depending on the product family, optocoupler-isolated inputs, relay and MOSFET outputs, as well as combined digital inputs and outputs are available. The BS-WEU product family additionally includes analog inputs and outputs as well as modules with combined analog and digital I/O functions.

The selection depends primarily on the required signal type, channel count, output technology, and the electrical requirements of the respective application.

I/O category Example variants Function
Digital inputs BS-USB-O32, BSW-O16, BSW-O64, BSW-O128 Acquire digital states via optocouplers
Relay outputs BS-USB-R32, BSW-R16, BSW-R64, BSW-R128 Switch electrical loads and circuits
MOSFET outputs BS-USB-M32, BSW-M16, BSW-M64, BSW-M128 Electronic switching and control tasks
Combined digital I/Os BS-USB-O16-R16, BS-USB-O16-M16, BSW-O32-R32, BSW-O64-M64 Acquire digital states and switch outputs within the same module
Analog inputs BSW-AD16 Acquire analog voltage and current signals
Analog inputs and outputs BSW-AD16-DA4_16 Acquire analog measured values and output setpoint or control signals
Combined analog and digital I/Os BSW-AD16-DA4_16-OR16, BSW-AD16-DA4_16-OR3A, BSW-AD16-DA4_16-OM16 16 analog inputs, four analog outputs, 16 digital inputs, and 16 relay or MOSFET outputs each. The output technology and load capacity vary depending on the variant.

Digital inputs with optocouplers

For acquiring digital states, BS-USB and BS-WEU modules with optocoupler-isolated inputs are available. Depending on the variant, different channel counts can be provided within a single module.

The digital inputs also provide additional evaluation functions. These include 16-bit counters for each channel, programmable input filters, and detection of state changes between two read operations. This makes the modules suitable, for example, for acquiring switching states, binary process signals, and digital test signals.

Relay outputs for electrical switching tasks

For relay-based switching and control tasks, the BS series offers modules with different numbers of output channels. Depending on the variant, relay versions with different electrical load capacities are available. In addition to relay-only modules, combined variants are available that integrate digital optocoupler-isolated inputs and relay outputs within a single module.

The selection of the appropriate relay module depends primarily on the required number of switching channels as well as the voltage, current, and type of loads to be connected.

MOSFET outputs for electronic switching tasks

As an alternative to relay-based outputs, the BS series offers modules with MOSFET outputs. These enable electronic switching of suitable DC loads. Depending on the module, MOSFET output-only variants or combined versions with digital optocoupler-isolated inputs are available.

Which variant is suitable depends, among other factors, on the required channel count, supply voltage, and the electrical characteristics of the load to be switched.

Analog inputs for voltage and current signals

For analog measurement tasks, the BS-WEU product family offers modules with 16 analog input channels and 16-bit resolution. The inputs support different voltage measurement ranges as well as the acquisition of current signals with the appropriate circuitry. This allows analog measured values to be integrated into PC-based measurement, testing, and control applications.

Configurable digital filter functions are also available, allowing measured values to be smoothed by averaging.

Analog outputs for setpoint and control signals

For the output of analog signals, the BS-WEU product family includes modules with analog output channels. For example, the BSW-AD16-DA4_16 combines a total of 16 analog inputs with four analog outputs, each with 16-bit resolution.

The analog outputs support different voltage signals. This makes it possible, for example, to provide analog setpoints or control signals within a measurement or control application.

Combined digital and analog inputs and outputs

For applications where different signal types need to be processed within a single module, the BS-WEU product family offers combined I/O variants.

The combined BS-WEU variants BSW-AD16-DA4_16-OR16, BSW-AD16-DA4_16-OR3A, and BSW-AD16-DA4_16-OM16 each provide 16 analog inputs (16-bit), four analog outputs (16-bit), 16 digital inputs, and 16 digital outputs. They differ in their output technology: OR16 provides 1 A relay outputs, OR3A provides 3 A relay outputs, and OM16 provides 3 A MOSFET outputs. This allows analog measured values, digital states, and electrical switching tasks to be combined within a single module. For analog BS-WEU variants, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, is available.

Which I/O type is right for your application?

  • Choose digital inputs when switching states or other binary signals need to be acquired.
  • Choose relay outputs when electrical loads need to be switched via relay contacts.
  • Choose MOSFET outputs when suitable DC loads need to be switched electronically.
  • Choose analog inputs when voltage or current signals need to be measured.
  • Choose analog outputs when analog setpoints or control signals need to be output.
  • Choose combined I/O modules when different input and output functions are required within a single module.

