{"id":25568053,"date":"2023-08-15T11:17:40","date_gmt":"2023-08-15T09:17:40","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/uc-usb-16-bit-d-a-wandler-mit-galvanischer-trennung-2-kanaele\/"},"modified":"2026-08-14T16:08:11","modified_gmt":"2026-08-14T14:08:11","slug":"usb-20ma-analog-industrial-io-box-da-16-bit-converter","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/usb\/usb-20ma-analog-industrial-io-box-da-16-bit-converter\/","title":{"rendered":"USB 20mA analog industrial I\/O box * 16-bit D\/A converter with galvanic isolation &#8211; 2 channels"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25584048,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[245,1582],"product_tag":[],"class_list":{"0":"post-25568053","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ao2","7":"einausgang-analoge-ausgaenge","8":"schnittstelle-usb-en","9":"product_cat-uc","10":"product_cat-usb","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"purchasable","17":"product-type-simple"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-USB-DA2-16ISO with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>USB Standard<\/strong><\/td>\n<td data-label=\"Market Comparison\">usually only USB-A \/ B<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Thanks to USB-C, it is significantly more modern and faster than typical USB I\/O boards<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Improves compatibility with current devices and simplifies integration.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Number of USB modules that can be used simultaneously<\/strong><\/td>\n<td data-label=\"Market Comparison\">1\u20134 modules, often without proper management<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Up to 16 modules per system<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Enables larger system configurations without additional distributors or expansion devices.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog outputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Analog voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Basic analog outputs, often only 0\u20135 V or 0\u201310 V<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Precise voltage output over 0\u20135 V, 0\u201310 V or \u00b110 V<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Enables precise control of various actuators and reduces the need for external signal converters.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Current and voltage output<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some providers offer only voltage or only current<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Both signal types supported<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Increases compatibility with various industrial and process signals and simplifies integration into existing systems.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Low output ripple<\/strong><\/td>\n<td data-label=\"Market Comparison\">Stronger ripple in OEM modules<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Low ripple and stable output signals<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Improves signal quality and ensures stable output values in sensitive control and regulation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Protects connected devices from interference voltages and prevents feedback between the output stage and the power supply.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation between all channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often a common reference potential for all channels<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Galvanic isolation up to 500 V between all channels<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Enables operation in systems with different reference potentials and prevents compensation currents between channels.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-USB-DA2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-USB-DA2-16ISO\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the USB I\/O boxes, industrial modules with 20 mA analog outputs\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Decentralized I\/O expansion of existing systems:<br \/><\/strong>Scalable extension of control architectures through modular USB I\/O components directly at the machine environment.<\/li>\n<li><strong>Condition monitoring and predictive maintenance:<br \/><\/strong>Continuous condition monitoring for early fault detection.<\/li>\n<li><strong>Labor and testing technology:<br \/><\/strong>The USB I\/O boxes, industrial modules with 20 mA analog outputs is ideally suited for experimental setups, data acquisition, and calibrations where high precision and reliability are essential.<\/li>\n<li><strong>Test systems:<br \/><\/strong>Flexible control of individual channels supports simulations and repeatable test procedures.<\/li>\n<li><strong>Automated test benches:<br \/><\/strong>Precise D\/A signal control for test and validation environments.<\/li>\n<li><strong>Laboratory and measurement systems:<br \/><\/strong>For measurement and control tasks, the UC-USB-DA2-16ISO provides high-resolution analog outputs.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The UC-USB-DA2-16_ISO Industrial IO Box is a high-precision USB analog-to-digital converter with two galvanically isolated 16-bit outputs. The module can output voltage and current and supports ranges such as 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V, and 0\u201320 mA. Sense lines compensate for line losses and ensure stable signals. Via USB-C, the IO-Box integrates reliably into industrial control and automation environments.<br \/>\n<\/p>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>Analog outputs:<\/h3>\n<ul>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V<\/li>\n<li>Current ranges: 0\u201320 mA, 4\u201320 mA, 0\u201324 mA<\/li>\n<li>Channel-to-channel isolation: max. 1 kV AC<\/li>\n<li>Isolation from power supply: max. 500 V AC<\/li>\n<li>Load resistance: \u2265 1 k\u03a9<\/li>\n<li>All D\/A channels are galvanically isolated from one another<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-USB-DA2-16ISO\">\n<h2>Product Description \u2013 USB I\/O box, industrial module with 20 mA analog outputs<\/h2>\n<p>The USB 20mA Analog Industrial I\/O Box UC-USB-DA2-16ISO is a high-performance, industrial-grade D\/A converter with two galvanically isolated 16-bit outputs. The module generates precise analog voltage and current signals and supports typical industrial ranges such as 0\u20135 V, 0\u201310 V, \u00b15 V, \u00b110 V, and 0\u201320 mA via external converters. Electrical isolation up to 500 V reliably protects connected systems from interference, ground loops, and potential differences.<br \/>\nThe I\/O Box is ideal for applications requiring precise analog signals\u2014such as for controlling actuators, valves, or control elements, or for simulating process signals in laboratory and test environments. The integrated sense line enables automatic compensation for line losses, ensuring stable output values even with longer cable runs.