{"id":25585080,"date":"2024-07-01T15:35:36","date_gmt":"2024-07-01T13:35:36","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/can-io-box\/"},"modified":"2026-10-22T09:35:30","modified_gmt":"2026-10-22T07:35:30","slug":"can-io-box","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/can-box\/can-io-box\/","title":{"rendered":"CAN BOX Automotive I\/O Box analog &#038; digital &#8211; DEDITEC"},"content":{"rendered":"<section class=\"product-description product-description-CB-R8-M4-AD8_M\">\n<h2>Product Description \u2013 CAN Box I\/O Module<\/h2>\n<p>The DEDITEC CAN Box CB-R8-M4-AD8\/_M is a CAN I\/O module for vehicles, special-purpose vehicles, mobile machinery and industrial CAN networks. The CAN I\/O box combines a CAN 2.0A\/B interface with an additional USB interface for configuration, 8 changeover relays, 4 MOSFET outputs and 8 analog inputs. This makes the CAN Box suitable for decentralized switching, measurement and control tasks where electrical loads must be switched, analog sensor signals acquired and CAN frames automatically processed.<\/p>\n<h3>System Role in CAN-Based Vehicle and Machine Architectures<\/h3>\n<p>The CB-R8-M4-AD8\/_M acts as a decentralized CAN I\/O module between sensors, actuators and the CAN bus. It can acquire analog measurement signals, switch digital outputs and automatically send or receive CAN messages. This makes the module suitable for applications where not every signal processing task should run through a central PLC or a permanently connected control PC. This system role is particularly relevant in special-purpose vehicles, mobile work machines, commercial vehicle superstructures, test benches and industrial CAN installations.<\/p>\n<h3>8 Changeover Relays, 4 MOSFET Outputs and 8 Analog Inputs in One CAN Module<\/h3>\n<p>The combination of 8 changeover relays, 4 MOSFET outputs and 8 analog inputs reduces the need for separate individual modules. The relay outputs are implemented as changeover contacts and are suitable for classic switching tasks, releases, signaling circuits or external loads. The MOSFET outputs are designed for fast and robust DC switching tasks and support up to 36 V DC and up to 9 A DC when only one output is used. The 8 analog inputs acquire voltage signals in the range of 0\u201318 V with 12\u2011bit resolution and can capture measurement signals from sensors or transducers.<\/p>\n<h3>Reliable Signal Processing with Galvanic CAN Isolation, A\/D Filter and Fail-Safe<\/h3>\n<p>For use in vehicles, machines and distributed CAN networks, robust signal processing is essential. The CAN interface operates according to ISO 11898, supports bit rates from 10 kbit\/s to 1 Mbit\/s and is galvanically isolated up to 500 V rms. Analog input signals can be smoothed using the software-based A\/D filter to reduce interference in measurement signals. Additionally, the module supports fail-safe or timeout functions, allowing digital outputs to be placed into defined states in the event of communication failure.<\/p>\n<h3>Event Control for Control Without a PLC<\/h3>\n<p>With Event Control, simple control tasks can be stored directly in the module. Events and actions are configured via the ICT tool and executed according to the if\u2011then principle. This allows the CAN I\/O module to independently process certain states, thresholds or communication events and derive actions from them. In practice, this enables simple automation logic without an additional PLC and without a permanently connected control PC \u2014 for example, for switching functions, limit value reactions or event-driven transmission of CAN frames.<\/p>\n<h3>Auto TX\/RX and M2M-CAN for Automatic CAN Communication<\/h3>\n<p>Using Auto TX\/RX mode, the CB-R8-M4-AD8\/_M can automatically send and receive CAN frames. Input values can be transmitted cyclically or event\u2011driven to other CAN participants; received CAN data can in turn control outputs on the module. Additionally, M2M\u2011CAN supports direct communication between DEDITEC modules with CAN interfaces. This allows measurement values, switching states or digital\/analog signals to be exchanged directly between modules without requiring continuous intervention from user software.