{"id":25585496,"date":"2019-11-21T08:28:53","date_gmt":"2019-11-21T07:28:53","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/ro-eth-usb-da\/"},"modified":"2026-08-14T16:01:06","modified_gmt":"2026-08-14T14:01:06","slug":"tcp-da-converter","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/usb-ethernet-http\/tcp-da-converter\/","title":{"rendered":"TCP D\/A converter * Ethernet\/USB analog output modules with 8\/16\/32\/64 D\/A outputs with 16 bit (Modbus TCP-compatible)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25586060,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1472,166],"product_tag":[],"class_list":{"0":"post-25585496","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ao8","7":"einausgang-ao16","8":"einausgang-analoge-ausgaenge","9":"einausgang-ao32","10":"einausgang-ao64","11":"schnittstelle-ethernet-en","12":"schnittstelle-usb-en","13":"product_cat-usb-ethernet-http","14":"product_cat-ro","15":"pa_anzahl-kanaele-da-8_da_ch_en","16":"pa_anzahl-kanaele-da-16_da_ch_en","17":"pa_anzahl-kanaele-da-32_da_ch_en","18":"pa_anzahl-kanaele-da-64_da_ch_en","19":"pa_schnittstellen-ethernet-schnittstelle_en","20":"pa_schnittstellen-usb-schnittstelle_en","22":"first","23":"instock","24":"taxable","25":"shipping-taxable","26":"purchasable","27":"product-type-variable"},"acf":{"sge_text":"<p>The RO-(ETH\/LC)\/(USB)-DA8-64 is a powerful TCP D\/A converter with 8, 16, 32, or 64 analog D\/A outputs and 16-bit resolution for industrial control and automation tasks. It supports both Ethernet 10\/100 Mbit with galvanic isolation, DHCP or static IP, as well as USB 2.0 plug &amp; play connectivity for easy integration without driver installation. Using open protocols including Modbus-TCP, HTTP, and TCP\/IP, signals can be reliably controlled via network, web interface, API libraries, or smartphone app. Flexible control via DELIB API, CLI, and web interface ensures fast automation processes. With a robust WAGO connector, encrypted communication, and fail-safe mode, this module provides ideal conditions for demanding measurement, control, and regulation tasks in mechanical engineering, IoT systems, and networked production environments.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of RO-(ETH\/LC)\/(USB)-DA8-64 with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Number of USB modules that can be used simultaneously<\/strong><\/td>\n<td data-label=\"Market Comparison\">1\u20134 modules, often without proper management<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Up to 16 modules per system<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Enables larger system configurations without additional distributors or expansion devices.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Ethernet Signal Isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not always galvanically isolated<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Galvanically isolated Ethernet interface for safe communication<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Protects connected systems from interference voltages and increases communication stability in industrial networks.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Analog voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Basic analog outputs, often only 0\u20135 V or 0\u201310 V<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Precise voltage output over 0\u20135 V, 0\u201310 V or \u00b110 V<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Enables precise control of various actuators and reduces the need for external signal converters.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Low output ripple<\/strong><\/td>\n<td data-label=\"Market Comparison\">Stronger ripple in OEM modules<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Low ripple and stable output signals<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Improves signal quality and ensures stable output values in sensitive control and regulation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Protects connected devices from interference voltages and prevents feedback between the output stage and the power supply.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Remote access<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely possible<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Direct access via web and Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Allows for configuration and monitoring without physical presence, thereby supporting efficient maintenance processes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support for many protocols<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one or two protocols offered<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">HTTP, UDP, TCP, DHCP, Modbus-TCP<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Increases compatibility with existing network infrastructures and enables flexible communication concepts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Modbus upgrade free of charge<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or not available at all<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Yes<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Expands communication capabilities without additional licensing costs or hardware changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series maturity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many products are new or frequently revised<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Series with 15+ years of history<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Offers a proven platform with stable firmware and mature hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-DA8-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the TCP D\/A converter modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-DA8-64\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the TCP D\/A converter modules\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Building Automation and Smart Home:<br \/><\/strong>Networked control of lights, blinds, heating, and other devices for comfortable, automated living.