{"id":25587915,"date":"2026-04-10T08:59:00","date_gmt":"2026-04-10T06:59:00","guid":{"rendered":"https:\/\/www.deditec.de\/?post_type=product&#038;p=25587915"},"modified":"2026-08-14T16:09:18","modified_gmt":"2026-08-14T14:09:18","slug":"modbus-tcp-4-20ma-0-10v-da-module","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/ethernet\/modbus-tcp-4-20ma-0-10v-da-module\/","title":{"rendered":"Modbus TCP 4-20mA 0-10V * Ethernet 16-bit D\/A converter with galvanic isolation &#8211; 2 channels"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25588073,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[244,1578],"product_tag":[],"class_list":{"0":"post-25587915","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ao2","7":"einausgang-analoge-ausgaenge","8":"einausgang-_analog","9":"schnittstelle-ethernet","10":"schnittstelle-wifi","11":"product_cat-uc","12":"product_cat-ethernet","14":"first","15":"instock","16":"taxable","17":"shipping-taxable","18":"purchasable","19":"product-type-simple"},"acf":{"sge_text":"<p>The Modbus TCP \/ Ethernet D\/A module offers two galvanically isolated 16-bit analog outputs for 4\u201320 mA and 0\u201310 V. Communication takes place via 10\/100 Mbit\/s Ethernet using Modbus TCP, HTTP, and open TCP protocol. A fail-safe mode, web interface, API support, and rugged industrial connectors ensure reliable operation in automation, process control, and test systems.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-ETH-DA2-16ISO with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supported protocols<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only TCP<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">HTTP, UDP, TCP, DHCP, Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Expands application possibilities in modern network and IoT infrastructures.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Ethernet Signal Isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not always galvanically isolated<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Galvanically isolated Ethernet interface for safe communication<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Protects connected systems from interference voltages and increases communication stability in industrial networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Analog voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Basic analog outputs, often only 0\u20135 V or 0\u201310 V<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Precise voltage output over 0\u20135 V, 0\u201310 V or \u00b110 V<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Enables precise control of various actuators and reduces the need for external signal converters.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Current and voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some providers offer only voltage or only current<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Both signal types supported<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Increases compatibility with various industrial and process signals and simplifies integration into existing systems.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Low output ripple<\/strong><\/td>\n<td data-label=\"Market Comparison\">Stronger ripple in OEM modules<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Low ripple and stable output signals<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Improves signal quality and ensures stable output values in sensitive control and regulation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Protects connected devices from interference voltages and prevents feedback between the output stage and the power supply.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation between all channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often a common reference potential for all channels<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Galvanic isolation up to 500 V between all channels<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Enables operation in systems with different reference potentials and prevents compensation currents between channels.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Remote access<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely possible<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Direct access via web and Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Allows for configuration and monitoring without physical presence, thereby supporting efficient maintenance processes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-ETH-DA2-16ISO\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the Modbus TCP modules with 4-20 mA 0-10 V outputs\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Labor and testing technology:<br \/><\/strong>The Modbus TCP modules with 4-20 mA 0-10 V outputs is ideally suited for experimental setups, data acquisition, and calibrations where high precision and reliability are essential.<\/li>\n<li><strong>Test systems:<br \/><\/strong>Flexible control of individual channels supports simulations and repeatable test procedures.<\/li>\n<li><strong>Automated test benches:<br \/><\/strong>Precise D\/A signal control for test and validation environments.<\/li>\n<li><strong>Laboratory and measurement systems:<br \/><\/strong>For measurement and control tasks, the UC-ETH-DA2-16ISO provides high-resolution analog outputs.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The Modbus TCP \/ Ethernet D\/A module offers two galvanically isolated 16-bit analog outputs for 4\u201320 mA and 0\u201310 V. Communication takes place via 10\/100 Mbit\/s Ethernet using Modbus TCP, HTTP, and open TCP protocol. A fail-safe mode, web interface, API support, and rugged industrial connectors ensure reliable operation in automation, process control, and test systems.<br \/>\n<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<li>Electrically isolated up to 1.5 kV<\/li>\n<\/ul>\n<h3>Wi-Fi interface:<\/h3>\n<ul>\n<li>Wi-Fi connection available<\/li>\n<li>WPS feature<\/li>\n<li>WPS Button<\/li>\n<\/ul>\n<h3>Analog outputs:<\/h3>\n<ul>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V<\/li>\n<li>Current ranges: 0\u201320 mA, 4\u201320 mA, 0\u201324 mA<\/li>\n<li>Channel-to-channel isolation: max. 1 kV AC<\/li>\n<li>Isolation from power supply: max. 500 V AC<\/li>\n<li>Load resistance: \u2265 1 k\u03a9<\/li>\n<li>All D\/A channels are galvanically isolated from one another<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-ETH-DA2-16ISO\">\n<h2>Product Description \u2013 Modbus TCP module with 4-20 mA 0-10 V output<\/h2>\n<p>The Modbus TCP 4\u201320 mA\/0\u201310 V DA module from DEDITEC is a high-performance solution for the precise output of analog control signals in industrial applications. Via Modbus TCP, the module can be seamlessly integrated into modern Ethernet-based automation environments and enables the reliable control of actuators, control elements, or external control systems. The two analog outputs operate with 16-bit D\/A resolution, allowing for finely graded signal curves and precise setpoint specifications.