<\/p>\n<h3>Typical Applications<\/h3>\n<ul>\n<li>Custom modifications in special-purpose vehicle construction<\/li>\n<li>Mobile machinery, harvesting and agricultural machines, and construction vehicles<\/li>\n<li>Emergency vehicles, fire trucks and commercial vehicle superstructures<\/li>\n<li>Motorhomes and mobile energy or control systems<\/li>\n<li>Test benches, test systems and CAN-based data acquisition<\/li>\n<li>Decentralized switching tasks via CAN with relay and MOSFET outputs<\/li>\n<li>Acquisition of analog sensor signals via 0\u201318 V analog inputs<\/li>\n<li>Simple control logic without PLC using Event Control and Auto TX\/RX<\/li>\n<\/ul>\n<h3>Integration, Configuration and Operation<\/h3>\n<p>CAN configuration is performed via the ICT tool and the additional USB interface. CAN parameters such as baud rate, addressing, TX\/RX behavior and other communication parameters can be set. Various CAN bit rates from 10 kbit\/s to 1 Mbit\/s are available for operation. Product versions cover 24\u2011V and 48\u2011V supply ranges; variants with or without mounting rail allow adaptation to different installation environments. This enables the CB-R8-M4-AD8\/_M to be integrated into both mobile applications and stationary CAN and automation environments.<\/p>\n<h3>Made in Germany<\/h3>\n<p>DEDITEC develops and manufactures its I\/O, control and measurement modules in Germany. For the CB-R8-M4-AD8\/_M, Made in Germany means product\u2011focused development, transparent technical documentation and a design intended for long\u2011term use in vehicle technology, mechanical engineering, test bench construction and industrial automation.<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<section class=\"ddt-technical-data\">\n<h2>Technical data<\/h2>\n<p>The DEDITEC CAN Box CB-R8-M4-AD8\/_M is a CAN I\/O module for vehicles, special-purpose vehicles, mobile machinery, and industrial CAN networks. It combines CAN 2.0A\/2.0B, USB configuration, relay outputs, MOSFET outputs, and analog inputs in a compact module for decentralized switching, measurement, and control tasks.<\/p>\n<p>&nbsp;<\/p>\n<h3>At a glance<\/h3>\n<ul>\n<li>CAN Box \/ CAN I\/O module for vehicles, special-purpose vehicles, mobile machinery, and industrial CAN networks<\/li>\n<li>CAN 2.0A \/ CAN 2.0B according to ISO 11898<\/li>\n<li>Open CAN protocol with bit rates from 10 kbit\/s to 1 Mbit\/s<\/li>\n<li>Galvanically isolated CAN interface up to 500 V rms<\/li>\n<li>USB Type B interface for configuration via PC or notebook<\/li>\n<li>8 changeover relays for digital switching tasks<\/li>\n<li>4 P-channel MOSFET outputs for DC switching tasks<\/li>\n<li>8 analog inputs with 12-bit resolution and a 0\u201318 V voltage range<\/li>\n<li>Auto TX\/RX for automatic transmission and reception of CAN packets<\/li>\n<li>M2M CAN, Event Control, A\/D filter, and fail-safe\/timeout function<\/li>\n<li>24 V and 48 V variants, optionally with mounting rail<\/li>\n<\/ul>\n<h3>CAN and USB connectivity<\/h3>\n<ul>\n<li>CAN 2.0A \/ CAN 2.0B according to ISO 11898<\/li>\n<li>Open CAN protocol for integration into existing CAN networks<\/li>\n<li>Bit rates: 1 Mbit\/s, 500 kbit\/s, 250 kbit\/s, 125 kbit\/s, 100 kbit\/s, 50 kbit\/s, 20 kbit\/s, and 10 kbit\/s<\/li>\n<li>Galvanic isolation of the CAN interface up to 500 V rms<\/li>\n<li>USB Type B for configuration, commissioning, and adjustment of CAN parameters via PC or notebook<\/li>\n<\/ul>\n<h3>Digital outputs for relay and MOSFET switching tasks<\/h3>\n<ul>\n<li>8 relay outputs as changeover contacts \/ SPDT<\/li>\n<li>Relay type: OMRON G5LE-1<\/li>\n<li>Relay: max. switching voltage 48 V AC\/DC<\/li>\n<li>Relay: max. switching current 9 A DC with a maximum of one connected output per connector, otherwise 6 A DC<\/li>\n<li>Relay: max. switching power 350 W per output<\/li>\n<li>4 P-channel MOSFET outputs for DC switching tasks<\/li>\n<li>MOSFET up to 1 A: 5 V &#8211; 16 V switching voltage<\/li>\n<li>MOSFET up to 9 A: 2.8 V &#8211; 36 V switching voltage<\/li>\n<li>MOSFET: max. 9 A DC with a maximum of one connected output, otherwise 