{"id":25568843,"date":"2019-11-14T13:46:50","date_gmt":"2019-11-14T12:46:50","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/ro-can-di-do-rel\/"},"modified":"2026-09-14T10:15:38","modified_gmt":"2026-09-14T08:15:38","slug":"can-io-module-digital-input-and-output-module","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/raw-can-j1939\/can-io-module-digital-input-and-output-module\/","title":{"rendered":"CAN I\/O module * CAN module with 16\/32\/64 inputs and 16\/32\/64 outputs (relay 1A)"},"content":{"rendered":"<h2>Product Description \u2013 RO-CAN CAN I\/O Module<\/h2>\n<p>The RO-CAN CAN I\/O module is an industrial CAN bus remote I\/O module for connecting digital inputs and outputs in distributed automation and control systems. It was developed for continuous use in industrial environments and supports decentralized I\/O concepts with high requirements for reliability and electrical safety.<\/p>\n<p>Thanks to CAN bus communication, the module can be seamlessly integrated into existing control architectures and is particularly well-suited for modular machine designs, distributed plant structures, and remote I\/O applications. Digital signals can be acquired and switched throughout the system without complex cabling or reliance on central I\/O.<\/p>\n<p>The RO-CAN module is typically used when digital inputs and outputs are not to be wired centrally to a PLC, but must instead be integrated decentrally into distributed plant structures. Especially when the number of channels increases or when modules are physically separated, a CAN-based remote I\/O system reduces wiring effort and improves system transparency.<\/p>\n<p>A CAN-based remote I\/O system such as the RO-CAN is used in particular when a scalable, easy-to-maintain, and electrically robust I\/O architecture is required. Unlike centrally wired relay cards or proprietary expansion systems, the CAN bus enables flexible expansion within a clearly structured system topology.<\/p>\n<h2>Reliable signal processing in industrial CAN networks<\/h2>\n<p>In industrial CAN systems, potential differences, noise pulses, or inductive interference often occur. The RO-CAN module electrically isolates the I\/O channels from the control level, thereby reducing electrical interference and reliably protecting connected controllers.<\/p>\n<p>This decoupling is a critical factor for operational safety, particularly in cases involving longer cable runs, decentralized assemblies, or mixed loads.<\/p>\n<h2>Versatile for a variety of automation tasks<\/h2>\n<p>The CAN I\/O module is designed for a wide range of industrial applications in which digital signals need to be acquired or switched locally via the CAN bus. Typical applications include:<\/p>\n<ul>\n<li>Connecting digital sensors and actuators to CAN controllers<\/li>\n<li>Decentralized I\/O expansion in machine and plant control systems<\/li>\n<li>Wiring tasks in electrical panel and control system construction<\/li>\n<li>Signal Processing in Building and Specialized Control Systems<\/li>\n<\/ul>\n<p>Thanks to the wide range of options available within the RO-CAN series, the module can be tailored to meet specific project requirements and system architectures.<\/p>\n<h2>Integration into existing CAN control architectures<\/h2>\n<p>The RO-CAN module is integrated directly into existing CAN bus structures as a decentralized CAN remote I\/O. Communication takes place without proprietary extension systems or additional gateways, allowing the module to be seamlessly integrated into existing control architectures.<\/p>\n<p>Thanks to its clear bus structure, the module is suitable both for new machine designs and for expanding existing systems with additional digital inputs and outputs.<\/p>\n<p>Unlike IO-Link systems, the RO-CAN module functions as a traditional CAN remote I\/O for digital signals and is particularly well-suited for harsh industrial environments with bus-based system architecture.<\/p>\n<h2>Industrial-grade quality from the manufacturer<\/h2>\n<p>As an industrial product developed in Germany, the RO-CAN module from DEDITEC is synonymous with durable hardware, clear documentation, and reliable operation in professional environments. It is designed and manufactured with a focus on industrial requirements, as well as for use in the DACH market and in international automation projects.