{"id":25567974,"date":"2023-09-29T09:05:45","date_gmt":"2023-09-29T07:05:45","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/uc-can-16-18-bit-a-d-wandler-16-kanaelen\/"},"modified":"2026-09-14T10:15:46","modified_gmt":"2026-09-14T08:15:46","slug":"can-ad-converter-16-channels","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/can\/can-ad-converter-16-channels\/","title":{"rendered":"16-Channel CAN A\/D Converter * CAN 16\/18-bit A\/D converter &#8211; 16 channels"},"content":{"rendered":"<section class=\"product-description product-description-uc-can-ad16\">\n<h2>Product Description<\/h2>\n<h3>UC-CAN A\/D Converter for CAN-based data acquisition<\/h3>\n<p>The UC-CAN 16\/18-bit A\/D Converter \u2013 16-Channel CAN Bus Module is an industrial stand-alone module for acquiring analog measurement signals via CAN. The module is designed for applications in which voltages or currents need to be measured, digitized, and transmitted to a control, test bench, or evaluation environment in a decentralized manner.<\/p>\n<p>With 16 analog A\/D channels, selectable 16-bit or 18-bit resolution, and single-ended inputs, the UC-CAN-AD16-16\/18 is suitable for measurement tasks involving multiple sensor, transducer, or process signals at a single CAN node. Depending on the variant, different voltage or current ranges are available. This allows the module to be used for typical analog industrial signals in test benches, machines, systems, and laboratory setups.<\/p>\n<h3>System role in distributed CAN architectures<\/h3>\n<p>In a CAN-based automation or measurement architecture, the module serves as a decentralized analog acquisition module. Analog signals are captured directly at the measurement point, digitized within the module, and transmitted via the CAN interface to higher-level systems, other modules, or customer-specific applications.<\/p>\n<p>The open CAN protocol facilitates integration into custom software, gateways, test bench controllers, or existing CAN networks. The automatic transmit and receive mode supports applications in which CAN packets are to be processed autonomously or transmitted cyclically. This allows the UC-CAN-AD16-16\/18 to be used not only as a pure measurement module but also as an active component of a modular automation structure.<\/p>\n<h3>USB-C as an added benefit during commissioning and service<\/h3>\n<p>In addition to the CAN interface, the module features a USB-C interface. This is particularly useful for commissioning, parameterization, diagnostics, and service, as the module is not accessible exclusively via the CAN environment. USB-C can simplify access and speed up setup, especially in test setups, laboratory environments, or during initial configuration.<\/p>\n<p>The UC-CAN-AD16-16\/18 thus combines CAN-based field and system integration with additional local access for configuration and maintenance.<\/p>\n<h3>Signal Processing and Electrical Robustness<\/h3>\n<p>In industrial measurement environments, it is not only the number of channels that matters, but also the reliable processing of the input signals. Galvanic isolation up to 500 V supports use in plant environments with electrical interference and varying potential conditions.<\/p>\n<p>The software-based A\/D filter can smooth out electrical or electromagnetic disturbances in the measurement signal. The filtering is based on averaging and can be used, depending on the application, to stabilize measured values for monitoring, analysis, or further processing. This makes the module suitable for measurement tasks where repeatable and evaluable analog values are more important than pure raw signal acquisition.<\/p>\n<h3>Typical applications<\/h3>\n<p>The UC-CAN-AD16-16\/18 is suitable for industrial applications in which multiple analog signals need to be acquired and processed via CAN. Typical applications include:<\/p>\n<ul>\n<li>Test benches and test systems for acquiring sensor, voltage, or current signals<\/li>\n<li>Machine and plant monitoring with decentralized data acquisition<\/li>\n<li>Laboratory and development systems for test setups, calibration, and measurement data acquisition<\/li>\n<li>Industrial automation with integration of analog process values into control or SCADA environments<\/li>\n<li>Energy and consumption monitoring for monitoring analog measured variables<\/li>\n<li>M2M applications in which measured values are transmitted between modules or CAN participants<\/li>\n<\/ul>\n<h3>Integration, commissioning, and software integration<\/h3>\n<p>The CAN interface supports CAN 2.0A and CAN 2.0B, as well as multiple baud rates up to 1 Mbit\/s. This allows the module to be adapted to various CAN networks and existing system architectures. The additional USB-C interface supports local access for configuration, service, and diagnostics.<\/p>\n<p>Configuration and diagnostics are performed using the DEDITEC ICT tool. The DELIB driver library can be used for custom applications, including those written in C, C++, C#, Java, VB, and LabVIEW. This makes the module suitable for both traditional PC-based measurement systems and customer-specific software and test bench solutions.<\/p>\n<h3>Made in Germany, long-term availability, and direct support<\/h3>\n<p>The UC-CAN-AD16-16\/18 is a module manufactured in Germany by DEDITEC. For industrial projects, long-term reliability is just as important as technical functionality. The guaranteed 10-year availability, direct developer support, and lifetime updates for the DEDITEC system environment assist users with commissioning, maintenance, and long-term operation.