<\/li>\n<li><strong>IoT applications and connected systems:<br \/><\/strong>Real-time control over Ethernet, centralized monitoring, and easy integration into IoT platforms are realized via the RO-(ETH\/LC)\/(USB)-DA8-64.<\/li>\n<li><strong>Mobile control &#038; service applications:<br \/><\/strong>With a web interface and app access, systems can be conveniently configured, controlled, and maintained via smartphone or tablet\u2014even in the field.<\/li>\n<li><strong>Data logging and measurement data acquisition:<br \/><\/strong>Analog and digital signals are precisely acquired via USB using the RO-(ETH\/LC)\/(USB)-DA8-64 and transmitted to a system for analysis.<\/li>\n<li><strong>Laboratory and measurement technology:<br \/><\/strong>Stable 16-bit voltage outputs provide reliable signals for measurement and test systems.<\/li>\n<li><strong>Research and development:<br \/><\/strong>Use in laboratories and test environments for scientific experiments and test setups.<\/li>\n<\/ul>\n","produktbeschreibung_rest_api":"<section class=\"product-description product-description-RO-(ETH\/LC)\/(USB)-DA8-64\">\n<h2>Product Description \u2013 TCP D\/A converter module<\/h2>\n<p>The RO-(ETH\/LC)\/(USB)-DA8-64 provides multiple analog outputs with 16-bit resolution, enabling very finely graded and stable voltage or signal generation for industrial applications. Depending on the variant, voltage ranges of 0\u20135 V, 0\u201310 V, as well as \u00b15 V and \u00b110 V are available, allowing the TCP D\/A converter module to be flexibly adapted to a wide range of actuators such as valves, servo motors, or test bench components. High conversion accuracy and low temperature drift ensure precise and reproducible output signals even during continuous operation.<br \/>\nControl is fully register-based and can be implemented via various open communication and integration methods. These include Modbus TCP access, a proprietary TCP\/UDP protocol, and a comprehensive programming interface (DELIB API) that enables integration into C\/C++, C#, Java, or Python environments. In addition, HTTP-based functions as well as diagnostic and configuration options via a web interface support easy commissioning and maintenance.<br \/>\nThrough this combination of high-resolution analog technology and flexible, platform-independent control, the module is ideally suited for demanding industrial automation, test, and control applications.<\/p>\n<h3>Industrial Ethernet communication with TCP\/IP, Modbus TCP, and app integration<\/h3>\n<p>The Ethernet interface of the RO-(ETH\/LC)\/(USB)-DA8-64 enables direct integration into industrial networks via 10\/100 Mbps Ethernet with TCP\/IP communication. Data exchange is handled flexibly either through the open TCP\/IP protocol or via Modbus TCP, allowing vendor-independent integration into control and automation systems.<br \/>\nIn addition, the TCP D\/A converter module supports control via a dedicated app or mobile application as well as through the integrated web interface, enabling convenient operation and diagnostics without additional software. Network configuration can be set to either dynamic (DHCP) or static addressing and can be seamlessly integrated into existing IT or automation networks.<br \/>\nOverall, the Ethernet interface offers a versatile combination of classic industrial communication and modern, user-friendly remote access capabilities.<\/p>\n<h3>Simple direct connection via USB thanks to plug &#038; play<\/h3>\n<p>The USB interface of the RO-(ETH\/LC)\/(USB)-DA8-64 is primarily designed for a direct, local connection between the module and a control computer and is characterized by simple commissioning. Thanks to plug-and-play functionality and appropriate drivers, the device is automatically recognized, allowing immediate access to the TCP D\/A converter module via software tools.<br \/>\nTechnically, the interface is based on USB 2.0 with transfer rates of up to 480 Mbit\/s, providing a stable and fast data connection for configuration and control. It is often used for initial setup or for applications where no network infrastructure is available.<br \/>\nOverall, USB provides a straightforward and reliable interface for direct access.<\/p>\n<h3>Control &#038; software<\/h3>\n<p>For control purposes, the TCP D\/A converter module provides open protocols (TCP\/IP, Modbus TCP, and HTTP), enabling flexible integration into existing IT and automation environments. These protocols allow both traditional industrial applications and modern IoT scenarios to be implemented directly, without the need for additional gateways or proprietary interfaces.<br \/>\nIn addition, comprehensive API libraries are available for Python, C, C++, C#, Java, VB, and other programming languages, enabling the functions of the RO-(ETH\/LC)\/(USB)-DA8-64 to be seamlessly integrated into custom software solutions.<br \/>\nThe DELIB driver library, including CLI tools, also enables fast and straightforward commissioning as well as direct control via scripts or the command line, which is particularly useful for test, automation, and development environments. Furthermore, the I\/O Control App for mobile devices provides a convenient way to remotely control and monitor the system over the network, without requiring a traditional PC application.