How to select the right BS module

Which I/O module from the DEDITEC BS series is suitable for an application depends primarily on the required signal type, the number and combination of inputs and outputs, the electrical requirements, and the desired communication interface. Software integration and installation conditions should also be taken into account.

The following selection criteria help identify a suitable BS-USB or BS-WEU variant for the respective measurement, control, or automation task.

BS-WEU-OR16 view
iot internet analog converter, DEDITEC BSW-AD16-DA4_16-OR16, Aluminiumgehäuse mit beschrifteter Frontseite und zahlreichen Signal LEDs. USB Buchse unten links. Steckbare Klemmleisten mit Auswerfmechanik bieten die Möglichkeit die Ein- und Ausgänge anzuschließen
BS-USB view
R

1. Define the required signal types

First, determine which signals need to be acquired or output. For digital applications, optocoupler-isolated inputs as well as relay and MOSFET outputs are available. If only digital signals are required, both BS-USB and BS-WEU may be suitable depending on the required channel count.

If analog voltage or current signals need to be acquired or analog control signals need to be output, suitable BS-WEU variants are available. Combinations of analog and digital I/O functions within a single module are also possible.

R

2. Determine the channel count and I/O combination

Next, determine how many inputs and outputs are required and how they should be distributed. The BS-USB product family offers digital modules with a total of 32 channels. BS-WEU includes digital variants with 16, 32, 64, 96, or 128 channels.

Depending on the variant, input-only, output-only, or combined modules are available. For example, the BS-USB-O16-R16 provides a total of 16 digital inputs and 16 relay outputs. The BSW-O48-R48, in contrast, provides 48 digital inputs and 48 relay outputs within a single module.

It is important to consider not only the total number of channels but also how they are distributed. The available combinations are defined by the respective module variants.

R

3. Check the output technology and electrical requirements

When switching electrical loads, a distinction must be made between relay and MOSFET outputs. Relay outputs are suitable for conventional switching tasks using electrical contacts. MOSFET outputs, in contrast, enable electronic switching of suitable DC loads.

When selecting a module, the required voltage, switching current, load type, and permissible load capacity of the respective outputs must be taken into account. Since the BS series offers different output variants, these electrical characteristics should always be checked for the specific module.

R

4. Select the communication interface

The appropriate interface depends on how the BS module is to be integrated into the existing measurement, control, or automation environment.

  • USB: Direct connection to a control PC or PC-based measurement and test system.
  • Ethernet: Standard interface of BS-WEU modules for integration into IP-based networks and communication via Modbus TCP.
  • WiFi/WLAN: Standard wireless network interface of BS-WEU modules for integration into IP-based networks.
  • CAN or RS-232: Optional communication variants for BS-USB and BS-WEU.

While USB, Ethernet, and WiFi/WLAN are included as standard with BS-WEU, CAN and RS-232 are optional interfaces. The available communication protocols depend on the selected interface.

R

5. Define the software and protocol integration

Consider DELIB/API, open DEDITEC protocols, and – for Ethernet – Modbus TCP.

Examples for selecting a BS module

Requirement Example of a suitable variant
16 digital inputs and 16 relay outputs BS-USB-O16-R16
32 digital inputs BS-USB-O32
8 digital inputs and 8 relay outputs BSW-O8-R8
48 digital inputs and 48 relay outputs BSW-O48-R48
128 digital inputs BSW-O128
16 analog inputs and 4 analog outputs BSW-AD16-DA4_16

The examples are intended as an initial guide. For the final product selection, the required communication interface, electrical connection values, and the specific module variant must also be taken into account.

BS modules by function

The DEDITEC BS series includes I/O modules for acquiring digital states, switching electrical loads, and processing analog signals. Depending on the application, input-only or output-only modules are available, as well as variants that combine multiple I/O functions within a single enclosure.

The BS-USB and BS-WEU product families offer different channel counts and communication options. For targeted module selection, the available variants can be grouped according to their I/O functions.

Digital inputs – optocoupler modules

For acquiring digital switching and sensor signals, the BS series offers modules with optocoupler-isolated inputs. The BS-USB product family provides a variant with 32 digital inputs for this purpose.

For purely digital BS-WEU modules, variants with 16, 32, 64, 96, or 128 digital inputs are also available. This makes it possible to implement applications with numerous digital input signals within a single module.

Digital outputs – relay and MOSFET modules

For digital switching and control tasks, BS modules with relay or MOSFET outputs are available. The BS-USB product family offers variants with 32 digital outputs. For purely digital BS-WEU modules, different channel counts from 16 to 128 outputs are available.

Relay outputs are suitable for conventional electrical switching tasks. MOSFET outputs enable electronic switching of suitable DC loads. Depending on the requirements, different output technologies and electrical load capacities can be selected.