<\/p>\n","protected":false},"excerpt":{"rendered":"<h2>Technical Specifications<\/h2>\n<p>The RO-CAN-DI\/DO-REL is an industrial CAN I\/O module designed to acquire digital input signals and control digital outputs via the CAN bus. With galvanically isolated optocoupler inputs, relay outputs, and variants featuring 16, 32, or 64 digital inputs and outputs, the module is suitable for mechanical engineering, control panel construction, test benches, and decentralized automation systems.<\/p>\n<h3>At a glance<\/h3>\n<ul>\n<li>CAN remote I\/O module with 16, 32, or 64 digital inputs and outputs<\/li>\n<li>Digital inputs via electrically isolated optocouplers<\/li>\n<li>Relay outputs for industrial switching tasks<\/li>\n<li>Supply voltage: +12 V to +24 V DC<\/li>\n<li>CAN 2.0A \/ 2.0B with bit rates from 10 kbit\/s to 1 Mbit\/s<\/li>\n<li>16-bit counter per input channel<\/li>\n<li>Adjustable input filter from 0 to 255 ms<\/li>\n<li>Fail-safe and timeout functions for defined output shutdown<\/li>\n<li>LED status indicator per I\/O channel<\/li>\n<li>Mounting on 35 x 7.5 mm DIN rail<\/li>\n<\/ul>\n<h3>Interface and Communication<\/h3>\n<ul>\n<li>CAN interface via 9-pin D-Sub connector<\/li>\n<li>Support for CAN 2.0A and CAN 2.0B<\/li>\n<li>Data rates from 10 kbit\/s to 1 Mbit\/s<\/li>\n<li>Electrically isolated CAN interface up to 500 V<\/li>\n<li>Open CAN protocol for easy integration into existing control architectures<\/li>\n<li>Auto-TX\/RX mode for automatic processing of CAN packets<\/li>\n<\/ul>\n<h3>Digital inputs<\/h3>\n<ul>\n<li>Optocoupler inputs for AC\/DC signals<\/li>\n<li>Signal voltage range: \u00b115 V to \u00b130 V AC\/DC, optionally \u00b15 V to \u00b115 V AC\/DC<\/li>\n<li>Electrical isolation between input and output circuits up to 2.5 kV AC for 1 minute<\/li>\n<li>Maximum input current: 14 mA<\/li>\n<li>Adjustable input filter: 0 to 255 ms<\/li>\n<li>16-bit counter per channel with up to 65,535 count cycles<\/li>\n<li>Internal counting logic up to 10 kHz<\/li>\n<li>Flip-flop function for reliable detection of state changes between two readout operations<\/li>\n<\/ul>\n<h3>Digital outputs<\/h3>\n<ul>\n<li>Relay outputs with normally open (NO) contacts<\/li>\n<li>Relay type: SIL05-1A72D<\/li>\n<li>Max. switching voltage: 36 V AC\/DC<\/li>\n<li>Max. switching current: 0.5 A AC\/DC<\/li>\n<li>Max. conduction current: 1 A AC\/DC<\/li>\n<li>Max. switching power: 10 W<\/li>\n<li>Electrical isolation between contact and coil: 1.5 kV RMS \/ 1 minute<\/li>\n<\/ul>\n<h3>Additional features<\/h3>\n<ul>\n<li>Software-based timeout protection for the outputs<\/li>\n<li>Fail-safe mode for defined output states in the event of a connection failure<\/li>\n<li>LED indicator for each input and output channel<\/li>\n<li>Additional status indicators for operating voltage, interface activity, errors, and timeout<\/li>\n<li>Screwless, mis-plug-proof connectors from WAGO with locking mechanism<\/li>\n<\/ul>\n<h3>Mechanics and Environmental Conditions<\/h3>\n<ul>\n<li>Supply voltage: +12 V to +24 V DC<\/li>\n<li>Mounting on 35 x 7.5 mm DIN rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C<\/li>\n<li>Dimensions (16 I\/Os): 122 x 85 x 51.5 mm (H x W x D)<\/li>\n<li>Dimensions (32 I\/Os): 122 x 126 x 51.5 mm (H x W x D)<\/li>\n<li>Dimensions (64 I\/Os): 122 x 208 x 51.5 mm (H x W x D)<\/li>\n<\/ul>\n","protected":false},"featured_media":25587189,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1473,166],"product_tag":[],"class_list":{"0":"post-25568843","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-eingaenge","7":"einausgang-di16","8":"einausgang-digitale-ausgaenge","9":"einausgang-di32","10":"einausgang-do16","11":"einausgang-do32-en","12":"einausgang-di64","13":"einausgang-do64-en","14":"schnittstelle-can-en","15":"product_cat-raw-can-j1939","16":"product_cat-ro","17":"pa_anzahl-kanaele-di-do-64_di_do_ch_en","18":"pa_anzahl-kanaele-di-do-32_di_do_ch_en","19":"pa_anzahl-kanaele-di-do-16_di_do_ch_en","20":"pa_ausgaenge-do-art-relais-ausgaenge-1a_en","21":"pa_ausgaenge-do-art-mosfet-ausgaenge-2a_en","23":"first","24":"instock","25":"taxable","26":"shipping-taxable","27":"purchasable","28":"product-type-variable"},"acf":{"produktvergleich_rest_api":"","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square;\">\n<li><strong>Test benches and test systems<br \/>\n<\/strong>Optimal integration into test environments is enabled by the CAN interface of the