{"id":25568818,"date":"2019-11-28T14:12:26","date_gmt":"2019-11-28T13:12:26","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/can-counter-modul-mit-8-eingangszaehlern-und-2-ausgangszaehlern\/"},"modified":"2026-08-14T16:02:50","modified_gmt":"2026-08-14T14:02:50","slug":"can-counter-module-megahertz-range","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/ro\/raw-can-j1939\/can-counter-module-megahertz-range\/","title":{"rendered":"CAN counter module with megahertz range * CAN counter module with 8 input counters and 2 output counters"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25585843,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1473,166],"product_tag":[],"class_list":{"0":"post-25568818","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-counter","7":"schnittstelle-can-en","8":"product_cat-raw-can-j1939","9":"product_cat-ro","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"purchasable","16":"product-type-simple"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of RO-CAN-CNT8 with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Protocol transparency<\/strong><\/td>\n<td data-label=\"Market Comparison\">For many standard modules, the telegram structure or integration is manufacturer-specific.<\/td>\n<td data-label=\"RO-CAN-CNT8\">Open CAN protocol for seamless integration into existing CAN architectures.<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Facilitates integration into existing controllers, gateways, and CAN networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automatic telegram processing<\/strong><\/td>\n<td data-label=\"Market Comparison\">Recurring CAN telegrams often have to be processed using external control logic.<\/td>\n<td data-label=\"RO-CAN-CNT8\">Auto TX\/RX mode for automatic processing of CAN packets.<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Reduces the implementation effort in the controller and simplifies recurring communication tasks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>CAN standards and bit rates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Supported CAN parameters are often limited or less clearly specified.<\/td>\n<td data-label=\"RO-CAN-CNT8\">Supports CAN 2.0A \/ 2.0B and bit rates from 10 kbit\/s to 1 Mbit\/s.<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Offers greater flexibility when integrating into different CAN systems and existing installations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Interfaces<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only USB or PCI<\/td>\n<td data-label=\"RO-CAN-CNT8\">USB, Ethernet and web interface<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Enables flexible connectivity options in various IT and industrial environments.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"RO-CAN-CNT8\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Number of counter channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">1\u20134 Input Counters<\/td>\n<td data-label=\"RO-CAN-CNT8\">8 input counters (48-bit), up to 20 MHz<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Captures pulses in parallel and enables the analysis of high-speed signals without additional counter hardware<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Signal isolation of the inputs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes without galvanic isolation or with reduced protection between the field and logic sides.<\/td>\n<td data-label=\"RO-CAN-CNT8\">Electrically isolated optocoupler inputs for safe signal operation<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Increases operational reliability when detecting external switching and sensor signals.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"RO-CAN-CNT8\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"RO-CAN-CNT8\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Add modules later<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only a fixed number of I\/Os per module<\/td>\n<td data-label=\"RO-CAN-CNT8\">Additional I\/O modules can be added freely<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Enables step-by-step system expansion without replacing existing hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Form factor<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one standard housing available<\/td>\n<td data-label=\"RO-CAN-CNT8\">Large selection of module variants<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Allows for application-specific selection and facilitates integration into various installation scenarios.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"RO-CAN-CNT8\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"RO-CAN-CNT8\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"RO-CAN-CNT8\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"RO-CAN-CNT8\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"RO-CAN-CNT8\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-CAN-CNT8\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"RO-CAN-CNT8\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"RO-CAN-CNT8\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"RO-CAN-CNT8\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"RO-CAN-CNT8\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"RO-CAN-CNT8\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"RO-CAN-CNT8\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"RO-CAN-CNT8\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"RO-CAN-CNT8\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"RO-CAN-CNT8\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"RO-CAN-CNT8\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"RO-CAN-CNT8\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series maturity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many products are new or frequently revised<\/td>\n<td data-label=\"RO-CAN-CNT8\">Series with 15+ years of history<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Offers a proven platform with stable firmware and mature hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"RO-CAN-CNT8\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"RO-CAN-CNT8\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"RO-CAN-CNT8\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"RO-CAN-CNT8\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"RO-CAN-CNT8\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"RO-CAN-CNT8\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC RO-CAN-CNT8<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN counter modules with megahertz range<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"RO-CAN-CNT8\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"RO-CAN-CNT8\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"RO-CAN-CNT8\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the CAN counter modules with megahertz range\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Test benches and test systems:<br \/><\/strong>Optimal integration into test environments is enabled by the CAN interface of the RO-CAN-CNT8, supporting analysis, simulation, and validation processes.