Combined digital inputs and outputs

If an application requires both the acquisition of digital states and the switching of electrical loads, the BS series offers combined I/O modules.

For BS-USB, for example, variants with 16 optocoupler-isolated inputs and 16 relay or MOSFET outputs are available. The purely digital BS-WEU variants additionally include combined configurations with 8, 16, 32, 48, or 64 digital inputs and the same number of outputs. This makes it possible to provide up to 64 digital inputs and 64 digital outputs within a single module.

Analog inputs and outputs

For analog measurement and control tasks, the BS-WEU product family offers modules with 16 analog input channels for acquiring voltage and current signals.

In addition, variants are available that combine 16 analog inputs with four analog outputs. These also enable the output of analog setpoint and control signals. The available measurement and output ranges depend on the respective module variant and configuration.

Combined analog and digital I/O modules

For applications with different signal types, BS-WEU also offers modules that combine analog and digital I/O functions.

Available configurations include modules with 16 analog inputs, four analog outputs, 16 digital inputs, and 16 relay or MOSFET outputs. Depending on the variant, relay outputs with 1 A or 3 A load capacity or MOSFET outputs with 3 A load capacity are available. Analog BS-WEU modules support a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs. Variants combining analog I/Os with 64, 96, or 128 digital channels are not available.

Control the BS series and integrate it into existing systems

The DEDITEC BS series can be integrated into PC-based measurement, control, and automation applications via various communication interfaces. BS-USB includes USB as standard. BS-WEU modules feature USB, Ethernet, and WiFi/WLAN as integrated standard interfaces. Users can select the communication method that best suits their application. Optional CAN or serial RS-232 interfaces are also available for both product families.

For integration into custom software applications, DEDITEC provides the DELIB driver library with a uniform programming interface. Alternatively, modules with suitable interfaces can be controlled via the open DEDITEC communication protocols. Ethernet-capable variants also support Modbus TCP.

The DEDITEC ICT-Tool is available for commissioning, configuration, functional testing, and diagnostics. It can be used to configure the modules and test their inputs and outputs.

Overview of communication and integration options

Control method / Tool Application Practical benefit
DELIB/API Custom PC and software applications Unified software integration and access to I/O functions
USB BS-USB and BS-WEU; local PC-based measurement and control systems Direct connection between the control PC and BS module
Ethernet / TCP/IP BS-WEU; Ethernet interface included as standard Network-based integration and communication via TCP/IP
WiFi/WLAN BS-WEU; WiFi/WLAN interface included as standard Wireless integration into an IP network
Modbus TCP PLC, SCADA, and industrial network applications Standardized register- and bit-based access to I/O data
CAN / RAW CAN / SAE J1939 CAN-based control systems Transmission and processing of CAN messages
RS-232 Systems with serial communication Connection via optional serial interface
Open DEDITEC protocols Custom software and system integration Direct communication without DELIB via suitable interfaces
DELIB CLI Scripts and automated tests Control of supported modules via the command line
ICT-Tool Commissioning, configuration, and diagnostics Configure modules, test I/Os, and update firmware
Web interface Suitable network-capable modules Browser-based configuration and operation

Custom applications with DELIB and API

The DELIB driver library enables integration of the BS series into custom software applications. The uniform API provides access to digital inputs and outputs and, for appropriately equipped BS-WEU modules, analog inputs and outputs.

DEDITEC supports C, C++, C#, Delphi, Visual Basic, VB.NET, and VBA, among others. Integration with Java and LabVIEW is also possible. For Java, different integration methods apply depending on the interface used.

DELIB is available for Windows and Linux. In addition, DEDITEC provides sample programs with source code to simplify the development of custom measurement, testing, and control applications.

CAN – RAW CAN, SAE J1939, and automatic message processing

Optional CAN interfaces are available for both BS-USB and BS-WEU. These enable the modules to be integrated into CAN-based measurement, control, and automation systems.

RAW CAN, SAE J1939, and the DEDITEC DELIB command mode are supported. With RAW CAN, messages with 11-bit or 29-bit identifiers can be processed. For SAE J1939, addressing is configured using the corresponding message parameters.

Configurable functions for automatically transmitting and receiving CAN messages are also available. Depending on the module configuration, digital input states or analog measured values can be transmitted, for example, while received data can be used to control corresponding outputs. CAN communication is configured via the ICT-Tool.

Control via the command line with DELIB CLI

DELIB CLI can be used to control supported BS modules via the command line. This option is available for USB and Ethernet modules under Windows and Linux.

