{"id":25568026,"date":"2023-08-15T11:22:27","date_gmt":"2023-08-15T09:22:27","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/uc-can-16-18-bit-a-d-wandler-mit-galvanischer-trennung-2-kanaele\/"},"modified":"2026-08-14T16:06:38","modified_gmt":"2026-08-14T14:06:38","slug":"can-industrial-measurement-test-benches-galvanically-isolated","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/can\/can-industrial-measurement-test-benches-galvanically-isolated\/","title":{"rendered":"Can industry test benches with galvanic isolation * 16\/18-bit A\/D converter with galvanic isolation &#8211; 2 channels"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25584305,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[244,1577],"product_tag":[],"class_list":{"0":"post-25568026","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-ai2","7":"einausgang-analoge-eingaenge","8":"einausgang-_analog","9":"konfigurations_interface-usb","10":"schnittstelle-can","11":"product_cat-uc","12":"product_cat-can","13":"pa_interface_uc-uc_can_eth","14":"pa_interface_uc-uc_can_usb","16":"first","17":"instock","18":"taxable","19":"shipping-taxable","20":"purchasable","21":"product-type-variable"},"acf":{"produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-CAN-AD2-16ISO with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Protocol transparency<\/strong><\/td>\n<td data-label=\"Market Comparison\">For many standard modules, the telegram structure or integration is manufacturer-specific.<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Open CAN protocol for seamless integration into existing CAN architectures.<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Facilitates integration into existing controllers, gateways, and CAN networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automatic telegram processing<\/strong><\/td>\n<td data-label=\"Market Comparison\">Recurring CAN telegrams often have to be processed using external control logic.<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Auto TX\/RX mode for automatic processing of CAN packets.<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Reduces the implementation effort in the controller and simplifies recurring communication tasks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>CAN standards and bit rates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Supported CAN parameters are often limited or less clearly specified.<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Supports CAN 2.0A \/ 2.0B and bit rates from 10 kbit\/s to 1 Mbit\/s.<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Offers greater flexibility when integrating into different CAN systems and existing installations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Industrial use<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often used for simple control tasks<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Designed for industrial automation and CAN networks<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Suitable for demanding applications with high requirements for stability and continuous operation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>USB Standard<\/strong><\/td>\n<td data-label=\"Market Comparison\">usually only USB-A \/ B<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Thanks to USB-C, it is significantly more modern and faster than typical USB I\/O boards<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Improves compatibility with current devices and simplifies integration.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Number of USB modules that can be used simultaneously<\/strong><\/td>\n<td data-label=\"Market Comparison\">1\u20134 modules, often without proper management<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Up to 16 modules per system<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Enables larger system configurations without additional distributors or expansion devices.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Analog inputs<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Current and voltage measurement<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some providers offer only voltage or only current<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Both signal types supported<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Enables the use of different sensor types without additional signal converters, thereby reducing hardware and wiring costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Resolution and accuracy<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 8\u201312 bit<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">High\u2011resolution 16\u2011bit for precise signal control<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Improves measurement accuracy and enables reliable evaluation of even small signal changes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware filtering<\/strong><\/td>\n<td data-label=\"Market Comparison\">External filtering required<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Smoothing and averaging directly in the module; filters adjustable<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Reduces measurement noise and ensures more stable input values without external filter hardware.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often, there is no isolation from the power supply<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Electrical isolation for the module&#8217;s power supply<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Protects connected systems from interference voltages and prevents interactions between measurement circuits and the power supply.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation between all channels<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often a common reference potential for all channels<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Galvanic isolation up to 500 V between all channels<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Enables measurements in environments with different reference potentials and prevents compensation currents between channels.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-AD2-16ISO<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-CAN-AD2-16ISO\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the CAN converter modules with galvanically isolated inputs for industrial and test bench measurements\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Process optimization through automation:<br \/><\/strong>Thanks to the integrated auto TX\/RX mode, modules can communicate directly with each other and exchange signals\u2014without the need for an additional control PC.