<\/li>\n<li><strong>Real-time communication on the CAN bus:<br \/><\/strong>Direct CAN communication via RAW CAN or J1939 enables data to be transmitted between system components without intermediate processing \u2013 quickly, efficiently, and with deterministic transmission behavior.<\/li>\n<li><strong>Counter data acquisition in SCADA:<br \/><\/strong>Network integration for centralized process monitoring and data logging.<\/li>\n<li><strong>Machine control:<br \/><\/strong>With the RO-CAN-CNT8, real-time counter values are available for position and status evaluation in motion control systems.<\/li>\n<li><strong>Test and measurement systems:<br \/><\/strong>Generation and measurement of pulses for diagnostics and quality control.<\/li>\n<li><strong>Fault signal detection &#038; condition monitoring:<br \/><\/strong>Reliable acquisition of digital states in distributed systems.<\/li>\n<\/ul>\n","produktbeschreibung_rest_api":"<section class=\"product-description product-description-RO-CAN-CNT8\">\n<h2>Product Description \u2013 CAN counter module with megahertz range<\/h2>\n<p>The RO-CAN-CNT8 is an industrial CAN bus I\/O system for highly precise acquisition and generation of pulse signals. It features 8 independent counter inputs with a maximum input frequency of up to 20 MHz and 48-bit resolution, enabling reliable processing of fast and high-resolution counting tasks. The inputs are galvanically isolated up to 3.75 kV AC and support input voltages typically in the range of 15\u201330 V DC (optionally 5\u201315 V DC), allowing flexible integration of industrial sensor systems.<br \/>\nIn addition, the module provides 2 pulse outputs with a maximum frequency of up to 5 MHz, also operating with 48-bit resolution and used for generating precise clock signals or control pulses. The output stage delivers 5 V at up to 25 mA and is galvanically isolated from the supply system.<br \/>\nCommunication is carried out via CAN 2.0A\/2.0B using RAW CAN or J1939, or optionally via Auto TX\/RX mode for direct data exchange within the network. Via USB or CAN, the CAN counter module with megahertz range can be parameterized, monitored, and commissioned.<br \/>\nVarious counting modes allow not only classical pulse counting but also frequency, period, and PWM measurements, making the module highly versatile.<\/p>\n<h3>CAN interface with flexible USB configuration<\/h3>\n<p>The CAN interface of the RO-CAN-CNT8 is based on the CAN 2.0A\/B standard and enables robust, error-resistant communication via RAW CAN or J1939 in industrial networks. It supports the typical multi-master CAN bus architecture, allowing multiple nodes to efficiently exchange data without a central controller. The bit rate is flexibly configurable, enabling the CAN counter module with megahertz range to be easily adapted to different network speeds and system environments. Communication is handled via standardized CAN telegrams with event-driven data transmission for fast and reliable signal processing.<br \/>\nThe entire CAN configuration, including TX\/RX behavior, is conveniently carried out via the integrated USB interface on a PC. This allows parameters such as bus speed and message handling to be quickly configured and tested. This combination of CAN and USB connectivity significantly simplifies commissioning and reduces integration and diagnostic effort.<\/p>\n<h3>Flexible CAN control via auto TX\/RX and DELIB command mode<\/h3>\n<p>The RO-CAN-CNT8 can generally be controlled using two operating modes: Auto TX\/RX mode and DELIB command mode. In Auto TX\/RX mode, the module can automatically transmit and receive CAN packets without requiring a permanently connected control PC. Both RAW CAN and J1939 are supported.<br \/>\nAlternatively, DELIB command mode provides direct register-based access via a manufacturer-specific CAN protocol, allowing specific commands to be transmitted to the CAN counter module with megahertz range. Read and write operations are implemented using defined CAN IDs and structured data packets, enabling highly flexible and precise control.<br \/>\nThese control modes can be conveniently configured on a PC via the integrated USB interface. The corresponding tool allows parameters such as communication behavior, TX\/RX logic and the DELIB command structure to be easily configured and tested. This enables the CAN counter module with megahertz range to be quickly adapted to different applications and efficiently integrated into existing CAN systems.<\/p>\n<h3>Powerful I\/Os for precise counting and pulse processing<\/h3>\n<p>The I\/O functionality of the RO-CAN-CNT8 is specifically designed for precise counting and pulse processing tasks, combining powerful input and output channels in a single system. The counter inputs operate at frequencies of up to 20 MHz with 48-bit resolution, enabling reliable acquisition of even very fast and fine pulse sequences.<br \/>\nIn addition, the CAN counter module with megahertz range provides pulse outputs capable of generating signals up to 5 MHz, which can be flexibly configured\u2014for example in terms of pulse count as well as high and low times with very fine resolution.<br \/>\nWith integrated PWM functions and various operating modes such as pulse counting or period measurement, the I\/Os can be adapted to a wide range of measurement and control tasks.<br \/>\nGalvanic isolation of the channels and individually configurable filters also ensure high noise immunity and reliable signal processing in industrial environments.<\/p>\n<h3>M2M communication \u2013 direct device-to-device networking<\/h3>\n<p>The M2M (machine-to-machine) function enables direct communication between multiple modules or systems without a central control unit. States and events can be automatically exchanged and synchronized between devices, allowing the creation of distributed and autonomously operating automation structures. Communication is carried out via defined protocols and can be flexibly integrated into existing system architectures. As a result, M2M is particularly well suited for connected industrial and IoT applications.