<br \/>\nThanks to galvanic isolation, interference is minimized and connected devices are reliably protected. The flexible choice between 4\u201320 mA current output and 0\u201310 V voltage output makes the UC-ETH-DA2-16ISO universally applicable\u2014from industrial process plants to HVAC systems or laboratory setups. The robust hardware, mis-plug-protected WAGO connectors, and simple integration via the web interface or the DELIB API ensure quick commissioning and high operational reliability.<br \/>\nTypical applications for the Modbus TCP module with 4-20 mA 0-10 V output include the precise control of valves, pumps, or motors; building and plant automation; the output of setpoints to external controllers; and integration into IoT and Industry 4.0 systems. By combining high accuracy, secure communication, and versatile output ranges, the module offers a reliable platform for demanding control tasks.<\/p>\n<h3>Flexible network communication via Ethernet &#038; Wi-Fi<\/h3>\n<p>The Ethernet and WiFi interfaces of the UC-ETH-DA2-16ISO enable flexible integration into existing networks\u2014both wired and wireless. Via Ethernet (10\/100 Mbps), the Modbus TCP module with 4-20 mA 0-10 V output can be operated with a static or dynamic IP address and accessed directly through standard network protocols, while WiFi allows wireless integration, for example via WPS or manual configuration.<br \/>\nBoth communication methods support access through an integrated web interface as well as driver libraries and a mobile app, enabling simple parameterization and remote control. A key feature is the ability to make the Modbus TCP module with 4-20 mA 0-10 V output accessible across the entire network and operate it via browser, software tools, or mobile devices.<br \/>\nOverall, Ethernet and WiFi provide scalable and location-independent communication within industrial applications.<\/p>\n<h3>Control &#038; software<\/h3>\n<p>For control purposes, the Modbus TCP module with 4-20 mA 0-10 V output provides open protocols (TCP\/IP, Modbus TCP, and HTTP), enabling flexible integration into existing IT and automation environments. These protocols allow both traditional industrial applications and modern IoT scenarios to be implemented directly, without the need for additional gateways or proprietary interfaces.<br \/>\nIn addition, comprehensive API libraries are available for Python, C, C++, C#, Java, VB, and other programming languages, enabling the functions of the UC-ETH-DA2-16ISO to be seamlessly integrated into custom software solutions.<br \/>\nThe DELIB driver library, including CLI tools, also enables fast and straightforward commissioning as well as direct control via scripts or the command line, which is particularly useful for test, automation, and development environments. Furthermore, the I\/O Control App for mobile devices provides a convenient way to remotely control and monitor the system over the network, without requiring a traditional PC application.<br \/>\nOverall, this creates a highly flexible control architecture ranging from low-level integration to mobile operation.<\/p>\n<h3>Precise analog outputs for demanding control and regulation applications<\/h3>\n<p>The Modbus TCP module with 4-20 mA 0-10 V output features analog outputs with 16-bit resolution, enabling very fine and highly reproducible signal generation. Supported voltage ranges include 0\u20135 V, 0\u201310 V, as well as \u00b15 V and \u00b110 V, allowing flexible adaptation to different industrial actuators. The outputs offer high accuracy, low drift, and stable long-term performance, even during continuous operation.<br \/>\nWith short response times, the system is also well suited for dynamic control processes and rapid setpoint changes. Overall, the UC-ETH-DA2-16ISO is ideal for precise control and regulation tasks in demanding industrial environments.<\/p>\n<h3>Robust industrial design with a well-engineered connection and mounting architecture<\/h3>\n<p>The Modbus TCP module with 4-20 mA 0-10 V output is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-ETH-DA2-16ISO, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm\u00b2. In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.<\/p>\n<h3>Reliability and Industrial Quality<\/h3>\n<p>With the UC-ETH-DA2-16ISO, users get a reliable industrial module designed for continuous use in demanding automation projects. German engineering, galvanic isolation, and robust electronics ensure a high level of safety and stability. Clear documentation, stable drivers, and the ICT diagnostic tool make it easy to integrate and operate the module efficiently. Long-term updates and direct support round out this professional package.<br \/>\n<br \/>\n<\/section>\n","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW IS IT INTEGRATED INTO EXISTING SOFTWARE SYSTEMS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Integration is carried out via standardized communication methods such as TCP\/IP, Modbus TCP, or the DEDITEC DELIB driver library. This allows the modules to be easily integrated into existing control and automation environments.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW CAN THE MODULES BE CONFIGURED, TESTED, AND UPDATED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Configuration, diagnostics, and commissioning are conveniently performed using the DEDITEC ICT-Tool. It also allows functions to be tested and firmware updates to be carried out.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN VB?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section, we provide a sample package that contains ready-made VB code for controlling our modules.\nIn addition, the package includes implementation examples for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT COMMISSIONING THE UC-ETH-DA2-16ISO?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All important information regarding commissioning, wiring, configuration, and initial setup is described in the module manual. The document can be downloaded via the \"Downloads and Manuals\" section on the product page or through the central download area of the homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND EXAMPLES FOR SOFTWARE-BASED CONTROL OF THE MODULE?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Examples for controlling the module, as well as information about supported programming languages and libraries, can be found in the module documentation and on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25587915","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25587915"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25588073"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25587915"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25587915"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25587915"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25587915"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}