<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<h2>Technical Specifications<\/h2>\n<p>The UC-CAN 16\/18-bit A\/D converter is a compact 16-channel CAN bus module designed to acquire analog voltage and current signals. With 16-bit or 18-bit resolution, a galvanically isolated CAN interface, open CAN protocol, and additional USB-C access, the module is suitable for measurement data acquisition, test benches, machine monitoring, and industrial automation.<\/p>\n<p>&nbsp;<\/p>\n<h3>At a glance<\/h3>\n<ul>\n<li>16-channel A\/D converter for analog voltage and current signals<\/li>\n<li>Resolution depending on the model: 16-bit or 18-bit per channel<\/li>\n<li>CAN bus module with CAN 2.0A \/ CAN 2.0B<\/li>\n<li>Open CAN protocol for integration into custom systems<\/li>\n<li>Electrically isolated CAN interface up to 500 V<\/li>\n<li>Additional USB-C interface for commissioning, service, and direct module access<\/li>\n<li>A\/D filter for smoothing out noise in the measurement signal<\/li>\n<li>Event control for simple if-then logic in the module memory<\/li>\n<li>Supply voltage: +12 V to +24 V DC<\/li>\n<li>Top-hat rail mounting for use in control cabinets<\/li>\n<\/ul>\n<h3>Interfaces and Communication<\/h3>\n<ul>\n<li>CAN interface via 9-pin D-Sub connector<\/li>\n<li>Support for CAN 2.0A and CAN 2.0B<\/li>\n<li>CAN bit rates from 10 kbit\/s to 1 Mbit\/s<\/li>\n<li>Open CAN protocol for control, test bench, and measurement systems<\/li>\n<li>Auto TX\/RX mode for automatic processing of CAN packets<\/li>\n<li>USB-C as an additional interface for parameterization, testing, and service<\/li>\n<\/ul>\n<h3>Analog Inputs<\/h3>\n<ul>\n<li>16 analog A\/D channels in single-ended configuration<\/li>\n<li>16-bit version for voltage and current measurement ranges<\/li>\n<li>18-bit version for precise voltage measurements with \u00b15 V and \u00b110 V<\/li>\n<li>Suitable for acquiring analog sensor signals in measurement and automation environments<\/li>\n<li>Input resistance: &gt; 500 k\u03a9<\/li>\n<li>A\/D converter conversion rate: 4 \u00b5s<\/li>\n<\/ul>\n<h3>Signal Processing and A\/D Filters<\/h3>\n<ul>\n<li>Software-based A\/D filter for smoothing electrical and electromagnetic interference<\/li>\n<li>Filtering via averaging of multiple measurements<\/li>\n<li>78 conversions per second when converting all 16 A\/D channels without an A\/D filter<\/li>\n<li>48 conversions per second when converting all 16 A\/D channels with A\/D filter level 10<\/li>\n<li>Filter level adjustable via DELIB commands<\/li>\n<\/ul>\n<h3>Automation and Event Control<\/h3>\n<ul>\n<li>Event Control for linking measured values to actions<\/li>\n<li>If-then logic can be stored in the module memory using the ICT tool<\/li>\n<li>Suitable for simple monitoring, control, and regulation tasks without the need for an additional control PC<\/li>\n<li>Practical applications include test benches, limit value monitoring, and decentralized data acquisition<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment<\/h3>\n<ul>\n<li>Power supply: +12 V to +24 V DC<\/li>\n<li>Electrical isolation from power supply: max. 500 V<\/li>\n<li>DIN rail mounting: 35 x 7.5 mm<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C<\/li>\n<li>Dimensions: 120 mm x 22.5 mm x 111 mm (H x W x D)<\/li>\n<\/ul>\n","protected":false},"featured_media":25584301,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[244,1577],"product_tag":[],"class_list":{"0":"post-25567974","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-analoge-eingaenge","7":"einausgang-ai16","8":"konfigurations_interface-usb-en","9":"schnittstelle-can-en","10":"product_cat-uc","11":"product_cat-can","12":"pa_art-der-eingaenge-strom-0-24ma_en","13":"pa_art-der-eingaenge-spannung-0-20v_en","14":"pa_art-der-eingaenge-spannung-0-10v_en","15":"pa_art-der-eingaenge-spannung-0-40v_en","16":"pa_aufloesung-ad-modul-mit-18-bit-aufloesung_en","17":"pa_aufloesung-ad-modul-mit-16-bit-aufloesung_en","19":"first","20":"instock","21":"taxable","22":"shipping-taxable","23":"purchasable","24":"product-type-variable"},"acf":{"produktvergleich_rest_api":"","zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square;\">\n<li><strong>Test benches and test systems<br \/>\n<\/strong>Optimal integration into test environments is enabled by the CAN interface of the UC-CAN-AD16-16\/18, supporting analysis, simulation, and validation processes.:<\/li>\n<li><strong>Machine-to-machine communication (M2M)<br \/>\n<\/strong>Thanks to the integrated CAN M2M function of the UC-CAN-AD16-16\/18, devices can communicate directly with each other. CAN telegrams are automatically transmitted between sender and receiver modules, allowing complete process chains to be controlled without a higher-level PLC or PC. Ideal for autonomous machine networks.:<\/li>\n<li><strong>Building and environmental automation<br \/>\n<\/strong>Continuous monitoring of climate and environmental sensors in large building complexes is easily possible with the UC-CAN-AD16-16\/18.:<\/li>\n<li><strong>Laboratory and testing technology<br \/>\n<\/strong>The Modul is ideally suited for experimental setups, data acquisition, and calibrations where high accuracy and reliability are essential.:<\/li>\n<li><strong>Machine and