{"id":25587459,"date":"2026-03-12T13:12:42","date_gmt":"2026-03-12T12:12:42","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/?post_type=product&#038;p=25587459"},"modified":"2026-09-14T10:05:09","modified_gmt":"2026-09-14T08:05:09","slug":"canopen-interface-relay-output-module-16-relays","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/canopen\/canopen-interface-relay-output-module-16-relays\/","title":{"rendered":"CANopen interface relay output module * CANopen module with 16 digital outputs"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25584101,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[244,1580],"product_tag":[],"class_list":{"0":"post-25587459","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-ausgaenge","7":"einausgang-do16","8":"einausgang-_digital","9":"schnittstelle-canopen","10":"product_cat-uc","11":"product_cat-canopen","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"purchasable","18":"product-type-simple"},"acf":{"sge_text":"<p>The UC-CANopen-REL16 is a rugged relay output module featuring 16 high-performance 5-A relays that can be seamlessly integrated into industrial networks via a reliable CANopen interface. Electrical isolation and status LEDs for each channel ensure high operational reliability. Typical applications include the safe switching of industrial loads and decentralized machine control within a CANopen network.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-CANOPEN-REL16_5A with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-REL16_5A<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Relay output modules with CANopen interface<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-REL16_5A<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Relay output modules with CANopen interface<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status LEDs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly only general status LEDs<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Dedicated LED for each channel<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Enables quick status monitoring of each output and simplifies troubleshooting without the need for additional measuring equipment.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>High switching durability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Cheap relays with short lifespan<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Durable industrial relays for high switching cycles<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Extends the service life of the outputs and reduces maintenance and replacement intervals in applications with frequent switching.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Output type<\/strong><\/td>\n<td data-label=\"Market Comparison\">Standard outputs are often grouped together without specifying their relay characteristics in detail.<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Relay outputs with normally open (NO) contacts for standard industrial switching applications.<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Suitable for reliably switching external loads in typical industrial applications.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-REL16_5A<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Relay output modules with CANopen interface<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-REL16_5A<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Relay output modules with CANopen interface<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-REL16_5A<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Relay output modules with CANopen interface<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-REL16_5A<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Relay output modules with CANopen interface<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-REL16_5A<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Relay output modules with CANopen interface<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-REL16_5A<\/th >\n<th style=\"color: #555;\">Practical Benefits of the Relay output modules with CANopen interface<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-CANOPEN-REL16_5A\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the Relay output modules with CANopen interface\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Standardized automation networks (CiA 301\/401):<br \/><\/strong>The Relay output modules with CANopen interface is ideally suited for standards-based CANopen networks in industrial applications. Thanks to support for established CiA profiles, it can be seamlessly integrated into existing automation systems.<\/li>\n<li><strong>Decentralized machine control in a CANopen network:<br \/><\/strong>In CANopen structures, the UC-CANOPEN-REL16_5A can act as an intelligent network participant and support synchronized processes with other nodes in machines and systems.<\/li>\n<li><strong>System networking in industrial production:<br \/><\/strong>Perfect for structured networking of multiple machines or plant sections via CANopen. This enables scalable and modularly expandable production systems.<\/li>\n<li><strong>Synchronized real-time process communication:<br \/><\/strong>CANopen enables deterministic communication between multiple participants. This makes the Relay output module with CANopen interface suitable for time-critical control and synchronization tasks within the system network.