{"id":25568493,"date":"2020-05-04T12:40:23","date_gmt":"2020-05-04T10:40:23","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/net-all-in-one\/"},"modified":"2026-09-14T10:15:22","modified_gmt":"2026-09-14T08:15:22","slug":"net-all-in-one","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/net-serie\/net-all-in-one\/","title":{"rendered":"NET-CPU-BASE\/PRO &#8211; Base module for modular measurement modules (Modbus TCP-compatible)"},"content":{"rendered":"<section class=\"ddt-product-description\">\n<h2>Product Description<\/h2>\n<p>The NET-CPU-BASE\/PRO is the central base module of the DEDITEC NET series for building modular measurement, control and automation systems. As an interface and communication unit, the module connects Ethernet\/TCP\/IP-based networks with modular I\/O submodules, forming the foundation of a modular Modbus TCP remote I\/O system. Digital and analog signals are acquired and output decentrally via suitable I\/O submodules and integrated into higher-level measurement, control or automation environments.<\/p>\n<h3>System Role in Modular Remote I\/O Architectures<\/h3>\n<p>Within the NET series, the NET-CPU-BASE\/PRO assumes the central communication and interface role. While the I\/O submodules represent the respective signal level, the base module provides the connection to the network and control level. This creates a scalable remote I\/O architecture in which inputs and outputs can be added as needed and placed close to machines, test benches, control cabinets or system areas.<\/p>\n<h3>Ethernet, TCP\/IP and Modbus TCP as Communication Basis<\/h3>\n<p>At the core of system integration is the Ethernet interface with 10\/100 Mbit\/s Ethernet, TCP\/IP and Modbus TCP. LAN configuration can be performed via the ICT tool; the IP address can be assigned via DHCP or configured statically. For industrial network environments, the Ethernet interface is galvanically isolated up to 1.5 kV AC for 1 minute. DIP switches support functions such as DHCP ON\/OFF, write protection, start with factory settings and bootloader start. The average access speed from the PC to the module is 1 ms, measured with 1000 accesses via the DELIB driver library.<\/p>\n<h3>Flexible Interfaces for Different Integration Tasks<\/h3>\n<p>In addition to Ethernet\/TCP\/IP and Modbus TCP, further interfaces are available depending on the variant for configuration, data communication and system integration. The USB interface is implemented as a Type-B connector and supports USB 2.0 \/ USB 1.1 with up to 480 Mbit\/s. The NET-CPU-PRO-CS additionally offers a CAN interface with CAN 2.0A or 2.0B, data rates from 10 kbit\/s to 1 Mbit\/s, galvanic isolation up to 500 V, open CAN protocol and automatic processing of CAN packets in Auto-TX\/RX mode. RS-232 and RS-485 are also available via a 9-pin D-sub connector. The RS-232 interface supports up to 115,200 baud and can be configured via the ICT tool or additionally via DIP switches. The RS-485 interface also supports up to 115,200 baud, is based on the TIA\/EIA-485-A standard and is galvanically isolated up to 500 V.<\/p>\n<h3>Modular Signal Level with I\/O Submodules<\/h3>\n<p>The NET-CPU-BASE\/PRO itself provides the central interface and communication level. The actual signal type is determined by the connected I\/O submodules of the NET series. This allows digital inputs, digital outputs, analog inputs, analog outputs or other I\/O functions to be combined as required. This separation between communication unit and signal level simplifies the step-by-step construction of modular I\/O stations and reduces effort when applications need to be expanded or adapted later.