{"id":25571252,"date":"2019-11-22T15:42:12","date_gmt":"2019-11-22T14:42:12","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/ro-ser-cnt-igr\/"},"modified":"2026-08-14T16:04:34","modified_gmt":"2026-08-14T14:04:34","slug":"serial-io-igr-encoder-detection","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/seriell-rs-232-rs-485\/serial-io-igr-encoder-detection\/","title":{"rendered":"Serial I\/O IGR encoder acquisition * DIN rail RS-232\/RS-485 module with inputs for 2\/4 incremental encoders"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25585883,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[165,142],"product_tag":[],"class_list":{"0":"post-25571252","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-counter-igr","7":"schnittstelle-seriell","8":"product_cat-seriell-rs-232-rs-485","9":"product_cat-ro","10":"pa_anzahl-kanaele-igr-2_igr_outputs_de","11":"pa_anzahl-kanaele-igr-4_igr_outputs_de","13":"first","14":"instock","15":"taxable","16":"shipping-taxable","17":"purchasable","18":"product-type-variable"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of RO-SER-CNT\/IGR2-4 with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-CNT\/IGR2-4<\/th >\n<th style=\"color: #555;\">Practical Benefits of the serial I\/O IGR modules for encoder acquisition<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-CNT\/IGR2-4<\/th >\n<th style=\"color: #555;\">Practical Benefits of the serial I\/O IGR modules for encoder acquisition<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Add modules later<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only a fixed number of I\/Os per module<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Additional I\/O modules can be added freely<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Enables step-by-step system expansion without replacing existing hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Form factor<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one standard housing available<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Large selection of module variants<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Allows for application-specific selection and facilitates integration into various installation scenarios.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-CNT\/IGR2-4<\/th >\n<th style=\"color: #555;\">Practical Benefits of the serial I\/O IGR modules for encoder acquisition<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-CNT\/IGR2-4<\/th >\n<th style=\"color: #555;\">Practical Benefits of the serial I\/O IGR modules for encoder acquisition<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-CNT\/IGR2-4<\/th >\n<th style=\"color: #555;\">Practical Benefits of the serial I\/O IGR modules for encoder acquisition<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series maturity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many products are new or frequently revised<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Series with 15+ years of history<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Offers a proven platform with stable firmware and mature hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-CNT\/IGR2-4<\/th >\n<th style=\"color: #555;\">Practical Benefits of the serial I\/O IGR modules for encoder acquisition<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-SER-CNT\/IGR2-4<\/th >\n<th style=\"color: #555;\">Practical Benefits of the serial I\/O IGR modules for encoder acquisition<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"RO-SER-CNT\/IGR2-4\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the serial I\/O IGR modules for encoder acquisition\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Machine control &#038; motion tracking:<br \/><\/strong>Encoder signal acquisition for position and speed monitoring in production machines.<\/li>\n<li><strong>Position detection in conveyor systems:<br \/><\/strong>Use of IGR inputs for precise detection of conveyor run or position triggers.<\/li>\n<li><strong>Counting functions in inspection and test systems:<br \/><\/strong>High-frequency pulses for performance, counting, and quality measurement are reliably captured and processed by the RO-SER-CNT\/IGR2-4.<\/li>\n<li><strong>Research and development:<br \/><\/strong>Use in laboratories and test environments for scientific experiments and test setups.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The serial DIN-rail module features 2 or 4 inputs for detecting incremental encoders and supports high-resolution count, frequency, and PWM measurements. Communication takes place via RS-232 or RS-485 with galvanically isolated interfaces and configurable operating modes. Rugged industrial connectors, fast signal processing, and comprehensive diagnostic functions enable reliable continuous operation. The module is suitable for position, speed, and motion monitoring in automation, testing, and conveyor systems.<br \/>\n<\/p>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>RS-232 interface:<\/h3>\n<ul>\n<li>RS-232 interface with up to 115,200 baud<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<li>Configurable via the ICT tool or, alternatively, via DIP switches<\/li>\n<\/ul>\n<h3>RS-485 interface:<\/h3>\n<ul>\n<li>RS-485 interface with up to 115,200 baud<\/li>\n<li>TIA\/EIA-485-A standard<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Temperature inputs:<\/h3>\n<ul>\n<li>2 input counters (max. 10 MHz)<\/li>\n<li>Connection for 2\/4 incremental encoders via 3 differential inputs each<\/li>\n<li>Internal 48-bit counter<\/li>\n<li>Reference setting via limit switches<\/li>\n<li>Electrical isolation of the inputs<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-RO-SER-CNT\/IGR2-4\">\n<h2>Product Description \u2013 serial I\/O IGR module for encoder acquisition<\/h2>\n<p>The RO-SER-CNT\/IGR2-4 is an industrial counter and incremental encoder module for capturing and processing high-frequency pulse signals via serial interfaces such as RS-232 and RS-485. Communication is based on an open register-based protocol that enables direct addressing of all counter channels and incremental encoder inputs. In addition, the serial I\/O IGR module for encoder acquisition can be accessed via a plain-text terminal protocol, allowing simple testing and diagnostic functions without the need for special software.<br \/>\nThe USB interface is used exclusively for configuration as well as diagnostics and testing of I\/O functions via the ICT-Tool and has no function in the real-time counter communication. The serial I\/O IGR module for encoder acquisition supports configuration of the serial interface (e.g., baud rate, mode, address in RS-485) as well as switching between text and register modes.<br \/>\nDepending on the version, the system includes incremental encoder inputs for precise acquisition of rotational and position signals, as well as additional digital counting and I\/O functions within the CNT architecture. The inputs are designed for fast pulse sequences and reliably detect state changes even at high frequencies. Each channel is register-addressed and can be read or reset individually.