<\/li>\n<li><strong>Diagnostics and network management in CANopen systems:<br \/><\/strong>By integrating into CANopen structures, the Relay output module with CANopen interface can also contribute to network diagnostics and monitoring of communication states within the overall system.<\/li>\n<li><strong>Inspection and test systems:<br \/><\/strong>Precise load control, repeatable test sequences, and safe switching logic in laboratory and test environments are supported by the Relay output module with CANopen interface.<\/li>\n<li><strong>Energy and load management:<br \/><\/strong>The Relay output module with CANopen interface enables targeted switching of loads and energy sources, for example in energy management systems, backup power solutions, or smart distribution networks.<\/li>\n<li><strong>Safety-critical control systems (fail-safe):<br \/><\/strong>The integrated fail-safe and timeout function of the UC-CANOPEN-REL16_5A ensures that defined states are automatically maintained in the event of communication failures\u2014especially important for safety-critical applications.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The module provides 16 relay outputs with high switching capacity and enables reliable, standards-compliant control in industrial networks via the CANopen interface. Electrical isolation enhances operational safety, while status indicators facilitate clear diagnostics. Typical applications include the safe switching of external loads and decentralized machine and plant control in automation environments.<br \/>\n<\/p>\n<h3>CANopen interface:<\/h3>\n<ul>\n<li>CANopen profiles according to CiA\u00ae specifications CiA 301, CiA 305, and CiA 401<\/li>\n<li>CAN 2.0A or CAN 2.0B<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<li>Configurable via DIP switches<\/li>\n<li>1 Mbit\/s, 800 Kbit\/s, 500 Kbit\/s, 250 Kbit\/s, 125 Kbit\/s, 100 Kbit\/s, 50 Kbit\/s, 20 Kbit\/s, 10 Kbit\/s, auto baud<\/li>\n<\/ul>\n<h3>Relay outputs 5 A:<\/h3>\n<ul>\n<li>Type: Normally Open (NO)<\/li>\n<li>Max. switching voltage: 48 V AC \/ DC<\/li>\n<li>Max. switching current: 5 A AC \/ DC<\/li>\n<li>Max. switching power: 150 W<\/li>\n<li>Timeout protection function (configurable via software)<\/li>\n<li>Status LED for each output<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-CANOPEN-REL16_5A\">\n<h2>Product Description \u2013 Relay output module with CANopen interface<\/h2>\n<p>The UC-CANopen-REL16 is a high-performance relay output module designed for industrial applications where reliable switching and high operational safety are critical. Via the integrated CANopen interface compliant with CiA 301\/305\/401, the Relay output module with CANopen interface can be seamlessly integrated into standardized automation networks and operated both as a stand-alone device and as part of a network of multiple modules. The 16 relay outputs are rated for up to 5 A and, thanks to their normally open (NO) function, provide a robust foundation for classic switching tasks in machine and plant control systems.<br \/>\nEach channel has its own status LED, which significantly simplifies diagnostics during operation. The galvanic isolation of the CAN interface up to 500 V increases immunity to interference and protects the system in demanding industrial environments. WAGO\u2019s screwless plug-in technology and the DIN-rail bus enable fast, mis-plug-proof installation and modular expandability.<br \/>\nTypical applications range from the safe switching of external loads in production facilities to decentralized machine control in CANopen networks, as well as inspection and test systems where reproducible switching operations and high reliability are required. Thus, the UC-CANopen-REL16 offers a durable, industrial-grade solution for modern automation projects.<\/p>\n<h3>Standardized CANopen communication for industrial automation networks<\/h3>\n<p>The CANopen interface of the UC-CANOPEN-REL16_5A is based on the internationally established CiA\u00ae specifications 301, 305, and 401 and enables reliable and standardized integration into industrial fieldbus environments. By supporting CAN 2.0A and CAN 2.0B, a high level of compatibility with a wide range of control and automation systems is ensured. Galvanic isolation of the bus connection provides robust signal transmission and reliably protects communication against interference in harsh industrial environments. Device addressing is conveniently carried out via integrated rotary coding switches, allowing the node ID to be set directly on the device at hardware level, which enables fast commissioning without additional configuration software. In addition, the baud rate can be flexibly adapted to the respective network, ensuring easy integration into existing system architectures. Furthermore, the interface on the module supports data rates of up to 1 Mbit\/s as well as features such as auto-baud detection to further simplify commissioning. This results in a powerful, stable, and standards-compliant communication solution that supports both fast installation and reliable operation in industrial environments.<\/p>\n<h3>Flexible control via CANopen for easy system integration<\/h3>\n<p>The control of the UC-CANOPEN-REL16_5A is fully based on the standardized CANopen protocol, enabling seamless integration into existing automation and control systems. By supporting the object-oriented communication model according to CiA 301, all functions are addressed and controlled via the Object Dictionary. Configuration is conveniently performed using standardized communication objects such as SDOs, while cyclic process data exchange via PDOs ensures fast and deterministic response in real-time operation.