BS series – robust I/O modules for high channel counts
The DEDITEC BS series comprises robust I/O modules in aluminum enclosures for industrial measurement, control, and automation tasks. It is particularly suitable for applications that require a large number of digital inputs and outputs within a stand-alone module. Depending on the variant, digital inputs with optocouplers as well as relay or MOSFET outputs are available. In addition, the BS-WEU product family also provides analog inputs and outputs.
The BS series is divided into the BS-USB and BS-WEU product families. While BS-USB modules provide digital I/O configurations with a total of 32 channels, BS-WEU includes purely digital variants with 16 to 128 channels as well as analog and combined variants. For modules with analog I/O functions, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, can be combined. BS-USB uses USB as its standard interface. BS-WEU includes USB, Ethernet, and WiFi/WLAN as standard interfaces. CAN and serial RS-232 interfaces are optionally available for both product families.
With their high channel counts, robust aluminum enclosure design, and DIN rail mounting, the BS series is particularly suitable for PC-based measurement and control systems, test benches, and industrial automation applications.
- The BS series at a glance
- Which applications is the BS series suitable for?
- When is the BS series the right choice?
- BS-USB or BS-WEU – which variant is right?
- Digital and analog I/Os of the BS series
- How to select the right BS module
- BS modules by function
- Control and software integration
- Additional functions of the BS series
- Typical application scenarios
- Which DEDITEC I/O series is right?
- Development, long-term availability, and support
- Frequently asked questions about the BS series
- Find the right BS module
The BS series at a glance
| Feature | Benefit |
|---|---|
| Robust aluminum enclosure | Closed enclosure design for industrial measurement, control, and automation applications. |
| High digital channel counts | Purely digital BS-WEU variants with 16 to 128 channels. For analog I/O combinations, a maximum of 32 digital inputs or outputs, or 16 inputs and 16 outputs. |
| BS-USB and BS-WEU | Two product families with different channel counts, I/O configurations, and communication options. |
| Digital inputs and outputs | Optocoupler-isolated inputs for state detection as well as relay or MOSFET outputs for switching and control tasks. |
| Analog I/O variants | BS-WEU additionally provides analog inputs and outputs as well as combined analog/digital variants. |
| USB, Ethernet, and WiFi/WLAN | BS-USB with USB as the standard interface. BS-WEU with USB, Ethernet, and WiFi/WLAN as standard interfaces. |
| Optional CAN and RS-232 interfaces | Additional communication options for BS-USB and BS-WEU. |
| DIN rail mounting | Mounting on a DIN rail, for example in a control cabinet. |
| DELIB/API and ICT-Tool | Software integration, configuration, functional testing, and diagnostics of the modules. |
Which applications is the BS series suitable for?
Test benches and automated test systems
Machine and plant automation
Production and process monitoring
Control of numerous electrical loads
Analog measurement and control tasks
Laboratory, development, and research systems
When is the BS series the right choice?
The BS series is particularly suitable when:
- a large number of digital inputs or outputs is required within a single module,
- digital states need to be acquired or numerous electrical loads need to be switched via relay or MOSFET outputs,
- a closed aluminum enclosure for DIN rail mounting is required,
- a predefined I/O configuration without later modular expansion is planned,
- analog and digital signals need to be combined within a single module (BS-WEU),
- USB connectivity is required for BS-USB, or communication via USB, Ethernet, or WiFi/WLAN is required for BS-WEU,
- optional CAN or serial RS-232 interfaces are required,
- the modules need to be integrated into custom PC-based measurement, testing, or control applications.
BS series or modular I/O system?
In contrast, the NET series is designed for modularly expandable I/O systems. Different I/O modules can be combined via a central NET CPU, and the system configuration can be expanded as required.