6 A DC<\/li>\n<li>MOSFET: max. switching power 324 W<\/li>\n<\/ul>\n<h3>Analog inputs and measurement signal processing<\/h3>\n<ul>\n<li>8 analog inputs<\/li>\n<li>12-bit resolution per channel<\/li>\n<li>Single-ended inputs<\/li>\n<li>Voltage range: 0\u201318 V<\/li>\n<li>Suitable for acquiring analog sensor signals, transducer signals, and voltage signals<\/li>\n<li>Software-based A\/D filter for smoothing and optimizing analog measurement signals<\/li>\n<\/ul>\n<h3>Automatic CAN communication and control logic<\/h3>\n<ul>\n<li>Auto TX\/RX for automatic transmission and reception of CAN packets<\/li>\n<li>M2M CAN for direct communication between DEDITEC modules with CAN interface<\/li>\n<li>Event Control for simple if-then control tasks directly within the module<\/li>\n<li>Fail-safe\/timeout function for defined output states in the event of a communication failure<\/li>\n<\/ul>\n<h3>Power supply and variants<\/h3>\n<ul>\n<li>24 V version: +7 V to +24 V DC<\/li>\n<li>48 V version: +10 V to +48 V DC<\/li>\n<li>A\/D range for all variants: 0\u201318 V<\/li>\n<li>Variants with \u201c_M\u201d: with mounting rail<\/li>\n<li>48 V variants: with Power-Off mode<\/li>\n<\/ul>\n<\/section>\n","protected":false},"featured_media":25584832,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[246],"product_tag":[],"class_list":{"0":"post-25585080","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-ausgaenge","7":"einausgang-do8","8":"einausgang-ai8","9":"einausgang-analoge-eingaenge","10":"einausgang-_digital","11":"einausgang-_analog","12":"schnittstelle-can","13":"schnittstelle-usb","14":"product_cat-can-box","15":"pa_ausgaenge-do-art-mosfet-ausgaenge-1a_de","16":"pa_ausgaenge-do-art-mosfet-ausgaenge-2a_de","17":"pa_betriebsspannung-48v_de","18":"pa_betriebsspannung-24v_de","19":"pa_montageschiene-ohne-montageschiene_de","20":"pa_montageschiene-mit-montageschiene_de","22":"first","23":"instock","24":"taxable","25":"shipping-taxable","26":"purchasable","27":"product-type-variable"},"acf":{"produktvergleich_rest_api":"","zusatztext_rest_api":"","produktbeschreibung_rest_api":"","technische_daten_rest_api":"","produktvergleich":"<h2>Comparison: CAN Box and CAN I\/O Module for Vehicles, Mobile Machines and Industrial CAN Networks<\/h2>\n<p>The following comparison classifies the DEDITEC CAN Box CB-R8-M4-AD8\/_M technically: as a CAN I\/O module with CAN 2.0A\/B, USB configuration, 8 changeover relays, 4 MOSFET outputs, 8 analog inputs, Auto TX\/RX, Event Control and fail-safe functionality. The table supports quick evaluation for vehicle technology, special-purpose vehicle construction, mobile machinery, test benches and industrial CAN applications.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Product Type, CAN Communication and Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>CB-R8-M4-AD8\/_M<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td><strong>Product Type<\/strong><\/td>\n<td>Many CAN I\/O modules are specialized either for digital I\/O functions or for individual signal types.<\/td>\n<td>DEDITEC CAN Box and CAN I\/O module with relay outputs, MOSFET outputs and analog inputs in one device.<\/td>\n<td>Switching, measuring and simple control logic can be combined in one compact CAN remote I\/O module.<\/td>\n<\/tr>\n<tr>\n<td><strong>CAN Interface<\/strong><\/td>\n<td>Supported CAN versions, bit rates and protocol access vary significantly across module classes.<\/td>\n<td>CAN 2.0A \/ CAN 2.0B according to ISO 11898 with bit rates from 10 kbit\/s to 1 Mbit\/s.<\/td>\n<td>Simplifies integration into existing CAN networks of vehicles, mobile machines, test benches and industrial systems.<\/td>\n<\/tr>\n<tr>\n<td><strong>Open CAN Protocol<\/strong><\/td>\n<td>Some modules rely on highly vendor-specific communication models or limited telegram structures.<\/td>\n<td>Open CAN protocol for integration into custom CAN architectures.<\/td>\n<td>Suitable for custom telegrams, proprietary control software, gateways and PC-based test systems.<\/td>\n<\/tr>\n<tr>\n<td><strong>Configuration<\/strong><\/td>\n<td>In many CAN modules, parameterization is performed exclusively via bus commands or separate vendor tools.