<br \/>\nCommunication via RS-232 or RS-485 is designed for industrial environments and enables robust data transmission even over long distances. Status LEDs per channel support local diagnosis of signal states and counting activity. Integration is fully carried out via the open serial protocol or through direct terminal commands.<\/p>\n<h3>Robust serial communication interface for industrial applications<\/h3>\n<p>The serial interface of the RO-SER-CNT\/IGR2-4 is based on established industrial standards such as RS-232 and RS-485, enabling reliable asynchronous data transmission between control systems and peripheral devices. It operates with a clearly defined open protocol, allowing easy integration into existing automation environments.<br \/>\nThrough RS-485, longer cable distances and bus topologies can also be implemented, making it suitable for distributed systems. The RS-232 interface is particularly well suited for direct point-to-point connections, for example for configuration or parameterization tasks.<br \/>\nThanks to the robust serial transmission technology in the serial I\/O IGR module for encoder acquisition, stable communication is ensured even in electrically noisy industrial environments. In addition, galvanic isolation of the communication interfaces provides enhanced protection for both the control system and connected devices.<br \/>\nOverall, the serial interface offers a flexible and industrial-grade solution for a wide range of integration scenarios.<\/p>\n<h3>Structured protocol control for flexible system integration<\/h3>\n<p>The control of the RO-SER-CNT\/IGR2-4 is carried out via a structured, command-based protocol that enables direct communication with higher-level control systems or PCs. Commands for configuration, querying, and parameterization are transmitted via the serial interface and are clearly interpreted by the serial I\/O IGR module for encoder acquisition.<br \/>\nThanks to the modular structure of the protocol, easy integration into existing software and PLC environments is possible. Communication can be either cyclic or event-driven, allowing flexible adaptation to different applications.<br \/>\nOverall, this control approach enables precise and reliable operation as well as seamless integration of the module into industrial automation systems.<\/p>\n<h3>High-precision incremental encoder module for fast position and motion detection<\/h3>\n<p>The RO-SER-CNT\/IGR2-4 is designed for precise acquisition and evaluation of incremental encoder signals in industrial applications. It processes high-frequency pulses with input rates of up to 20 MHz and provides 48-bit counter resolution, enabling reliable capture of very fast and finely resolved movements. The galvanically isolated inputs ensure safe signal processing and protect the connected application from interference and potential differences.<br \/>\nDepending on the version, 2 or 4 independent encoder channels are available, which can be flexibly used for position, speed, or direction measurements. Thanks to its high accuracy and robust industrial design, the serial I\/O IGR module for encoder acquisition is ideally suited for machine control, conveyor systems, and automated measurement systems.<\/p>\n<h3>Form factor and connectors<\/h3>\n<p>The serial I\/O IGR module for encoder acquisition is designed for demanding industrial use and features a robust construction. Its housing is shock-resistant and vibration-proof, making it suitable for installation in control cabinets and on DIN rail mounting systems.<br \/>\nThe I\/Os of the RO-SER-CNT\/IGR2-4 are wired via WAGO connectors, providing a secure, vibration-resistant connection. The module supports an operating temperature range from -20 \u00b0C to +60 \u00b0C and is designed for continuous operation under industrial conditions.<br \/>\nThanks to these features, it offers high reliability, a long service life, and easy maintenance, making it ideal for automation, mechanical engineering, and laboratory control applications.<\/p>\n<h3>Maintenance and Long-Term Planning<\/h3>\n<p>The RO-SER-CNT\/IGR2-4 supports users with a durable, industrial-grade architecture that enables predictable use over many years. The combination of robust drivers, comprehensive documentation, and the ICT diagnostic tool simplifies commissioning and maintenance. Electrical isolation and high-quality electronics ensure reliable operation, while support and continuous updates guarantee seamless integration into professional automation environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"<p>The RO-SER-CNT\/IGR2-4 is an industrial module for serial IO incremental encoder acquisition via RS-232 and RS-485. It processes incremental encoder signals with high precision, supports 2 or 4 channels depending on the variant, and uses an open register protocol for easy integration into control and automation systems.<br \/>\nThe galvanically isolated inputs, status LEDs, and robust design ensure reliable operation even in demanding industrial environments. In addition, it is designed for fast pulse signals up to 20 MHz and provides a 48-bit counter resolution for highly precise measurements. This makes it well suited for long-term, stable process data acquisition.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHICH OPERATING MODES ARE AVAILABLE FOR SERIAL COMMUNICATION?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Depending on the configuration, different operating modes can be used, such as text mode or register mode. These define how data is interpreted and exchanged between the master and the module.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE ICT TOOL BE USED WITHOUT ANY CUSTOM PROGRAMMING?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, the ICT-Tool enables direct access to the modules without the need for custom software development. This allows functions, interfaces, and I\/O states to be quickly tested and verified.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN VB?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section, we provide a sample package that contains ready-made VB code for controlling our modules.\nIn addition, the package includes implementation examples for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT COMMISSIONING THE RO-SER-CNT\/IGR2-4?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All important information regarding commissioning, wiring, configuration, and initial setup is described in the module manual. The document can be downloaded via the \"Downloads and Manuals\" section on the product page or through the central download area of the homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND EXAMPLES FOR SOFTWARE-BASED CONTROL OF THE MODULE?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Examples for controlling the module, as well as information about supported programming languages and libraries, can be found in the module documentation and on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25571252","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25571252"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25585883"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25571252"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25571252"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25571252"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25571252"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}