Command-line control is suitable, for example, for automated tests, scripts, and recurring control sequences. Depending on the module configuration, digital and analog inputs and outputs can be read or controlled.

USB – direct connection to the control PC

USB enables a local connection between a BS module and a control PC or USB hub. The BS-USB product family uses USB as its standard interface. All BS-WEU modules also feature an integrated USB interface. In addition, BS-WEU includes Ethernet and WiFi/WLAN as standard.

This connection is particularly suitable for PC-based test benches, laboratory setups, and measurement and control applications where the modules are to be connected directly to a computer. The available inputs and outputs can be accessed from the respective software application via the DELIB driver library.

RS-232 – serial communication

In addition to CAN, DEDITEC optionally offers a serial RS-232 interface for both BS product families. This enables the modules to be integrated into applications that use serial communication. The DELIB driver library or the corresponding open DEDITEC communication protocols can be used for integration.

Commissioning and diagnostics with the ICT-Tool

The DEDITEC ICT-Tool can be used to configure, test, and diagnose BS modules without first having to develop a custom software application. Available functions include testing digital and analog inputs and outputs, configuring communication interfaces, performing functional tests, and using diagnostic functions.

Firmware updates can also be carried out via the ICT-Tool. For modules with corresponding additional functions, further settings can be configured, for example for CAN communication or monitoring functions.

Ethernet and WiFi – I/O communication via TCP/IP and Modbus TCP

All BS-WEU modules include Ethernet and WiFi/WLAN as standard and can therefore be integrated into an IP-based network via the appropriate interface. Communication via Ethernet can be carried out using TCP/IP. For this purpose, either DELIB/API or the open DEDITEC TCP/IP protocol can be used, or alternatively Modbus TCP.

Modbus TCP enables standardized access to I/O data via registers and bits. This allows suitable BS-WEU modules to be integrated, for example, into industrial control, test bench, and automation systems with corresponding Modbus TCP support. The communication protocols that can be used depend on the interface and the functions supported by the module.

Open DEDITEC protocols for custom software solutions

For BS modules with Ethernet, CAN, or serial interfaces, DEDITEC provides open communication protocols. These enable direct control at the protocol level without necessarily requiring the DELIB driver library.

Communication via Ethernet is carried out using TCP/IP, while the respective communication protocols are available for CAN and RS-232. This allows developers to integrate the BS series into custom software and system architectures that require direct communication with the hardware.

Web interface for network-capable BS modules

Suitable network-capable BS modules also feature an integrated web interface. Network settings can be configured via a browser, while available inputs and outputs can be displayed and controlled. Access to the web interface is protected by user login.

The web interface therefore complements software-based control via DELIB, open DEDITEC protocols, or Modbus TCP.

More than basic I/O – additional functions of the BS series

In addition to acquiring and outputting digital and analog signals, the DEDITEC BS series provides additional functions for measurement, control, and automation applications. These include counters and filters for digital inputs, state change detection, configurable output behavior in the event of communication interruptions, and event-driven signal processing.

Depending on the module configuration and communication interface, additional functions are also available for direct data exchange between modules, processing analog measured values, and diagnostics. This makes it possible to implement more complex tasks within an existing control or software environment.

Digital inputs with counter functions

The digital optocoupler-isolated inputs of the BS series provide additional counter functions. A 16-bit counter is available for each input channel to detect signal changes or pulses.

The internal counter logic supports frequencies of up to 10 kHz and provides a latch function for capturing counter values. The counter values can be read via software and used for further evaluation. This makes it possible, for example, to acquire switching pulses or recurring digital signal events within a measurement or control application.

Digital input filters and state change detection

Programmable filters are available for the digital inputs. These can be used to suppress unwanted short signal pulses. The minimum valid pulse duration can be configured via software.

In addition, the BS modules can detect state changes between two read operations. Internal logic detects transitions from High to Low or from Low to High and stores this information in a register. This allows signal changes that occur between two regular input queries to be detected as well.

Event Control – trigger actions automatically

The Event Control function allows event conditions and the resulting actions to be configured within a BS module.

For example, a digital input signal can be used as a trigger to switch a digital output. With appropriately equipped BS-WEU modules, analog input values can also be used as event conditions.

The available conditions and actions depend on the respective module configuration. In addition to digital switching actions, suitable variants can also set analog output signals or trigger CAN messages.

The event conditions and actions can be configured via the ICT-Tool. This allows certain responses to be executed directly by the module without requiring every individual action to be triggered by the higher-level PC application.

Timeout protection for digital outputs

The timeout function makes it possible to define the behavior of digital outputs in the event of a communication interruption between the control PC and the BS module.

