{"id":25585470,"date":"2019-11-21T10:19:42","date_gmt":"2019-11-21T09:19:42","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/ro-eth-usb-di-do-mos\/"},"modified":"2026-10-06T15:54:49","modified_gmt":"2026-10-06T13:54:49","slug":"web-plc-io","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/usb-ethernet-http\/web-plc-io\/","title":{"rendered":"Web PLC I\/O * Ethernet\/USB module with 16\/32\/64 inputs and 16\/32\/64 outputs (optocoupler 3A)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25586076,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1472,166],"product_tag":[],"class_list":{"0":"post-25585470","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-eingaenge","7":"einausgang-digitale-ausgaenge","8":"einausgang-di16","9":"einausgang-di32","10":"einausgang-do16","11":"einausgang-di64","12":"einausgang-do32-en","13":"einausgang-do64-en","14":"schnittstelle-ethernet-en","15":"schnittstelle-usb-en","16":"product_cat-usb-ethernet-http","17":"product_cat-ro","18":"pa_anzahl-kanaele-di-do-16_di_do_ch_en","19":"pa_anzahl-kanaele-di-do-32_di_do_ch_en","20":"pa_anzahl-kanaele-di-do-64_di_do_ch_en","21":"pa_schnittstellen-ethernet-schnittstelle_en","22":"pa_schnittstellen-usb-schnittstelle_en","24":"first","25":"instock","26":"taxable","27":"shipping-taxable","28":"purchasable","29":"product-type-variable"},"acf":{"sge_text":"<p>The Web SPS I\/O module &#8211; RO-(ETH\/LC)\/(USB)-O16-64-M16-64 is available in versions with 16, 32, or 64 inputs and outputs, offering maximum flexibility for industrial control tasks. It can be operated via USB or Ethernet and supports modern protocols such as HTTP, TCP\/IP, Modbus-TCP, and APIs, allowing for quick and seamless integration into existing systems. With its scalable channels, it enables simultaneous control and monitoring of multiple processes, from small installations to complex automation solutions. As a Web SPS I\/O module, it impresses with reliable signal processing, easy installation, and versatile applications in industry.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of RO-(ETH\/LC)\/(USB)-O16-64-M16-64 with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Number of USB modules that can be used simultaneously<\/strong><\/td>\n<td data-label=\"Market Comparison\">1\u20134 modules, often without proper management<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Up to 16 modules per system<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Enables larger system configurations without additional distributors or expansion devices.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Ethernet Signal Isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not always galvanically isolated<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Galvanically isolated Ethernet interface for safe communication<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Protects connected systems from interference voltages and increases communication stability in industrial networks.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Counter function per channel<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only simple status queries or a global counting function.<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">16-bit counters per channel with up to 65,535 count cycles.<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Enables direct capture of pulses and events without additional hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Wide voltage range<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only positive voltage levels are allowed.<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Positive and negative voltages can be detected <\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Expands compatibility with various sensor signals and reduces the need for upstream signal conditioning.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Input filter<\/strong><\/td>\n<td data-label=\"Market Comparison\">Filter functions are often fixed or can only be configured to a limited extent.<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Programmable filter for input state changes and counter functions.<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Reduces bounce and improves the reliable detection of actual switching signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status display<\/strong><\/td>\n<td data-label=\"Market Comparison\">Channel statuses are often only visible to a limited extent or in aggregate.<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">LED status indicator per input and output channel for quick visual inspection.<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Speeds up diagnostics, commissioning, and troubleshooting directly at the module.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Detection of state changes<\/strong><\/td>\n<td data-label=\"Market Comparison\">Signal changes between two readout cycles are sometimes lost in standard modules.<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Internal flip-flops detect transitions from low to high and high to low between two readout operations.<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Improves event detection for short signal transitions and asynchronous state changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Signal isolation of the inputs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes without galvanic isolation or with reduced protection between the field and logic sides.<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Electrically isolated optocoupler inputs for safe signal operation<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Increases operational reliability when detecting external switching and sensor signals.