If a large number of inputs and outputs is required in a predefined configuration, the BS series can be a suitable solution. If different I/O types need to be combined flexibly or additional modules may be added later, the NET series is generally the better choice.
| If you need … | More suitable |
|---|---|
| Many digital I/Os within a stand-alone module | BS series |
| Closed aluminum enclosure with DIN rail mounting | BS series |
| High channel counts with a predefined I/O configuration | BS series |
| Modularly expandable I/O architecture | NET series |
| Flexible combination of different I/O modules | NET series |
| Later expansion with additional I/O modules | NET series |
BS-USB or BS-WEU?
When is the BS series less suitable?
The BS series is generally not the first choice when:
- the I/O system is intended to be expanded later with additional I/O modules featuring different functions,
- a particularly compact design for smaller measurement and control tasks is the main priority,
- a particularly low installation depth is required,
- a freely configurable combination of different I/O functions and specialized functions within a modular architecture is required.
In these cases, it should be evaluated whether the NET, UC, or RO series is better suited to the respective requirements.
BS-USB or BS-WEU – which variant is right for your application?
While BS-USB is designed for digital I/O applications with a total of 32 channels, BS-WEU offers a wider range of digital channel counts as well as additional analog and combined I/O variants. This allows the appropriate product family to be selected according to the required signals and the intended system connection.
| Feature | BS-USB | BS-WEU |
|---|---|---|
| Digital channel counts | 32 channels | 16, 32, 64, 96, or 128 channels for purely digital variants |
| Digital inputs | Optocoupler-isolated | Optocoupler-isolated |
| Digital outputs | Relay or MOSFET | Relay or MOSFET |
| I/O configuration | Input-only, output-only, or combined | Input-only, output-only, or combined |
| Analog inputs/outputs | Not available | Analog and combined analog/digital variants; additionally, a maximum of 32 digital inputs or outputs, or 16 inputs and 16 outputs |
| USB | Standard interface | Standard interface |
| Ethernet / WiFi | Not available for the current BS-USB variants | Standard interface |
| CAN / RS-232 | Optional | Optional |
| Enclosure / mounting | Aluminum / DIN rail | Aluminum / DIN rail |
| Software integration | DELIB/API; ICT-Tool | DELIB/API; ICT-Tool |
BS-USB – digital I/O modules for PC connectivity
Communication is provided via USB as standard. For applications with corresponding communication requirements, optional CAN or serial RS-232 interfaces are available.
BS-WEU – high channel counts and additional analog I/Os
BS-WEU also provides modules with analog inputs and outputs as well as combined analog/digital variants. In these configurations, a maximum of 32 digital inputs or 32 digital outputs, or 16 digital inputs and 16 digital outputs, can be combined with the analog functions. USB, Ethernet, and WiFi/WLAN are included as standard with all BS-WEU modules. CAN and serial RS-232 interfaces are optionally available.
Which BS product family should I choose?
The choice between BS-USB and BS-WEU primarily depends on the required channel count, signal types, and communication interface.
- Choose BS-USB if 32 digital I/O channels are sufficient and a direct USB connection to a control PC is required.
- Choose BS-WEU if different or higher digital channel counts are required, analog signals need to be processed, or Ethernet/WiFi connectivity is required as standard. For combined analog/digital variants, the limited number of digital channels must be taken into account.
- Consider the optional interfaces if the application needs to communicate via CAN or RS-232.
Digital and analog I/Os of the BS series
The selection depends primarily on the required signal type, channel count, output technology, and the electrical requirements of the respective application.
