{"id":25571359,"date":"2019-11-22T13:50:57","date_gmt":"2019-11-22T12:50:57","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/ro-ser-da-iso\/"},"modified":"2026-08-14T16:04:51","modified_gmt":"2026-08-14T14:04:51","slug":"sensor-module-galvanically-isolated-0-10v-0-20ma-outputs","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/seriell-rs-232-rs-485\/sensor-module-galvanically-isolated-0-10v-0-20ma-outputs\/","title":{"rendered":"Sensor module, galvanically isolated 0-10V, 0-20mA outputs * RS-232\/RS-485 &#8211; Outputs Module with 2\/4\/8 D\/A outputs (galvanically isolated)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25585887,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[165,142],"product_tag":[],"class_list":{"0":"post-25571359","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ao2","7":"einausgang-ao4","8":"einausgang-ao8","9":"einausgang-analoge-ausgaenge","10":"einausgang-_analog","11":"schnittstelle-seriell","12":"product_cat-seriell-rs-232-rs-485","13":"product_cat-ro","14":"pa_anzahl-kanaele-da-2_da_ch_de","15":"pa_anzahl-kanaele-da-4_da_ch_de","16":"pa_anzahl-kanaele-da-8_da_ch_de","18":"first","19":"instock","20":"taxable","21":"shipping-taxable","22":"purchasable","23":"product-type-variable"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of RO-SER-DA2-8_ISO with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Analog voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Basic analog outputs, often only 0\u20135 V or 0\u201310 V<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Precise voltage output over 0\u20135 V, 0\u201310 V or \u00b110 V<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Enables precise control of various actuators and reduces the need for external signal converters.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Current and voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some providers offer only voltage or only current<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Both signal types supported<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Increases compatibility with various industrial and process signals and simplifies integration into existing systems.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Low output ripple<\/strong><\/td>\n<td data-label=\"Market Comparison\">Stronger ripple in OEM modules<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Low ripple and stable output signals<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Improves signal quality and ensures stable output values in sensitive control and regulation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Protects connected devices from interference voltages and prevents feedback between the output stage and the power supply.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation between all channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often a common reference potential for all channels<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Galvanic isolation up to 500 V between all channels<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Enables operation in systems with different reference potentials and prevents compensation currents between channels.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Add modules later<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only a fixed number of I\/Os per module<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Additional I\/O modules can be added freely<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Enables step-by-step system expansion without replacing existing hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Form factor<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one standard housing available<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Large selection of module variants<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Allows for application-specific selection and facilitates integration into various installation scenarios.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series maturity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many products are new or frequently revised<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Series with 15+ years of history<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Offers a proven platform with stable firmware and mature hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"RO-SER-DA2-8_ISO\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the sensor modules\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Laboratory and measurement technology:<br \/><\/strong>Stable 16-bit voltage outputs provide reliable signals for measurement and test systems.<\/li>\n<li><strong>Research &#038; Development:<br \/><\/strong>With the RO-SER-DA2-8_ISO, output voltages can be adjusted flexibly and quickly, which is particularly advantageous in experiments and prototype development.<\/li>\n<li><strong>Industrial process control:<br \/><\/strong>Analog signals can be flexibly output to actuators and control variables using the sensor module.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The serial analog output module features 2, 4, or 8 galvanically isolated D\/A outputs with 16-bit resolution for the precise output of voltage and current signals. Signal ranges of 0\u201310 V and 0\u201320 mA are supported for communication via RS-232, RS-485, or USB 2.0. The rugged industrial design with galvanic isolation, high signal stability, and flexible configuration enables reliable operation in demanding environments. The module is suitable for control, regulation, testing, and automation tasks.<br \/>\n<\/p>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>RS-232 interface:<\/h3>\n<ul>\n<li>RS-232 interface with up to 115,200 baud<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<li>Configurable via the ICT tool or, alternatively, via DIP switches<\/li>\n<\/ul>\n<h3>RS-485 interface:<\/h3>\n<ul>\n<li>RS-485 interface with up to 115,200 baud<\/li>\n<li>TIA\/EIA-485-A standard<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Analog outputs:<\/h3>\n<ul>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V<\/li>\n<li>Current ranges: 0\u201320 mA, 4\u201320 mA, 0\u201324 mA<\/li>\n<li>Channel-to-channel isolation: max. 1 kV AC<\/li>\n<li>Isolation from power supply: max. 500 V AC<\/li>\n<li>Load resistance: \u2265 1 k\u03a9<\/li>\n<li>All D\/A channels are galvanically isolated from one another<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-RO-SER-DA2-8_ISO\">\n<h2>Product Description \u2013 sensor module<\/h2>\n<p>The RO-SER-DA2-8_ISO is an industrial D\/A converter module for generating precise analog output signals via the serial interfaces RS-232 and RS-485. Communication is based on an open register-based protocol that enables direct and channel-accurate control of the analog outputs. In addition, a plain-text terminal mode is available, allowing simple testing and diagnostic functions without the need for special software. The USB interface is used exclusively for configuration as well as diagnostics and testing of output functions via the ICT-Tool.<br \/>\nThe sensor module is available in different expansion variants with varying numbers of analog outputs. Depending on the version, 1, 2, or 4 analog D\/A outputs are provided. All outputs operate with 16-bit resolution, enabling very fine and precise scaling of output signals. The outputs can generate voltage or current signals in the industrial standard range of 0\u201310 V or 0\/4\u201320 mA (depending on configuration). Due to the high resolution, the sensor module is particularly well suited for precise setpoint generation in control and simulation applications.