For individual output channels, it can be configured whether they are to be activated, deactivated, or remain in their current state when a timeout occurs. The time until the timeout function is triggered can also be configured.

Several timeout operating modes are available for different requirements. This allows the output behavior to be adapted to the respective measurement, testing, or control application. The timeout function supplements communication monitoring but does not replace an independent safety-related control system.

M2M communication – direct data exchange between modules

M2M (Machine-to-Machine) enables the direct exchange of signals and data between appropriately equipped DEDITEC modules. Within the BS series, two different communication methods are available for this purpose: M2M via Ethernet and M2M via CAN.

All BS-WEU modules with digital or analog inputs support M2M via Ethernet. This allows input states or measured values to be transferred directly between appropriately equipped DEDITEC modules without requiring each data transfer to be triggered by a higher-level PC application.

Alternatively, M2M communication via CAN is possible. For this purpose, automatic transmit and receive functions (TX/RX) are used. These are generally available for all modules equipped with a CAN interface. Since CAN is optionally available for both BS-USB and BS-WEU, appropriately equipped BS-USB modules can also participate in CAN-based M2M communication.

Which signals can be transmitted or processed depends on the I/O configuration and the communication interface used.

Smooth analog measured values using filter functions

For BS-WEU modules with analog inputs, additional filter functions are available for processing measurement signals. A/D filtering is based on averaging multiple measurements. This allows fluctuating measured values to be smoothed and the influence of short-term disturbances to be reduced.

The filter can be configured via software. It should be noted that stronger averaging reduces the available sampling rate. This allows the processing of analog measured values to be adapted to the requirements of the respective measurement or testing task.

Advanced diagnostic and testing functions

The DEDITEC ICT-Tool provides various functions for testing and diagnosing BS modules. In addition to directly testing digital and analog inputs and outputs, input counters can be checked, communication functions can be tested, and diagnostic values can be evaluated.

For appropriately equipped modules, additional diagnostic procedures such as digital or analog cable loopback tests are available. Suitable additional test wiring is required for these tests. This allows the modules to be examined specifically during commissioning, functional testing, and troubleshooting.

Typical application scenarios for the BS series

The DEDITEC BS series is suitable for measurement, control, and automation tasks that require numerous digital signals or combined analog and digital I/O functions. With different channel counts and communication interfaces, the modules can be integrated into both new installations and existing control and test systems.

The following application scenarios show how BS-USB and BS-WEU modules can be used for different technical requirements.

DDT-Icon_Prüfstands-und-Testsysteme

Machine and plant engineering – acquire numerous signals and switch outputs

In machines and production systems, numerous limit switches, operating states, and feedback signals often need to be acquired, while valves, relays, or other electrical loads need to be controlled.

For these applications, the BS series offers digital I/O modules with high channel counts. Depending on the variant, up to 128 digital inputs or outputs, or 64 inputs and 64 outputs, can be provided within a single module. With their standard Ethernet interface, BS-WEU modules can be integrated via Modbus TCP into suitably equipped control and automation systems.

DDT-Icon_Maschinen-und-Anlagenautomation

Automated test benches – combine digital and analog signals

In automated test benches, devices under test often need to be controlled with defined signals, measured values need to be acquired, and individual test steps need to be coordinated by a PC application.

For such tasks, the BS-WEU product family offers variants with analog and digital I/O functions. For example, 16 analog inputs and four analog outputs can be combined with additional digital inputs and outputs. With these combined analog/digital modules, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, is available. The modules can be integrated into the test bench software via USB or Ethernet. The analog inputs acquire measurement signals, while digital outputs can perform switching operations within the test sequence.

DDT-Icon_Gebaeude-und-Facility-Automation

Building and utility systems – centrally monitor technical states

In building, energy, and utility systems, numerous technical states often need to be acquired and electrical loads controlled. These can include operating and fault signals, level switches, and the control of suitable pump or ventilation components.

For these tasks, BS modules with optocoupler-isolated inputs as well as relay or MOSFET outputs are available. BS-WEU modules can be integrated into suitable automation environments via their standard Ethernet and WiFi/WLAN interfaces. The available I/O functions can then be accessed via the corresponding software or communication interfaces.

DDT-Icon_Entwicklungspruefstaende-und-Sondermaschinen

CAN-based machine communication – transmit digital signals via the CAN bus

In machines and automation systems using CAN communication, digital input signals can be acquired and control information can be exchanged between the BS module and other CAN nodes.

Both BS-USB and BS-WEU are available with an optional CAN interface. Supported functions include RAW CAN and SAE J1939 as well as configurable transmit and receive functions. This makes it possible, for example, to transmit digital switching states via CAN or use received CAN messages to control corresponding outputs. CAN communication can be configured via the ICT-Tool.