RO-CAN-O16-64-R16-64, supporting analysis, simulation, and validation processes.:<\/li>\n<li><strong>Machine-to-machine communication (M2M)<br \/>\n<\/strong>Thanks to the integrated CAN M2M function of the RO-CAN-O16-64-R16-64, devices can communicate directly with each other. CAN telegrams are automatically transmitted between sender and receiver modules, allowing complete process chains to be controlled without a higher-level PLC or PC. Ideal for autonomous machine networks.:<\/li>\n<li><strong>Real-time communication on the CAN bus<br \/>\n<\/strong>Thanks to direct CAN transmission, data is exchanged in real time between system components without detours\u2014fast and deterministic.:<\/li>\n<li><strong>Energy and load management<br \/>\n<\/strong>The Modul enables targeted switching of loads and energy sources, for example in energy management systems, backup power solutions, or smart distribution networks.:<\/li>\n<li><strong>Research and development<br \/>\n<\/strong>Use in laboratories and test environments for scientific experiments and test setups.:<\/li>\n<li><strong>Safety-critical control systems (fail-safe)<br \/>\n<\/strong>The integrated fail-safe and timeout function of the RO-CAN-O16-64-R16-64 ensures that defined states are automatically maintained in the event of communication failures\u2014especially important for safety-critical applications.:<\/li>\n<li><strong>Industrial automation<br \/>\n<\/strong>It monitors digital signals from machines and production systems for precise control and process management.:<\/li>\n<li><strong>Laboratory automation<br \/>\n<\/strong>Digital signals from machines and production systems are reliably captured by the Modul and provided for precise process control.:<\/li>\n<li><strong>Mechanical engineering<br \/>\n<\/strong>Through the RO-CAN-O16-64-R16-64, galvanically isolated inputs can be directly integrated into machine control systems, ensuring high immunity to interference.:<\/li>\n<li><strong>Process monitoring<br \/>\n<\/strong>It delivers real-time data from production lines or test systems for continuous monitoring.:<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>&nbsp;<\/p>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>CAN interface:<\/h3>\n<ul>\n<li>CAN interface according to ISO 11898<\/li>\n<li>Open CAN protocol (RAW CAN)<\/li>\n<li>Automatic transmit\/receive mode<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Relay outputs 1 A:<\/h3>\n<ul>\n<li>Type: Normally Open (NO)<\/li>\n<li>Max. switching voltage: 36 V AC \/ DC<\/li>\n<li>Max. switching current: 0.5 A AC \/ DC<\/li>\n<li>Max. load current: 1 A AC \/ DC<\/li>\n<li>Max. switching power: 10 W<\/li>\n<li>Timeout protection function (configurable via software)<\/li>\n<li>Status LED for each output<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Digital inputs:<\/h3>\n<ul>\n<li>Type: AC\/DC optocoupler<\/li>\n<li>Signal level: \u00b15 V to \u00b115 V or \u00b115 V to \u00b130 V<\/li>\n<li>16-bit counter per channel (up to 100 Hz)<\/li>\n<li>Detects a transition from low to high and from high to low (flip-flop)<\/li>\n<li>Status LED for each channel<\/li>\n<\/ul>\n","produktvergleich":"<h2>Comparison of the RO-CAN-O16-64-R16-64 with standard products on the market<\/h2>\n<div class=\"g6g-respo-table\">\n<table style=\"width: 98.9925%; height: 1625px;\">\n<tbody>\n<tr class=\"table-headline-row\" style=\"height: 76px;\">\n<td style=\"width: 1105px; height: 76px;\" colspan=\"4\">\n<h3>Interfaces &amp; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\" style=\"height: 23px;\">\n<th style=\"color: #555555; width: 188px; height: 23px;\">Feature<\/th>\n<th style=\"color: #555555; width: 280px; height: 23px;\">Market Comparison<\/th>\n<th style=\"color: #555555; width: 343px; height: 23px;\">RO-CAN-O16-64-R16-64<\/th>\n<th style=\"color: #555555; width: 294px; height: 23px;\">Practical benefits<\/th>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>Openness of proceedings<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">For many standard modules, the telegram structure or integration is specific to the manufacturer.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Open CAN protocol for seamless integration into existing CAN architectures.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Facilitates integration into existing control systems, gateways, and CAN networks.