| I/O category | Example variants | Function |
|---|---|---|
| Digital inputs | BS-USB-O32, BSW-O16, BSW-O64, BSW-O128 | Acquire digital states via optocouplers |
| Relay outputs | BS-USB-R32, BSW-R16, BSW-R64, BSW-R128 | Switch electrical loads and circuits |
| MOSFET outputs | BS-USB-M32, BSW-M16, BSW-M64, BSW-M128 | Electronic switching and control tasks |
| Combined digital I/Os | BS-USB-O16-R16, BS-USB-O16-M16, BSW-O32-R32, BSW-O64-M64 | Acquire digital states and switch outputs within the same module |
| Analog inputs | BSW-AD16 | Acquire analog voltage and current signals |
| Analog inputs and outputs | BSW-AD16-DA4_16 | Acquire analog measured values and output setpoint or control signals |
| Combined analog and digital I/Os | BSW-AD16-DA4_16-OR16, BSW-AD16-DA4_16-OR3A, BSW-AD16-DA4_16-OM16 | 16 analog inputs, four analog outputs, 16 digital inputs, and 16 relay or MOSFET outputs each. The output technology and load capacity vary depending on the variant. |
Digital inputs with optocouplers
The digital inputs also provide additional evaluation functions. These include 16-bit counters for each channel, programmable input filters, and detection of state changes between two read operations. This makes the modules suitable, for example, for acquiring switching states, binary process signals, and digital test signals.
Relay outputs for electrical switching tasks
The selection of the appropriate relay module depends primarily on the required number of switching channels as well as the voltage, current, and type of loads to be connected.
MOSFET outputs for electronic switching tasks
Which variant is suitable depends, among other factors, on the required channel count, supply voltage, and the electrical characteristics of the load to be switched.
Analog inputs for voltage and current signals
Configurable digital filter functions are also available, allowing measured values to be smoothed by averaging.
Analog outputs for setpoint and control signals
The analog outputs support different voltage signals. This makes it possible, for example, to provide analog setpoints or control signals within a measurement or control application.
Combined digital and analog inputs and outputs
The combined BS-WEU variants BSW-AD16-DA4_16-OR16, BSW-AD16-DA4_16-OR3A, and BSW-AD16-DA4_16-OM16 each provide 16 analog inputs (16-bit), four analog outputs (16-bit), 16 digital inputs, and 16 digital outputs. They differ in their output technology: OR16 provides 1 A relay outputs, OR3A provides 3 A relay outputs, and OM16 provides 3 A MOSFET outputs. This allows analog measured values, digital states, and electrical switching tasks to be combined within a single module. For analog BS-WEU variants, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, is available.
Which I/O type is right for your application?
- Choose digital inputs when switching states or other binary signals need to be acquired.
- Choose relay outputs when electrical loads need to be switched via relay contacts.
- Choose MOSFET outputs when suitable DC loads need to be switched electronically.
- Choose analog inputs when voltage or current signals need to be measured.
- Choose analog outputs when analog setpoints or control signals need to be output.
- Choose combined I/O modules when different input and output functions are required within a single module.
How to select the right BS module
The following selection criteria help identify a suitable BS-USB or BS-WEU variant for the respective measurement, control, or automation task.
1. Define the required signal types
If analog voltage or current signals need to be acquired or analog control signals need to be output, suitable BS-WEU variants are available. Combinations of analog and digital I/O functions within a single module are also possible.
2. Determine the channel count and I/O combination
Depending on the variant, input-only, output-only, or combined modules are available. For example, the BS-USB-O16-R16 provides a total of 16 digital inputs and 16 relay outputs. The BSW-O48-R48, in contrast, provides 48 digital inputs and 48 relay outputs within a single module.
It is important to consider not only the total number of channels but also how they are distributed. The available combinations are defined by the respective module variants.
3. Check the output technology and electrical requirements
When selecting a module, the required voltage, switching current, load type, and permissible load capacity of the respective outputs must be taken into account. Since the BS series offers different output variants, these electrical characteristics should always be checked for the specific module.
4. Select the communication interface
The appropriate interface depends on how the BS module is to be integrated into the existing measurement, control, or automation environment.
- USB: Direct connection to a control PC or PC-based measurement and test system.
- Ethernet: Standard interface of BS-WEU modules for integration into IP-based networks and communication via Modbus TCP.
- WiFi/WLAN: Standard wireless network interface of BS-WEU modules for integration into IP-based networks.
- CAN or RS-232: Optional communication variants for BS-USB and BS-WEU.