<\/p>\n<h3>Form factor and connectors<\/h3>\n<p>The CAN counter module with megahertz range is designed for demanding industrial use and features a robust construction. Its housing is shock-resistant and vibration-proof, making it suitable for installation in control cabinets and on DIN rail mounting systems.<br \/>\nThe I\/Os of the RO-CAN-CNT8 are wired via WAGO connectors, providing a secure, vibration-resistant connection. The module supports an operating temperature range from -20 \u00b0C to +60 \u00b0C and is designed for continuous operation under industrial conditions.<br \/>\nThanks to these features, it offers high reliability, a long service life, and easy maintenance, making it ideal for automation, mechanical engineering, and laboratory control applications.<\/p>\n<h3>Maintenance and Long-Term Planning<\/h3>\n<p>The RO-CAN-CNT8 supports users with a durable, industrial-grade architecture that enables predictable use over many years. The combination of robust drivers, comprehensive documentation, and the ICT diagnostic tool simplifies commissioning and maintenance. Electrical isolation and high-quality electronics ensure reliable operation, while support and continuous updates guarantee seamless integration into professional automation environments.<br \/>\n<br \/>\n<\/section>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The RO-CAN-CNT8 integrates 8 galvanically isolated 48-bit counter inputs with a maximum input frequency of 20 MHz, as well as 2 pulse generator outputs up to 5 MHz, into a CAN I\/O module with an open CAN 2.0A\/B protocol. It supports various counting and PWM measurement modes, configurable filter functions, and an automatic TX\/RX mode for standalone CAN communication. The module is suitable for high-precision frequency, pulse, and speed measurements in test benches, machine controls, and industrial automation systems.<br \/>\n<\/p>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>CAN interface:<\/h3>\n<ul>\n<li>CAN interface according to ISO 11898<\/li>\n<li>Open CAN protocol<\/li>\n<li>RAW CAN\/J1939<\/li>\n<li>Automatic transmit\/receive mode<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Temperature inputs:<\/h3>\n<ul>\n<li>8 channels per unit<\/li>\n<li>Max. counting frequency: 20 MHz<\/li>\n<li>Resolution: 48-bit<\/li>\n<li>Max. input voltage: 15 V DC to 30 V DC (optional 5 V to 15 V DC)<\/li>\n<li>Max. input current: 14 mA<\/li>\n<li>Galvanic isolation of inputs: 3.75 kV AC \/ 1 min<\/li>\n<li>Input filter per channel (configurable via software)<\/li>\n<li>Pulse counting, period determination, frequency measurement, PWM measurement<\/li>\n<li>2 channels per unit<\/li>\n<li>Max. frequency: 5 MHz<\/li>\n<li>Resolution: 48-bit<\/li>\n<li>Output power: 5 V \/ 25 mA<\/li>\n<li>Electrical isolation from the module&#8217;s power supply: 1 kV<\/li>\n<li>Number of pulses to be generated: adjustable (0 = infinite)<\/li>\n<li>Low-time setting (10 ns steps)<\/li>\n<li>High-time setting (10 ns steps)<\/li>\n<li>0.5 kHz \u2013 Frequency PWM ratio with 0.01% resolution<\/li>\n<li>5 kHz \u2013 Frequency PWM ratio with 0.1% resolution<\/li>\n<li>50 kHz \u2013 Frequency PWM ratio with 1% resolution<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","sge_text":"<p>The RO-CAN-CNT8 is a powerful CAN counter module for industrial applications in the megahertz range. It provides eight high-precision input counters with up to 20 MHz as well as two output channels for pulse and frequency signals up to 5 MHz. Thanks to galvanic isolation and an open CAN protocol, the module is ideally suited for automation and measurement systems. Its flexible configuration enables a wide range of counting and frequency measurement tasks in the megahertz range, making it perfect for demanding industrial environments.<br \/>\nThrough the integrated CAN interface, the module can be easily integrated into existing networks and configured using the ICT-Tool.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW CAN THE CAN BAUD RATE AND OTHER MODULE CONFIGURATIONS BE SET?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The configuration can be performed using the ICT-Tool. Depending on the module variant, the connection to the ICT-Tool is established via the USB or Ethernet interface. In the \"Configuration\" menu, the desired CAN baud rate can be selected and permanently stored in the module.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW CAN THE MODULES BE CONFIGURED, TESTED, AND UPDATED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Configuration, diagnostics, and commissioning are conveniently performed using the DEDITEC ICT-Tool. It also allows functions to be tested and firmware updates to be carried out.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN PYTHON?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, we provide a comprehensive example package. It contains ready-made Python programming examples that allow you to quickly integrate our modules into your application.\nIn addition, you will also find examples for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT THE AVAILABLE INTERFACES AND FUNCTIONS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete description of the supported interfaces, communication options, and device functions can be found in the module manual. It is available at any time via the \"Downloads and Manuals\" tab on the respective product page as well as in the download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND AN OVERVIEW OF ALL AVAILABLE API COMMANDS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete overview of all supported API commands can be found in the manual of the respective module. In addition, the API documentation is available on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25568818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568818"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25585843"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568818"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25568818"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25568818"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25568818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}