<\/p>\n<h3>Reliable Signal Processing, Diagnostics and Controlled Processes<\/h3>\n<p>For industrial applications, the NET-CPU-BASE\/PRO supports functions that simplify diagnostics, process monitoring and defined workflows. Event control enables linking events with actions according to an if-then logic. The FIFO function can buffer measurement data and supports smoother transmission of continuous measurement values. Timer functions allow automatic switching of outputs within defined time intervals. Status LEDs indicate communication, module status, interface state, error events, input state changes and timeout shutdowns. This makes the system suitable not only for pure data acquisition but also for decentralized monitoring, control and diagnostic tasks.<\/p>\n<h3>Typical Applications<\/h3>\n<ul>\n<li>Decentralized data acquisition in industrial systems and machines<\/li>\n<li>Modular remote I\/O stations with Ethernet, TCP\/IP and Modbus TCP<\/li>\n<li>Test bench setups with distributed digital and analog signals<\/li>\n<li>Control cabinet integration with modular I\/O expansion via DIN rail bus<\/li>\n<li>Measurement, control and automation tasks in mechanical engineering<\/li>\n<li>Ethernet-based process data acquisition in SCADA-related or edge-oriented environments<\/li>\n<li>Test, diagnostic and development environments with flexible I\/O structure<\/li>\n<\/ul>\n<h3>Integration, Configuration and Operation<\/h3>\n<p>Integration is primarily performed via Ethernet with TCP\/IP and Modbus TCP. The DEDITEC ICT tool is available for setup, LAN configuration, testing, diagnostics and firmware updates. Additionally, control can be performed via the DELIB driver library in various programming environments. This allows the NET-CPU-BASE\/PRO to be integrated into existing industrial networks, measurement systems, test bench architectures, SCADA-related environments and other higher-level automation structures. The combination of central base module, modular I\/O submodules and multiple communication interfaces supports a flexible remote I\/O architecture for industrial applications.<\/p>\n<h3>Made in Germany<\/h3>\n<p>DEDITEC develops and manufactures industrial I\/O, control and measurement modules in Germany. For the NET-CPU-BASE\/PRO, Made in Germany means product-focused development, transparent technical documentation and a design intended for use in industrial measurement, control and automation applications.<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<h2>Technical Data<\/h2>\n<p>The NET-CPU-BASE\/PRO is the central base module of the DEDITEC NET series for building a modular Modbus TCP remote I\/O system. Via Ethernet with TCP\/IP and Modbus TCP, the interface unit connects industrial networks with modular I\/O submodules. Depending on the submodules used, digital and analog signals can be acquired and output decentrally and integrated into measurement, control and automation environments.<\/p>\n<p>&nbsp;<\/p>\n<h3>At a Glance<\/h3>\n<ul>\n<li>Central base module for a modular Modbus TCP remote I\/O system of the DEDITEC NET series<\/li>\n<li>Interface and communication unit for modular I\/O submodules<\/li>\n<li>Ethernet interface with 10\/100 Mbit\/s Ethernet, TCP\/IP and Modbus TCP<\/li>\n<li>LAN configuration via ICT tool, IP address via DHCP or static<\/li>\n<li>DIN rail bus \/ NET bus for connecting additional NET modules<\/li>\n<li>Supply voltage: +7 V DC &#8230; +24 V DC<\/li>\n<li>Current consumption: max. 90 mA \/ 24 V<\/li>\n<li>Micro SD card slot and battery-buffered real-time clock<\/li>\n<li>USB Type-B interface with USB 2.0 \/ USB 1.1 up to 480 Mbit\/s<\/li>\n<li>CAN interface with CAN 2.0A \/ CAN 2.0B, open CAN protocol and Auto-TX\/RX mode<\/li>\n<li>Raw CAN<\/li>\n<li>RS-232 and RS-485 interfaces with up to 115,200 baud<\/li>\n<li>Event control, FIFO function, A\/D software filter, timer function and fail-safe function<\/li>\n<li>DIN rail mounting 35 x 7.5 mm<\/li>\n<li>Operating temperature: +10 \u00b0C &#8230; +50 \u00b0C<\/li>\n<li>Dimensions: 117 mm x 22.5 mm x 111 mm (H x W x D)<\/li>\n<\/ul>\n<h3>Interfaces and Integration<\/h3>\n<ul>\n<li>Ethernet interface with 10\/100 Mbit\/s Ethernet<\/li>\n<li>Galvanic isolation of the Ethernet interface up to 1.5 kV \/ AC 1 min<\/li>\n<li>Modbus TCP