While USB, Ethernet, and WiFi/WLAN are included as standard with BS-WEU, CAN and RS-232 are optional interfaces. The available communication protocols depend on the selected interface.
5. Define the software and protocol integration
Examples for selecting a BS module
| Requirement | Example of a suitable variant |
|---|---|
| 16 digital inputs and 16 relay outputs | BS-USB-O16-R16 |
| 32 digital inputs | BS-USB-O32 |
| 8 digital inputs and 8 relay outputs | BSW-O8-R8 |
| 48 digital inputs and 48 relay outputs | BSW-O48-R48 |
| 128 digital inputs | BSW-O128 |
| 16 analog inputs and 4 analog outputs | BSW-AD16-DA4_16 |
The examples are intended as an initial guide. For the final product selection, the required communication interface, electrical connection values, and the specific module variant must also be taken into account.
BS modules by function
The BS-USB and BS-WEU product families offer different channel counts and communication options. For targeted module selection, the available variants can be grouped according to their I/O functions.
Digital inputs
Relay outputs
MOSFET
Combined digital I/Os
Analog / combined I/Os
Digital inputs – optocoupler modules
For purely digital BS-WEU modules, variants with 16, 32, 64, 96, or 128 digital inputs are also available. This makes it possible to implement applications with numerous digital input signals within a single module.
Digital outputs – relay and MOSFET modules
Relay outputs are suitable for conventional electrical switching tasks. MOSFET outputs enable electronic switching of suitable DC loads. Depending on the requirements, different output technologies and electrical load capacities can be selected.
Combined digital inputs and outputs
For BS-USB, for example, variants with 16 optocoupler-isolated inputs and 16 relay or MOSFET outputs are available. The purely digital BS-WEU variants additionally include combined configurations with 8, 16, 32, 48, or 64 digital inputs and the same number of outputs. This makes it possible to provide up to 64 digital inputs and 64 digital outputs within a single module.
Analog inputs and outputs
In addition, variants are available that combine 16 analog inputs with four analog outputs. These also enable the output of analog setpoint and control signals. The available measurement and output ranges depend on the respective module variant and configuration.
Combined analog and digital I/O modules
Available configurations include modules with 16 analog inputs, four analog outputs, 16 digital inputs, and 16 relay or MOSFET outputs. Depending on the variant, relay outputs with 1 A or 3 A load capacity or MOSFET outputs with 3 A load capacity are available. Analog BS-WEU modules support a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs. Variants combining analog I/Os with 64, 96, or 128 digital channels are not available.
Control the BS series and integrate it into existing systems
For integration into custom software applications, DEDITEC provides the DELIB driver library with a uniform programming interface. Alternatively, modules with suitable interfaces can be controlled via the open DEDITEC communication protocols. Ethernet-capable variants also support Modbus TCP.
The DEDITEC ICT-Tool is available for commissioning, configuration, functional testing, and diagnostics. It can be used to configure the modules and test their inputs and outputs.
| Control method / Tool | Application | Practical benefit |
|---|---|---|
| DELIB/API | Custom PC and software applications | Unified software integration and access to I/O functions |
| USB | BS-USB and BS-WEU; local PC-based measurement and control systems | Direct connection between the control PC and BS module |
| Ethernet / TCP/IP | BS-WEU; Ethernet interface included as standard | Network-based integration and communication via TCP/IP |
| WiFi/WLAN | BS-WEU; WiFi/WLAN interface included as standard | Wireless integration into an IP network |
| Modbus TCP | PLC, SCADA, and industrial network applications | Standardized register- and bit-based access to I/O data |
| CAN / RAW CAN / SAE J1939 | CAN-based control systems | Transmission and processing of CAN messages |
| RS-232 | Systems with serial communication | Connection via optional serial interface |
| Open DEDITEC protocols | Custom software and system integration | Direct communication without DELIB via suitable interfaces |
| DELIB CLI | Scripts and automated tests | Control of supported modules via the command line |
| ICT-Tool | Commissioning, configuration, and diagnostics | Configure modules, test I/Os, and update firmware |
| Web interface | Suitable network-capable modules | Browser-based configuration and operation |
Custom applications with DELIB and API
The DELIB driver library enables integration of the BS series into custom software applications. The uniform API provides access to digital inputs and outputs and, for appropriately equipped BS-WEU modules, analog inputs and outputs.