DDT-Icon_Praxisbeispiel-Steuergeraetepruefung

Expand existing control and test systems via RS-232

When modernizing existing machines, industrial PCs, or test benches, a serial interface is often already available. If additional inputs and outputs are required, a suitable BS variant can be integrated without necessarily having to establish a new Ethernet infrastructure.

Optional RS-232 interfaces are available for both BS-USB and BS-WEU. Digital inputs can be read and outputs can be controlled via serial communication. This makes it possible to extend existing control and test applications with additional I/O functions, provided that the required communication interface is supported.

Which DEDITEC I/O series is right for my application?

DEDITEC offers different I/O series for industrial measurement, control, and automation tasks. Which series is best suited depends primarily on the required channel count, signal types, form factor, communication interfaces, and desired expandability.

The BS series is particularly suitable when a large number of digital inputs or outputs is required within a stand-alone module with an aluminum enclosure. For modularly expandable I/O systems, the NET series is a suitable choice. The UC series is designed for compact stand-alone applications, while the RO series is particularly suitable when low installation depth and project-specific I/O combinations are required.

Which series is suitable for which requirements?

Requirement More suitable series
Many digital inputs or outputs in a closed aluminum enclosure BS series
High channel counts with a predefined I/O configuration BS series
Combine analog and digital I/Os within a single module – with up to 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs BS-WEU
Build a modular system and expand it later with additional I/O modules NET series
Combine many different I/O types within a scalable system NET series
Compact stand-alone I/O module for small to medium-sized applications UC series
Compact I/O integration via CANopen UC-CANopen
Particularly low installation depth RO series
Specialized functions in a particularly low-profile design RO series
No later modular expansion required BS, UC, or RO – depending on the I/O requirements and form factor

BS series – many I/Os in a robust aluminum enclosure

The BS series is particularly suitable for applications that require a large number of digital inputs or outputs within a stand-alone I/O module. The BS-USB and BS-WEU product families offer different channel counts and predefined I/O configurations. BS-WEU additionally includes analog and combined analog/digital variants.

The BS series is especially suitable when the required I/O configuration is already defined and no later modular expansion, as offered by the NET series, is planned.

NET series – modularly expandable remote I/O system

The NET series is designed for applications where different I/O types need to be combined and expanded later if required. A central NET CPU handles communication and supplies the connected I/O modules. The required digital, analog, and specialized I/O functions can be configured according to the application.

The NET series is therefore particularly suitable for more extensive measurement, testing, and automation systems with a flexible system architecture and potential future expansion requirements.

UC series – compact stand-alone I/O modules

The UC series is suitable for small to medium-sized measurement, control, and automation tasks where a compact, ready-to-use I/O module is required. Depending on the variant, digital, analog, or temperature-related I/O functions are available. Different versions with USB, Ethernet, CAN, or CANopen can be selected for communication.

The UC series is particularly suitable when the I/O requirements are already largely defined and no extensive, freely configurable system architecture is required.

RO series – particularly low-profile I/O modules

The RO series is particularly suitable for applications where only limited installation depth is available or where different I/O functions need to be combined in a low-profile module design. Depending on the variant, digital, analog, and other specialized I/O functions are available.

The available module variants allow different signal types to be combined according to the requirements of the respective application. The RO series is therefore particularly suitable for measurement, testing, and automation tasks where form factor, installation space, and the required I/O combination are key selection criteria.

Which criteria are decisive when selecting the right I/O series?

  1. Channel count: How many digital or analog inputs and outputs are required?
  2. Signal types: Do digital states, analog measured values, switching outputs, or specialized signals need to be processed?
  3. Communication interface: Should the connection be made, for example, via USB, Ethernet, CAN, or CANopen?
  4. Expandability: Is a predefined I/O configuration sufficient, or should the system be modularly expandable at a later stage?
  5. Form factor: What requirements apply to the enclosure, mounting, and available installation space?

In simplified terms: Many I/Os in an aluminum enclosure → BS | Modularly expandable → NET | Compact and stand-alone → UC | Particularly low-profile → RO.
The final product selection also depends on the electrical requirements and the I/O and interface variants actually available.

Development, long-term availability, and technical support

For industrial I/O modules, long-term availability, documentation, and support for integration and service are just as important as the technical features. DEDITEC relies on a modular development approach that makes it easier to modify individual assemblies.