<\/td>\n<td>USB Type B interface for configuration, commissioning and adjustment of CAN parameters via PC or notebook.<\/td>\n<td>Baud rate, addressing, Auto TX\/RX behavior and Event Control can be tested and adjusted before integration.<\/td>\n<\/tr>\n<tr>\n<td><strong>Galvanic CAN Isolation<\/strong><\/td>\n<td>Galvanic isolation of the CAN interface is not present in all compact CAN I\/O modules.<\/td>\n<td>Galvanically isolated CAN interface up to 500 V rms.<\/td>\n<td>Supports operation in distributed systems with different potentials and increases robustness of CAN communication.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Relays, MOSFET Outputs and Analog Inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>CB-R8-M4-AD8\/_M<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td><strong>I\/O Combination<\/strong><\/td>\n<td>Relays, MOSFET outputs and analog input signals often require multiple separate modules.<\/td>\n<td>8 changeover relays, 4 P-channel MOSFET outputs and 8 analog inputs.<\/td>\n<td>Reduces module count, wiring effort and space requirements for mixed switching and measurement tasks.<\/td>\n<\/tr>\n<tr>\n<td><strong>Relay Outputs<\/strong><\/td>\n<td>Compact CAN relay modules differ mainly in contact type, switching current and documented design.<\/td>\n<td>8 relay outputs as changeover contacts \/ SPDT, max. 48 V AC\/DC and up to 9 A DC with only one connected output per connector, otherwise 6 A DC.<\/td>\n<td>Suitable for releases, signaling circuits, indicator lights, relays, valves and other switching tasks in vehicle and machine environments.<\/td>\n<\/tr>\n<tr>\n<td><strong>MOSFET Outputs<\/strong><\/td>\n<td>Not every CAN relay module additionally offers electronic DC switching outputs.<\/td>\n<td>4 P-channel MOSFET outputs, from 2026 according to manual 2.8\u201336 V DC and up to 9 A DC with only one connected output, otherwise 6 A DC.<\/td>\n<td>Extends the module with electronic DC switching functions for mobile and industrial applications.<\/td>\n<\/tr>\n<tr>\n<td><strong>Analog Inputs<\/strong><\/td>\n<td>Many compact CAN switching modules do not acquire analog signals or require separate A\/D modules.<\/td>\n<td>8 analog inputs, single-ended, 12-bit resolution, voltage range 0\u201318 V.<\/td>\n<td>Analog sensor signals, transducers or voltage signals can be integrated directly into CAN-based measurement and control systems.<\/td>\n<\/tr>\n<tr>\n<td><strong>A\/D Filter<\/strong><\/td>\n<td>Signal smoothing is often implemented only in higher-level software.<\/td>\n<td>Software-based A\/D filter with averaging for smoothing analog measurement signals.<\/td>\n<td>Interference-prone analog signals can be evaluated more reliably before being processed further in the CAN system.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Automatic CAN Communication and Control Without PLC<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>CB-R8-M4-AD8\/_M<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td><strong>Auto TX\/RX<\/strong><\/td>\n<td>In simple CAN I\/O modules, sending and receiving CAN frames often must be controlled entirely externally.<\/td>\n<td>Auto TX\/RX mode for automatic sending, receiving and processing of CAN frames.<\/td>\n<td>Reduces programming effort and enables cyclic or event-driven CAN communication without permanent PC connection.<\/td>\n<\/tr>\n<tr>\n<td><strong>Event Control<\/strong><\/td>\n<td>Simple control logic is often implemented in a PLC, control PC or separate software.<\/td>\n<td>Event Control with configurable events and actions directly in module memory.<\/td>\n<td>Enables if-then logic, switching reactions and threshold functions directly in the module.<\/td>\n<\/tr>\n<tr>\n<td><strong>Control Without PLC<\/strong><\/td>\n<td>Simple automation tasks often require additional control hardware.<\/td>\n<td>Stand-alone functions via Auto TX\/RX, Event Control and stored module parameters.<\/td>\n<td>Suitable for decentralized CAN mini-PLC tasks where no full PLC architecture is required.<\/td>\n<\/tr>\n<tr>\n<td><strong>M2M-CAN<\/strong><\/td>\n<td>Module-to-module communication is often coordinated via a central application or controller.