DEDITEC supports C, C++, C#, Delphi, Visual Basic, VB.NET, and VBA, among others. Integration with Java and LabVIEW is also possible. For Java, different integration methods apply depending on the interface used.
DELIB is available for Windows and Linux. In addition, DEDITEC provides sample programs with source code to simplify the development of custom measurement, testing, and control applications.
CAN – RAW CAN, SAE J1939, and automatic message processing
Optional CAN interfaces are available for both BS-USB and BS-WEU. These enable the modules to be integrated into CAN-based measurement, control, and automation systems.
RAW CAN, SAE J1939, and the DEDITEC DELIB command mode are supported. With RAW CAN, messages with 11-bit or 29-bit identifiers can be processed. For SAE J1939, addressing is configured using the corresponding message parameters.
Configurable functions for automatically transmitting and receiving CAN messages are also available. Depending on the module configuration, digital input states or analog measured values can be transmitted, for example, while received data can be used to control corresponding outputs. CAN communication is configured via the ICT-Tool.
Control via the command line with DELIB CLI
DELIB CLI can be used to control supported BS modules via the command line. This option is available for USB and Ethernet modules under Windows and Linux.
Command-line control is suitable, for example, for automated tests, scripts, and recurring control sequences. Depending on the module configuration, digital and analog inputs and outputs can be read or controlled.
USB – direct connection to the control PC
USB enables a local connection between a BS module and a control PC or USB hub. The BS-USB product family uses USB as its standard interface. All BS-WEU modules also feature an integrated USB interface. In addition, BS-WEU includes Ethernet and WiFi/WLAN as standard.
This connection is particularly suitable for PC-based test benches, laboratory setups, and measurement and control applications where the modules are to be connected directly to a computer. The available inputs and outputs can be accessed from the respective software application via the DELIB driver library.
RS-232 – serial communication
In addition to CAN, DEDITEC optionally offers a serial RS-232 interface for both BS product families. This enables the modules to be integrated into applications that use serial communication. The DELIB driver library or the corresponding open DEDITEC communication protocols can be used for integration.
Commissioning and diagnostics with the ICT-Tool
The DEDITEC ICT-Tool can be used to configure, test, and diagnose BS modules without first having to develop a custom software application. Available functions include testing digital and analog inputs and outputs, configuring communication interfaces, performing functional tests, and using diagnostic functions.
Firmware updates can also be carried out via the ICT-Tool. For modules with corresponding additional functions, further settings can be configured, for example for CAN communication or monitoring functions.
Ethernet and WiFi – I/O communication via TCP/IP and Modbus TCP
All BS-WEU modules include Ethernet and WiFi/WLAN as standard and can therefore be integrated into an IP-based network via the appropriate interface. Communication via Ethernet can be carried out using TCP/IP. For this purpose, either DELIB/API or the open DEDITEC TCP/IP protocol can be used, or alternatively Modbus TCP.
Modbus TCP enables standardized access to I/O data via registers and bits. This allows suitable BS-WEU modules to be integrated, for example, into industrial control, test bench, and automation systems with corresponding Modbus TCP support. The communication protocols that can be used depend on the interface and the functions supported by the module.
Open DEDITEC protocols for custom software solutions
For BS modules with Ethernet, CAN, or serial interfaces, DEDITEC provides open communication protocols. These enable direct control at the protocol level without necessarily requiring the DELIB driver library.
Communication via Ethernet is carried out using TCP/IP, while the respective communication protocols are available for CAN and RS-232. This allows developers to integrate the BS series into custom software and system architectures that require direct communication with the hardware.
