{"id":25587934,"date":"2026-04-14T08:41:38","date_gmt":"2026-04-14T06:41:38","guid":{"rendered":"https:\/\/www.deditec.de\/?post_type=product&#038;p=25587934"},"modified":"2026-08-14T16:09:10","modified_gmt":"2026-08-14T14:09:10","slug":"modbus-tcp-analog-converter-module-2-channels-voltages-currents","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/ethernet\/modbus-tcp-analog-converter-module-2-channels-voltages-currents\/","title":{"rendered":"Modbus TCP analog * ethernet 16-bit A\/D converter with galvanic isolation &#8211; 2 channels"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25588069,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1583,245],"product_tag":[],"class_list":{"0":"post-25587934","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ai2","7":"einausgang-analoge-eingaenge","8":"schnittstelle-wifi-en","9":"schnittstelle-ethernet-en","10":"product_cat-ethernet","11":"product_cat-uc","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"purchasable","18":"product-type-simple"},"acf":{"sge_text":"<p>The UC-ETH-AD2-16ISO Modbus TCP analog converter module, featuring 2 galvanically isolated AD channels, acquires voltage and current signals with 16-bit resolution and converts them into digital measurement data. Values can be efficiently integrated into control and IoT systems via Ethernet and Modbus TCP. Ideal for connecting analog sensors in industrial automation or for monitoring energy and process data.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-ETH-AD2-16ISO with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supported protocols<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only TCP<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">HTTP, UDP, TCP, DHCP, Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Expands application possibilities in modern network and IoT infrastructures.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Ethernet Signal Isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not always galvanically isolated<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Galvanically isolated Ethernet interface for safe communication<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Protects connected systems from interference voltages and increases communication stability in industrial networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Current and voltage measurement<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some providers offer only voltage or only current<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Both signal types supported<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Enables the use of different sensor types without additional signal converters, thereby reducing hardware and wiring costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Resolution and accuracy<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 8\u201312 bit<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">High\u2011resolution 16\u2011bit for precise signal control<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Improves measurement accuracy and enables reliable evaluation of even small signal changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware filtering<\/strong><\/td>\n<td data-label=\"Market Comparison\">External filtering required<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Smoothing and averaging directly in the module; filters adjustable<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Reduces measurement noise and ensures more stable input values without external filter hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Protects connected systems from interference voltages and prevents interactions between measurement circuits and the power supply.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation between all channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often a common reference potential for all channels<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Galvanic isolation up to 500 V between all channels<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Enables measurements in environments with different reference potentials and prevents compensation currents between channels.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Remote access<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely possible<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Direct access via web and Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Allows for configuration and monitoring without physical presence, thereby supporting efficient maintenance processes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>High reliability thanks to M2M functionality<\/strong><\/td>\n<td data-label=\"Market Comparison\">A control PC is required<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Built-in M2M functionality enables autonomous operation without a PC<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Ensures continued operation even in the event of a control PC failure and increases system availability.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP analog modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-ETH-AD2-16ISO\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP analog modules\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Industrial sensor data acquisition:<br \/><\/strong>The analog inputs are suitable for precise acquisition of physical measurement variables such as pressure, temperature, or fill levels in industrial processes.