<\/td>\n<td>M2M-CAN for direct communication between DEDITEC modules with CAN interface.<\/td>\n<td>Measurement values, switching states and signals can be exchanged between modules without continuous intervention from user software.<\/td>\n<\/tr>\n<tr>\n<td><strong>Fail-Safe \/ Timeout<\/strong><\/td>\n<td>Timeout or fail-safe functions are not integrated in every CAN I\/O product class.<\/td>\n<td>Fail-safe and timeout functions with definable output states in case of communication failure.<\/td>\n<td>Helps avoid undefined output states during communication problems.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Variants, Application Environment and Project Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>CB-R8-M4-AD8\/_M<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td><strong>Power Supply Variants<\/strong><\/td>\n<td>Many I\/O modules are designed for a fixed supply voltage range.<\/td>\n<td>24 V variants with +7 V to +24 V DC and 48 V variants with +10 V to +48 V DC.<\/td>\n<td>Supports use in different vehicle, machine and industrial environments.<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting Variants<\/strong><\/td>\n<td>Depending on module design, additional brackets or adapters may be required.<\/td>\n<td>Variants available with or without mounting rail.<\/td>\n<td>Simplifies adaptation to different installation situations, such as vehicle superstructures, control cabinets or test benches.<\/td>\n<\/tr>\n<tr>\n<td><strong>Use in Vehicles and Mobile Machines<\/strong><\/td>\n<td>Many standard I\/O modules are primarily designed for stationary automation environments.<\/td>\n<td>CAN I\/O module for vehicles, special-purpose vehicles, mobile machines and industrial CAN networks.<\/td>\n<td>Suitable for decentralized switching, measurement and control tasks in mobile and stationary CAN architectures.<\/td>\n<\/tr>\n<tr>\n<td><strong>Software Integration<\/strong><\/td>\n<td>Software integration in CAN modules often depends on vendor-specific tools and available libraries.<\/td>\n<td>Configuration via ICT tool; integration via documented CAN functions and DEDITEC software environment.<\/td>\n<td>Supports commissioning, diagnostics, testing and integration into custom control, test bench or measurement software.<\/td>\n<\/tr>\n<tr>\n<td><strong>Manufacturer Quality<\/strong><\/td>\n<td>Documentation, support, product maintenance and manufacturing location are important evaluation criteria for technical I\/O modules.<\/td>\n<td>DEDITEC CAN I\/O box, developed and manufactured in Germany.<\/td>\n<td>Supports traceable technical documentation, project-oriented integration and long-term use in B2B applications.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext":"<section class=\"ddt-use-cases\">\n<h2>Application Areas<\/h2>\n<p>The DEDITEC CAN Box CB-R8-M4-AD8\/_M is suitable for CAN-based applications where switching tasks, analog signal acquisition and simple control logic need to be implemented decentrally in a vehicle, mobile machine or industrial CAN network. With its combination of CAN 2.0A\/B, 8 changeover relays, 4 MOSFET outputs, 8 analog inputs, Auto TX\/RX and Event Control, the CAN Box can be used as a compact CAN remote I\/O module for switching, measuring and event-driven signal processing.<\/p>\n<p>&nbsp;<\/p>\n<h3>Suitable for<\/h3>\n<ul>\n<li>Special-purpose vehicle construction and custom vehicle modifications<\/li>\n<li>Mobile work machines, harvesting and agricultural machinery<\/li>\n<li>Construction vehicles, commercial vehicle superstructures and technical vehicle systems<\/li>\n<li>Fire trucks, emergency vehicles and mobile supply or control units<\/li>\n<li>Motorhomes, special-purpose installations and mobile energy or control systems<\/li>\n<li>Test benches, test systems and CAN-based data acquisition<\/li>\n<li>Mechanical engineering, special-purpose machinery and decentralized industrial automation<\/li>\n<li>Existing CAN networks requiring additional relay, MOSFET or analog functions<\/li>\n<\/ul>\n<h3>Typical Applications<\/h3>\n<ul>\n<li>Switching consumers, releases, signal