{"id":25568874,"date":"2019-11-13T15:55:26","date_gmt":"2019-11-13T14:55:26","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/ro-can-da-iso\/"},"modified":"2026-08-14T16:02:59","modified_gmt":"2026-08-14T14:02:59","slug":"can-sensor-module-galvanically-isolated-0-10v-0-20ma-outputs","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/raw-can-j1939\/can-sensor-module-galvanically-isolated-0-10v-0-20ma-outputs\/","title":{"rendered":"Sensor module with galvanically isolated 0-10 V and 0-20 mA outputs * CAN analog output modules with 2\/4\/8 * D\/A outputs with 16 bit (galvanically isolated)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25585849,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1473,166],"product_tag":[],"class_list":{"0":"post-25568874","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ao2","7":"einausgang-ao4","8":"einausgang-ao8","9":"einausgang-analoge-ausgaenge","10":"schnittstelle-can-en","11":"product_cat-raw-can-j1939","12":"product_cat-ro","13":"pa_anzahl-kanaele-da-2_da_ch_en","14":"pa_anzahl-kanaele-da-4_da_ch_en","15":"pa_anzahl-kanaele-da-8_da_ch_en","17":"first","18":"instock","19":"taxable","20":"shipping-taxable","21":"purchasable","22":"product-type-variable"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of RO-CAN-DA2-8_ISO with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Protocol transparency<\/strong><\/td>\n<td data-label=\"Market Comparison\">For many standard modules, the telegram structure or integration is manufacturer-specific.<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Open CAN protocol for seamless integration into existing CAN architectures.<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Facilitates integration into existing controllers, gateways, and CAN networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automatic telegram processing<\/strong><\/td>\n<td data-label=\"Market Comparison\">Recurring CAN telegrams often have to be processed using external control logic.<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Auto TX\/RX mode for automatic processing of CAN packets.<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Reduces the implementation effort in the controller and simplifies recurring communication tasks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>CAN standards and bit rates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Supported CAN parameters are often limited or less clearly specified.<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Supports CAN 2.0A \/ 2.0B and bit rates from 10 kbit\/s to 1 Mbit\/s.<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Offers greater flexibility when integrating into different CAN systems and existing installations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Interfaces<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only USB or PCI<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">USB, Ethernet and web interface<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables flexible connectivity options in various IT and industrial environments.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Analog voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Basic analog outputs, often only 0\u20135 V or 0\u201310 V<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Precise voltage output over 0\u20135 V, 0\u201310 V or \u00b110 V<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables precise control of various actuators and reduces the need for external signal converters.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Current and voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some providers offer only voltage or only current<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Both signal types supported<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Increases compatibility with various industrial and process signals and simplifies integration into existing systems.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Low output ripple<\/strong><\/td>\n<td data-label=\"Market Comparison\">Stronger ripple in OEM modules<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Low ripple and stable output signals<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Improves signal quality and ensures stable output values in sensitive control and regulation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Protects connected devices from interference voltages and prevents feedback between the output stage and the power supply.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation between all channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often a common reference potential for all channels<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Galvanic isolation up to 500 V between all channels<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables operation in systems with different reference potentials and prevents compensation currents between channels.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Add modules later<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only a fixed number of I\/Os per module<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Additional I\/O modules can be added freely<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables step-by-step system expansion without replacing existing hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Form factor<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one standard housing available<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Large selection of module variants<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Allows for application-specific selection and facilitates integration into various installation scenarios.