<\/li>\n<li><strong>Decentralized CAN network nodes:<br \/><\/strong>The CAN converter module with galvanically isolated inputs for industrial and test bench measurements is suitable as a decentralized CAN I\/O unit within industrial control architectures. Via the CAN bus, states and data are reliably transmitted and distributed to other system participants, enabling the integration of remote system areas into a centralized structure.<\/li>\n<li><strong>Industrial sensor data acquisition:<br \/><\/strong>The analog inputs are suitable for precise acquisition of physical measurement variables such as pressure, temperature, or fill levels in industrial processes.<\/li>\n<li><strong>Laboratory and testing technology:<br \/><\/strong>The CAN converter module with galvanically isolated inputs for industrial and test bench measurements is ideally suited for experimental setups, data acquisition, and calibrations where high accuracy and reliability are essential.<\/li>\n<li><strong>Process data acquisition in production:<br \/><\/strong>Ideal for capturing continuous process values in manufacturing plants in order to make production workflows transparent and analyzable.<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The UC-CAN A\/D module offers two analog inputs with 16- or 18-bit resolution for precise measurement of voltages and currents. Electrical isolation up to 1 kV ensures a high level of safety in industrial applications. Flexible ranges such as 0\u201310 V or 4\u201320 mA make the module ideal for sensor applications and test benches. Using the open CAN protocol, it integrates reliably into existing systems and delivers stable measurement data.<br \/>\n<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<li>Electrically isolated up to 1.5 kV<\/li>\n<\/ul>\n<h3>Wi-Fi interface:<\/h3>\n<ul>\n<li>Wi-Fi connection available<\/li>\n<li>WPS feature<\/li>\n<\/ul>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>CAN interface:<\/h3>\n<ul>\n<li>CAN interface according to ISO 11898<\/li>\n<li>Open CAN protocol<\/li>\n<li>RAW CAN\/J1939<\/li>\n<li>Automatic transmit\/receive mode<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>16-bit analog inputs:<\/h3>\n<ul>\n<li>Design: single-ended<\/li>\n<li>16-bit resolution per channel<\/li>\n<li>Voltage ranges: 0\u20135 V, 0\u201310 V, 0\u201320 V, 0\u201340 V, \u00b15 V, \u00b110 V, \u00b120 V, \u00b140 V<\/li>\n<li>Current ranges: 0\u201320 mA, 4\u201320 mA, 0\u201324 mA<\/li>\n<li>Channel-to-channel isolation: max. 1 kV AC<\/li>\n<li>Electrical isolation for the power supply: max. 500 V<\/li>\n<li>A\/D converter conversion time: 4 \u00b5s<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-CAN-AD2-16ISO\">\n<h2>Product Description \u2013 CAN converter module with galvanically isolated inputs for industrial and test bench measurements<\/h2>\n<p>The UC-CAN A\/D converter module was specifically developed for precise measurement tasks in industrial CAN networks. With two galvanically isolated 16\/18-bit analog inputs, it enables high-resolution measurement of voltages and currents\u2014even in noisy environments. The galvanic isolation reliably protects connected systems from potential differences and ensures maximum operational safety.<br \/>\nThe CAN converter module with galvanically isolated inputs for industrial and test bench measurements supports flexible CAN communication via RAW CAN and J1939 with an adjustable baud rate. The automatic TX\/RX mode also facilitates integration into existing measurement and control architectures. Thanks to robust electronics, an industrial-grade design, and precise signal processing, the device is ideally suited for demanding applications such as test benches, sensor data acquisition, or process monitoring.<br \/>\nThanks to its compact design, the UC-CAN-AD2-16ISO can be easily integrated into distributed measurement systems. The high resolution enables precise analysis of even the smallest signal changes\u2014a decisive advantage for industrial automation, quality assurance, and research. With its reliable performance, clearly structured CAN parameterization, and durable hardware, the UC-CAN A\/D module offers a professional solution for precise measurement tasks in modern CAN-based systems.<\/p>\n<h3>CAN interface with flexible USB configuration<\/h3>\n<p>The CAN interface of the UC-CAN-AD2-16ISO is based on the CAN 2.0A\/B standard and enables robust, error-resistant communication via RAW CAN or J1939 in industrial networks. It supports the typical multi-master CAN bus architecture, allowing multiple nodes to efficiently exchange data without a central controller. The bit rate is flexibly configurable, enabling the CAN converter module with galvanically isolated inputs for industrial and test bench measurements to be easily adapted to different network speeds and system environments. Communication is handled via standardized CAN telegrams with event-driven data transmission for fast and reliable signal processing.<br \/>\nThe entire CAN configuration, including TX\/RX behavior, is conveniently carried out via the integrated USB interface on a PC. This allows parameters such as bus speed and message handling to be quickly configured and tested. This combination of CAN and USB connectivity significantly simplifies commissioning and reduces integration and diagnostic effort.<\/p>\n<h3>Flexible CAN control via auto TX\/RX and DELIB command mode<\/h3>\n<p>The UC-CAN-AD2-16ISO can generally be controlled using two operating modes: Auto TX\/RX mode and DELIB command mode. In Auto TX\/RX mode, the module can automatically transmit and receive CAN packets without requiring a permanently connected control PC. Both RAW CAN and J1939 are supported.<br \/>\nAlternatively, DELIB command mode provides direct register-based access via a manufacturer-specific CAN protocol, allowing specific commands to be transmitted to the CAN converter module with galvanically isolated inputs for industrial and test bench measurements. Read and write operations are implemented using defined CAN IDs and structured data packets, enabling highly flexible and precise control.<br \/>\nDepending on the product variant, these control modes can be conveniently configured on a PC via the integrated USB or Ethernet interface. The corresponding tool allows parameters such as communication behavior, TX\/RX logic and the DELIB command structure to be easily configured and tested. This enables the CAN converter module with galvanically isolated inputs for industrial and test bench measurements to be quickly adapted to different applications and efficiently integrated into existing CAN systems.