Benefit Benefit for users
Modular product development Individual assemblies can be revised in a targeted manner when component availability changes.
10 years of long-term availability Long-term availability of BS modules and suitable components for industrial applications.
Technical support Support with questions about products, commissioning, and software.
Software and integration DELIB/API, sample programs, ICT-Tool, and documented communication protocols.
Slider-Logo_Made in Germany

Modular development for long-term product availability

DEDITEC uses a modular approach in hardware development. This allows individual assemblies to be revised when required, for example if certain electronic components are no longer available.

Instead of having to redesign an entire product, only the affected assemblies can be adapted. This approach supports long-term product availability and makes it easier to respond to changes in the availability of electronic components.

Slider-Logo_DDT-Guetesiegel

Technical support for commissioning and integration

DEDITEC provides technical support for questions relating to its I/O modules as well as for commissioning. For the BS series, this particularly includes questions concerning communication, configuration, and software integration. Users can make use of the available technical information and software tools and contact DEDITEC support if required.

This also provides suitable support options for integrating BS modules into custom measurement, testing, and control applications.

DDT 20 002 USP Leiste 10 Jahre Teil 02

10 years of long-term availability

DEDITEC offers 10 years of long-term availability for the BS series. This includes the long-term availability of the products and suitable components for future reordering.

This supports long-term planning for measurement, testing, and automation projects where replacement units or additional products may be required over an extended period.

The modular product development approach supports this strategy, as individual assemblies can be adapted in a targeted manner when component availability changes.

Slider-Logo_DDT-Guetesiegel

Custom software and firmware adaptations

DEDITEC also offers custom software and firmware adaptations for the BS-USB and BS-WEU product families.

If the existing standard functions are not sufficient for an application, individual requirements relating to control, communication, or the processing of I/O signals can be taken into account as part of a project-specific adaptation.

Slider-Logo_Made in Germany

Made in Germany – entwickelt und gefertigt in Deutschland

Die DEDITEC BS-Serie wird in Deutschland entwickelt und gefertigt. Dies gilt sowohl für die BS-USB- als auch für die BS-WEU-Produktfamilie.
Damit gehören Entwicklung und Fertigung in Deutschland zu den bestätigten Herstellermerkmalen der BS-Serie.

DDT 20 002 USP Leiste Teil 04

Software, documentation, and sample code

DEDITEC provides comprehensive software tools and programming interfaces for integrating the BS series. The available I/O functions can be integrated into custom applications via the DELIB driver library.

In addition, sample programs with source code are available for various programming languages, as well as the ICT-Tool for configuration, functional testing, and diagnostics. For modules with suitable communication interfaces, the documented DEDITEC protocols can also be used. This allows BS modules to be integrated directly into project-specific software solutions.

Frequently asked questions about the BS series

What is the DEDITEC BS series?

:
;
The DEDITEC BS series comprises robust I/O modules in aluminum enclosures for industrial measurement, control, and automation tasks. It is particularly suitable for applications with high digital channel counts and predefined I/O configurations. The product range consists of BS-USB and BS-WEU. Depending on the variant, digital inputs, relay or MOSFET outputs, and, with BS-WEU, analog inputs and outputs are available.

What is the difference between BS-USB and BS-WEU?

:
;
BS-USB offers digital I/O modules with a total of 32 channels, either as input-only or output-only variants or in a combined configuration. BS-WEU includes purely digital variants with 16 to 128 channels as well as analog and combined analog/digital versions. For analog modules, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, is available.

Unlike BS-USB, BS-WEU includes USB, Ethernet, and WiFi/WLAN as standard interfaces. CAN and serial RS-232 interfaces are optionally available for both product families.

How many inputs and outputs does the BS series provide?

:
;
BS-USB modules provide a total of 32 digital channels. Depending on the variant, purely digital BS-WEU modules provide 16, 32, 64, 96, or 128 channels. Input-only or output-only modules as well as combined variants are available, for example with 64 digital inputs and 64 digital outputs. For BS-WEU modules with analog I/O functions, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, is available. The channel count and distribution depend on the respective module variant.

Which digital and analog I/O types does the BS series offer?

:
;
For digital applications, optocoupler-isolated inputs as well as relay and MOSFET outputs are available. There are also modules that combine digital inputs and outputs. In addition, the BS-WEU product family offers variants with 16 analog inputs, four analog outputs, as well as combined analog/digital I/O modules. This allows a wide range of measurement, switching, and control tasks to be implemented.

Can BS-WEU modules also measure voltage and current signals?

:
;
Yes. The analog BS-WEU variants support different voltage measurement ranges and can also be used for current measurement. Additional shunt resistors are required for current measurement. The respective measurement type and suitable measurement range must be configured accordingly. Analog input modules with 16 channels and 16-bit resolution are available.

Which communication interfaces does the BS series support?

