{"id":25568737,"date":"2019-11-08T10:14:56","date_gmt":"2019-11-08T09:14:56","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/cos-da2-iso\/"},"modified":"2026-09-14T10:04:32","modified_gmt":"2026-09-14T08:04:32","slug":"canopen-da-voltage-output-module-2-channels-16-bit-da","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/canopen\/canopen-da-voltage-output-module-2-channels-16-bit-da\/","title":{"rendered":"CANopen D\/A voltage output module * CANopen module with 2 analog outputs &#8211; 16-bit D\/A converter with galvanic isolation"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25584087,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1581,245],"product_tag":[],"class_list":{"0":"post-25568737","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ao2","7":"einausgang-analoge-ausgaenge","8":"schnittstelle-canopen-en","9":"product_cat-canopen","10":"product_cat-uc","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"purchasable","17":"product-type-simple"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-CANOPEN-DA2-16ISO with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CANopen D\/A modules for voltage outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CANopen D\/A modules for voltage outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Analog voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Basic analog outputs, often only 0\u20135 V or 0\u201310 V<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Precise voltage output over 0\u20135 V, 0\u201310 V or \u00b110 V<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Enables precise control of various actuators and reduces the need for external signal converters.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Current and voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some providers offer only voltage or only current<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Both signal types supported<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Increases compatibility with various industrial and process signals and simplifies integration into existing systems.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Low output ripple<\/strong><\/td>\n<td data-label=\"Market Comparison\">Stronger ripple in OEM modules<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Low ripple and stable output signals<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Improves signal quality and ensures stable output values in sensitive control and regulation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Protects connected devices from interference voltages and prevents feedback between the output stage and the power supply.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation between all channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often a common reference potential for all channels<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Galvanic isolation up to 500 V between all channels<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Enables operation in systems with different reference potentials and prevents compensation currents between channels.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CANopen D\/A modules for voltage outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CANopen D\/A modules for voltage outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CANopen D\/A modules for voltage outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CANopen D\/A modules for voltage outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CANopen D\/A modules for voltage outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CANOPEN-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CANopen D\/A modules for voltage outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-CANOPEN-DA2-16ISO\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the CANopen D\/A modules for voltage outputs\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Standardized automation networks (CiA 301\/401):<br \/><\/strong>The CANopen D\/A modules for voltage outputs is ideally suited for standards-based CANopen networks in industrial applications. Thanks to support for established CiA profiles, it can be seamlessly integrated into existing automation systems.<\/li>\n<li><strong>Decentralized machine control in a CANopen network:<br \/><\/strong>In CANopen structures, the UC-CANOPEN-DA2-16ISO can act as an intelligent network participant and support synchronized processes with other nodes in machines and systems.<\/li>\n<li><strong>System networking in industrial production:<br \/><\/strong>Perfect for structured networking of multiple machines or plant sections via CANopen. This enables scalable and modularly expandable production systems.<\/li>\n<li><strong>Synchronized real-time process communication:<br \/><\/strong>CANopen enables deterministic communication between multiple participants. This makes the CANopen D\/A module for voltage outputs suitable for time-critical control and synchronization tasks within the system network.