<br \/>\nOverall, this creates a highly flexible control architecture ranging from low-level integration to mobile operation.<\/p>\n<h3>High-resolution analog output signals for precise control applications<\/h3>\n<p>The analog outputs of the RO-(ETH\/LC)\/(USB)-DA8-64 operate with high 16-bit resolution, enabling very fine and highly reproducible signal generation. Common voltage ranges such as 0\u20135 V, 0\u201310 V, as well as \u00b15 V and \u00b110 V are supported, allowing flexible adaptation to different industrial actuators.<br \/>\nThe output stages are designed for stable long-term accuracy and ensure low drift even during continuous operation. Thanks to precise conversion, the TCP D\/A converter module is particularly well suited for control loops, test benches, and the actuation of sensitive control elements.<br \/>\nOverall, the module provides a reliable and high-resolution solution for demanding analog control tasks.<\/p>\n<h3>Form factor and connectors<\/h3>\n<p>The TCP D\/A converter module is designed for demanding industrial use and features a robust construction. Its housing is shock-resistant and vibration-proof, making it suitable for installation in control cabinets and on DIN rail mounting systems.<br \/>\nThe I\/Os of the RO-(ETH\/LC)\/(USB)-DA8-64 are wired via WAGO connectors, providing a secure, vibration-resistant connection. The module supports an operating temperature range from -20 \u00b0C to +60 \u00b0C and is designed for continuous operation under industrial conditions.<br \/>\nThanks to these features, it offers high reliability, a long service life, and easy maintenance, making it ideal for automation, mechanical engineering, and laboratory control applications.<\/p>\n<h3>Maintenance and Long-Term Planning<\/h3>\n<p>The RO-(ETH\/LC)\/(USB)-DA8-64 supports users with a durable, industrial-grade architecture that enables predictable use over many years. The combination of robust drivers, comprehensive documentation, and the ICT diagnostic tool simplifies commissioning and maintenance. Electrical isolation and high-quality electronics ensure reliable operation, while support and continuous updates guarantee seamless integration into professional automation environments.<br \/>\n<br \/>\n<\/section>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The RO-(ETH\/LC)\/(USB)-DA8-64 combines flexible interfaces (electrically isolated Ethernet or USB 2.0 Plug &#038; Play) with 8\u201364 analog 16-bit outputs and open protocols (TCP\/IP, Modbus-TCP, HTTP). It can be controlled via a web interface, DELIB API, CLI, or app.<br \/>\n<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<li>Electrically isolated up to 1.5 kV<\/li>\n<\/ul>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>Analog outputs:<\/h3>\n<ul>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V<\/li>\n<li>Isolation from power supply: max. 500 V AC<\/li>\n<li>D\/A converter conversion time: 10\u201312 \u00b5s<\/li>\n<li>Load resistance: \u2265 2 k\u03a9<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">THROUGH WHICH SOFTWARE INTERFACES IS THE RO-(ETH\/LC)\/(USB)-DA8-64 CONTROLLED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>USB models are integrated into software via the DEDITEC DELIB driver library. Ethernet models can, in addition to the DELIB library, also be accessed directly via TCP\/IP, Modbus TCP, or the web interface.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE MODULE BE USED WITHOUT AN ADDITIONAL PLC?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, thanks to the integrated event control, control tasks can be executed directly on the module. Using the ICT-Tool, \u201cif-then\u201d actions can be configured, enabling many applications to be implemented without an additional control PC or PLC.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN PYTHON?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, we provide a comprehensive example package. It contains ready-made Python programming examples that allow you to quickly integrate our modules into your application.\nIn addition, you will also find examples for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT COMMISSIONING THE RO-(ETH\/LC)\/(USB)-DA8-64?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All important information regarding commissioning, wiring, configuration, and initial setup is described in the module manual. The document can be downloaded via the \"Downloads and Manuals\" section on the product page or through the central download area of the homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT INTEGRATING THE API INTO MY OWN SOFTWARE PROJECTS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All information required to integrate the module into your own applications, including API descriptions and function references, can be found in the module manual as well as on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHAT IS A REMOTE I\/O MODULE IN PLC SYSTEMS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A remote I\/O module extends a PLC with decentralized inputs and outputs. Sensors and actuators are connected via a fieldbus system such as CAN instead of being wired directly to the PLC. The RO-(ETH\/LC)\/(USB)-DA8-64 performs this function via the CAN bus.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25585496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25585496"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25586060"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25585496"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25585496"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25585496"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25585496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}