for integration into Ethernet\/TCP\/IP-based automation environments<\/li>\n<li>LAN configuration via the ICT tool, e.g. IP address and subnet mask<\/li>\n<li>IP address via DHCP or static configuration<\/li>\n<li>DIP switches for DHCP ON\/OFF, write protection ON\/OFF, start with factory settings and bootloader start<\/li>\n<li>Average access speed from PC to module: 1 ms, calculated with 1000 accesses via the DELIB driver library using the command DapiDoSet32<\/li>\n<li>USB Type-B interface with USB 2.0 \/ USB 1.1 up to 480 Mbit\/s<\/li>\n<li>CAN interface via 9-pin D-sub connector<\/li>\n<li>CAN 2.0A or CAN 2.0B with 1 Mbit\/s, 500 kbit\/s, 250 kbit\/s, 125 kbit\/s, 100 kbit\/s, 50 kbit\/s, 20 kbit\/s or 10 kbit\/s<\/li>\n<li>Galvanically isolated CAN interface up to 500 V<\/li>\n<li>Open CAN protocol (Raw CAN) and automatic processing of CAN packets in Auto-TX\/RX mode<\/li>\n<li>RS-232 interface via 9-pin D-sub connector, up to 115,200 baud, galvanically isolated up to 500 V<\/li>\n<li>RS-485 interface via 9-pin D-sub connector, up to 115,200 baud, TIA\/EIA-485-A standard, galvanically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Modular I\/O Expansion and Signal Processing<\/h3>\n<ul>\n<li>NET bus connector for connecting additional NET modules<\/li>\n<li>DIN rail bus for modular expansion within the NET series<\/li>\n<li>The power supply also powers the DIN rail bus<\/li>\n<li>Digital and analog signal processing via suitable I\/O submodules<\/li>\n<li>Suitable for building modular remote I\/O stations in control cabinet, machine and test bench environments<\/li>\n<li>A\/D software filter for smoothing and optimizing electrical interference in analog measurement signals<\/li>\n<li>FIFO function for buffering continuous measurement data and smoother transmission over Ethernet<\/li>\n<li>Timer function for automatic switching of outputs within a freely definable time period<\/li>\n<\/ul>\n<h3>Fail-Safe, Diagnostics and Operational Safety<\/h3>\n<ul>\n<li>Fail-safe function with software-configurable timeout protection<\/li>\n<li>Timeout activation time adjustable between 0.1 seconds and 6553 seconds<\/li>\n<li>Digital outputs can be activated, deactivated or left unchanged in a timeout event<\/li>\n<li>Timeout mode \u201cNormal\u201d for one-time valid timeout protection with manual reactivation<\/li>\n<li>Timeout mode \u201cAuto reactivate\u201d for automatic reactivation after communication with the control PC is restored<\/li>\n<li>Timeout mode \u201cSecure Outputs\u201d for locking output access after a timeout event<\/li>\n<li>Status LEDs for DIN rail bus communication, module status, Ethernet activity, USB activity, interface status, error, input state change and timeout shutdown<\/li>\n<li>CAN activity and SER activity as LED indicators on the NET-CPU-PRO-CS variant<\/li>\n<\/ul>\n<h3>Mechanics and Environmental Conditions<\/h3>\n<ul>\n<li>Supply voltage: +7 V DC &#8230; +24 V DC<\/li>\n<li>Current consumption: max. 90 mA \/ 24 V<\/li>\n<li>External memory: Micro SD card slot<\/li>\n<li>Real-time clock: battery-buffered, CR2032<\/li>\n<li>Phoenix Contact 1893313 terminal block for power supply connection<\/li>\n<li>For conductor types from 0.2 mm\u00b2 &#8230; 2.5 mm\u00b2<\/li>\n<li>Pluggable terminal block<\/li>\n<li>DIN rail mounting: 35 x 7.5 mm<\/li>\n<li>Operating temperature: +10 \u00b0C &#8230; +50 \u00b0C<\/li>\n<li>Dimensions: 117 mm x 22.5 mm x 111 mm (H x W x D)<\/li>\n<\/ul>\n","protected":false},"featured_media":25584369,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[201],"product_tag":[],"class_list":{"0":"post-25568493","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-pwm","7":"einausgang-temperatur-eingaenge","8":"schnittstelle-seriell-en","9":"schnittstelle-can-en","10":"schnittstelle-usb-en","11":"schnittstelle-ethernet-en","12":"product_cat-net-serie","13":"product_shipping_class-ups-standard-en","14":"pa_net-interface-version-net-cpu-pro-modul-mit-den-schnittstellen-eth-usb-can-ser_en","15":"pa_net-interface-version-net-cpu-base-modul-mit-den-schnittstellen-eth-usb_en","17":"first","18":"instock","19":"taxable","20":"shipping-taxable","21":"purchasable","22":"product-type-variable"},"acf":{"produktvergleich_rest_api":"","zusatztext_rest_api":"","technische_daten_rest_api":"","produktvergleich":"<h2>Comparison: