{"id":25587919,"date":"2026-04-10T08:59:03","date_gmt":"2026-04-10T06:59:03","guid":{"rendered":"https:\/\/www.deditec.de\/?post_type=product&#038;p=25587919"},"modified":"2026-09-14T10:03:51","modified_gmt":"2026-09-14T08:03:51","slug":"modbus-tcp-output-voltages-16bit-4-8-channels","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/ethernet\/modbus-tcp-output-voltages-16bit-4-8-channels\/","title":{"rendered":"Modbus TCP voltage output * Ethernet 16-bit D\/A converter \u2013 4\/8 channels"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25588079,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[244,1578],"product_tag":[],"class_list":{"0":"post-25587919","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ao4","7":"einausgang-ao8","8":"einausgang-analoge-ausgaenge","9":"einausgang-_analog","10":"schnittstelle-ethernet","11":"schnittstelle-wifi","12":"product_cat-uc","13":"product_cat-ethernet","14":"pa_anzahl-kanaele-da-4_da_ch_de","15":"pa_anzahl-kanaele-da-8_da_ch_de","17":"first","18":"instock","19":"taxable","20":"shipping-taxable","21":"purchasable","22":"product-type-variable"},"acf":{"sge_text":"<p>The UC-ETH-DA4\/8_16 Modbus TCP D\/A module enables the output of precise voltages\u2014either via 4 or 8 channels with 16-bit resolution. Ideal for industrial applications such as controlling actuators and power supplies or simulating analog sensor signals. Thanks to Ethernet\/Wi-Fi, galvanic isolation, and M2M functionality, the module integrates seamlessly into automation and test systems.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-ETH-DA4\/8_16 with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supported protocols<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only TCP<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">HTTP, UDP, TCP, DHCP, Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Expands application possibilities in modern network and IoT infrastructures.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Ethernet Signal Isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not always galvanically isolated<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Galvanically isolated Ethernet interface for safe communication<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Protects connected systems from interference voltages and increases communication stability in industrial networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Protects connected systems from interference voltages and prevents interactions between measurement circuits and the power supply.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Analog voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Basic analog outputs, often only 0\u20135 V or 0\u201310 V<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Precise voltage output over 0\u20135 V, 0\u201310 V or \u00b110 V<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Enables precise control of various actuators and reduces the need for external signal converters.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Current and voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some providers offer only voltage or only current<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Both signal types supported<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Increases compatibility with various industrial and process signals and simplifies integration into existing systems.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Low output ripple<\/strong><\/td>\n<td data-label=\"Market Comparison\">Stronger ripple in OEM modules<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Low ripple and stable output signals<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Improves signal quality and ensures stable output values in sensitive control and regulation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Protects connected devices from interference voltages and prevents feedback between the output stage and the power supply.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Remote access<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely possible<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Direct access via web and Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Allows for configuration and monitoring without physical presence, thereby supporting efficient maintenance processes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA4\/8_16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP voltage output module<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-ETH-DA4\/8_16\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP voltage output module\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Automation technology:<br \/><\/strong>The D\/A outputs of the UC-ETH-DA4\/8_16 enable precise control of actuators and test benches in industrial applications.<\/li>\n<li><strong>Industrial process control:<br \/><\/strong>Analog signals can be flexibly output to actuators and control variables using the Modbus TCP voltage output module.<\/li>\n<li><strong>Research and development:<br \/><\/strong>Use in laboratories and test environments for scientific experiments and test setups.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The UC-ETH D\/A module offers 4 or 8 16-bit analog outputs and can output precise voltages via Modbus TCP. It supports ranges such as 0\u20135 V, 0\u201310 V, or \u00b110 V. The galvanically isolated Ethernet interface ensures interference-free operation, and the conversion rate is approximately 10\u201312 \u00b5s. Features such as event control, fail-safe, M2M, web interface, and WiFi enable flexible integration into automation and test systems.<br \/>\n<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<li>Electrically isolated up to 1.5 kV<\/li>\n<\/ul>\n<h3>Wi-Fi interface:<\/h3>\n<ul>\n<li>Wi-Fi connection available<\/li>\n<li>WPS feature<\/li>\n<li>WPS Button<\/li>\n<\/ul>\n<h3>Analog outputs:<\/h3>\n<ul>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V<\/li>\n<li>Isolation from power supply: max. 500 V AC<\/li>\n<li>D\/A converter conversion time: 10\u201312 \u00b5s<\/li>\n<li>Load resistance: \u2265 2 k\u03a9<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-ETH-DA4\/8_16\">\n<h2>Product Description \u2013 Modbus TCP voltage output module<\/h2>\n<p>The UC-ETH-DA4\/8_16 (4\/8 channels, 16-bit) from DEDITEC is a high-performance solution for applications requiring precise and reliable output of analog setpoints. Thanks to Ethernet-based Modbus TCP communication, the module can be seamlessly integrated into modern control and automation environments. The 4 or 8 analog outputs deliver 0\u201310 V signals with a fine 16-bit D\/A resolution, enabling precise control variables and finely graded signal curves.