{"id":25568580,"date":"2019-11-08T08:28:29","date_gmt":"2019-11-08T07:28:29","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/net-dev-o16\/"},"modified":"2026-08-14T15:59:49","modified_gmt":"2026-08-14T13:59:49","slug":"distributed-data-acquisition-plc-with-24-v-inputs-net-dev-o16","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/net-serie\/distributed-data-acquisition-plc-with-24-v-inputs-net-dev-o16\/","title":{"rendered":"distributed data acquisition PLC with 24 V inputs &#8211; NET-DEV module with 16 optocoupler inputs"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25584632,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[201],"product_tag":[],"class_list":{"0":"post-25568580","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-eingaenge","7":"einausgang-di16","8":"schnittstelle-ethernet-en","9":"schnittstelle-usb-en","10":"schnittstelle-can-en","11":"schnittstelle-seriell-en","12":"product_cat-net-serie","14":"first","15":"instock","16":"taxable","17":"shipping-taxable","18":"purchasable","19":"product-type-simple"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of NET-DEV-OPTO-IN16 with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Protocol transparency<\/strong><\/td>\n<td data-label=\"Market Comparison\">For many standard modules, the telegram structure or integration is manufacturer-specific.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Open CAN protocol for seamless integration into existing CAN architectures.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Facilitates integration into existing controllers, gateways, and CAN networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automatic telegram processing<\/strong><\/td>\n<td data-label=\"Market Comparison\">Recurring CAN telegrams often have to be processed using external control logic.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Auto TX\/RX mode for automatic processing of CAN packets.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Reduces the implementation effort in the controller and simplifies recurring communication tasks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>CAN standards and bit rates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Supported CAN parameters are often limited or less clearly specified.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Supports CAN 2.0A \/ 2.0B and bit rates from 10 kbit\/s to 1 Mbit\/s.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Offers greater flexibility when integrating into different CAN systems and existing installations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Interfaces<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only USB or PCI<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">USB, Ethernet and web interface<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables flexible connectivity options in various IT and industrial environments.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Industrial use<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often used for simple control tasks<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Designed for industrial automation and CAN networks<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Suitable for demanding applications with high requirements for stability and continuous operation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supported protocols<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only TCP<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">HTTP, UDP, TCP, DHCP, Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Expands application possibilities in modern network and IoT infrastructures.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Number of USB modules that can be used simultaneously<\/strong><\/td>\n<td data-label=\"Market Comparison\">1\u20134 modules, often without proper management<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Up to 16 modules per system<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables larger system configurations without additional distributors or expansion devices.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>FIFO functionality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not available in this price range<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Integrated FIFO buffer enables constant sampling rate and reduces network load<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Ensures a constant data rate and prevents loss of measured values under high system load or slow processing.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Ethernet Signal Isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not always galvanically isolated<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Galvanically isolated Ethernet interface for safe communication<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Protects connected systems from interference voltages and increases communication stability in industrial networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Digital inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Counter function per channel<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only simple status queries or a global counting function.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">16-bit counters per channel with up to 65,535 count cycles.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables direct capture of pulses and events without additional hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Wide voltage range<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only positive voltage levels are allowed.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Positive and negative voltages can be detected <\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Expands compatibility with various sensor signals and reduces the need for upstream signal conditioning.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Input filter<\/strong><\/td>\n<td data-label=\"Market Comparison\">Filter functions are often fixed or can only be configured to a limited extent.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Programmable filter for input state changes and counter functions.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Reduces bounce and improves the reliable detection of actual switching signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status display<\/strong><\/td>\n<td data-label=\"Market Comparison\">Channel statuses are often only visible to a limited extent or in aggregate.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">LED status indicator per input and output channel for quick visual inspection.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Speeds up diagnostics, commissioning, and troubleshooting directly at the module.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Detection of state changes<\/strong><\/td>\n<td data-label=\"Market Comparison\">Signal changes between two readout cycles are sometimes lost in standard modules.