Modular Modbus TCP Remote I\/O System \u2013 NET-CPU-BASE\/PRO<\/h2>\n<p>The following comparison classifies the NET-CPU-BASE\/PRO technically: as the central base module of the DEDITEC NET series for building modular remote I\/O stations with Ethernet, TCP\/IP and Modbus TCP. The focus is on the system architecture with I\/O submodules, industrial network integration, modular expandability, diagnostic and safety functions, and integration into measurement, control and automation environments.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Product Type, System Architecture and Remote I\/O Usage<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>NET-CPU-BASE\/PRO<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td>Product Type<\/td>\n<td>Many I\/O solutions are designed as fixed single modules with predefined input and output channels.<\/td>\n<td>Central base module for a modular Modbus TCP remote I\/O system of the DEDITEC NET series.<\/td>\n<td>Suitable when a scalable remote I\/O architecture with expandable I\/O submodules is required instead of a rigid single-module solution.<\/td>\n<\/tr>\n<tr>\n<td>System Role<\/td>\n<td>In classic I\/O modules, communication and signal levels are often combined in one device.<\/td>\n<td>Interface and communication unit between Ethernet\/TCP\/IP networks and modular I\/O submodules.<\/td>\n<td>Communication and signal levels can be planned separately; the I\/O structure can be built using suitable submodules depending on the application.<\/td>\n<\/tr>\n<tr>\n<td>Modular Expandability<\/td>\n<td>In many compact I\/O modules, the channel count is fixed by the device variant.<\/td>\n<td>Expansion via NET bus \/ DIN rail bus for connecting additional NET modules.<\/td>\n<td>Supports step-by-step construction of modular I\/O stations in control cabinet, machine and test bench environments.<\/td>\n<\/tr>\n<tr>\n<td>Signal Level<\/td>\n<td>Single modules are often limited to specific signal types or channel types.<\/td>\n<td>Digital and analog signals are implemented via suitable I\/O submodules of the NET series.<\/td>\n<td>A system can be assembled with suitable submodules for different measurement, control and automation tasks.<\/td>\n<\/tr>\n<tr>\n<td>Typical Application Environment<\/td>\n<td>Many I\/O modules are described generally for automation tasks without clearly defining the system architecture.<\/td>\n<td>Modular remote I\/O stations for industrial automation, decentralized data acquisition, test benches, mechanical engineering and control cabinet integration.<\/td>\n<td>The product role is clearly defined: central communication unit for distributed I\/O structures instead of a single fixed I\/O end device.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Ethernet, Modbus TCP and Interface Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>NET-CPU-BASE\/PRO<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td>Ethernet Communication<\/td>\n<td>Industrial I\/O systems differ significantly in interface type, protocol support and network capability.<\/td>\n<td>10\/100 Mbit\/s Ethernet with TCP\/IP and Modbus TCP.<\/td>\n<td>Enables integration into Ethernet\/TCP\/IP-based automation, measurement and data acquisition environments.<\/td>\n<\/tr>\n<tr>\n<td>Modbus TCP<\/td>\n<td>Not every Ethernet I\/O solution supports an open, widely used industrial communication protocol.<\/td>\n<td>Modbus TCP for data exchange over Ethernet.<\/td>\n<td>Simplifies integration into existing Modbus TCP environments and higher-level measurement, control or visualization systems.