<\/li>\n<li><strong>Diagnostics and network management in CANopen systems:<br \/><\/strong>By integrating into CANopen structures, the CANopen D\/A module for voltage outputs can also contribute to network diagnostics and monitoring of communication states within the overall system.<\/li>\n<li><strong>Labor and testing technology:<br \/><\/strong>The CANopen D\/A modules for voltage outputs is ideally suited for experimental setups, data acquisition, and calibrations where high precision and reliability are essential.<\/li>\n<li><strong>Test systems:<br \/><\/strong>Flexible control of individual channels supports simulations and repeatable test procedures.<\/li>\n<li><strong>Automated test benches:<br \/><\/strong>Precise D\/A signal control for test and validation environments.<\/li>\n<li><strong>Laboratory and measurement systems:<br \/><\/strong>For measurement and control tasks, the UC-CANOPEN-DA2-16ISO provides high-resolution analog outputs.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The module provides two high-resolution 16-bit D\/A channels for the precise output of analog voltage and current signals and supports various output ranges for flexible applications. Electrical isolation ensures high operational reliability, while CANopen integration according to the CiA standard enables reliable integration into industrial networks. Typical applications include the control of analog actuators and the output of defined control signals in automation and test bench systems.<br \/>\n<\/p>\n<h3>CANopen interface:<\/h3>\n<ul>\n<li>CANopen profiles according to CiA\u00ae specifications CiA 301, CiA 305, and CiA 401<\/li>\n<li>CAN 2.0A or CAN 2.0B<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<li>Configurable via DIP switches<\/li>\n<li>1 Mbit\/s, 800 Kbit\/s, 500 Kbit\/s, 250 Kbit\/s, 125 Kbit\/s, 100 Kbit\/s, 50 Kbit\/s, 20 Kbit\/s, 10 Kbit\/s, auto baud<\/li>\n<\/ul>\n<h3>Analog outputs:<\/h3>\n<ul>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V<\/li>\n<li>Current ranges: 0\u201320 mA, 4\u201320 mA, 0\u201324 mA<\/li>\n<li>Channel-to-channel isolation: max. 1 kV AC<\/li>\n<li>Isolation from power supply: max. 500 V AC<\/li>\n<li>Load resistance: \u2265 1 k\u03a9<\/li>\n<li>All D\/A channels are galvanically isolated from one another<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-CANOPEN-DA2-16ISO\">\n<h2>Product Description \u2013 CANopen D\/A module for voltage outputs<\/h2>\n<p>The UC-CANopen-DA2-16ISO is a high-performance DA voltage output module designed to provide precise and interference-free analog signals in industrial applications. With two high-resolution 16-bit D\/A channels, it enables the precise output of voltage and current signals in various ranges, including 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V, as well as 0\u201320 mA and 4\u201320 mA. The fully galvanically isolated channels ensure maximum operational reliability, prevent ground loops, and protect connected systems from interference\u2014a decisive advantage in complex automation environments.<br \/>\nThanks to support for CANopen profiles according to CiA 301, 305, and 401, the CANopen D\/A module for voltage outputs can be flexibly integrated into existing CAN networks. Configuration is conveniently performed via rotary coding switches. The robust design, high-quality WAGO connector technology, and simple integration via the DIN rail bus make the UC-CANopen-DA2-16ISO a reliable choice for long-term industrial projects.<br \/>\nTypical applications include the precise control of valves, actuators, or other analog actuators, as well as the output of defined process and test signals in automation, manufacturing, and test systems.<\/p>\n<h3>Standardized CANopen communication for industrial automation networks<\/h3>\n<p>The CANopen interface of the UC-CANOPEN-DA2-16ISO is based on the internationally established CiA\u00ae specifications 301, 305, and 401 and enables reliable and standardized integration into industrial fieldbus environments. By supporting CAN 2.0A and CAN 2.0B, a high level of compatibility with a wide range of control and automation systems is ensured. Galvanic isolation of the bus connection provides robust signal transmission and reliably protects communication against interference in harsh industrial environments. Device addressing is conveniently carried out via integrated rotary coding switches, allowing the node ID to be set directly on the device at hardware level, which enables fast commissioning without additional configuration software. In addition, the baud rate can be flexibly adapted to the respective network, ensuring easy integration into existing system architectures. Furthermore, the interface on the module supports data rates of up to 1 Mbit\/s as well as features such as auto-baud detection to further simplify commissioning. This results in a powerful, stable, and standards-compliant communication solution that supports both fast installation and reliable operation in industrial environments.