plant networking<br \/>\n<\/strong>Integration of analog measurement values into control and SCADA systems.:<\/li>\n<li><strong>Energy and consumption monitoring<br \/>\n<\/strong>The inputs of the UC-CAN-AD16-16\/18 can be used to record current, voltage, or power values in order to monitor energy flows in systems.:<\/li>\n<\/ul>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>&nbsp;<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<\/ul>\n<h3>Wi-Fi interface:<\/h3>\n<ul>\n<li>Wi-Fi connection available<\/li>\n<li>WPS feature<\/li>\n<\/ul>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>CAN interface:<\/h3>\n<ul>\n<li>CAN interface according to ISO 11898<\/li>\n<li>Open CAN protocol (RAW CAN)<\/li>\n<li>Automatic transmit\/receive mode<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>16-bit analog inputs:<\/h3>\n<ul>\n<li>Design: single-ended<\/li>\n<\/ul>\n<h3>18-bit analog inputs:<\/h3>\n<ul>\n<li>Design: single-ended<\/li>\n<\/ul>\n","produktvergleich":"<h2>Comparison: UC-CAN 16\/18-bit A\/D converter as a 16-channel CAN bus module<\/h2>\n<p>The following comparison provides a technical overview of the UC-CAN 16\/18-bit A\/D converter: a CAN bus module with 16 analog inputs, selectable 16- or 18-bit resolution, open CAN protocol, galvanic isolation, and measurement ranges for voltage and current signals. The table is designed to facilitate a quick assessment for purchasing, development, test bench construction, and industrial automation.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"g6g-respo-table\">\n<table style=\"width: 99.7632%; height: 1313px;\">\n<tbody>\n<tr class=\"table-headline-row\" style=\"height: 76px;\">\n<td style=\"width: 1478px; height: 76px;\" colspan=\"4\">\n<h3>Produkttyp, CAN-Kommunikation und Systemintegration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\" style=\"height: 23px;\">\n<th style=\"color: #555555; width: 184px; height: 23px;\">Feature<\/th>\n<th style=\"color: #555555; width: 431px; height: 23px;\">Market Comparison<\/th>\n<th style=\"color: #555555; width: 371px; height: 23px;\">UC-CAN-AD16-16\/18<\/th>\n<th style=\"color: #555555; width: 492px; height: 23px;\">Practical benefits<\/th>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Product Type<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Many CAN I\/O modules are universal mixed-signal modules that support multiple signal types.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">CAN A\/D converter with a focus on 16 analog inputs.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Ideal when a large number of analog measurement signals need to be specifically acquired and processed via CAN.<\/td>\n<\/tr>\n<tr style=\"height: 71px;\">\n<td style=\"color: #555555; width: 184px; height: 71px;\" data-label=\"Merkmal\"><strong>CAN bus interface<\/strong><\/td>\n<td style=\"width: 431px; height: 71px;\" data-label=\"Marktvergleich\">For CAN modules, the supported CAN versions, bit rates, and protocol interfaces vary significantly depending on the manufacturer.<\/td>\n<td style=\"width: 371px; height: 71px;\" data-label=\"UC-CAN-AD16-16\/18\">CAN 2.0A or CAN 2.0B with selectable bit rates up to 1 Mbit\/s.<\/td>\n<td style=\"width: 492px; height: 71px;\" data-label=\"Praxisnutzen\">Facilitates integration into existing CAN networks, test benches, control systems, and data loggers.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>CAN protocol<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">In some cases, closed or proprietary protocols are used.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">Open CAN protocol.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Useful for custom CAN implementations, customer-specific telegrams, gateways, and PC-based measurement systems.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Automatic CAN operation<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">With simple CAN I\/O modules, communication often has to be controlled entirely externally.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">Automatic transmission and reception mode for CAN packets.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Reduces the programming effort required for recurring transmission and reception tasks in the CAN network.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\" style=\"height: 76px;\">\n<td style=\"width: 1478px; height: 76px;\" colspan=\"4\">\n<h3>Analog Inputs, Resolution, and Measurement Ranges<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\" style=\"height: 23px;\">\n<th style=\"width: 184px; height: 23px;\">Feature<\/th>\n<th style=\"width: 431px; height: 23px;\">Market Comparison<\/th>\n<th style=\"width: 371px; height: 23px;\">UC-CAN-AD16-16\/18<\/th>\n<th style=\"width: 492px; height: 23px;\">Practical benefits<\/th>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Number of analog inputs<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Compact CAN A\/D modules often offer fewer analog channels or distribute measurement points across multiple devices.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">16 A\/D channels, single-ended.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Multiple sensor, transmitter, or process signals can be consolidated into a single CAN node.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>A\/D resolution<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Many standard modules operate with a fixed or lower A\/D resolution.