<\/td>\n<\/tr>\n<tr>\n<td>Network Configuration<\/td>\n<td>Configuration of industrial Ethernet modules varies by manufacturer (tools, web interfaces, direct commands).<\/td>\n<td>LAN configuration via ICT tool; IP address via DHCP or static.<\/td>\n<td>Supports traceable commissioning and simplifies adaptation to existing network structures.<\/td>\n<\/tr>\n<tr>\n<td>DIP Switches<\/td>\n<td>Basic functions are often only accessible via software or require separate configuration paths.<\/td>\n<td>DIP switches for DHCP ON\/OFF, write protection ON\/OFF, start with factory settings and bootloader start.<\/td>\n<td>Simplifies service, commissioning and restoring defined device states directly on the module.<\/td>\n<\/tr>\n<tr>\n<td>Access Speed<\/td>\n<td>Practical access speed depends on protocol, driver, network and application.<\/td>\n<td>Average access time from PC to module: 1 ms, measured with 1000 accesses via DELIB using DapiDoSet32.<\/td>\n<td>Helps evaluate PC-based measurement, control and test applications with frequent I\/O access.<\/td>\n<\/tr>\n<tr>\n<td>USB Interface<\/td>\n<td>Not every Ethernet or remote I\/O system offers an additional local interface for setup and service.<\/td>\n<td>USB Type B with USB 2.0 \/ USB 1.1 up to 480 Mbit\/s.<\/td>\n<td>Supports local commissioning, parameterization and testing without relying solely on network communication.<\/td>\n<\/tr>\n<tr>\n<td>CAN Interface<\/td>\n<td>Additional CAN functions are not always integrated or require separate components.<\/td>\n<td>CAN 2.0A or CAN 2.0B via 9-pin D-sub, bit rates from 10 kbit\/s to 1 Mbit\/s, open CAN protocol and Auto-TX\/RX mode.<\/td>\n<td>Expands integration options for CAN-based machine, test bench or automation environments.<\/td>\n<\/tr>\n<tr>\n<td>Serial Interfaces<\/td>\n<td>RS-232 and RS-485 are not always provided in modern Ethernet I\/O systems.<\/td>\n<td>RS-232 and RS-485 via 9-pin D-sub connectors up to 115,200 baud; RS-485 according to TIA\/EIA-485-A.<\/td>\n<td>Simplifies integration of serial devices, existing system components or project-specific interface environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Signal Processing, Diagnostics and Operational Safety<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>NET-CPU-BASE\/PRO<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td>Event Control<\/td>\n<td>In simple remote I\/O modules, event logic often must be implemented entirely in an external application.<\/td>\n<td>Event control for linking events with actions using if-then logic directly in module memory.<\/td>\n<td>Supports simple decentralized control and monitoring tasks without fully external programming.<\/td>\n<\/tr>\n<tr>\n<td>FIFO Function<\/td>\n<td>Continuous measurement data transmission can fluctuate due to network traffic or polling cycles.<\/td>\n<td>FIFO function for buffering continuous measurement data on the module and transmitting it over Ethernet.<\/td>\n<td>Supports smoother data transmission and improves usability in continuous measurement and test workflows.<\/td>\n<\/tr>\n<tr>\n<td>A\/D Software Filter<\/td>\n<td>Interference on analog measurement signals must often be handled externally.<\/td>\n<td>A\/D software filter for smoothing and optimizing electrical interference in analog measurement signals.<\/td>\n<td>Helps stabilize analog values in electrically demanding measurement and automation environments.<\/td>\n<\/tr>\n<tr>\n<td>Timer Function<\/td>\n<td>Time-controlled switching often must be implemented entirely in control software.<\/td>\n<td>Automatic switching of outputs within freely definable time intervals.<\/td>\n<td>Simplifies recurring switching tasks and supports defined workflows in test, inspection and automation applications.<\/td>\n<\/tr>\n<tr>\n<td>Fail-Safe Function<\/td>\n<td>Output behavior during communication failure varies widely and must be checked per system.<\/td>\n<td>Software-configurable timeout protection; outputs can be activated, deactivated or left unchanged.