Web interface for network-capable BS modules
Suitable network-capable BS modules also feature an integrated web interface. Network settings can be configured via a browser, while available inputs and outputs can be displayed and controlled. Access to the web interface is protected by user login.
The web interface therefore complements software-based control via DELIB, open DEDITEC protocols, or Modbus TCP.
More than basic I/O – additional functions of the BS series
Depending on the module configuration and communication interface, additional functions are also available for direct data exchange between modules, processing analog measured values, and diagnostics. This makes it possible to implement more complex tasks within an existing control or software environment.
Digital inputs with counter functions
The internal counter logic supports frequencies of up to 10 kHz and provides a latch function for capturing counter values. The counter values can be read via software and used for further evaluation. This makes it possible, for example, to acquire switching pulses or recurring digital signal events within a measurement or control application.
Digital input filters and state change detection
In addition, the BS modules can detect state changes between two read operations. Internal logic detects transitions from High to Low or from Low to High and stores this information in a register. This allows signal changes that occur between two regular input queries to be detected as well.
Event Control – trigger actions automatically
For example, a digital input signal can be used as a trigger to switch a digital output. With appropriately equipped BS-WEU modules, analog input values can also be used as event conditions.
The available conditions and actions depend on the respective module configuration. In addition to digital switching actions, suitable variants can also set analog output signals or trigger CAN messages.
The event conditions and actions can be configured via the ICT-Tool. This allows certain responses to be executed directly by the module without requiring every individual action to be triggered by the higher-level PC application.
Timeout protection for digital outputs
For individual output channels, it can be configured whether they are to be activated, deactivated, or remain in their current state when a timeout occurs. The time until the timeout function is triggered can also be configured.
Several timeout operating modes are available for different requirements. This allows the output behavior to be adapted to the respective measurement, testing, or control application. The timeout function supplements communication monitoring but does not replace an independent safety-related control system.
M2M communication – direct data exchange between modules
All BS-WEU modules with digital or analog inputs support M2M via Ethernet. This allows input states or measured values to be transferred directly between appropriately equipped DEDITEC modules without requiring each data transfer to be triggered by a higher-level PC application.
Alternatively, M2M communication via CAN is possible. For this purpose, automatic transmit and receive functions (TX/RX) are used. These are generally available for all modules equipped with a CAN interface. Since CAN is optionally available for both BS-USB and BS-WEU, appropriately equipped BS-USB modules can also participate in CAN-based M2M communication.
Which signals can be transmitted or processed depends on the I/O configuration and the communication interface used.
Smooth analog measured values using filter functions
The filter can be configured via software. It should be noted that stronger averaging reduces the available sampling rate. This allows the processing of analog measured values to be adapted to the requirements of the respective measurement or testing task.
Advanced diagnostic and testing functions
For appropriately equipped modules, additional diagnostic procedures such as digital or analog cable loopback tests are available. Suitable additional test wiring is required for these tests. This allows the modules to be examined specifically during commissioning, functional testing, and troubleshooting.
Typical application scenarios for the BS series
The following application scenarios show how BS-USB and BS-WEU modules can be used for different technical requirements.
Machine and plant engineering – acquire numerous signals and switch outputs
For these applications, the BS series offers digital I/O modules with high channel counts. Depending on the variant, up to 128 digital inputs or outputs, or 64 inputs and 64 outputs, can be provided within a single module. With their standard Ethernet interface, BS-WEU modules can be integrated via Modbus TCP into suitably equipped control and automation systems.
Automated test benches – combine digital and analog signals
For such tasks, the BS-WEU product family offers variants with analog and digital I/O functions. For example, 16 analog inputs and four analog outputs can be combined with additional digital inputs and outputs. With these combined analog/digital modules, a maximum of 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs, is available. The modules can be integrated into the test bench software via USB or Ethernet. The analog inputs acquire measurement signals, while digital outputs can perform switching operations within the test sequence.