<br \/>\nIn addition, the Relay output module with CANopen interface supports typical CANopen Network Management (NMT) functions, enabling defined start, stop, and error states of the device within the network. Flexible assignment of node ID and baud rate simplifies adaptation to different network topologies and control environments. Thanks to this consistent implementation of the CANopen standard, the module can be efficiently integrated into existing automation architectures and centrally operated via the control system.<\/p>\n<h3>Powerful relay outputs for reliable industrial switching tasks<\/h3>\n<p>The UC-CANOPEN-REL16_5A provides digital outputs in the form of relay contacts designed for reliable switching of electrical loads in industrial environments. The outputs are rated for switching currents of up to 5 A, enabling the safe operation of typical industrial consumers. They also support switching voltages across common AC and DC applications up to the limits specified in the datasheet, offering flexible application possibilities.<br \/>\nGalvanic isolation between the control and load side ensures high operational safety and effective decoupling of sensitive electronics. Each output on the Relay output module with CANopen interface is equipped with a status LED that visually indicates the switching state directly on the device, significantly simplifying diagnostics. The relays are designed for a long service life and ensure reliable continuous operation even under frequent switching cycles.<\/p>\n<h3>Compact DIN rail design with modular system integration<\/h3>\n<p>Das Relay output module with CANopen interface ist f\u00fcr die Montage auf der DIN-Hutschiene ausgelegt und verf\u00fcgt \u00fcber ein kompaktes, industrietaugliches Geh\u00e4use, das auf den Einsatz in rauen Automatisierungsumgebungen optimiert ist. Die elektrischen Anschl\u00fcsse sind \u00fcber robuste, steckbare Klemmsysteme realisiert, die eine vibrationssichere Verdrahtung und eine schnelle Installation erm\u00f6glichen. Ein zentrales Merkmal ist der integrierte T-Bus, der als interner Systembus sowohl die Kommunikation als auch die Versorgungsspannung zwischen mehreren Modulen ohne zus\u00e4tzliche Verdrahtung durchreicht. Dadurch entsteht eine durchg\u00e4ngige Backplane-Struktur, bei der Module mechanisch auf der Hutschiene verbunden und elektrisch automatisch gekoppelt werden. Der T-Bus reduziert den Verkabelungsaufwand erheblich und sorgt gleichzeitig f\u00fcr eine saubere, EMV-optimierte Systemarchitektur mit geringem St\u00f6rpotenzial. \u00dcber die modulare Steckmechanik lassen sich weitere Teilnehmer einfach erg\u00e4nzen, ohne das bestehende System neu verdrahten zu m\u00fcssen. Die CANopen-Kommunikation des UC-CANOPEN-REL16_5A wird dabei nahtlos in diese T-Bus-Struktur eingebettet, wodurch eine skalierbare und systematisch aufgebaute Netzwerktopologie entsteht.<br \/>\nZus\u00e4tzlich verf\u00fcgt das Relay output module with CANopen interface \u00fcber integrierte Drehkodierschalter zur schnellen und einfachen Parametrierung direkt am Ger\u00e4t. \u00dcber diese lassen sich zentrale Einstellungen wie beispielsweise die Node-ID ohne Softwarezugriff konfigurieren. Dies erm\u00f6glicht eine besonders schnelle Inbetriebnahme sowie eine eindeutige Ger\u00e4teadressierung im Feld. Die Einstellung erfolgt dabei robust und manipulationssicher, auch im spannungslosen Zustand.<\/p>\n<h3>Integration and Operational Safety<\/h3>\n<p>The UC-CANOPEN-REL16_5A is a robust solution for industrial applications that require reliable processing of digital signals. Thanks to stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated into existing systems. The galvanically isolated electronics, \u201cMade in Germany,\u201d ensure high operational reliability, while regular updates and direct developer support enable long-term, stable use in professional environments.<br \/>\n<br \/>\n<\/section>\n","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW ARE ERROR CONDITIONS HANDLED IN A CANOPEN NETWORK?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The UC-CANOPEN-REL16_5A supports standardized CANopen network management (NMT) states as well as error handling mechanisms. In case of communication issues, it can enter defined safe states.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT COMMISSIONING THE UC-CANOPEN-REL16_5A?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All important information regarding commissioning, wiring, configuration, and initial setup is described in the module manual. The document can be downloaded via the \"Downloads and Manuals\" section on the product page or through the central download area of the homepage.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25587459","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25587459"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584101"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25587459"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25587459"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25587459"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25587459"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}