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>CAN Standards and Bit Rates<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Supported CAN parameters are often limited or less clearly specified.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Supports CAN 2.0A \/ 2.0B as well as bit rates ranging from 10 kbit\/s to 1 Mbit\/s.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Offers greater flexibility when integrating into various CAN systems and existing installations.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>Automatic Telegram Processing<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Recurring CAN telegrams often need to be processed by external control logic.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Auto TX\/RX Mode for automatic processing of CAN packets.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Reduces the implementation effort in the controller and simplifies recurring communication tasks.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\" style=\"height: 76px;\">\n<td style=\"width: 1105px; height: 76px;\" colspan=\"4\">\n<h3>Digital inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\" style=\"height: 23px;\">\n<th style=\"width: 188px; height: 23px;\">Feature<\/th>\n<th style=\"width: 280px; height: 23px;\">Market Comparison<\/th>\n<th style=\"width: 343px; height: 23px;\">RO-CAN-O16-64-R16-64<\/th>\n<th style=\"width: 294px; height: 23px;\">Practical benefits<\/th>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>Signal isolation of the inputs<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">In some cases, without galvanic isolation or with reduced protection between the field side and the logic side.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Electrically isolated optocoupler inputs with isolation up to 2.5 kV AC for 1 minute.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Improves operational reliability when acquiring external switch and sensor signals.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 188px; height: 47px;\" data-label=\"Merkmal\"><strong>Input filter<\/strong><\/td>\n<td style=\"width: 280px; height: 47px;\" data-label=\"Marktvergleich\">Filter functions are often predefined or can only be configured to a limited extent.<\/td>\n<td style=\"width: 343px; height: 47px;\" data-label=\"RO-CAN-O16-64-R16-64\">Programmable filter for input state changes and counter functions.<\/td>\n<td style=\"width: 294px; height: 47px;\" data-label=\"Praxisnutzen\">Reduces bounce and improves the reliable detection of actual switching signals.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 188px; height: 47px;\" data-label=\"Merkmal\"><strong>Counter function per channel<\/strong><\/td>\n<td style=\"width: 280px; height: 47px;\" data-label=\"Marktvergleich\">Often just a simple status check or a global counter function.<\/td>\n<td style=\"width: 343px; height: 47px;\" data-label=\"RO-CAN-O16-64-R16-64\">16-bit counter per channel with up to 65,535 counts.<\/td>\n<td style=\"width: 294px; height: 47px;\" data-label=\"Praxisnutzen\">Allows for the direct capture of pulses and events without additional hardware.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 188px; height: 47px;\" data-label=\"Merkmal\"><strong>Pulse detection<\/strong><\/td>\n<td style=\"width: 280px; height: 47px;\" data-label=\"Marktvergleich\">Faster signal changes are not always recorded or analyzed separately.<\/td>\n<td style=\"width: 343px; height: 47px;\" data-label=\"RO-CAN-O16-64-R16-64\">Internal counting logic up to 10 kHz for capturing fast signal sequences.<\/td>\n<td style=\"width: 294px; height: 47px;\" data-label=\"Praxisnutzen\">Suitable for applications involving high-speed clock or pulse signals in the field.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>Detection of state changes<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Signal changes between two read cycles are sometimes lost in standard modules.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">IInternal flip-flops detect transitions from low to high and from high to low between two read operations.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Improves event detection for short signal transitions and asynchronous state changes.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 188px; height: 47px;\" data-label=\"Merkmal\"><strong>Status Indicator<\/strong><\/td>\n<td style=\"width: 280px; height: 47px;\" data-label=\"Marktvergleich\">Channel statuses are often only partially visible or displayed in aggregate form.