Building and utility systems – centrally monitor technical states
For these tasks, BS modules with optocoupler-isolated inputs as well as relay or MOSFET outputs are available. BS-WEU modules can be integrated into suitable automation environments via their standard Ethernet and WiFi/WLAN interfaces. The available I/O functions can then be accessed via the corresponding software or communication interfaces.
CAN-based machine communication – transmit digital signals via the CAN bus
Both BS-USB and BS-WEU are available with an optional CAN interface. Supported functions include RAW CAN and SAE J1939 as well as configurable transmit and receive functions. This makes it possible, for example, to transmit digital switching states via CAN or use received CAN messages to control corresponding outputs. CAN communication can be configured via the ICT-Tool.
Expand existing control and test systems via RS-232
Optional RS-232 interfaces are available for both BS-USB and BS-WEU. Digital inputs can be read and outputs can be controlled via serial communication. This makes it possible to extend existing control and test applications with additional I/O functions, provided that the required communication interface is supported.
Which DEDITEC I/O series is right for my application?
The BS series is particularly suitable when a large number of digital inputs or outputs is required within a stand-alone module with an aluminum enclosure. For modularly expandable I/O systems, the NET series is a suitable choice. The UC series is designed for compact stand-alone applications, while the RO series is particularly suitable when low installation depth and project-specific I/O combinations are required.
| Requirement | More suitable series |
|---|---|
| Many digital inputs or outputs in a closed aluminum enclosure | BS series |
| High channel counts with a predefined I/O configuration | BS series |
| Combine analog and digital I/Os within a single module – with up to 32 digital inputs or outputs, or 16 digital inputs and 16 digital outputs | BS-WEU |
| Build a modular system and expand it later with additional I/O modules | NET series |
| Combine many different I/O types within a scalable system | NET series |
| Compact stand-alone I/O module for small to medium-sized applications | UC series |
| Compact I/O integration via CANopen | UC-CANopen |
| Particularly low installation depth | RO series |
| Specialized functions in a particularly low-profile design | RO series |
| No later modular expansion required | BS, UC, or RO – depending on the I/O requirements and form factor |
BS series – many I/Os in a robust aluminum enclosure
The BS series is especially suitable when the required I/O configuration is already defined and no later modular expansion, as offered by the NET series, is planned.
NET series – modularly expandable remote I/O system
The NET series is therefore particularly suitable for more extensive measurement, testing, and automation systems with a flexible system architecture and potential future expansion requirements.
UC series – compact stand-alone I/O modules
The UC series is particularly suitable when the I/O requirements are already largely defined and no extensive, freely configurable system architecture is required.
RO series – particularly low-profile I/O modules
The available module variants allow different signal types to be combined according to the requirements of the respective application. The RO series is therefore particularly suitable for measurement, testing, and automation tasks where form factor, installation space, and the required I/O combination are key selection criteria.
Which criteria are decisive when selecting the right I/O series?
- Channel count: How many digital or analog inputs and outputs are required?
- Signal types: Do digital states, analog measured values, switching outputs, or specialized signals need to be processed?
- Communication interface: Should the connection be made, for example, via USB, Ethernet, CAN, or CANopen?
- Expandability: Is a predefined I/O configuration sufficient, or should the system be modularly expandable at a later stage?
- Form factor: What requirements apply to the enclosure, mounting, and available installation space?
In simplified terms: Many I/Os in an aluminum enclosure → BS | Modularly expandable → NET | Compact and stand-alone → UC | Particularly low-profile → RO.
The final product selection also depends on the electrical requirements and the I/O and interface variants actually available.