lights, relays, valves or signaling circuits via CAN<\/li>\n<li>Driving DC loads via MOSFET outputs in mobile and industrial applications<\/li>\n<li>Acquisition of analog sensor signals, transducers or voltage signals in the 0\u201318 V range<\/li>\n<li>Forwarding measurement values, switching states and status information to CAN controllers<\/li>\n<li>Extending existing vehicle or machine architectures with decentralized I\/O functions<\/li>\n<li>Automatic sending and receiving of CAN frames via Auto TX\/RX<\/li>\n<li>Direct module-to-module communication via M2M-CAN<\/li>\n<li>Implementing simple control logic without a permanently connected control PC<\/li>\n<\/ul>\n<h3>Typical Signal and Control Tasks<\/h3>\n<ul>\n<li>Decentralized processing of analog measurement signals and digital switching states<\/li>\n<li>Event-driven switching reactions via Event Control<\/li>\n<li>Threshold-based reactions to analog input signals<\/li>\n<li>Automatic transmission of CAN frames on state changes or defined events<\/li>\n<li>Driving relay and MOSFET outputs based on received CAN data<\/li>\n<li>Fail-safe or timeout behavior for defined output states in case of communication failure<\/li>\n<li>Reduction of external control logic for simple automation tasks<\/li>\n<li>Integration of additional I\/O functions into existing CAN, vehicle and machine control systems<\/li>\n<\/ul>\n<\/section>\n","sge_text":"<p>The DEDITEC CAN Box CB-R8-M4-AD8\/_M is a CAN I\/O module for vehicles, special-purpose vehicles, mobile machinery, and industrial CAN networks. It combines CAN 2.0A\/B with 8 switching relays, 4 MOSFET outputs, and 8 analog inputs for decentralized switching, measurement, and control tasks. The analog inputs detect voltage signals in the range of 0\u201318 V with 12-bit resolution; starting in 2026, the MOSFET outputs will be rated for 2.8\u201336 V DC and up to 9 A DC with a maximum of one connected output, or up to 6 A DC otherwise. Auto TX\/RX, M2M-CAN, and Event Control enable the automatic transmission and reception of CAN packets as well as simple control logic directly within the module. As a result, the CAN Box connects sensors, actuators, and retrofitted devices to the CAN system of a vehicle, a mobile machine, or an industrial plant.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\r\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">HOW IS THE CB-R8-M4-AD8\/_M INTEGRATED INTO A CAN NETWORK?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>The module is integrated into the existing CAN network via its CAN interface. Before commissioning, the CAN address, baud rate, and desired operating mode must be configured. The module can then send and receive CAN messages and respond to them accordingly.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">ARE THERE SOFTWARE TOOLS FOR COMMISSIONING AND DIAGNOSTICS?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Yes, the ICT-Tool provides extensive functions for configuring, testing, and monitoring the operating status of the modules. In addition, firmware updates can be performed directly via the tool.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND DETAILED INFORMATION ABOUT THE HARDWARE OF THE CB-R8-M4-AD8\/_M?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Detailed information about the hardware, such as pin assignment, power supply, technical specifications, and mechanical dimensions, can be found in the module manual. The manual is available directly on the product page under the \"Downloads and Manuals\" tab as well as in the download section of the DEDITEC homepage.<\/p>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\r\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25585080","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25585080"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584832"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25585080"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25585080"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25585080"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25585080"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}