<\/td>\n<td>Supports defined output states during communication issues and increases predictability in fault scenarios.<\/td>\n<\/tr>\n<tr>\n<td>Timeout Modes<\/td>\n<td>Timeout behavior differs by system regarding reactivation and output locking.<\/td>\n<td>Timeout modes \u201cNormal\u201d, \u201cAuto reactivate\u201d and \u201cSecure Outputs\u201d.<\/td>\n<td>Allows adapting timeout behavior to different safety, service and automation requirements.<\/td>\n<\/tr>\n<tr>\n<td>Status Indicators<\/td>\n<td>Diagnostic information is often limited or only available via software.<\/td>\n<td>LEDs for DIN rail bus communication, module status, Ethernet activity, USB activity, interface status, error, input state change and timeout shutdown; CAN and SER activity on NET-CPU-PRO-CS.<\/td>\n<td>Simplifies commissioning, service and troubleshooting directly on the module.<\/td>\n<\/tr>\n<tr>\n<td>Galvanic Isolation<\/td>\n<td>Electrical isolation varies widely across industrial I\/O systems.<\/td>\n<td>Ethernet isolated up to 1.5 kV AC; CAN, RS-232 and RS-485 isolated up to 500 V.<\/td>\n<td>Reduces risks from potential differences and supports use in industrial control cabinet, machine and test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Mechanics, Mounting and Control Cabinet Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>NET-CPU-BASE\/PRO<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td>Power Supply<\/td>\n<td>Industrial I\/O modules are typically designed for DC supply ranges that must be checked per system.<\/td>\n<td>+7 V DC &#8230; +24 V DC; also powers the DIN rail bus.<\/td>\n<td>Supports operation in industrial DC environments and powers the modular DIN rail bus.<\/td>\n<\/tr>\n<tr>\n<td>Current Consumption<\/td>\n<td>Power consumption affects cabinet planning, supply design and thermal evaluation.<\/td>\n<td>Max. 90 mA \/ 24 V.<\/td>\n<td>Simplifies electrical design of modular I\/O stations in control cabinets or test benches.<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>Depending on the I\/O system, additional adapters or special housings may be required.<\/td>\n<td>DIN rail mounting 35 \u00d7 7.5 mm and DIN rail bus for modular expansion.<\/td>\n<td>Simplifies building compact remote I\/O stations in control cabinets, machines and test benches.<\/td>\n<\/tr>\n<tr>\n<td>Terminal Block<\/td>\n<td>Wiring and service depend heavily on terminal type, conductor size and plug-in capability.<\/td>\n<td>Phoenix Contact 1893313 for power supply; supports 0.2 mm\u00b2 &#8230; 2.5 mm\u00b2; pluggable.<\/td>\n<td>Supports service-friendly wiring and simplifies installation, replacement and commissioning.<\/td>\n<\/tr>\n<tr>\n<td>Memory and RTC<\/td>\n<td>Additional memory or time functions are not always available in simple I\/O modules.<\/td>\n<td>Micro SD card slot and battery-buffered real-time clock (CR2032).<\/td>\n<td>Useful for applications requiring local storage or time functions for configuration, sequencing or diagnostics.<\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td>Temperature ranges must be evaluated for cabinet, test field or lab environments.<\/td>\n<td>+10 \u00b0C &#8230; +50 \u00b0C.<\/td>\n<td>Suitable for typical industrial indoor, cabinet, test bench and laboratory environments.<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Available space is a key planning factor in modular I\/O stations and cabinet layouts.<\/td>\n<td>117 mm \u00d7 22.5 mm \u00d7 111 mm (H \u00d7 W \u00d7 D).<\/td>\n<td>Compact module width supports space-saving DIN rail installations with modular expansion.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Software, Commissioning and Service<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>NET-CPU-BASE\/PRO<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td>ICT Tool<\/td>\n<td>Many I\/O systems require multiple tools for setup, diagnostics, testing or firmware maintenance.<\/td>\n<td>ICT tool for integration, configuration, testing, diagnostics and firmware updates.