{"id":25576097,"date":"2025-08-12T11:29:50","date_gmt":"2025-08-12T09:29:50","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/?post_type=product&#038;p=25576097"},"modified":"2026-08-14T16:09:42","modified_gmt":"2026-08-14T14:09:42","slug":"tcp-digital-inputs-16","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/ethernet\/tcp-digital-inputs-16\/","title":{"rendered":"digital inputs ethernet module with 16 optocoupler inputs, web interface (Modbus TCP-compatible)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25588095,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1583,245],"product_tag":[],"class_list":{"0":"post-25576097","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-eingaenge","7":"einausgang-di16","8":"schnittstelle-ethernet-en","9":"schnittstelle-wifi-en","10":"product_cat-ethernet","11":"product_cat-uc","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"purchasable","18":"product-type-simple"},"acf":{"sge_text":"<p>The UC-ETH-O16 offers 16 galvanically isolated digital inputs for the reliable acquisition of 5\u201350 V signals via Ethernet or Modbus-TCP. Ideal for industrial monitoring, e.g., for monitoring machine status or for acquiring external switching signals in building and process automation. Features a web interface, input filter, and 16-bit counters per channel.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-ETH-O16 with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supported protocols<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only TCP<\/td>\n<td data-label=\"UC-ETH-O16\">HTTP, UDP, TCP, DHCP, Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Expands application possibilities in modern network and IoT infrastructures.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Ethernet Signal Isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not always galvanically isolated<\/td>\n<td data-label=\"UC-ETH-O16\">Galvanically isolated Ethernet interface for safe communication<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Protects connected systems from interference voltages and increases communication stability in industrial networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"UC-ETH-O16\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Counter function per channel<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only simple status queries or a global counting function.<\/td>\n<td data-label=\"UC-ETH-O16\">16-bit counters per channel with up to 65,535 count cycles.<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Enables direct capture of pulses and events without additional hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Wide voltage range<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only positive voltage levels are allowed.<\/td>\n<td data-label=\"UC-ETH-O16\">Positive and negative voltages can be detected <\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Expands compatibility with various sensor signals and reduces the need for upstream signal conditioning.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Input filter<\/strong><\/td>\n<td data-label=\"Market Comparison\">Filter functions are often fixed or can only be configured to a limited extent.<\/td>\n<td data-label=\"UC-ETH-O16\">Programmable filter for input state changes and counter functions.<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Reduces bounce and improves the reliable detection of actual switching signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status display<\/strong><\/td>\n<td data-label=\"Market Comparison\">Channel statuses are often only visible to a limited extent or in aggregate.<\/td>\n<td data-label=\"UC-ETH-O16\">LED status indicator per input and output channel for quick visual inspection.<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Speeds up diagnostics, commissioning, and troubleshooting directly at the module.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Detection of state changes<\/strong><\/td>\n<td data-label=\"Market Comparison\">Signal changes between two readout cycles are sometimes lost in standard modules.<\/td>\n<td data-label=\"UC-ETH-O16\">Internal flip-flops detect transitions from low to high and high to low between two readout operations.<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Improves event detection for short signal transitions and asynchronous state changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Signal isolation of the inputs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes without galvanic isolation or with reduced protection between the field and logic sides.<\/td>\n<td data-label=\"UC-ETH-O16\">Electrically isolated optocoupler inputs for safe signal operation<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Increases operational reliability when detecting external switching and sensor signals.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially without visual indicators<\/td>\n<td data-label=\"UC-ETH-O16\">LED status indicators per channel for fast diagnostics<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Enables rapid on-site status analysis and reduces the effort required for troubleshooting and diagnostics.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Remote access<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely possible<\/td>\n<td data-label=\"UC-ETH-O16\">Direct access via web and Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Allows for configuration and monitoring without physical presence, thereby supporting efficient maintenance processes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"UC-ETH-O16\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"UC-ETH-O16\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>High reliability thanks to M2M functionality<\/strong><\/td>\n<td data-label=\"Market Comparison\">A control PC is required<\/td>\n<td data-label=\"UC-ETH-O16\">Built-in M2M functionality enables autonomous operation without a PC<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Ensures continued operation even in the event of a control PC failure and increases system availability.