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status LEDs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly only general status LEDs<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Dedicated LED for each channel<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Enables quick status monitoring of each output and simplifies troubleshooting without the need for additional measuring equipment.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>PWM function<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many MOSFET modules without PWM function<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">MOSFET channels can output PWM signals<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Supports applications with variable power control and enables finer regulation of actuators.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Fail-safe mode<\/strong><\/td>\n<td data-label=\"Market Comparison\">Only partially offered and not as flexible to configure<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">On connection loss, each output switches to a predefined state<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Prevents undefined switching states and increases operational safety in the event of a fault.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Remote access<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely possible<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Direct access via web and Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Allows for configuration and monitoring without physical presence, thereby supporting efficient maintenance processes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support for many protocols<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one or two protocols offered<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">HTTP, UDP, TCP, DHCP, Modbus-TCP<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Increases compatibility with existing network infrastructures and enables flexible communication concepts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Modbus upgrade free of charge<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or not available at all<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Yes<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Expands communication capabilities without additional licensing costs or hardware changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series maturity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many products are new or frequently revised<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Series with 15+ years of history<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Offers a proven platform with stable firmware and mature hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-(ETH\/LC)\/(USB)-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the web PLC I\/O modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the web PLC I\/O modules\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Building Automation and Smart Infrastructure:<br \/><\/strong>The web PLC I\/O module is suitable for controlling lighting, heating, air conditioning, and access systems, and enables centralized, energy-efficient building management thanks to network connectivity.<\/li>\n<li><strong>Process automation and remote control:<br \/><\/strong>Flexible integration into existing networks for remote maintenance, monitoring, and automated processes is easily possible with the web PLC I\/O module.<\/li>\n<li><strong>Remote monitoring and IoT projects:<br \/><\/strong>Real-time data acquisition and transmission to cloud systems, IoT gateways, or edge computing platforms. Perfect for distributed measurement points or remote monitoring of systems.<\/li>\n<li><strong>Decentralized I\/O expansion of existing systems:<br \/><\/strong>Scalable extension of control architectures through modular USB I\/O components directly at the machine environment.<\/li>\n<li><strong>Energy and load management:<br \/><\/strong>Monitoring and control of consumers in energy networks, load management for industrial or commercial applications.<\/li>\n<li><strong>Safety-critical control systems (fail-safe):<br \/><\/strong>The integrated fail-safe and timeout function of the RO-(ETH\/LC)\/(USB)-O16-64-M16-64 ensures that defined states are automatically maintained in the event of communication failures\u2014especially important for safety-critical applications.<\/li>\n<li><strong>Mechanical engineering:<br \/><\/strong>Through the RO-(ETH\/LC)\/(USB)-O16-64-M16-64, galvanically isolated inputs can be directly integrated into machine control systems, ensuring high immunity to interference.<\/li>\n<li><strong>Test and inspection facilities:<br \/><\/strong>Even fast signal changes in harsh industrial environments are reliably processed by the web PLC I\/O module.<\/li>\n<\/ul>\n","produktbeschreibung_rest_api":"<section class=\"product-description product-description-RO-(ETH\/LC)\/(USB)-O16-64-M16-64\">\n<h2>Product Description \u2013 web PLC I\/O module<\/h2>\n<p>The RO-(ETH\/LC)\/(USB)-O16-64-M16-64 is available in versions with 16, 32, or 64 inputs and outputs, providing a scalable solution for industrial automation tasks. It features robust MOS outputs, galvanically isolated inputs, and integrated flip-flop filters that ensure reliable signal processing. USB and Ethernet interfaces with HTTP, TCP\/IP, Modbus TCP, and API support enable fast and flexible integration into existing systems.