{"id":25571258,"date":"2019-11-22T15:34:39","date_gmt":"2019-11-22T14:34:39","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/ro-ser-do-rel-um\/"},"modified":"2026-08-14T16:06:19","modified_gmt":"2026-08-14T14:06:19","slug":"rs-232-output-digital-outputs-switch-relay-module-8-16-32-outputs","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/seriell-rs-232-rs-485\/rs-232-output-digital-outputs-switch-relay-module-8-16-32-outputs\/","title":{"rendered":"RS-232 output digital outputs switching relay module * SER 8\/16\/32 * Switch changeover relays (bistable relays) via an RS-232\/RS-485 interface"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25586142,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1474,166],"product_tag":[],"class_list":{"0":"post-25571258","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-ausgaenge","7":"einausgang-do8","8":"einausgang-do16","9":"einausgang-do32-en","10":"schnittstelle-seriell-en","11":"product_cat-seriell-rs-232-rs-485","12":"product_cat-ro","13":"pa_anzahl-kanaele-do-16_do_ch_en","14":"pa_anzahl-kanaele-do-32_do_ch_en","15":"pa_anzahl-kanaele-do-8_do_ch_en","17":"first","18":"instock","19":"taxable","20":"shipping-taxable","21":"purchasable","22":"product-type-variable"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of RO-SER-R8-32_UM with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-R8-32_UM<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 digital output modules with switching relay outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status LEDs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly only general status LEDs<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Dedicated LED for each channel<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Enables quick status monitoring of each output and simplifies troubleshooting without the need for additional measuring equipment.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>High switching durability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Cheap relays with short lifespan<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Durable industrial relays for high switching cycles<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Extends the service life of the outputs and reduces maintenance and replacement intervals in applications with frequent switching.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Fail-safe mode<\/strong><\/td>\n<td data-label=\"Market Comparison\">Only partially offered and not as flexible to configure<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">On connection loss, each output switches to a predefined state<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Prevents undefined switching states and increases operational safety in the event of a fault.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Output type<\/strong><\/td>\n<td data-label=\"Market Comparison\">Standard outputs are often grouped together without specifying their relay characteristics in detail.<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Relay outputs with normally open (NO) contacts for standard industrial switching applications.<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Suitable for reliably switching external loads in typical industrial applications.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-R8-32_UM<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 digital output modules with switching relay outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially without visual indicators<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">LED status indicators per channel for fast diagnostics<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Enables rapid on-site status analysis and reduces the effort required for troubleshooting and diagnostics.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-R8-32_UM<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 digital output modules with switching relay outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Add modules later<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only a fixed number of I\/Os per module<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Additional I\/O modules can be added freely<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Enables step-by-step system expansion without replacing existing hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Form factor<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one standard housing available<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Large selection of module variants<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Allows for application-specific selection and facilitates integration into various installation scenarios.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-R8-32_UM<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 digital output modules with switching relay outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-R8-32_UM<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 digital output modules with switching relay outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-R8-32_UM<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 digital output modules with switching relay outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series maturity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many products are new or frequently revised<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Series with 15+ years of history<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Offers a proven platform with stable firmware and mature hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-R8-32_UM<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 digital output modules with switching relay outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-R8-32_UM<\/th >\n<th style=\"color: #555;\">Practical Benefits of the RS-232 digital output modules with switching relay outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"RO-SER-R8-32_UM\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the RS-232 digital output modules with switching relay outputs\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Energy and load management:<br \/><\/strong>The RS-232 digital output module with switching relay outputs enables targeted switching of loads and energy sources, for example in energy management systems, backup power solutions, or smart distribution networks.<\/li>\n<li><strong>Research and development:<br \/><\/strong>Use in laboratories and test environments for scientific experiments and test setups.<\/li>\n<li><strong>Safety-critical control systems (fail-safe):<br \/><\/strong>The integrated fail-safe and timeout function of the RO-SER-R8-32_UM ensures that defined states are automatically maintained in the event of communication failures\u2014especially important for safety-critical applications.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The module is an industrial digital output module with 8, 16, or 32 bistable relay outputs, controlled via RS-232 or RS-485, as well as optionally via USB 2.0. The outputs are electrically isolated and designed to switch DC loads up to 30 V DC \/ 2 A. Serial communication is handled via an open protocol with a configurable baud rate and optional register or plain-text mode. A status indicator is integrated for each channel. The module is suitable for decentralized control and safe switching of loads in industrial automation and control applications.<br \/>\n<\/p>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>RS-232 interface:<\/h3>\n<ul>\n<li>RS-232 interface with up to 115,200 baud<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<li>Configurable via the ICT tool or, alternatively, via DIP switches<\/li>\n<\/ul>\n<h3>RS-485 interface:<\/h3>\n<ul>\n<li>RS-485 interface with up to 115,200 baud<\/li>\n<li>TIA\/EIA-485-A standard<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Relay outputs 1 A:<\/h3>\n<ul>\n<li>Selectable between 8, 16, or 32 channels<\/li>\n<li>Type: Changeover, bistable (CO)<\/li>\n<li>Max. switching voltage: 48 V DC<\/li>\n<li>Max. switching current: 2 A DC<\/li>\n<li>Max. switching power: 60 W<\/li>\n<li>Timeout protection function (configurable via software)<\/li>\n<li>2 LEDs per relay (switching states)<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-RO-SER-R8-32_UM\">\n<h2>Product Description \u2013 RS-232 digital output module with switching relay outputs<\/h2>\n<p>The RO-SER-R8-32_UM is an industrial relay module for controlling bistable changeover relays via serial interfaces. It supports RS-232 and RS-485 communication standards and can additionally be operated via USB 2.0. The RS-232 digital output module with switching relay outputs is available in versions with 8, 16, or 32 relay outputs.