<\/td>\n<td style=\"width: 343px; height: 47px;\" data-label=\"RO-CAN-O16-64-R16-64\">LED status indicator for each input and output channel for quick visual inspection.<\/td>\n<td style=\"width: 294px; height: 47px;\" data-label=\"Praxisnutzen\">Speeds up diagnosis, commissioning, and troubleshooting directly on the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\" style=\"height: 76px;\">\n<td style=\"width: 1105px; height: 76px;\" colspan=\"4\">\n<h3>Relay Outputs &amp; Operational Safety<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\" style=\"height: 23px;\">\n<th style=\"width: 188px; height: 23px;\">Feature<\/th>\n<th style=\"width: 280px; height: 23px;\">Market Comparison<\/th>\n<th style=\"width: 343px; height: 23px;\">RO-CAN-O16-64-R16-64<\/th>\n<th style=\"width: 294px; height: 23px;\">Practical benefits<\/th>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>Output type<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Standard outputs are often grouped together without specifying their relay characteristics in detail.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Relay outputs with normally open (NO) contacts for standard industrial switching applications.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Suitable for reliably switching external loads in typical industrial applications.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>Switching parameters<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Trigger levels are not always reported in a way that allows for a complete or direct comparison with the market.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Clear relay data with up to 36 V AC\/DC, 0.5 A switching current, 1 A continuous current, and 10 W switching capacity.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Facilitates the technical evaluation and proper sizing for the specific load.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\"><strong>Electrical isolation of the relays<\/strong><\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">The electrical isolation between the contact and the coil is not always explicitly mentioned.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Electrical isolation between the contact and the coil rated at 1.5 kV RMS for 1 minute.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Supports a safe isolation between the control circuit and the load circuit.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 188px; height: 47px;\" data-label=\"Merkmal\"><strong>Safe initial states<\/strong><\/td>\n<td style=\"width: 280px; height: 47px;\" data-label=\"Marktvergleich\">Timeout or fail-safe functions are not included in every product class.<\/td>\n<td style=\"width: 343px; height: 47px;\" data-label=\"RO-CAN-O16-64-R16-64\">Timeout protection and fail-safe mode for specific conditions in the event of a connection failure.<\/td>\n<td style=\"width: 294px; height: 47px;\" data-label=\"Praxisnutzen\">Prevents undefined switching states and enhances operational safety in the event of a fault.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\" style=\"height: 76px;\">\n<td style=\"width: 1105px; height: 76px;\" colspan=\"4\">\n<h3>Integration, Installation &amp; Practical Application<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\" style=\"height: 23px;\">\n<th style=\"width: 188px; height: 23px;\">Feature<\/th>\n<th style=\"width: 280px; height: 23px;\">Market Comparison<\/th>\n<th style=\"width: 343px; height: 23px;\">RO-CAN-O16-64-R16-64<\/th>\n<th style=\"width: 294px; height: 23px;\">Practical benefits<\/th>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\">Wide variety<\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Often, only a few fixed I\/O combinations are available per module.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Models with 16, 32, or 64 digital inputs and outputs within the same product family.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Makes it easier to select the right module sizes for small to large I\/O tasks.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\">Supply voltage<\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">The coverage areas vary, sometimes significantly, depending on the model and series.