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series maturity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many products are new or frequently revised<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Series with 15+ years of history<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Offers a proven platform with stable firmware and mature hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-DA2-8_ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"RO-CAN-DA2-8_ISO\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Process optimization through automation:<br \/><\/strong>Thanks to the integrated auto TX\/RX mode, modules can communicate directly with each other and exchange signals\u2014without the need for an additional control PC.<\/li>\n<li><strong>Decentralized CAN network nodes:<br \/><\/strong>The sensor module with galvanically isolated 0-10 V and 0-20 mA outputs is suitable as a decentralized CAN I\/O unit within industrial control architectures. Via the CAN bus, states and data are reliably transmitted and distributed to other system participants, enabling the integration of remote system areas into a centralized structure.<\/li>\n<li><strong>Laboratory and measurement technology:<br \/><\/strong>Stable 16-bit voltage outputs provide reliable signals for measurement and test systems.<\/li>\n<li><strong>Research &#038; Development:<br \/><\/strong>With the RO-CAN-DA2-8_ISO, output voltages can be adjusted flexibly and quickly, which is particularly advantageous in experiments and prototype development.<\/li>\n<li><strong>Industrial process control:<br \/><\/strong>Analog signals can be flexibly output to actuators and control variables using the sensor module with galvanically isolated 0-10 V and 0-20 mA outputs.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The RO-CAN-DA2\/4\/8_ISO CAN sensor module features 2, 4, or 8 galvanically isolated D\/A outputs with 16-bit resolution for the precise output of voltage and current signals in the range of 0\u201310 V and 0\u201324 mA. Communication takes place via a galvanically isolated CAN 2.0A\/B interface with an open CAN protocol and automatic TX\/RX mode. Thanks to its high signal accuracy and galvanic isolation, the module is suitable for industrial automation, measurement technology, test benches, and process control systems.<br \/>\n<\/p>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>CAN interface:<\/h3>\n<ul>\n<li>CAN interface according to ISO 11898<\/li>\n<li>Open CAN protocol<\/li>\n<li>RAW CAN\/J1939<\/li>\n<li>Automatic transmit\/receive mode<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Analog outputs:<\/h3>\n<ul>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V<\/li>\n<li>Current ranges: 0\u201320 mA, 4\u201320 mA, 0\u201324 mA<\/li>\n<li>Channel-to-channel isolation: max. 1 kV AC<\/li>\n<li>Isolation from power supply: max. 500 V AC<\/li>\n<li>Load resistance: \u2265 1 k\u03a9<\/li>\n<li>All D\/A channels are galvanically isolated from one another<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-RO-CAN-DA2-8_ISO\">\n<h2>Product Description \u2013 sensor module with galvanically isolated 0-10 V and 0-20 mA outputs<\/h2>\n<p>The RO-CAN-DA2-8_ISO is an industrial CAN bus remote I\/O system for galvanically isolated output of analog voltage signals. Communication is carried out via CAN 2.0A\/2.0B using RAW CAN or J1939, as well as the configurable Auto TX\/RX mode for autonomous data exchange within the network. In addition, a USB 2.0 interface is available for parameterization, diagnostics, and commissioning.<br \/>\nThe analog outputs deliver precise voltage signals in the range of 0\u201310 V or \u00b110 V (depending on configuration), enabling both unipolar and bipolar control variables. The output stages are galvanically isolated from the system up to 2.5 kV AC, providing strong protection against interference and potential differences in industrial environments. The resolution of the D\/A converters enables fine and stable signal generation for control and regulation tasks.<br \/>\nPower is supplied via 12\u201324 V DC, allowing easy integration into existing control cabinet systems. Status LEDs provide information on communication and module states and simplify diagnostics during operation.<br \/>\nThrough the M2M CAN function, the sensor module with galvanically isolated 0-10 V and 0-20 mA outputs can also directly exchange data with other devices in the network without requiring a central controller.<\/p>\n<h3>CAN interface with flexible USB configuration<\/h3>\n<p>The CAN interface of the RO-CAN-DA2-8_ISO is based on the CAN 2.0A\/B standard and enables robust, error-resistant communication via RAW CAN or J1939 in industrial networks. It supports the typical multi-master CAN bus architecture, allowing multiple nodes to efficiently exchange data without a central controller. The bit rate is flexibly configurable, enabling the sensor module with galvanically isolated 0-10 V and 0-20 mA outputs to be easily adapted to different network speeds and system environments. Communication is handled via standardized CAN telegrams with event-driven data transmission for fast and reliable signal processing.<br \/>\nThe entire CAN configuration, including TX\/RX behavior, is conveniently carried out via the integrated USB interface on a PC. This allows parameters such as bus speed and message handling to be quickly configured and tested. This combination of CAN and USB connectivity significantly simplifies commissioning and reduces integration and diagnostic effort.<\/p>\n<h3>Flexible CAN control via auto TX\/RX and DELIB command mode<\/h3>\n<p>The RO-CAN-DA2-8_ISO can generally be controlled using two operating modes: Auto TX\/RX mode and DELIB command mode. In Auto TX\/RX mode, the module can automatically transmit and receive CAN packets without requiring a permanently connected control PC. Both RAW CAN and J1939 are supported.<br \/>\nAlternatively, DELIB command mode provides direct register-based access via a manufacturer-specific CAN protocol, allowing specific commands to be transmitted to the sensor module with galvanically isolated 0-10 V and 0-20 mA outputs. Read and write operations are implemented using defined CAN IDs and structured data packets, enabling highly flexible and precise control.