{"id":25571291,"date":"2019-11-22T14:33:25","date_gmt":"2019-11-22T13:33:25","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/ro-ser-di-do-mos\/"},"modified":"2026-10-06T15:49:48","modified_gmt":"2026-10-06T13:49:48","slug":"rs-232-hybrid-optocoupler-mos-low-power-switching-module","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/seriell-rs-232-rs-485\/rs-232-hybrid-optocoupler-mos-low-power-switching-module\/","title":{"rendered":"RS-232 hybrid optocoupler MOS low-power switching module * RS-232\/RS-485 &#8211; Digital input\/output module with 16\/32\/64 inputs and 16\/32\/64 outputs (optocoupler 3A)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25586120,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[165,142],"product_tag":[],"class_list":{"0":"post-25571291","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-eingaenge","7":"einausgang-di16","8":"einausgang-digitale-ausgaenge","9":"einausgang-di32","10":"einausgang-do16","11":"einausgang-di64","12":"einausgang-do32","13":"einausgang-do64","14":"einausgang-_digital","15":"schnittstelle-seriell","16":"product_cat-seriell-rs-232-rs-485","17":"product_cat-ro","18":"pa_anzahl-kanaele-di-do-16_di_do_ch_de","19":"pa_anzahl-kanaele-di-do-32_di_do_ch_de","20":"pa_anzahl-kanaele-di-do-64_di_do_ch_de","22":"first","23":"instock","24":"taxable","25":"shipping-taxable","26":"purchasable","27":"product-type-variable"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of RO-SER-O16-64-M16-64 with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Counter function per channel<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only simple status queries or a global counting function.<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">16-bit counters per channel with up to 65,535 count cycles.<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables direct capture of pulses and events without additional hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Wide voltage range<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only positive voltage levels are allowed.<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Positive and negative voltages can be detected <\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Expands compatibility with various sensor signals and reduces the need for upstream signal conditioning.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Input filter<\/strong><\/td>\n<td data-label=\"Market Comparison\">Filter functions are often fixed or can only be configured to a limited extent.<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Programmable filter for input state changes and counter functions.<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Reduces bounce and improves the reliable detection of actual switching signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status display<\/strong><\/td>\n<td data-label=\"Market Comparison\">Channel statuses are often only visible to a limited extent or in aggregate.<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">LED status indicator per input and output channel for quick visual inspection.<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Speeds up diagnostics, commissioning, and troubleshooting directly at the module.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Detection of state changes<\/strong><\/td>\n<td data-label=\"Market Comparison\">Signal changes between two readout cycles are sometimes lost in standard modules.<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Internal flip-flops detect transitions from low to high and high to low between two readout operations.<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Improves event detection for short signal transitions and asynchronous state changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Signal isolation of the inputs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes without galvanic isolation or with reduced protection between the field and logic sides.<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Electrically isolated optocoupler inputs for safe signal operation<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Increases operational reliability when detecting external switching and sensor signals.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status LEDs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly only general status LEDs<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Dedicated LED for each channel<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables quick status monitoring of each output and simplifies troubleshooting without the need for additional measuring equipment.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>High switching durability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Cheap relays with short lifespan<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Durable industrial relays for high switching cycles<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Extends the service life of the outputs and reduces maintenance and replacement intervals in applications with frequent switching.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Fail-safe mode<\/strong><\/td>\n<td data-label=\"Market Comparison\">Only partially offered and not as flexible to configure<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">On connection loss, each output switches to a predefined state<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Prevents undefined switching states and increases operational safety in the event of a fault.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially without visual indicators<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">LED status indicators per channel for fast diagnostics<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables rapid on-site status analysis and reduces the effort required for troubleshooting and diagnostics.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Add modules later<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only a fixed number of I\/Os per module<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Additional I\/O modules can be added freely<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables step-by-step system expansion without replacing existing hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Form factor<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one standard housing available<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Large selection of module variants<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Allows for application-specific selection and facilitates integration into various installation scenarios.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Combined I\/Os<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors separate I\/O types \u2192 more modules required<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Analog and digital I\/Os in one module<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Reduces the number of modules required and simplifies wiring and system architecture.