<br \/>\nBistable relays with changeover (CO) contacts are used as output elements, allowing them to retain their switching state even when power is removed. The maximum switching capacity is up to 48 V DC at 2 A or 60 W per relay contact.<br \/>\nControl is carried out via an open register-based protocol or in plain-text mode. Galvanic isolation between the interface and output stage ensures safe signal transmission in industrial environments. Each relay channel features two LED indicators for status feedback of the switching state.<br \/>\nThe RS-232 digital output module with switching relay outputs is designed for DIN rail mounting and intended for use in industrial control and automation systems.<\/p>\n<h3>Robust serial communication interface for industrial applications<\/h3>\n<p>The serial interface of the RO-SER-R8-32_UM is based on established industrial standards such as RS-232 and RS-485, enabling reliable asynchronous data transmission between control systems and peripheral devices. It operates with a clearly defined open protocol, allowing easy integration into existing automation environments.<br \/>\nThrough RS-485, longer cable distances and bus topologies can also be implemented, making it suitable for distributed systems. The RS-232 interface is particularly well suited for direct point-to-point connections, for example for configuration or parameterization tasks.<br \/>\nThanks to the robust serial transmission technology in the RS-232 digital output module with switching relay outputs, stable communication is ensured even in electrically noisy industrial environments. In addition, galvanic isolation of the communication interfaces provides enhanced protection for both the control system and connected devices.<br \/>\nOverall, the serial interface offers a flexible and industrial-grade solution for a wide range of integration scenarios.<\/p>\n<h3>Structured protocol control for flexible system integration<\/h3>\n<p>The control of the RO-SER-R8-32_UM is carried out via a structured, command-based protocol that enables direct communication with higher-level control systems or PCs. Commands for configuration, querying, and parameterization are transmitted via the serial interface and are clearly interpreted by the RS-232 digital output module with switching relay outputs.<br \/>\nThanks to the modular structure of the protocol, easy integration into existing software and PLC environments is possible. Communication can be either cyclic or event-driven, allowing flexible adaptation to different applications.<br \/>\nOverall, this control approach enables precise and reliable operation as well as seamless integration of the module into industrial automation systems.<\/p>\n<h3>Powerful and safe relay outputs for industrial switching tasks<\/h3>\n<p>The outputs of the RO-SER-R8-32_UM consist of bistable changeover relays (CO contacts), each of which can be switched independently and retains its switching state even when power is removed. Each output is designed for a maximum switching voltage of up to 48 V AC\/DC and a switching current of up to 12 A, enabling safe switching of higher loads in the low-voltage range.<br \/>\nDue to galvanic isolation of the relay contacts (up to approx. 1 kV to the coil side), reliable separation between control and load circuits is ensured. In addition, the RS-232 digital output module with switching relay outputs provides high switching capacity and is designed for industrial continuous operation, including protection functions such as timeout monitoring and status LEDs per channel. This makes it particularly suitable for robust switching tasks in automation, test, and control applications.<\/p>\n<h3>Form factor and connectors<\/h3>\n<p>The RS-232 digital output module with switching relay outputs is designed for demanding industrial use and features a robust construction. Its housing is shock-resistant and vibration-proof, making it suitable for installation in control cabinets and on DIN rail mounting systems.<br \/>\nThe I\/Os of the RO-SER-R8-32_UM are wired via WAGO connectors, providing a secure, vibration-resistant connection. The module supports an operating temperature range from -20 \u00b0C to +60 \u00b0C and is designed for continuous operation under industrial conditions.<br \/>\nThanks to these features, it offers high reliability, a long service life, and easy maintenance, making it ideal for automation, mechanical engineering, and laboratory control applications.<\/p>\n<h3>User Benefits and Practical Application<\/h3>\n<p>The RO-SER-R8-32_UM offers a practical solution for industrial control and monitoring tasks. Its rugged, galvanically isolated electronics ensure reliable operation, while the documentation, drivers, and ICT diagnostic tool enable quick integration. Thanks to regular updates and direct developer support, the module remains operational over the long term and supports sustainable planning in professional environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"<p>The RO-SER-R8-32_UM is an industrial RS-232 output module with digital outputs and an integrated changeover relay function for reliable control and switching of digital loads in automation systems. Depending on the version, it provides 8, 16, or 32 galvanically isolated relay outputs and ensures flexible, stable switching processes in industrial environments. The robust RS-232 interface guarantees interference-resistant communication between the controller and peripheral devices. Thanks to its low-power relay technology, the module is ideally suited for machine control, process automation, and building automation, and can be easily integrated into existing systems.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHICH OPERATING MODES ARE AVAILABLE FOR SERIAL COMMUNICATION?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Depending on the configuration, different operating modes can be used, such as text mode or register mode. These define how data is interpreted and exchanged between the master and the module.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHICH SOFTWARE AND PROGRAMMING LANGUAGES ARE SUPPORTED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The DELIB API supports numerous programming languages such as Python, C, C++, C#, VB, VB.NET, and Java. In addition, sample programs and a command-line interface solution for Windows and Linux are available. This allows the RS-232 digital output modules with switching relay outputs to be quickly integrated into existing software projects.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN VB?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section, we provide a sample package that contains ready-made VB code for controlling our modules.\nIn addition, the package includes implementation examples for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND CURRENT DOCUMENTATION AND TECHNICAL RESOURCES?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Current manuals, technical documentation, and other product-specific materials can be found directly on the product page under \"Downloads and Manuals\". In addition, these documents are also available for download in the central download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND AN OVERVIEW OF ALL AVAILABLE API COMMANDS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete overview of all supported API commands can be found in the manual of the respective module. In addition, the API documentation is available on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25571258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25571258"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25586142"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25571258"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25571258"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25571258"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25571258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}