<br \/>\nThese control modes can be conveniently configured on a PC via the integrated USB interface. The corresponding tool allows parameters such as communication behavior, TX\/RX logic and the DELIB command structure to be easily configured and tested. This enables the sensor module with galvanically isolated 0-10 V and 0-20 mA outputs to be quickly adapted to different applications and efficiently integrated into existing CAN systems.<\/p>\n<h3>Precise analog outputs for demanding control and regulation applications<\/h3>\n<p>The sensor module with galvanically isolated 0-10 V and 0-20 mA outputs features analog outputs with 16-bit resolution, enabling very fine and highly reproducible signal generation. Supported voltage ranges include 0\u20135 V, 0\u201310 V, as well as \u00b15 V and \u00b110 V, allowing flexible adaptation to different industrial actuators. The outputs offer high accuracy, low drift, and stable long-term performance, even during continuous operation.<br \/>\nWith short response times, the system is also well suited for dynamic control processes and rapid setpoint changes. Overall, the RO-CAN-DA2-8_ISO is ideal for precise control and regulation tasks in demanding industrial environments.<\/p>\n<h3>M2M communication \u2013 direct device-to-device networking<\/h3>\n<p>The M2M (machine-to-machine) function enables direct communication between multiple modules or systems without a central control unit. States and events can be automatically exchanged and synchronized between devices, allowing the creation of distributed and autonomously operating automation structures. Communication is carried out via defined protocols and can be flexibly integrated into existing system architectures. As a result, M2M is particularly well suited for connected industrial and IoT applications.<\/p>\n<h3>Form factor and connectors<\/h3>\n<p>The sensor module with galvanically isolated 0-10 V and 0-20 mA outputs is designed for demanding industrial use and features a robust construction. Its housing is shock-resistant and vibration-proof, making it suitable for installation in control cabinets and on DIN rail mounting systems.<br \/>\nThe I\/Os of the RO-CAN-DA2-8_ISO are wired via WAGO connectors, providing a secure, vibration-resistant connection. The module supports an operating temperature range from -20 \u00b0C to +60 \u00b0C and is designed for continuous operation under industrial conditions.<br \/>\nThanks to these features, it offers high reliability, a long service life, and easy maintenance, making it ideal for automation, mechanical engineering, and laboratory control applications.<\/p>\n<h3>Application and Benefits<\/h3>\n<p>The RO-CAN-DA2-8_ISO offers a reliable and long-term solution for industrial automation tasks. With stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated and efficiently maintained. The robust electronics, developed in Germany and featuring galvanic isolation, ensure high operational reliability, while direct developer support and regular updates guarantee sustainable use in professional environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"<p>The RO-CAN-DA2-8_ISO is a sensor module with up to 8 galvanically isolated 0\u201310 V and 0\u201320 mA outputs for industrial measurement and automation applications. It enables precise acquisition and output of analog signals via the CAN bus and ensures reliable integration into existing systems. The galvanic isolation provides a high level of interference immunity and effectively protects the electronics. This makes the module ideally suited for mechanical engineering, automotive technology, and industrial applications with high demands for flexible signal processing and stable data communication.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE RO-CAN-DA2-8_ISO AUTOMATICALLY SEND CAN MESSAGES AT FIXED TIME INTERVALS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In Auto TX mode, cyclic transmission intervals can be defined. This allows CAN messages to be transmitted automatically at the desired intervals without requiring an external controller.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHICH SOFTWARE AND PROGRAMMING LANGUAGES ARE SUPPORTED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The DELIB API supports numerous programming languages such as Python, C, C++, C#, VB, VB.NET, and Java. In addition, sample programs and a command-line interface solution for Windows and Linux are available. This allows the sensor modules with galvanically isolated 0-10 V and 0-20 mA outputs to be quickly integrated into existing software projects.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN C#?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, we provide a package with ready-made programming examples for controlling our modules in C#.\nThe package also includes sample code for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT COMMISSIONING THE RO-CAN-DA2-8_ISO?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All important information regarding commissioning, wiring, configuration, and initial setup is described in the module manual. The document can be downloaded via the \"Downloads and Manuals\" section on the product page or through the central download area of the homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE ARE THE COMMANDS FOR CONTROLLING THE MODULE DOCUMENTED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The available commands for controlling and querying the module are described in detail in the module manual. Alternatively, the corresponding information can also be found on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25568874","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568874"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25585849"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568874"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25568874"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25568874"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25568874"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}