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Input channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">8\u201332 channels<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">16, 32, 64 or 128 channels<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Supports applications with high signal density and reduces space requirements per channel.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series maturity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many products are new or frequently revised<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Series with 15+ years of history<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Offers a proven platform with stable firmware and mature hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-O16-64-M16-64<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"RO-SER-O16-64-M16-64\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the RS-232 low-power hybrid optocoupler and MOS switching modules\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Energy and load management:<br \/><\/strong>The RS-232 low-power hybrid optocoupler and MOS switching module enables targeted switching of loads and energy sources, for example in energy management systems, backup power solutions, or smart distribution networks.<\/li>\n<li><strong>Research and development:<br \/><\/strong>Use in laboratories and test environments for scientific experiments and test setups.<\/li>\n<li><strong>Safety-critical control systems (fail-safe):<br \/><\/strong>The integrated fail-safe and timeout function of the RO-SER-O16-64-M16-64 ensures that defined states are automatically maintained in the event of communication failures\u2014especially important for safety-critical applications.<\/li>\n<li><strong>Industrial automation:<br \/><\/strong>It monitors digital signals from machines and production systems for precise control and process management.<\/li>\n<li><strong>Laboratory automation:<br \/><\/strong>Digital signals from machines and production systems are reliably captured by the RS-232 low-power hybrid optocoupler and MOS switching module and provided for precise process control.<\/li>\n<li><strong>Mechanical engineering:<br \/><\/strong>Through the RO-SER-O16-64-M16-64, galvanically isolated inputs can be directly integrated into machine control systems, ensuring high immunity to interference.<\/li>\n<li><strong>Process monitoring:<br \/><\/strong>It delivers real-time data from production lines or test systems for continuous monitoring.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The RS-232 hybrid module combines electrically isolated optocoupler inputs and MOSFET outputs for low-power switching of digital loads. It supports direct control via RS-232\/RS-485 as well as optional USB 2.0 and offers a rugged industrial design with configurable channels, integrated protection logic, and plain-text-based communication. Typical applications include the control of actuators, valves, and relays, as well as integration into PLC and automation systems for process and machine control.<br \/>\n<\/p>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>RS-232 interface:<\/h3>\n<ul>\n<li>RS-232 interface with up to 115,200 baud<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<li>Configurable via the ICT tool or, alternatively, via DIP switches<\/li>\n<\/ul>\n<h3>RS-485 interface:<\/h3>\n<ul>\n<li>RS-485 interface with up to 115,200 baud<\/li>\n<li>TIA\/EIA-485-A standard<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>MOSFET outputs 3 A:<\/h3>\n<ul>\n<li>Max. switching voltage: 36 V DC<\/li>\n<li>Min. switching voltage: 2.8 V DC<\/li>\n<li>Max. switching current: 3 A DC<\/li>\n<li>Max. switching power: 108 W DC<\/li>\n<li>Timeout protection function (configurable via software)<\/li>\n<li>Status LED for each output<\/li>\n<\/ul>\n<h3>Digital inputs:<\/h3>\n<ul>\n<li>Type: AC\/DC optocoupler<\/li>\n<li>Signal level: \u00b15 V to \u00b115 V or \u00b115 V to \u00b130 V<\/li>\n<li>16-bit counter per channel (up to 100 Hz)<\/li>\n<li>Detects a transition from low to high and from high to low (flip-flop)<\/li>\n<li>Status LED for each channel<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-RO-SER-O16-64-M16-64\">\n<h2>Product Description \u2013 RS-232 low-power hybrid optocoupler and MOS switching module<\/h2>\n<p>The RO-SER-O16-64-M16-64 is an industrial digital input\/output module for processing switching signals via serial interfaces. Depending on the configuration, the RS-232 low-power hybrid optocoupler and MOS switching module provides 16, 32, or 64 digital inputs and outputs. The digital inputs are optically isolated and support both AC and DC signals in the industrial voltage range of 15\u201330 V, with an optional 5\u201315 V range.<br \/>\nThe digital outputs are implemented as P-channel MOSFET outputs and enable switching of loads up to 2 A per channel. Communication is handled via RS-232 or RS-485, both with galvanically isolated interfaces. In addition, the RS-232 low-power hybrid optocoupler and MOS switching module can be operated and configured via USB 2.0.<br \/>\nControl is performed via an open serial protocol with register access or alternatively in plain-text mode. Each input includes functions such as filtering, edge detection, flip-flop capture, and a 16-bit counter.<br \/>\nThe module is designed for DIN rail mounting and continuous industrial operation.<\/p>\n<h3>Robust serial communication interface for industrial applications<\/h3>\n<p>The serial interface of the RO-SER-O16-64-M16-64 is based on established industrial standards such as RS-232 and RS-485, enabling reliable asynchronous data transmission between control systems and peripheral devices. It operates with a clearly defined open protocol, allowing easy integration into existing automation environments.<br \/>\nThrough RS-485, longer cable distances and bus topologies can also be implemented, making it suitable for distributed systems. The RS-232 interface is particularly well suited for direct point-to-point connections, for example for configuration or parameterization tasks.<br \/>\nThanks to the robust serial transmission technology in the RS-232 low-power hybrid optocoupler and MOS switching module, stable communication is ensured even in electrically noisy industrial environments. In addition, galvanic isolation of the communication interfaces provides enhanced protection for both the control system and connected devices.<br \/>\nOverall, the serial interface offers a flexible and industrial-grade solution for a wide range of integration scenarios.<\/p>\n<h3>Structured protocol control for flexible system integration<\/h3>\n<p>The control of the RO-SER-O16-64-M16-64 is carried out via a structured, command-based protocol that enables direct communication with higher-level control systems or PCs. Commands for configuration, querying, and parameterization are transmitted via the serial interface and are clearly interpreted by the RS-232 low-power hybrid optocoupler and MOS switching module.