<\/td>\n<td>Simplifies commissioning, testing and maintenance through a unified software environment.<\/td>\n<\/tr>\n<tr>\n<td>DELIB Driver Library<\/td>\n<td>Software integration varies by manufacturer and may be limited to specific platforms or libraries.<\/td>\n<td>Access via DELIB driver library and API for various programming environments.<\/td>\n<td>Simplifies integration into custom measurement, test bench, control and automation software.<\/td>\n<\/tr>\n<tr>\n<td>Command-Line Interface<\/td>\n<td>Automated tests and service processes may require additional software or custom scripts.<\/td>\n<td>CLI for products with Ethernet or USB interface; supports digital and analog I\/O.<\/td>\n<td>Enables script-based tests, commissioning workflows and service processes under Windows and Linux.<\/td>\n<\/tr>\n<tr>\n<td>Software Maintenance<\/td>\n<td>Updates for tools, drivers or libraries may be limited or product-dependent.<\/td>\n<td>Free updates and software maintenance according to existing comparison content.<\/td>\n<td>Supports long-term maintenance of measurement, control and automation software across the product lifecycle.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Manufacturer, Availability and Support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th>Feature<\/th>\n<th>Market Comparison<\/th>\n<th>NET-CPU-BASE\/PRO<\/th>\n<th>Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td>Production Location<\/td>\n<td>In industrial electronics, origin, manufacturing depth and supply chains vary widely.<\/td>\n<td>Made in Germany.<\/td>\n<td>Relevant for B2B applications requiring traceable manufacturing, technical coordination and long-term project planning.<\/td>\n<\/tr>\n<tr>\n<td>Long-Term Availability<\/td>\n<td>Product lifecycles and availability vary significantly across automation components.<\/td>\n<td>10 years guaranteed.<\/td>\n<td>Supports plant engineering, series machinery, retrofit projects and test bench systems requiring predictable spare parts availability.<\/td>\n<\/tr>\n<tr>\n<td>Support Quality<\/td>\n<td>Support may be provided via sales, standard documentation, external service providers or general channels.<\/td>\n<td>Direct developer support.<\/td>\n<td>Helpful for interface questions, commissioning, special applications and technical coordination.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext":"<h2>Typical Application Areas of the NET-CPU-BASE\/PRO<\/h2>\n<p>The NET-CPU-BASE\/PRO is suitable for industrial applications where digital and analog signals need to be acquired, output or integrated decentrally into higher-level measurement, control and automation environments. As the central base module of the DEDITEC NET series, the interface unit connects Ethernet with TCP\/IP and Modbus TCP to modular I\/O submodules. This makes the system particularly suitable for scalable remote I\/O architectures in machines, plants, test benches and control cabinets.<\/p>\n<p>&nbsp;<\/p>\n<h3>Suitable for<\/h3>\n<ul>\n<li>Machine and plant engineering<\/li>\n<li>Industrial automation and decentralized automation<\/li>\n<li>Control cabinet construction and DIN-rail I\/O systems<\/li>\n<li>Test benches, test systems and quality assurance<\/li>\n<li>Industrial data acquisition and process monitoring<\/li>\n<li>Measurement, control and automation tasks<\/li>\n<li>Modular remote I\/O stations with Ethernet and Modbus TCP<\/li>\n<li>Edge-oriented data acquisition in distributed I\/O systems<\/li>\n<li>Special-purpose machinery, development and technical integration<\/li>\n<li>Modernization of existing automation and measurement systems<\/li>\n<\/ul>\n<h3>Typical Applications<\/h3>\n<ul>\n<li>Decentralized acquisition of digital and analog signals via modular I\/O submodules<\/li>\n<li>Building modular Modbus TCP remote I\/O stations for machines, plants and test benches<\/li>\n<li>Ethernet-based process data acquisition in industrial network environments<\/li>\n<li>Expanding