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Internal flip-flops detect transitions from low to high and high to low between two readout operations.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Improves event detection for short signal transitions and asynchronous state changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Signal isolation of the inputs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes without galvanic isolation or with reduced protection between the field and logic sides.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Electrically isolated optocoupler inputs for safe signal operation<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Increases operational reliability when detecting external switching and sensor signals.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Remote access<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely possible<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Direct access via web and Modbus\u2011TCP<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Allows for configuration and monitoring without physical presence, thereby supporting efficient maintenance processes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Add modules later<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually only a fixed number of I\/Os per module<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Additional I\/O modules can be added freely<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables step-by-step system expansion without replacing existing hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Form factor<\/strong><\/td>\n<td data-label=\"Market Comparison\">Larger modules, less space\u2011efficient<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Very compact with high channel count<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Reduces space requirements in the control cabinet and enables higher packing densities.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Combined I\/Os<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors separate I\/O types \u2192 more modules required<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Analog and digital I\/Os in one module<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Reduces the number of modules required and simplifies wiring and system architecture.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Inputs and outputs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only digital inputs or outputs<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Combination of digital inputs and relay outputs<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables compact control solutions without additional expansion modules.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Channels \/ modularity<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fixed number of outputs (e.g., 4\u201316)<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Flexible selection: 8, 16, 32 or 64 channels<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Allows for needs-based scaling and reduces oversizing.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Integration into IoT ecosystems<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low, only feasible via gateways<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Directly usable via Ethernet in IoT clouds \/ SCADA \/ edge systems<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables direct integration into modern cloud, SCADA, and edge systems without additional gateways.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support for many protocols<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only one or two protocols offered<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">HTTP, UDP, TCP, DHCP, Modbus-TCP<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Increases compatibility with existing network infrastructures and enables flexible communication concepts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>API concept<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers have different APIs per series<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Unified API for all series<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Simplifies maintenance and further development, as all series can be addressed via the same interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Modbus upgrade free of charge<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or not available at all<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Yes<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Expands communication capabilities without additional licensing costs or hardware changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC NET-DEV-OPTO-IN16<\/th >\n<th style=\"color: #555;\">Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"NET-DEV-OPTO-IN16\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the modules for distributed data acquisition for PLC systems with 24 V inputs\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Retrofit &#038; modernization of existing equipment:<br \/><\/strong>Thanks to DIN rail mounting and plug-and-play bus (DIN rail bus), existing systems can be quickly expanded or modernized\u2014without extensive rewiring.<\/li>\n<li><strong>Industrial automation:<br \/><\/strong>It monitors digital signals from machines and production systems for precise control and process management.<\/li>\n<li><strong>Laboratory automation:<br \/><\/strong>Digital signals from machines and production systems are reliably captured by the module for distributed data acquisition for PLC systems with 24 V inputs and provided for precise process control.<\/li>\n<li><strong>Test and inspection facilities:<br \/><\/strong>Even fast signal changes in harsh industrial environments are reliably processed by the module for distributed data acquisition for PLC systems with 24 V inputs.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p><\/p>\n<h3>Digital inputs:<\/h3>\n<ul>\n<li>Type: AC\/DC optocoupler<\/li>\n<li>Signal level: \u00b15 V to \u00b115 V or \u00b115 V to \u00b130 V<\/li>\n<li>16-bit counter per channel (up to 100 Hz)<\/li>\n<li>Detects a transition from low to high and from high to low (flip-flop)<\/li>\n<li>Status LED for each channel<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-NET-DEV-OPTO-IN16\">\n<h2>Product Description &#8211; module for distributed data acquisition for PLC systems with 24 V inputs<\/h2>\n<p>The NET-DEV-OPTO-IN16 is a versatile submodule of the NET series designed to extend industrial control systems with digital outputs. It provides a total of 16 digital output channels suitable for a wide range of switching and control tasks in automation applications. The outputs are implemented as galvanically isolated optocoupler outputs, enabling reliable switching of external loads within the typical industrial voltage range of +5 V to +50 V AC\/DC. Each channel is individually addressable, offering high flexibility for implementing complex control logic.