<br \/>\nThanks to the modular structure of the protocol, easy integration into existing software and PLC environments is possible. Communication can be either cyclic or event-driven, allowing flexible adaptation to different applications.<br \/>\nOverall, this control approach enables precise and reliable operation as well as seamless integration of the module into industrial automation systems.<\/p>\n<h3>Galvanically isolated digital inputs with filtering functions for reliable signal acquisition<\/h3>\n<p>The digital inputs on the RO-SER-O16-64-M16-64 are implemented as opto-isolated switching inputs, ensuring reliable galvanic isolation between the field side and the internal electronics. They are designed for industrial 24 V AC\/DC signals and enable safe detection of switching states even in electrically noisy environments. The integrated filtering function suppresses short interference pulses, ensuring stable signal processing.<br \/>\nIn addition, the inputs feature event detection that reliably captures signal transitions and makes them available for further processing. In combination with counter and flip-flop functions, even fast pulses or state changes can be evaluated precisely. Each input of the RO-SER-O16-64-M16-64 is also equipped with an individual status LED that visually indicates the current switching state directly on the device, enabling fast on-site diagnostics.<br \/>\nAs a result, the digital inputs are ideally suited for industrial automation tasks where robust and reliable signal acquisition is required.<\/p>\n<h3>High-performance MOS outputs<\/h3>\n<p>The MOS outputs of the RO-SER-O16-64-M16-64 enable direct switching of relays, valves, or signal lamps. Each output features integrated short-circuit protection and overload protection, ensuring safe and long-term operation. The fast switching speed provides reliable real-time actuator control.<br \/>\nChannel-by-channel control allows flexible control scenarios, while galvanic isolation keeps interference away from the rest of the system. Thanks to robust MOS technology, the RS-232 low-power hybrid optocoupler and MOS switching module is ideal for projects of any size.<\/p>\n<h3>Form factor and connectors<\/h3>\n<p>The RS-232 low-power hybrid optocoupler and MOS switching module is designed for demanding industrial use and features a robust construction. Its housing is shock-resistant and vibration-proof, making it suitable for installation in control cabinets and on DIN rail mounting systems.<br \/>\nThe I\/Os of the RO-SER-O16-64-M16-64 are wired via WAGO connectors, providing a secure, vibration-resistant connection. The module supports an operating temperature range from -20 \u00b0C to +60 \u00b0C and is designed for continuous operation under industrial conditions.<br \/>\nThanks to these features, it offers high reliability, a long service life, and easy maintenance, making it ideal for automation, mechanical engineering, and laboratory control applications.<\/p>\n<h3>Integration and Operational Safety<\/h3>\n<p>The RO-SER-O16-64-M16-64 is a robust solution for industrial applications that require reliable processing of digital signals. Thanks to stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated into existing systems. The galvanically isolated electronics, \u201cMade in Germany,\u201d ensure high operational reliability, while regular updates and direct developer support enable long-term, stable use in professional environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"<p>The RO-SER-O16-64-M16-64 is an industrial interface module designed for reliable signal processing in automation and control systems. It combines RS-232 hybrid optocoupler technology with MOS transistor outputs for low-power switching applications. This ensures galvanic isolation and interference-resistant transmission of digital signals. The module is ideally suited for industrial applications requiring precise control with low energy consumption. Thanks to its optocoupler technology, sensitive control circuits are protected while enabling fast switching operations. Its robust design ensures high operational reliability during continuous use. As a versatile switching module, it supports efficient automation solutions in industrial applications, building technology, and machine control while meeting high demands for reliability and signal quality.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\r\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">CAN THE MODULE BE OPERATED WITHOUT A PERMANENT PC CONNECTION VIA RS-232\/RS-485?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Yes, after initial configuration, the module can operate independently within the serial network. Communication then takes place directly between the control device (master) and the module.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">CAN THE MODULE BE USED WITHOUT AN ADDITIONAL PLC?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Yes, thanks to the integrated event control, control tasks can be executed directly on the module. Using the ICT-Tool, \u201cif-then\u201d actions can be configured, enabling many applications to be implemented without an additional control PC or PLC.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN PYTHON?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Yes. In the download section of our website, we provide a comprehensive example package. It contains ready-made Python programming examples that allow you to quickly integrate our modules into your application.\r\nIn addition, you will also find examples for other supported programming languages.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT THE AVAILABLE INTERFACES AND FUNCTIONS?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>A complete description of the supported interfaces, communication options, and device functions can be found in the module manual. It is available at any time via the \"Downloads and Manuals\" tab on the respective product page as well as in the download section of the DEDITEC homepage.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">WHERE ARE THE COMMANDS FOR CONTROLLING THE MODULE DOCUMENTED?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>The available commands for controlling and querying the module are described in detail in the module manual. Alternatively, the corresponding information can also be found on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\r\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25571291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25571291"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25586120"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25571291"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25571291"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25571291"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25571291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}