<\/p>\n<h3>Accurate and interference-resistant analog signal acquisition for industrial applications<\/h3>\n<p>The analog inputs of the UC-CAN-AD2-16ISO are designed for precise acquisition of voltage and current signals in industrial applications and provide two independently usable measurement channels. They support common input signals such as \u00b140 V as well as current signals in the ranges 0\u201320 mA, 4\u201320 mA, and 0\u201324 mA, enabling flexible adaptation to various sensors. The inputs on the CAN converter module with galvanically isolated inputs for industrial and test bench measurements are implemented with high impedance, ensuring that connected signal sources are only minimally loaded and stable measurement values are guaranteed. Due to the high resolution of the conversion, even small signal changes are reliably detected and accurately represented. In addition, galvanic isolation of the input stages provides safe decoupling between the measurement system and the signal source, effectively reducing interference and potential differences. As a result, the analog inputs are particularly well suited for demanding measurement and monitoring tasks in industrial environments.<\/p>\n<h3>Event Control \u2013 event-based automation<\/h3>\n<p>The Event Control function enables direct, event-driven processing of both digital and analog signals in the CAN converter module with galvanically isolated inputs for industrial and test bench measurements, without requiring cyclic polling by higher-level software. Digital signal transitions can immediately trigger internal actions, while analog signals can generate events based on defined thresholds, measurement ranges, or significant value changes. This allows responses to be implemented much faster and more resource-efficiently compared to traditional polling-based processing.<br \/>\nThe event logic can be flexibly configured, enabling both simple switching conditions and more complex dependencies between digital and analog signals. In addition, functions such as filtering, hysteresis, and threshold monitoring are available to ensure stable and reliable trigger conditions.<br \/>\nAs a result, Event Control is particularly well suited for automation applications where signals must be evaluated intelligently and processed immediately.<\/p>\n<h3>M2M communication \u2013 direct device-to-device networking<\/h3>\n<p>The M2M (machine-to-machine) function enables direct communication between multiple modules or systems without a central control unit. States and events can be automatically exchanged and synchronized between devices, allowing the creation of distributed and autonomously operating automation structures. Communication is carried out via defined protocols and can be flexibly integrated into existing system architectures. As a result, M2M is particularly well suited for connected industrial and IoT applications.<\/p>\n<h3>Robust industrial design with a well-engineered connection and mounting architecture<\/h3>\n<p>The CAN converter module with galvanically isolated inputs for industrial and test bench measurements is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-CAN-AD2-16ISO, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm\u00b2. In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.<\/p>\n<h3>Application and Benefits<\/h3>\n<p>The UC-CAN-AD2-16ISO offers a reliable and long-term solution for industrial automation tasks. With stable drivers, clear documentation, and the ICT diagnostic tool, the module can be quickly integrated and efficiently maintained. The robust electronics, developed in Germany and featuring galvanic isolation, ensure high operational reliability, while direct developer support and regular updates guarantee sustainable use in professional environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"<p>The UC-CAN A\/D module offers two galvanically isolated 16\/18-bit inputs for precise measurement of voltages and currents via an open CAN interface. Ideal for industrial applications and test benches, e.g., for acquiring sensor signals or monitoring process variables. Thanks to its Auto RX\/TX mode and robust design, the module is perfectly suited for reliable measurement tasks in CAN-based systems.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW CAN CAN MESSAGES BE PROCESSED CYCLICALLY OR EVENT-DRIVEN?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The CAN converter module with galvanically isolated inputs for industrial and test bench measurements supports both cyclic communication processes and event-driven triggers. CAN messages can be transmitted at fixed intervals or triggered by predefined events. This allows communication to be optimally adapted to the specific application.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE ICT TOOL BE USED WITHOUT ANY CUSTOM PROGRAMMING?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, the ICT-Tool enables direct access to the modules without the need for custom software development. This allows functions, interfaces, and I\/O states to be quickly tested and verified.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN C#?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes. In the download section of our website, we provide a package with ready-made programming examples for controlling our modules in C#.\nThe package also includes sample code for other supported programming languages.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT COMMISSIONING THE UC-CAN-AD2-16ISO?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All important information regarding commissioning, wiring, configuration, and initial setup is described in the module manual. The document can be downloaded via the \"Downloads and Manuals\" section on the product page or through the central download area of the homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND AN OVERVIEW OF ALL AVAILABLE API COMMANDS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>A complete overview of all supported API commands can be found in the manual of the respective module. In addition, the API documentation is available on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25568026","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568026"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584305"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568026"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25568026"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25568026"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25568026"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}