<\/li>\n<li><strong>Laboratory and testing technology:<br \/><\/strong>The Modbus TCP analog module is ideally suited for experimental setups, data acquisition, and calibrations where high accuracy and reliability are essential.<\/li>\n<li><strong>Process data acquisition in production:<br \/><\/strong>Ideal for capturing continuous process values in manufacturing plants in order to make production workflows transparent and analyzable.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The Modbus TCP Analog Module features 2 analog inputs for measuring voltages and currents. It supports typical ranges such as 0\u20135 V, 0\u201310 V, 0\u201320 mA, and 4\u201320 mA. Data is transmitted via Ethernet or Modbus TCP. The device offers reliable signal conversion and is designed for industrial applications involving continuous data acquisition.<br \/>\n<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<li>Electrically isolated up to 1.5 kV<\/li>\n<\/ul>\n<h3>Wi-Fi interface:<\/h3>\n<ul>\n<li>Wi-Fi connection available<\/li>\n<li>WPS feature<\/li>\n<li>WPS Button<\/li>\n<\/ul>\n<h3>16-bit analog inputs:<\/h3>\n<ul>\n<li>Design: single-ended<\/li>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, 0\u201320 V, 0\u201340 V, \u00b15 V, \u00b110 V, \u00b120 V, \u00b140 V<\/li>\n<li>Current ranges: 0\u201320 mA, 4\u201320 mA, 0\u201324 mA<\/li>\n<li>Channel-to-channel isolation: max. 1 kV AC<\/li>\n<li>Electrical isolation for the power supply: max. 500 V<\/li>\n<li>A\/D converter conversion time: 4 \u00b5s<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-ETH-AD2-16ISO\">\n<h2>Product Description \u2013 Modbus TCP analog module<\/h2>\n<p>The DEDITEC Modbus TCP Analog Converter Module (2-channel) is a compact and powerful solution for the precise acquisition of analog measurement values \u200b\u200bin modern automation environments. Featuring two high-resolution 16-bit input channels for voltages and currents, the module enables the accurate capture of industrial sensor signals. Galvanic isolation ensures maximum operational safety and reliably protects connected systems against interference.<br \/>\nThanks to its integrated Ethernet interface, the device can be seamlessly integrated into existing networks. In addition to the DEDITEC protocol, the module fully supports the open Modbus TCP standard, enabling vendor-independent integration into PLC, SCADA, and IoT platforms. The intuitive web interface allows for configuration, diagnostics, and live monitoring directly within a browser\u2014without the need for additional software.<br \/>\nWith features such as configurable filters, 16-bit counters, watchdog mechanisms, and status LEDs, the module offers robust and reliable data acquisition for demanding applications. Its high accuracy and flexible communication capabilities make it ideal for distributed systems and Industry 4.0 architectures.<br \/>\nTypical areas of application include industrial process monitoring\u2014such as the acquisition of pressure, temperature, or flow signals\u2014as well as building automation, where analog sensors (e.g., level or environmental sensors) are integrated. The Modbus TCP analog module thus provides a future-proof, versatile, and precise solution for professional measurement tasks.<\/p>\n<h3>Flexible network communication via Ethernet &#038; Wi-Fi<\/h3>\n<p>The Ethernet and WiFi interfaces of the UC-ETH-AD2-16ISO enable flexible integration into existing networks\u2014both wired and wireless. Via Ethernet (10\/100 Mbps), the Modbus TCP analog module can be operated with a static or dynamic IP address and accessed directly through standard network protocols, while WiFi allows wireless integration, for example via WPS or manual configuration.<br \/>\nBoth communication methods support access through an integrated web interface as well as driver libraries and a mobile app, enabling simple parameterization and remote control. A key feature is the ability to make the Modbus TCP analog module accessible across the entire network and operate it via browser, software tools, or mobile devices.<br \/>\nOverall, Ethernet and WiFi provide scalable and location-independent communication within industrial applications.<\/p>\n<h3>Control &#038; software<\/h3>\n<p>For control purposes, the Modbus TCP analog module provides open protocols (TCP\/IP, Modbus TCP, and HTTP), enabling flexible integration into existing IT and automation environments. These protocols allow both traditional industrial applications and modern IoT scenarios to be implemented directly, without the need for additional gateways or proprietary interfaces.<br \/>\nIn addition, comprehensive API libraries are available for Python, C, C++, C#, Java, VB, and other programming languages, enabling the functions of the UC-ETH-AD2-16ISO to be seamlessly integrated into custom software solutions.<br \/>\nThe DELIB driver library, including CLI tools, also enables fast and straightforward commissioning as well as direct control via scripts or the command line, which is particularly useful for test, automation, and development environments. Furthermore, the I\/O Control App for mobile devices provides a convenient way to remotely control and monitor the system over the network, without requiring a traditional PC application.<br \/>\nOverall, this creates a highly flexible control architecture ranging from low-level integration to mobile operation.