existing measurement, control and automation systems with flexible I\/O structures<\/li>\n<li>Control cabinet integration via DIN rail bus \/ NET bus with modular expandability<\/li>\n<li>Connecting I\/O signals to higher-level automation, measurement or visualization systems<\/li>\n<li>Test bench setups with distributed inputs and outputs<\/li>\n<li>Diagnostic, test and development environments with configurable interfaces<\/li>\n<li>Decentralized monitoring of signal states, communication, error events and timeout conditions<\/li>\n<li>Automation tasks with event control, timer functions, FIFO buffering and fail-safe behavior<\/li>\n<\/ul>\n<h3>Typical Signal and Switching Tasks<\/h3>\n<ul>\n<li>Acquiring digital input states via suitable I\/O submodules<\/li>\n<li>Outputting digital switching signals via modular output modules<\/li>\n<li>Acquiring analog measurement values via suitable A\/D submodules<\/li>\n<li>Outputting analog setpoints via suitable D\/A submodules<\/li>\n<li>Transmitting process, status and measurement data via Ethernet, TCP\/IP and Modbus TCP<\/li>\n<li>Buffering continuous measurement data using FIFO functionality<\/li>\n<li>Time-controlled switching of outputs via timer functions<\/li>\n<li>Executing simple if-then sequences via event control<\/li>\n<li>Defining safe output states in timeout or communication failure scenarios<\/li>\n<li>Expanding distributed I\/O systems via NET bus and DIN rail bus<\/li>\n<\/ul>\n","produktbeschreibung_rest_api":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">THROUGH WHICH SOFTWARE INTERFACES IS THE NET-CPU-BASE\/PRO CONTROLLED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>USB models are integrated into software via the DEDITEC DELIB driver library. Ethernet models can, in addition to the DELIB library, also be accessed directly via TCP\/IP, Modbus TCP, or the web interface.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW CAN THE MODULES BE CONFIGURED, TESTED, AND UPDATED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Configuration, diagnostics, and commissioning are conveniently performed using the DEDITEC ICT-Tool. It also allows functions to be tested and firmware updates to be carried out.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND CURRENT DOCUMENTATION AND TECHNICAL RESOURCES?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Current manuals, technical documentation, and other product-specific materials can be found directly on the product page under \"Downloads and Manuals\". In addition, these documents are also available for download in the central download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND EXAMPLES FOR SOFTWARE-BASED CONTROL OF THE MODULE?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Examples for controlling the module, as well as information about supported programming languages and libraries, can be found in the module documentation and on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n","sge_text":"<p>The NET-CPU-BASE\/PRO is the central base module for a modular Modbus TCP remote I\/O system in the DEDITEC NET series. Via Ethernet with TCP\/IP and Modbus TCP, the interface unit connects modular I\/O submodules for the decentralized acquisition and output of digital and analog signals. Typical applications include industrial automation, decentralized data acquisition, mechanical engineering, test benches, and control cabinet integration.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":""},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25568493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568493"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584369"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568493"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25568493"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25568493"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25568493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}