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-ETH-O16\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-ETH-O16\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"UC-ETH-O16\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"UC-ETH-O16\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-ETH-O16\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"UC-ETH-O16\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"UC-ETH-O16\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-ETH-O16\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-ETH-O16\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-ETH-O16\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-ETH-O16\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-ETH-O16\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"UC-ETH-O16\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-ETH-O16\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-ETH-O16\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-ETH-O16\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-ETH-O16\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-ETH-O16\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-ETH-O16\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"UC-ETH-O16\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"UC-ETH-O16\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-ETH-O16\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-ETH-O16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules with digital inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-ETH-O16\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"UC-ETH-O16\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-ETH-O16\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the modules with digital inputs\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The UC-ETH-O16 features 16 digital inputs (optocouplers) for 5\u201350 V AC\/DC, with galvanic isolation up to 2.5 kV. Each channel has a 16-bit counter up to 10 kHz and an internal flip-flop for reliably capturing rapid state changes. An input filter (1\u2013255 ms) is adjustable per channel. Communication takes place via 10\/100 Mbit\/s Ethernet or Modbus-TCP, optionally via Wi-Fi. LEDs for each input facilitate diagnostics and commissioning.<br \/>\n<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<li>Electrically isolated up to 1.5 kV<\/li>\n<\/ul>\n<h3>Wi-Fi interface:<\/h3>\n<ul>\n<li>Wi-Fi connection available<\/li>\n<li>WPS feature<\/li>\n<\/ul>\n<h3>Digital inputs:<\/h3>\n<ul>\n<li>Type: AC\/DC optocoupler<\/li>\n<li>Signal level: \u00b15 V to \u00b115 V or \u00b115 V to \u00b130 V<\/li>\n<li>16-bit counter per channel (up to 100 Hz)<\/li>\n<li>Detects a transition from low to high and from high to low (flip-flop)<\/li>\n<li>Status LED for each channel<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-ETH-O16\">\n<h2>Product Description \u2013 modul with digital inputs<\/h2>\n<p>The DEDITEC UC-ETH-O16 module, featuring 16 digital inputs, offers a powerful and reliable solution for capturing switching signals in industrial and building automation applications. The inputs are optically isolated, effectively minimizing interference and protecting connected systems. With its fast and stable communication via Modbus TCP, the module can be seamlessly integrated into modern Ethernet-based control architectures. Additionally, HTTP, UDP, and the open DEDITEC TCP protocol are available, enabling flexible integration into a wide variety of software environments.<br \/>\nThe robust WAGO connectors, the mis-insertion-proof design, and the simple mounting on a DIN rail ensure a secure installation and high operational reliability. All digital inputs can be conveniently monitored and configured via the integrated web interface. The DELIB API also enables direct control under Windows and Linux, making the modul with digital inputs ideal for custom automation projects.<br \/>\nTypical applications include monitoring machine and plant conditions, building automation, safety technology, IoT sensors, and the detection of external switches, pushbuttons, or signal contacts. Thanks to the combination of industrial-grade hardware, flexible communication, and high signal quality, the UC-ETH-O16 is a reliable choice for all applications requiring precise digital inputs.<\/p>\n<h3>Flexible network communication via Ethernet &#038; Wi-Fi<\/h3>\n<p>The Ethernet and WiFi interfaces of the UC-ETH-O16 enable flexible integration into existing networks\u2014both wired and wireless. Via Ethernet (10\/100 Mbps), the modul with digital inputs can be operated with a static or dynamic IP address and accessed directly through standard network protocols, while WiFi allows wireless integration, for example via WPS or manual configuration.<br \/>\nBoth communication methods support access through an integrated web interface as well as driver libraries and a mobile app, enabling simple parameterization and remote control. A key feature is the ability to make the modul with digital inputs accessible across the entire network and operate it via browser, software tools, or mobile devices.<br \/>\nOverall, Ethernet and WiFi provide scalable and location-independent communication within industrial applications.<\/p>\n<h3>Control &#038; software<\/h3>\n<p>For control purposes, the modul with digital inputs provides open protocols (TCP\/IP, Modbus TCP, and HTTP), enabling flexible integration into existing IT and automation environments. These protocols allow both traditional industrial applications and modern IoT scenarios to be implemented directly, without the need for additional gateways or proprietary interfaces.