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Rated for +12 V to +24 V DC, making it suitable for many industrial 24-V environments.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Simplifies installation in typical industrial setups and existing utility systems.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\">Assembly<\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Mounting on a 35 x 7.5 mm top-hat rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\">Connection plan<\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Connection solutions are not always designed for quick wiring and reverse-polarity protection.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Screwless, mis-insertion-protected WAGO connectors with a locking mechanism.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Simplifies wiring, maintenance, and secure connections in ongoing projects.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 188px; height: 71px;\" data-label=\"Merkmal\">Environmental data<\/td>\n<td style=\"width: 280px; height: 71px;\" data-label=\"Marktvergleich\">Practical information regarding operating conditions is sometimes poorly documented.<\/td>\n<td style=\"width: 343px; height: 71px;\" data-label=\"RO-CAN-O16-64-R16-64\">Operating temperature range of +10 \u00b0C to +50 \u00b0C for typical industrial applications.<\/td>\n<td style=\"width: 294px; height: 71px;\" data-label=\"Praxisnutzen\">Provides designers and users with clear guidance on the intended application.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","produktbeschreibung_rest_api":"","sge_text":"<p>The RO-CAN CAN I\/O module from DEDITEC is an industrial CAN bus remote I\/O module with 16, 32, or 64 digital inputs and outputs. It features galvanic isolation via optocouplers and operates on a supply voltage of 12 to 24 V DC. The module is ideal for industrial automation, mechanical engineering, and control technology, and enables the reliable integration of digital signals into decentralized I\/O modules within CAN-based systems.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","zusatztext":"<h2>Typical applications for the RO-CAN CAN I\/O module<\/h2>\n<p>The RO-CAN-DI\/DO-REL is suitable for industrial applications where digital signals need to be reliably acquired and external loads controlled via the CAN bus. Thanks to its electrically isolated optocoupler inputs, relay outputs, and robust CAN interface, the module is particularly well-suited for decentralized I\/O tasks in machines, control cabinets, test benches, and distributed automation systems.<\/p>\n<h3>Suitable for<\/h3>\n<ul>\n<li>Machine and Plant Engineering<\/li>\n<li>Control Panel Construction and Industrial Control Technology<\/li>\n<li>Test Benches and Test Systems<\/li>\n<li>Decentralized CAN I\/O Structures<\/li>\n<li>Custom Machines and Technical Automation Solutions<\/li>\n<li>CAN-Based Control and Diagnostic Systems<\/li>\n<\/ul>\n<h3>Typical applications<\/h3>\n<ul>\n<li>Detection of switching states, limit switches, and sensor signals<\/li>\n<li>Control of indicator lights, valves, relays, and external loads<\/li>\n<li>Integration of digital input and output signals into existing CAN networks<\/li>\n<li>Decentralized signal processing in distributed automation systems<\/li>\n<li>Monitoring and switching control in machines and test systems<\/li>\n<li>Transmission of status and switching signals to higher-level CAN controllers<\/li>\n<\/ul>\n<h3>Typical signaling and switching tasks<\/h3>\n<ul>\n<li>Monitoring of digital input signals with galvanic isolation<\/li>\n<li>Switching of potential-free relay outputs for industrial loads<\/li>\n<li>Status detection with input filtering and counting function<\/li>\n<li>Safe output shutdown via timeout and fail-safe functions<\/li>\n<li>Implementation of distributed switching tasks in CAN-based automation environments<\/li>\n<\/ul>\n","faq_rest_api":""},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25568843","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568843"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25587189"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568843"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25568843"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25568843"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25568843"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}