<br \/>\nThanks to its clear channel structure, multiple processes can be monitored and controlled in parallel. The compact design, high switching speed, and built-in protection functions make the module durable and low-maintenance. This makes the web PLC I\/O module ideal for automation tasks, test benches, and industrial control systems where flexibility and easy integration are essential.<\/p>\n<h3>Industrial Ethernet communication with TCP\/IP, Modbus TCP, and app integration<\/h3>\n<p>The Ethernet interface of the RO-(ETH\/LC)\/(USB)-O16-64-M16-64 enables direct integration into industrial networks via 10\/100 Mbps Ethernet with TCP\/IP communication. Data exchange is handled flexibly either through the open TCP\/IP protocol or via Modbus TCP, allowing vendor-independent integration into control and automation systems.<br \/>\nIn addition, the web PLC I\/O module supports control via a dedicated app or mobile application as well as through the integrated web interface, enabling convenient operation and diagnostics without additional software. Network configuration can be set to either dynamic (DHCP) or static addressing and can be seamlessly integrated into existing IT or automation networks.<br \/>\nOverall, the Ethernet interface offers a versatile combination of classic industrial communication and modern, user-friendly remote access capabilities.<\/p>\n<h3>Simple direct connection via USB thanks to plug &#038; play<\/h3>\n<p>The USB interface of the RO-(ETH\/LC)\/(USB)-O16-64-M16-64 is primarily designed for a direct, local connection between the module and a control computer and is characterized by simple commissioning. Thanks to plug-and-play functionality and appropriate drivers, the device is automatically recognized, allowing immediate access to the web PLC I\/O module via software tools.<br \/>\nTechnically, the interface is based on USB 2.0 with transfer rates of up to 480 Mbit\/s, providing a stable and fast data connection for configuration and control. It is often used for initial setup or for applications where no network infrastructure is available.<br \/>\nOverall, USB provides a straightforward and reliable interface for direct access.<\/p>\n<h3>Control &#038; software<\/h3>\n<p>For control purposes, the web PLC I\/O module provides open protocols (TCP\/IP, Modbus TCP, and HTTP), enabling flexible integration into existing IT and automation environments. These protocols allow both traditional industrial applications and modern IoT scenarios to be implemented directly, without the need for additional gateways or proprietary interfaces.<br \/>\nIn addition, comprehensive API libraries are available for Python, C, C++, C#, Java, VB, and other programming languages, enabling the functions of the RO-(ETH\/LC)\/(USB)-O16-64-M16-64 to be seamlessly integrated into custom software solutions.<br \/>\nThe DELIB driver library, including CLI tools, also enables fast and straightforward commissioning as well as direct control via scripts or the command line, which is particularly useful for test, automation, and development environments. Furthermore, the I\/O Control App for mobile devices provides a convenient way to remotely control and monitor the system over the network, without requiring a traditional PC application.<br \/>\nOverall, this creates a highly flexible control architecture ranging from low-level integration to mobile operation.<\/p>\n<h3>Galvanically isolated digital inputs with filtering functions for reliable signal acquisition<\/h3>\n<p>The digital inputs on the RO-(ETH\/LC)\/(USB)-O16-64-M16-64 are implemented as opto-isolated switching inputs, ensuring reliable galvanic isolation between the field side and the internal electronics. They are designed for industrial 24 V AC\/DC signals and enable safe detection of switching states even in electrically noisy environments. The integrated filtering function suppresses short interference pulses, ensuring stable signal processing.<br \/>\nIn addition, the inputs feature event detection that reliably captures signal transitions and makes them available for further processing. In combination with counter and flip-flop functions, even fast pulses or state changes can be evaluated precisely. Each input of the RO-(ETH\/LC)\/(USB)-O16-64-M16-64 is also equipped with an individual status LED that visually indicates the current switching state directly on the device, enabling fast on-site diagnostics.<br \/>\nAs a result, the digital inputs are ideally suited for industrial automation tasks where robust and reliable signal acquisition is required.<\/p>\n<h3>High-performance MOS outputs<\/h3>\n<p>The MOS outputs of the RO-(ETH\/LC)\/(USB)-O16-64-M16-64 enable direct switching of relays, valves, or signal lamps. Each output features integrated short-circuit protection and overload protection, ensuring safe and long-term operation. The fast switching speed provides reliable real-time actuator control.<br \/>\nChannel-by-channel control allows flexible control scenarios, while galvanic isolation keeps interference away from the rest of the system. Thanks to robust MOS technology, the web PLC I\/O module is ideal for projects of any size.<\/p>\n<h3>Event Control \u2013 event-based automation<\/h3>\n<p>The Event Control function enables direct, event-driven processing of both digital and analog signals in the web PLC I\/O module, without requiring cyclic polling by higher-level software. Digital signal transitions can immediately trigger internal actions, while analog signals can generate events based on defined thresholds, measurement ranges, or significant value changes. This allows responses to be implemented much faster and more resource-efficiently compared to traditional polling-based processing.