<br \/>\nIntegrated galvanic isolation ensures safe decoupling between the control and load side, significantly increasing operational safety in industrial environments. The module for distributed data acquisition for PLC systems with 24 V inputs also supports per-channel status indication, allowing switching states to be visually monitored directly on the device. As a submodule, the NET-DEV-OPTO-IN16 is designed for integration into the NET system architecture and is easily expanded via the NET bus on the DIN rail. For operation, either a NET-CPU-BASE or a NET-CPU-PRO is required, which provides the central control and communication functionality.<br \/>\nOverall, the module for distributed data acquisition for PLC systems with 24 V inputs offers a robust, compact, and flexible solution for expanding digital output structures in demanding automation systems.<\/p>\n<h3>Galvanically isolated digital inputs with filtering functions for reliable signal acquisition<\/h3>\n<p>The digital inputs on the NET-DEV-OPTO-IN16 are implemented as opto-isolated switching inputs, ensuring reliable galvanic isolation between the field side and the internal electronics. They are designed for industrial 24 V AC\/DC signals and enable safe detection of switching states even in electrically noisy environments. The integrated filtering function suppresses short interference pulses, ensuring stable signal processing.<br \/>\nIn addition, the inputs feature event detection that reliably captures signal transitions and makes them available for further processing. In combination with counter and flip-flop functions, even fast pulses or state changes can be evaluated precisely. Each input of the NET-DEV-OPTO-IN16 is also equipped with an individual status LED that visually indicates the current switching state directly on the device, enabling fast on-site diagnostics.<br \/>\nAs a result, the digital inputs are ideally suited for industrial automation tasks where robust and reliable signal acquisition is required.<\/p>\n<h3>Event Control \u2013 event-based automation<\/h3>\n<p>The Event Control function enables direct, event-driven processing of both digital and analog signals in the module for distributed data acquisition for PLC systems with 24 V inputs, without requiring cyclic polling by higher-level software. Digital signal transitions can immediately trigger internal actions, while analog signals can generate events based on defined thresholds, measurement ranges, or significant value changes. This allows responses to be implemented much faster and more resource-efficiently compared to traditional polling-based processing.<br \/>\nThe event logic can be flexibly configured, enabling both simple switching conditions and more complex dependencies between digital and analog signals. In addition, functions such as filtering, hysteresis, and threshold monitoring are available to ensure stable and reliable trigger conditions.<br \/>\nAs a result, Event Control is particularly well suited for automation applications where signals must be evaluated intelligently and processed immediately.<\/p>\n<h3>Compact DIN-rail form factor for modular industrial integration<\/h3>\n<p>The NET-DEV-OPTO-IN16 is designed for industrial control cabinet installation in a compact DIN-rail form factor. Both interface modules and submodules feature a standardized, space-saving housing design that enables seamless system integration without additional adapters. Thanks to the modular design, components can easily be snapped onto the DIN rail and mechanically as well as electrically connected via the integrated T-bus.<br \/>\nThe submodules are equipped with WAGO plug-in connectors, enabling structured and reliable wiring of field signals and supporting a clear, service-friendly installation. This simplifies wiring while ensuring high connection and contact quality. The robust industrial design is intended for continuous operation under demanding environmental conditions. Overall, the unified form factor combined with modular wiring provides a scalable, well-organized, and maintenance-friendly system architecture within the control cabinet.<\/p>\n<h3>Application and Benefits<\/h3>\n<p>The NET-DEV-OPTO-IN16 offers a reliable and long-term solution for industrial automation tasks. With stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated and efficiently maintained. The robust electronics, developed in Germany and featuring galvanic isolation, ensure high operational reliability, while direct developer support and regular updates guarantee sustainable use in professional environments.<br \/>\n<br \/>\n<\/section>\n","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE ICT TOOL BE USED WITHOUT ANY CUSTOM PROGRAMMING?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, the ICT-Tool enables direct access to the modules without the need for custom software development. This allows functions, interfaces, and I\/O states to be quickly tested and verified.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">IS THERE A READY-MADE PROGRAMMING EXAMPLE FOR CONTROLLING THE MODULES USING MODBUS TCP?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, you will find a sample package containing a ready-made programming example for controlling our modules via Modbus TCP. In addition, the package includes examples for additional functions in all supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT THE AVAILABLE INTERFACES AND FUNCTIONS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete description of the supported interfaces, communication options, and device functions can be found in the module manual. It is available at any time via the \"Downloads and Manuals\" tab on the respective product page as well as in the download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND EXAMPLES FOR SOFTWARE-BASED CONTROL OF THE MODULE?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Examples for controlling the module, as well as information about supported programming languages and libraries, can be found in the module documentation and on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n","sge_text":"<p>The distributed data acquisition PLC 24V inputs enables flexible and scalable signal acquisition in industrial applications. The NET-DEV-OPTO-IN16 module provides 16 opto-isolated channels for reliable signal processing. The distributed data acquisition PLC 24V inputs is ideal for automation and retrofit projects. The product NET-DEV-OPTO-IN16 is widely used as an expansion module in industrial control systems.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":""},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25568580","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568580"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584632"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568580"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25568580"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25568580"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25568580"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}