<\/p>\n<h3>Accurate and interference-resistant analog signal acquisition for industrial applications<\/h3>\n<p>The analog inputs of the UC-ETH-AD2-16ISO are designed for precise acquisition of voltage and current signals in industrial applications and provide two independently usable measurement channels. They support common input signals such as \u00b140 V as well as current signals in the ranges 0\u201320 mA, 4\u201320 mA, and 0\u201324 mA, enabling flexible adaptation to various sensors. The inputs on the Modbus TCP analog module are implemented with high impedance, ensuring that connected signal sources are only minimally loaded and stable measurement values are guaranteed. Due to the high resolution of the conversion, even small signal changes are reliably detected and accurately represented. In addition, galvanic isolation of the input stages provides safe decoupling between the measurement system and the signal source, effectively reducing interference and potential differences. As a result, the analog inputs are particularly well suited for demanding measurement and monitoring tasks in industrial environments.<\/p>\n<h3>Event Control \u2013 event-based automation<\/h3>\n<p>The Event Control function enables direct, event-driven processing of both digital and analog signals in the Modbus TCP analog module, without requiring cyclic polling by higher-level software. Digital signal transitions can immediately trigger internal actions, while analog signals can generate events based on defined thresholds, measurement ranges, or significant value changes. This allows responses to be implemented much faster and more resource-efficiently compared to traditional polling-based processing.<br \/>\nThe event logic can be flexibly configured, enabling both simple switching conditions and more complex dependencies between digital and analog signals. In addition, functions such as filtering, hysteresis, and threshold monitoring are available to ensure stable and reliable trigger conditions.<br \/>\nAs a result, Event Control is particularly well suited for automation applications where signals must be evaluated intelligently and processed immediately.<\/p>\n<h3>Robust industrial design with a well-engineered connection and mounting architecture<\/h3>\n<p>The Modbus TCP analog module is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-ETH-AD2-16ISO, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm\u00b2. In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.<\/p>\n<h3>User Benefits and Practical Application<\/h3>\n<p>The UC-ETH-AD2-16ISO offers a practical solution for industrial control and monitoring tasks. Its rugged, galvanically isolated electronics ensure reliable operation, while the documentation, drivers, and ICT diagnostic tool enable quick integration. Thanks to regular updates and direct developer support, the module remains operational over the long term and supports sustainable planning in professional environments.<br \/>\n<br \/>\n<\/section>\n","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW IS THE UC-ETH-AD2-16ISO CONTROLLED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The Modbus TCP analog modules can be controlled via the DEDITEC driver library (DELIB), Modbus TCP, or directly through the integrated web interface. In addition, the module supports encrypted Ethernet communication for secure data transmission.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHICH SOFTWARE AND PROGRAMMING LANGUAGES ARE SUPPORTED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The DELIB API supports numerous programming languages such as Python, C, C++, C#, VB, VB.NET, and Java. In addition, sample programs and a command-line interface solution for Windows and Linux are available. This allows the Modbus TCP analog modules to be quickly integrated into existing software projects.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">IS THERE A READY-MADE PROGRAMMING EXAMPLE FOR CONTROLLING THE MODULES USING MODBUS TCP?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, you will find a sample package containing a ready-made programming example for controlling our modules via Modbus TCP. In addition, the package includes examples for additional functions in all supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND DETAILED INFORMATION ABOUT THE HARDWARE OF THE UC-ETH-AD2-16ISO?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Detailed information about the hardware, such as pin assignment, power supply, technical specifications, and mechanical dimensions, can be found in the module manual. The manual is available directly on the product page under the \"Downloads and Manuals\" tab as well as in the download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT INTEGRATING THE API INTO MY OWN SOFTWARE PROJECTS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All information required to integrate the module into your own applications, including API descriptions and function references, can be found in the module manual as well as on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25587934","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25587934"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25588069"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25587934"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25587934"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25587934"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25587934"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}