<br \/>\nElectrical isolation protects connected devices from interference and ensures stable signal quality, even in demanding industrial environments. The rugged hardware and mis-plug-proof WAGO connectors simplify installation and maintenance. The module can be flexibly configured and integrated into a wide variety of systems via the integrated web interface, the DELIB API, or Modbus TCP.<br \/>\nTypical applications include the control of valves, motors, or external controllers; building and plant automation; laboratory and test setups; and IoT-based control systems. Thanks to the combination of high precision, secure communication, and modular expandability, the module is ideal for applications where you need to reliably output Modbus TCP signals.<\/p>\n<h3>Flexible network communication via Ethernet &#038; Wi-Fi<\/h3>\n<p>The Ethernet and WiFi interfaces of the UC-ETH-DA4\/8_16 enable flexible integration into existing networks\u2014both wired and wireless. Via Ethernet (10\/100 Mbps), the Modbus TCP voltage output module can be operated with a static or dynamic IP address and accessed directly through standard network protocols, while WiFi allows wireless integration, for example via WPS or manual configuration.<br \/>\nBoth communication methods support access through an integrated web interface as well as driver libraries and a mobile app, enabling simple parameterization and remote control. A key feature is the ability to make the Modbus TCP voltage output module accessible across the entire network and operate it via browser, software tools, or mobile devices.<br \/>\nOverall, Ethernet and WiFi provide scalable and location-independent communication within industrial applications.<\/p>\n<h3>Control &#038; software<\/h3>\n<p>For control purposes, the Modbus TCP voltage output module provides open protocols (TCP\/IP, Modbus TCP, and HTTP), enabling flexible integration into existing IT and automation environments. These protocols allow both traditional industrial applications and modern IoT scenarios to be implemented directly, without the need for additional gateways or proprietary interfaces.<br \/>\nIn addition, comprehensive API libraries are available for Python, C, C++, C#, Java, VB, and other programming languages, enabling the functions of the UC-ETH-DA4\/8_16 to be seamlessly integrated into custom software solutions.<br \/>\nThe DELIB driver library, including CLI tools, also enables fast and straightforward commissioning as well as direct control via scripts or the command line, which is particularly useful for test, automation, and development environments. Furthermore, the I\/O Control App for mobile devices provides a convenient way to remotely control and monitor the system over the network, without requiring a traditional PC application.<br \/>\nOverall, this creates a highly flexible control architecture ranging from low-level integration to mobile operation.<\/p>\n<h3>High-precision analog outputs for industrial control and regulation applications<\/h3>\n<p>The UC-ETH-DA4\/8_16 provides, depending on the variant, 4 or 8 high-resolution analog outputs designed for demanding automation and control tasks. Each channel features 16-bit resolution, enabling particularly fine and precise signal generation. The outputs on the Modbus TCP voltage output module can be flexibly operated as voltage or current interfaces and support common ranges such as 0\u201310 V, \u00b110 V, and 0\/4\u201320 mA. This allows a wide variety of actuators such as control valves, drives, or process control systems to be precisely controlled.<br \/>\nThanks to the high conversion speed and stable signal quality, even dynamic control processes can be reliably implemented. In addition, galvanic isolation between output groups ensures robust and interference-resistant integration in industrial environments.<\/p>\n<h3>Robust industrial design with a well-engineered connection and mounting architecture<\/h3>\n<p>The Modbus TCP voltage output module is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-ETH-DA4\/8_16, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm\u00b2. In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.<\/p>\n<h3>Maintenance and Long-Term Planning<\/h3>\n<p>The UC-ETH-DA4\/8_16 supports users with a durable, industrial-grade architecture that enables predictable use over many years. The combination of robust drivers, comprehensive documentation, and the ICT diagnostic tool simplifies commissioning and maintenance. Electrical isolation and high-quality electronics ensure reliable operation, while support and continuous updates guarantee seamless integration into professional automation environments.<br \/>\n<br \/>\n<\/section>\n","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW CAN THE MODULES BE INTEGRATED INTO EXISTING SOFTWARE ARCHITECTURES?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Integration is performed using common interfaces such as TCP\/IP and Modbus TCP, as well as the DEDITEC DELIB driver library. This enables simple integration into existing software and control solutions.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE ICT TOOL BE USED WITHOUT ANY CUSTOM PROGRAMMING?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, the ICT-Tool enables direct access to the modules without the need for custom software development. This allows functions, interfaces, and I\/O states to be quickly tested and verified.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN PYTHON?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, we provide a comprehensive example package. It contains ready-made Python programming examples that allow you to quickly integrate our modules into your application.\nIn addition, you will also find examples for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT THE AVAILABLE INTERFACES AND FUNCTIONS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete description of the supported interfaces, communication options, and device functions can be found in the module manual. It is available at any time via the \"Downloads and Manuals\" tab on the respective product page as well as in the download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE ARE THE COMMANDS FOR CONTROLLING THE MODULE DOCUMENTED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The available commands for controlling and querying the module are described in detail in the module manual. Alternatively, the corresponding information can also be found on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25587919","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25587919"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25588079"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25587919"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25587919"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25587919"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25587919"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}