:
;
BS-USB includes USB as standard. BS-WEU includes USB, Ethernet, and WiFi/WLAN as standard. Users can select the communication method that best suits their application. Optional CAN and serial RS-232 interfaces are also available for both product families. The supported communication protocols depend on the interface used.

Does the BS series support Modbus TCP?

:
;
Yes. Ethernet-capable BS-WEU modules support Modbus TCP. This allows digital and analog I/O data to be read or written via registers and bits and integrated into suitably equipped control and automation systems. Alternatively, the modules can be accessed via the DELIB driver library or the open DEDITEC TCP/IP protocol.

Does the BS series support CAN and SAE J1939?

:
;
Yes. Optional CAN interfaces are available for both BS-USB and BS-WEU. RAW CAN, SAE J1939, and the DEDITEC DELIB command mode are supported. In addition, automatic transmit and receive functions can be configured, for example to transmit digital input states or process received CAN messages.

Can I integrate the BS series into my own software?

:
;
Yes. DEDITEC provides the DELIB driver library with a uniform programming interface for this purpose. DELIB can be integrated into applications using C, C++, C#, Delphi, Visual Basic, VB.NET, VBA, Java, and LabVIEW, among others. For suitable interfaces, open DEDITEC communication protocols are also available, enabling direct integration without DELIB.

Can I commission a BS module without custom programming?

:
;
Yes. The DEDITEC ICT-Tool can be used to configure, test, and diagnose BS modules without first having to develop a custom software application. The tool provides functions for configuring communication interfaces, testing inputs and outputs, performing diagnostics, and carrying out firmware updates.

Can BS modules respond automatically to input signals?

:
;
Yes. The BS series supports Event Control. Depending on the module configuration, defined input states or analog measured values can be used as event conditions. As soon as a configured condition is met, the module can automatically trigger a corresponding action, such as switching a digital output. Configuration is carried out using the ICT-Tool.

What happens to the outputs if communication is interrupted?

:
;
A configurable timeout function is available for digital outputs. It allows the output behavior to be defined in the event of a communication interruption. Depending on the configuration, individual outputs can be activated, deactivated, or left in their current state. The timeout period and the required behavior can be configured via software.

Can the BS series be expanded modularly at a later stage?

:
;
The I/O configuration of a BS module is determined by the selected product variant. Later expansion with additional I/O submodules, as with the NET series, is not supported. For applications with changing I/O requirements and planned modular expansion, the NET series may therefore be more suitable. Depending on the variant, optional CAN or RS-232 interfaces can be retrofitted to BS modules.

What is the difference between the BS series and the NET, UC, or RO series?

:
;
The BS series is particularly suitable for high digital channel counts within a stand-alone aluminum enclosure. The NET series, in contrast, has a modular architecture and allows different I/O modules to be flexibly combined and expanded at a later stage. The UC series is aimed more at compact stand-alone applications, while the RO series is particularly suitable when low installation depth and specialized I/O combinations are required.

How long are BS series products available?

:
;
DEDITEC offers 10 years of long-term availability for the BS series. This includes the long-term availability of BS-USB and BS-WEU modules as well as suitable components for future reordering. This supports long-term project planning as well as later replacement and repeat orders.

Find the right BS module for your application

Select the appropriate I/O module from the DEDITEC BS series based on signal type, channel count, I/O configuration, and communication interface. Depending on the application, BS-USB and BS-WEU variants are available with digital inputs, relay or MOSFET outputs, as well as combined analog and digital I/O functions.

If you need assistance selecting the appropriate module or integrating it into your existing measurement, control, or automation environment, DEDITEC can support you with the technical product selection.

Select BS products

Discover the available BS-USB and BS-WEU modules and select the appropriate variant based on I/O function, channel count, and communication interface.

Support with selection

Not sure which BS variant provides the required inputs and outputs, interfaces, or electrical characteristics? DEDITEC can assist you in selecting the appropriate I/O module.

Not sure which BS module is right for you?

Do you need support choosing between BS-USB and BS-WEU, or do you have questions about channel counts, signal types, interfaces, and software integration? DEDITEC can help you find a suitable module variant for your application.

Helpful information for your inquiry:

  • Required communication interface, e.g. USB, Ethernet, WiFi/WLAN, CAN, or RS-232
  • Number and type of required digital and analog inputs and outputs
  • Required voltage and current ranges
  • Type and electrical requirements of the loads to be switched
  • Required relay or MOSFET outputs
  • Software, programming language, or communication protocols used
  • Special requirements such as Event Control, timeout functions, or Modbus TCP
My cart
Your cart is empty.

Looks like you haven't made a choice yet.