<br \/>\nThanks to USB-C Plug &#038; Play, the module is ready for immediate use and is recognized without additional drivers. The screwless WAGO connectors ensure secure, fast, and mis-insertion-protected wiring. The system can be flexibly expanded via the DIN-rail bus without additional cabling effort.<br \/>\nThe DELIB API is available for software integration and is compatible with C, C++, C#, Java, Python, and other languages. This allows the USB 20 mA Analog Industrial I\/O Box to be seamlessly integrated into automation, testing, and control environments.<\/p>\n<h3>Reliable USB communication interface for precise system integration<\/h3>\n<p>The USB interface of the UC-USB-DA2-16ISO is based on a modern USB-C connection and enables reliable and fast communication with the host system. It supports USB 2.0 as well as USB 1.1 and achieves a data transfer rate of up to 480 Mbit\/s. Thanks to plug-and-play functionality, the USB I\/O box, industrial module with 20 mA analog outputs is automatically recognized by the operating system and is immediately ready for use without additional basic configuration. Communication is handled via an optimized connection to the DELIB driver library, ensuring efficient and low-latency control. Typical access times in the millisecond range enable precise and stable data transmission even in time-critical applications. The USB-C interface also provides a robust and future-proof physical connection.<\/p>\n<h3>USB control via API commands and integrated driver interface<\/h3>\n<p>The USB connection of the module enables direct and straightforward control via an integrated driver and API structure (DELIB API). Following the plug-and-play principle, the USB I\/O box, industrial module with 20 mA analog outputs is automatically detected by the system and can then be addressed in software through standardized function calls. For all digital inputs and outputs as well as counter and status functions, defined API commands are available to read and control states.<br \/>\nCommunication with the UC-USB-DA2-16ISO is typically handled via a DLL-based library that can be integrated into common programming languages such as Python, C, C++, C#, Java, VB, and LabVIEW. This allows the development of custom applications, control programs, or test environments without the need to handle low-level USB communication.<br \/>\nIn addition, the module provides a command-line interface (CLI), enabling simple control and query commands to be executed directly from scripts or terminal applications.<br \/>\nIn practical use, this means that switching states of individual outputs or reading input signals can be controlled in real time using just a few API function calls. As a result, USB control is particularly well suited for automation tasks, test benches, and PC-based control applications with direct hardware integration.<\/p>\n<h3>Precise analog outputs for demanding control and regulation applications<\/h3>\n<p>The USB I\/O box, industrial module with 20 mA analog outputs features analog outputs with 16-bit resolution, enabling very fine and highly reproducible signal generation. Supported voltage ranges include 0\u20135 V, 0\u201310 V, as well as \u00b15 V and \u00b110 V, allowing flexible adaptation to different industrial actuators. The outputs offer high accuracy, low drift, and stable long-term performance, even during continuous operation.<br \/>\nWith short response times, the system is also well suited for dynamic control processes and rapid setpoint changes. Overall, the UC-USB-DA2-16ISO is ideal for precise control and regulation tasks in demanding industrial environments.<\/p>\n<h3>Robust industrial design with a well-engineered connection and mounting architecture<\/h3>\n<p>The USB I\/O box, industrial module with 20 mA analog outputs is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-USB-DA2-16ISO, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm\u00b2. In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.<\/p>\n<h3>Application and Benefits<\/h3>\n<p>The UC-USB-DA2-16ISO offers a reliable and long-term solution for industrial automation tasks. With stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated and efficiently maintained. The robust electronics, developed in Germany and featuring galvanic isolation, ensure high operational reliability, while direct developer support and regular updates guarantee sustainable use in professional environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"<p>The USB 20mA Analog Industrial I\/O Box UC-USB-DA2-16ISO offers two galvanically isolated 16-bit D\/A outputs for precise voltage and current signals up to 24 mA. Ideal for industrial control and regulation tasks. Typical applications: Control of valves or actuators, as well as simulation of analog process signals in laboratory and test bench environments. Plug-and-play via USB-C simplifies integration.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE UC-USB-DA2-16ISO BE TESTED VIA USB WITHOUT CUSTOM SOFTWARE?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, all inputs can be tested and visualized using the ICT-Tool. The tool displays the status of the optocoupler inputs as well as counter and event information in real time, without requiring any custom programming.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE MODULE BE USED WITHOUT AN ADDITIONAL PLC?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, thanks to the integrated event control, control tasks can be executed directly on the module. Using the ICT-Tool, \u201cif-then\u201d actions can be configured, enabling many applications to be implemented without an additional control PC or PLC.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN PYTHON?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, we provide a comprehensive example package. It contains ready-made Python programming examples that allow you to quickly integrate our modules into your application.\nIn addition, you will also find examples for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT THE AVAILABLE INTERFACES AND FUNCTIONS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete description of the supported interfaces, communication options, and device functions can be found in the module manual. It is available at any time via the \"Downloads and Manuals\" tab on the respective product page as well as in the download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE ARE THE COMMANDS FOR CONTROLLING THE MODULE DOCUMENTED?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The available commands for controlling and querying the module are described in detail in the module manual. Alternatively, the corresponding information can also be found on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25568053","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568053"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584048"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568053"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25568053"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25568053"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25568053"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}