Development, long-term availability, and technical support
For industrial I/O modules, long-term availability, documentation, and support for integration and service are just as important as the technical features. DEDITEC relies on a modular development approach that makes it easier to modify individual assemblies.
| Benefit | Benefit for users |
|---|---|
| Modular product development | Individual assemblies can be revised in a targeted manner when component availability changes. |
| 10 years of long-term availability | Long-term availability of BS modules and suitable components for industrial applications. |
| Technical support | Support with questions about products, commissioning, and software. |
| Software and integration | DELIB/API, sample programs, ICT-Tool, and documented communication protocols. |
Modular development for long-term product availability
DEDITEC uses a modular approach in hardware development. This allows individual assemblies to be revised when required, for example if certain electronic components are no longer available.
Instead of having to redesign an entire product, only the affected assemblies can be adapted. This approach supports long-term product availability and makes it easier to respond to changes in the availability of electronic components.
Technical support for commissioning and integration
DEDITEC provides technical support for questions relating to its I/O modules as well as for commissioning. For the BS series, this particularly includes questions concerning communication, configuration, and software integration. Users can make use of the available technical information and software tools and contact DEDITEC support if required.
This also provides suitable support options for integrating BS modules into custom measurement, testing, and control applications.
10 years of long-term availability
DEDITEC offers 10 years of long-term availability for the BS series. This includes the long-term availability of the products and suitable components for future reordering.
This supports long-term planning for measurement, testing, and automation projects where replacement units or additional products may be required over an extended period.
The modular product development approach supports this strategy, as individual assemblies can be adapted in a targeted manner when component availability changes.
Custom software and firmware adaptations
DEDITEC also offers custom software and firmware adaptations for the BS-USB and BS-WEU product families.
If the existing standard functions are not sufficient for an application, individual requirements relating to control, communication, or the processing of I/O signals can be taken into account as part of a project-specific adaptation.
Made in Germany – entwickelt und gefertigt in Deutschland
Die DEDITEC BS-Serie wird in Deutschland entwickelt und gefertigt. Dies gilt sowohl für die BS-USB- als auch für die BS-WEU-Produktfamilie.
Damit gehören Entwicklung und Fertigung in Deutschland zu den bestätigten Herstellermerkmalen der BS-Serie.
Software, documentation, and sample code
DEDITEC provides comprehensive software tools and programming interfaces for integrating the BS series. The available I/O functions can be integrated into custom applications via the DELIB driver library.
In addition, sample programs with source code are available for various programming languages, as well as the ICT-Tool for configuration, functional testing, and diagnostics. For modules with suitable communication interfaces, the documented DEDITEC protocols can also be used. This allows BS modules to be integrated directly into project-specific software solutions.
Frequently asked questions about the BS series
What is the DEDITEC BS series?
What is the difference between BS-USB and BS-WEU?
Unlike BS-USB, BS-WEU includes USB, Ethernet, and WiFi/WLAN as standard interfaces. CAN and serial RS-232 interfaces are optionally available for both product families.
How many inputs and outputs does the BS series provide?
Which digital and analog I/O types does the BS series offer?
Can BS-WEU modules also measure voltage and current signals?
Which communication interfaces does the BS series support?
Does the BS series support Modbus TCP?
Does the BS series support CAN and SAE J1939?
Can I integrate the BS series into my own software?
Can I commission a BS module without custom programming?
Can BS modules respond automatically to input signals?
What happens to the outputs if communication is interrupted?
Can the BS series be expanded modularly at a later stage?
What is the difference between the BS series and the NET, UC, or RO series?
How long are BS series products available?
Find the right BS module for your application
If you need assistance selecting the appropriate module or integrating it into your existing measurement, control, or automation environment, DEDITEC can support you with the technical product selection.
Select BS products
Support with selection
Not sure which BS module is right for you?
Helpful information for your inquiry:
- Required communication interface, e.g. USB, Ethernet, WiFi/WLAN, CAN, or RS-232
- Number and type of required digital and analog inputs and outputs
- Required voltage and current ranges
- Type and electrical requirements of the loads to be switched
- Required relay or MOSFET outputs
- Software, programming language, or communication protocols used
- Special requirements such as Event Control, timeout functions, or Modbus TCP
Install the installation program and check the module functions.