<\/p>\n<h3>Flexible control via CANopen for easy system integration<\/h3>\n<p>The control of the UC-CANOPEN-DA2-16ISO is fully based on the standardized CANopen protocol, enabling seamless integration into existing automation and control systems. By supporting the object-oriented communication model according to CiA 301, all functions are addressed and controlled via the Object Dictionary. Configuration is conveniently performed using standardized communication objects such as SDOs, while cyclic process data exchange via PDOs ensures fast and deterministic response in real-time operation.<br \/>\nIn addition, the CANopen D\/A module for voltage outputs supports typical CANopen Network Management (NMT) functions, enabling defined start, stop, and error states of the device within the network. Flexible assignment of node ID and baud rate simplifies adaptation to different network topologies and control environments. Thanks to this consistent implementation of the CANopen standard, the module can be efficiently integrated into existing automation architectures and centrally operated via the control system.<\/p>\n<h3>Precise analog outputs for demanding control and regulation applications<\/h3>\n<p>The CANopen D\/A module for voltage outputs features analog outputs with 16-bit resolution, enabling very fine and highly reproducible signal generation. Supported voltage ranges include 0\u20135 V, 0\u201310 V, as well as \u00b15 V and \u00b110 V, allowing flexible adaptation to different industrial actuators. The outputs offer high accuracy, low drift, and stable long-term performance, even during continuous operation.<br \/>\nWith short response times, the system is also well suited for dynamic control processes and rapid setpoint changes. Overall, the UC-CANOPEN-DA2-16ISO is ideal for precise control and regulation tasks in demanding industrial environments.<\/p>\n<h3>Compact DIN rail design with modular system integration<\/h3>\n<p>Das CANopen D\/A module for voltage outputs ist f\u00fcr die Montage auf der DIN-Hutschiene ausgelegt und verf\u00fcgt \u00fcber ein kompaktes, industrietaugliches Geh\u00e4use, das auf den Einsatz in rauen Automatisierungsumgebungen optimiert ist. Die elektrischen Anschl\u00fcsse sind \u00fcber robuste, steckbare Klemmsysteme realisiert, die eine vibrationssichere Verdrahtung und eine schnelle Installation erm\u00f6glichen. Ein zentrales Merkmal ist der integrierte T-Bus, der als interner Systembus sowohl die Kommunikation als auch die Versorgungsspannung zwischen mehreren Modulen ohne zus\u00e4tzliche Verdrahtung durchreicht. Dadurch entsteht eine durchg\u00e4ngige Backplane-Struktur, bei der Module mechanisch auf der Hutschiene verbunden und elektrisch automatisch gekoppelt werden. Der T-Bus reduziert den Verkabelungsaufwand erheblich und sorgt gleichzeitig f\u00fcr eine saubere, EMV-optimierte Systemarchitektur mit geringem St\u00f6rpotenzial. \u00dcber die modulare Steckmechanik lassen sich weitere Teilnehmer einfach erg\u00e4nzen, ohne das bestehende System neu verdrahten zu m\u00fcssen. Die CANopen-Kommunikation des UC-CANOPEN-DA2-16ISO wird dabei nahtlos in diese T-Bus-Struktur eingebettet, wodurch eine skalierbare und systematisch aufgebaute Netzwerktopologie entsteht.<br \/>\nZus\u00e4tzlich verf\u00fcgt das CANopen D\/A module for voltage outputs \u00fcber integrierte Drehkodierschalter zur schnellen und einfachen Parametrierung direkt am Ger\u00e4t. \u00dcber diese lassen sich zentrale Einstellungen wie beispielsweise die Node-ID ohne Softwarezugriff konfigurieren. Dies erm\u00f6glicht eine besonders schnelle Inbetriebnahme sowie eine eindeutige Ger\u00e4teadressierung im Feld. Die Einstellung erfolgt dabei robust und manipulationssicher, auch im spannungslosen Zustand.<\/p>\n<h3>Maintenance and Long-Term Planning<\/h3>\n<p>The UC-CANOPEN-DA2-16ISO supports users with a durable, industrial-grade architecture that enables predictable use over many years. The combination of robust drivers, comprehensive documentation, and the ICT diagnostic tool simplifies commissioning and maintenance. Electrical isolation and high-quality electronics ensure reliable operation, while support and continuous updates guarantee seamless integration into professional automation environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW ARE INPUTS AND OUTPUTS MAPPED IN CANOPEN?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>I\/O states are provided via defined objects in the device profile (CiA 401). These can be transmitted cyclically via PDOs or selectively queried or set via SDOs.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT THE AVAILABLE INTERFACES AND FUNCTIONS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete description of the supported interfaces, communication options, and device functions can be found in the module manual. It is available at any time via the \"Downloads and Manuals\" tab on the respective product page as well as in the download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25568737","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568737"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584087"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568737"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25568737"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25568737"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25568737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}