<br \/>\nThe event logic can be flexibly configured, enabling both simple switching conditions and more complex dependencies between digital and analog signals. In addition, functions such as filtering, hysteresis, and threshold monitoring are available to ensure stable and reliable trigger conditions.<br \/>\nAs a result, Event Control is particularly well suited for automation applications where signals must be evaluated intelligently and processed immediately.<\/p>\n<h3>Form factor and connectors<\/h3>\n<p>The web PLC I\/O module is designed for demanding industrial use and features a robust construction. Its housing is shock-resistant and vibration-proof, making it suitable for installation in control cabinets and on DIN rail mounting systems.<br \/>\nThe I\/Os of the RO-(ETH\/LC)\/(USB)-O16-64-M16-64 are wired via WAGO connectors, providing a secure, vibration-resistant connection. The module supports an operating temperature range from -20 \u00b0C to +60 \u00b0C and is designed for continuous operation under industrial conditions.<br \/>\nThanks to these features, it offers high reliability, a long service life, and easy maintenance, making it ideal for automation, mechanical engineering, and laboratory control applications.<\/p>\n<h3>Application and Benefits<\/h3>\n<p>The RO-(ETH\/LC)\/(USB)-O16-64-M16-64 offers a reliable and long-term solution for industrial automation tasks. With stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated and efficiently maintained. The robust electronics, developed in Germany and featuring galvanic isolation, ensure high operational reliability, while direct developer support and regular updates guarantee sustainable use in professional environments.<br \/>\n<br \/>\n<\/section>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The Web PLC I\/O module is a flexible and scalable solution for controlling and monitoring digital signals in industrial applications. It is available in versions with 16, 32, or 64 inputs and outputs and supports both USB and Ethernet interfaces for maximum integration.<br \/>\n<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<li>Electrically isolated up to 1.5 kV<\/li>\n<\/ul>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>MOSFET outputs 3 A:<\/h3>\n<ul>\n<li>Max. switching voltage: 36 V DC<\/li>\n<li>Min. switching voltage: 2.8 V DC<\/li>\n<li>Max. switching current: 3 A DC<\/li>\n<li>Max. switching power: 108 W DC<\/li>\n<li>Timeout protection function (configurable via software)<\/li>\n<li>Status LED for each output<\/li>\n<\/ul>\n<h3>Digital inputs:<\/h3>\n<ul>\n<li>Type: AC\/DC optocoupler<\/li>\n<li>Signal level: \u00b15 V to \u00b115 V or \u00b115 V to \u00b130 V<\/li>\n<li>16-bit counter per channel (up to 100 Hz)<\/li>\n<li>Detects a transition from low to high and from high to low (flip-flop)<\/li>\n<li>Status LED for each channel<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","faq_rest_api":"<div class=\"et_pb_row\">\r\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">THROUGH WHICH SOFTWARE INTERFACES IS THE RO-(ETH\/LC)\/(USB)-O16-64-M16-64 CONTROLLED?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>USB models are integrated into software via the DEDITEC DELIB driver library. Ethernet models can, in addition to the DELIB library, also be accessed directly via TCP\/IP, Modbus TCP, or the web interface.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">HOW CAN THE MODULES BE CONFIGURED, TESTED, AND UPDATED?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Configuration, diagnostics, and commissioning are conveniently performed using the DEDITEC ICT-Tool. It also allows functions to be tested and firmware updates to be carried out.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN PYTHON?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Yes. In the download section of our website, we provide a comprehensive example package. It contains ready-made Python programming examples that allow you to quickly integrate our modules into your application.\r\nIn addition, you will also find examples for other supported programming languages.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT COMMISSIONING THE RO-(ETH\/LC)\/(USB)-O16-64-M16-64?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>All important information regarding commissioning, wiring, configuration, and initial setup is described in the module manual. The document can be downloaded via the \"Downloads and Manuals\" section on the product page or through the central download area of the homepage.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">WHERE ARE THE COMMANDS FOR CONTROLLING THE MODULE DOCUMENTED?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>The available commands for controlling and querying the module are described in detail in the module manual. Alternatively, the corresponding information can also be found on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">WHAT IS A REMOTE I\/O MODULE IN PLC SYSTEMS?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>A remote I\/O module extends a PLC with decentralized inputs and outputs. Sensors and actuators are connected via a fieldbus system such as CAN instead of being wired directly to the PLC. The RO-(ETH\/LC)\/(USB)-O16-64-M16-64 performs this function via the CAN bus.<\/p>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\r\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25585470","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25585470"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25586076"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25585470"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25585470"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25585470"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25585470"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}