<br \/>\nThe outputs are galvanically isolated, ensuring safe separation between control logic and output stage. Each channel is register-addressable and can be written and updated independently. Control is fully handled via the open serial protocol or alternatively via plain-text commands in terminal mode. The ICT-Tool additionally enables configuration of the serial interface as well as diagnostics, calibration, and functional testing of the outputs.<\/p>\n<h3>Robust serial communication interface for industrial applications<\/h3>\n<p>The serial interface of the RO-SER-DA2-8_ISO is based on established industrial standards such as RS-232 and RS-485, enabling reliable asynchronous data transmission between control systems and peripheral devices. It operates with a clearly defined open protocol, allowing easy integration into existing automation environments.<br \/>\nThrough RS-485, longer cable distances and bus topologies can also be implemented, making it suitable for distributed systems. The RS-232 interface is particularly well suited for direct point-to-point connections, for example for configuration or parameterization tasks.<br \/>\nThanks to the robust serial transmission technology in the sensor module, stable communication is ensured even in electrically noisy industrial environments. In addition, galvanic isolation of the communication interfaces provides enhanced protection for both the control system and connected devices.<br \/>\nOverall, the serial interface offers a flexible and industrial-grade solution for a wide range of integration scenarios.<\/p>\n<h3>Structured protocol control for flexible system integration<\/h3>\n<p>The control of the RO-SER-DA2-8_ISO is carried out via a structured, command-based protocol that enables direct communication with higher-level control systems or PCs. Commands for configuration, querying, and parameterization are transmitted via the serial interface and are clearly interpreted by the sensor module.<br \/>\nThanks to the modular structure of the protocol, easy integration into existing software and PLC environments is possible. Communication can be either cyclic or event-driven, allowing flexible adaptation to different applications.<br \/>\nOverall, this control approach enables precise and reliable operation as well as seamless integration of the module into industrial automation systems.<\/p>\n<h3>Precise analog outputs for demanding control and regulation applications<\/h3>\n<p>The sensor module features analog outputs with 16-bit resolution, enabling very fine and highly reproducible signal generation. Supported voltage ranges include 0\u20135 V, 0\u201310 V, as well as \u00b15 V and \u00b110 V, allowing flexible adaptation to different industrial actuators. The outputs offer high accuracy, low drift, and stable long-term performance, even during continuous operation.<br \/>\nWith short response times, the system is also well suited for dynamic control processes and rapid setpoint changes. Overall, the RO-SER-DA2-8_ISO is ideal for precise control and regulation tasks in demanding industrial environments.<\/p>\n<h3>Form factor and connectors<\/h3>\n<p>The sensor module is designed for demanding industrial use and features a robust construction. Its housing is shock-resistant and vibration-proof, making it suitable for installation in control cabinets and on DIN rail mounting systems.<br \/>\nThe I\/Os of the RO-SER-DA2-8_ISO are wired via WAGO connectors, providing a secure, vibration-resistant connection. The module supports an operating temperature range from -20 \u00b0C to +60 \u00b0C and is designed for continuous operation under industrial conditions.<br \/>\nThanks to these features, it offers high reliability, a long service life, and easy maintenance, making it ideal for automation, mechanical engineering, and laboratory control applications.<\/p>\n<h3>User Benefits and Practical Application<\/h3>\n<p>The RO-SER-DA2-8_ISO offers a practical solution for industrial control and monitoring tasks. Its rugged, galvanically isolated electronics ensure reliable operation, while the documentation, drivers, and ICT diagnostic tool enable quick integration. Thanks to regular updates and direct developer support, the module remains operational over the long term and supports sustainable planning in professional environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"<p>The RO-SER-DA2-8_ISO is a high-performance sensor module designed for industrial automation and control applications. Its galvanically isolated 0\u201310 V and 0\u201320 mA outputs enable precise and interference-free signal transmission in demanding environments. The module is ideally suited for mechanical engineering, building automation, as well as measurement and control technology. Thanks to its serial RS-232 and RS-485 interfaces, the device can be flexibly integrated into existing systems. High-quality components, a compact design, and reliable signal processing ensure maximum operational reliability in continuous industrial operation.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW IS THE MODULE ADDRESS USED IN RS-485 SYSTEMS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>In RS-485 systems, a unique address can be assigned to the RO-SER-DA2-8_ISO. This allows multiple devices to operate on the same bus system without address conflicts.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHICH SOFTWARE AND PROGRAMMING LANGUAGES ARE SUPPORTED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The DELIB API supports numerous programming languages such as Python, C, C++, C#, VB, VB.NET, and Java. In addition, sample programs and a command-line interface solution for Windows and Linux are available. This allows the sensor modules to be quickly integrated into existing software projects.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN C#?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, we provide a package with ready-made programming examples for controlling our modules in C#.\nThe package also includes sample code for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT COMMISSIONING THE RO-SER-DA2-8_ISO?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All important information regarding commissioning, wiring, configuration, and initial setup is described in the module manual. The document can be downloaded via the \"Downloads and Manuals\" section on the product page or through the central download area of the homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND EXAMPLES FOR SOFTWARE-BASED CONTROL OF THE MODULE?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Examples for controlling the module, as well as information about supported programming languages and libraries, can be found in the module documentation and on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25571359","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25571359"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25585887"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25571359"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25571359"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25571359"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25571359"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}