<br \/>\nIn addition, comprehensive API libraries are available for Python, C, C++, C#, Java, VB, and other programming languages, enabling the functions of the UC-ETH-O16 to be seamlessly integrated into custom software solutions.<br \/>\nThe DELIB driver library, including CLI tools, also enables fast and straightforward commissioning as well as direct control via scripts or the command line, which is particularly useful for test, automation, and development environments. Furthermore, the I\/O Control App for mobile devices provides a convenient way to remotely control and monitor the system over the network, without requiring a traditional PC application.<br \/>\nOverall, this creates a highly flexible control architecture ranging from low-level integration to mobile operation.<\/p>\n<h3>Galvanically isolated digital inputs with filtering functions for reliable signal acquisition<\/h3>\n<p>The digital inputs on the UC-ETH-O16 are implemented as opto-isolated switching inputs, ensuring reliable galvanic isolation between the field side and the internal electronics. They are designed for industrial 24 V AC\/DC signals and enable safe detection of switching states even in electrically noisy environments. The integrated filtering function suppresses short interference pulses, ensuring stable signal processing.<br \/>\nIn addition, the inputs feature event detection that reliably captures signal transitions and makes them available for further processing. In combination with counter and flip-flop functions, even fast pulses or state changes can be evaluated precisely. Each input of the UC-ETH-O16 is also equipped with an individual status LED that visually indicates the current switching state directly on the device, enabling fast on-site diagnostics.<br \/>\nAs a result, the digital inputs are ideally suited for industrial automation tasks where robust and reliable signal acquisition is required.<\/p>\n<h3>Event Control \u2013 event-based automation<\/h3>\n<p>The Event Control function enables direct, event-driven processing of both digital and analog signals in the modul with digital inputs, without requiring cyclic polling by higher-level software. Digital signal transitions can immediately trigger internal actions, while analog signals can generate events based on defined thresholds, measurement ranges, or significant value changes. This allows responses to be implemented much faster and more resource-efficiently compared to traditional polling-based processing.<br \/>\nThe event logic can be flexibly configured, enabling both simple switching conditions and more complex dependencies between digital and analog signals. In addition, functions such as filtering, hysteresis, and threshold monitoring are available to ensure stable and reliable trigger conditions.<br \/>\nAs a result, Event Control is particularly well suited for automation applications where signals must be evaluated intelligently and processed immediately.<\/p>\n<h3>Robust industrial design with a well-engineered connection and mounting architecture<\/h3>\n<p>The modul with digital inputs is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-ETH-O16, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm\u00b2. In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.<\/p>\n<h3>Integration and Operational Safety<\/h3>\n<p>The UC-ETH-O16 is a robust solution for industrial applications that require reliable processing of digital signals. Thanks to stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated into existing systems. The galvanically isolated electronics, \u201cMade in Germany,\u201d ensure high operational reliability, while regular updates and direct developer support enable long-term, stable use in professional environments.<br \/>\n<br \/>\n<\/section>\n","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE SOFTWARE TOOLS FOR COMMISSIONING AND DIAGNOSTICS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, the ICT-Tool provides extensive functions for configuring, testing, and monitoring the operating status of the modules. In addition, firmware updates can be performed directly via the tool.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN C#?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, we provide a package with ready-made programming examples for controlling our modules in C#.\nThe package also includes sample code for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT THE AVAILABLE INTERFACES AND FUNCTIONS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete description of the supported interfaces, communication options, and device functions can be found in the module manual. It is available at any time via the \"Downloads and Manuals\" tab on the respective product page as well as in the download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE ARE THE COMMANDS FOR CONTROLLING THE MODULE DOCUMENTED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The available commands for controlling and querying the module are described in detail in the module manual. Alternatively, the corresponding information can also be found on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25576097","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25576097"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25588095"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25576097"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25576097"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25576097"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25576097"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}