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">16-bit or 18-bit resolution per channel.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">The resolution can be selected to suit the measurement task, such as for standard measurements or finer signal resolution.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Voltage measurement ranges<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Some CAN A\/D modules support only specific voltage ranges or require separate versions for this purpose.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">16-bit version: 0\u20135 V, 0\u201310 V, 0\u201320 V, 0\u201340 V, \u00b15 V, \u00b110 V, \u00b120 V, \u00b140 V. 18-bit version: \u00b15 V, \u00b110 V.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Voltage signals from various sensors and transducers can be acquired as needed for the application.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Current measurement ranges<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Current measurement ranges such as 4\u201320 mA are not directly available on all CAN A\/D modules.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">16-Bit-version: 0\u201320 mA, 4\u201320 mA, 0\u201324 mA.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Industrial current signals from transmitters and transducers can be integrated directly into the CAN-based data acquisition system.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>A\/D filter<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Signal smoothing is often performed externally or in the higher-level software.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">Software-based A\/D filter with averaging; adjustable filter level.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Noisy measurement signals can be smoothed before they are processed further in the CAN system.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Conversion rate<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">For many modules, the usable measurement rate depends on the number of channels, filtering, and bus communication.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">A\/D converter: 4 \u00b5s. Module: 78 conversions\/s at filter level 0, 48 conversions\/s at filter level 10.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Allows for a technical trade-off between faster updates and greater signal smoothing.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\" style=\"height: 76px;\">\n<td style=\"width: 1478px; height: 76px;\" colspan=\"4\">\n<h3>Industrial Applications, Protection, and Installation<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\" style=\"height: 23px;\">\n<th style=\"width: 184px; height: 23px;\">Feature<\/th>\n<th style=\"width: 431px; height: 23px;\">Market Comparison<\/th>\n<th style=\"width: 371px; height: 23px;\">UC-CAN-AD16-16\/18<\/th>\n<th style=\"width: 492px; height: 23px;\">Practical benefits<\/th>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Electrical isolation<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Galvanic isolation is not always available in CAN A\/D modules, or is implemented only for certain areas.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">Electrical isolation for the power supply: max. 500 V.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Helps address potential differences and enhances operational safety in industrial measurement environments.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Power supply<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Many industrial I\/O modules are designed for a fixed 24-V DC power supply.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">+12 V to +24 V DC.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Suitable for use in typical 12-V and 24-V DC environments, such as test benches, machines, and mobile measurement setups.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Control Panel Assembly<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Depending on the module design, additional adapters, desktop enclosures, or special mounting brackets may be required.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">Top-hat rail mount 35 \u00d7 7.5 mm; dimensions 120 \u00d7 22.5 \u00d7 111 mm.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Facilitates integration into control cabinets, test benches, laboratory setups, and modular automation systems.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Connectors<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Wiring and maintenance depend heavily on the type of terminal, the locking mechanism, and the protection against incorrect insertion.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">WAGO terminal blocks, 100% protected against incorrect insertion, with eject and locking mechanisms.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Supports safe wiring and simplifies maintenance, replacement, and commissioning.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Operating temperature<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Temperature ranges must be tested separately for measurement modules located in the control cabinet or test bench.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">+10 \u00b0C to +50 \u00b0C.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Suitable for typical industrial indoor, control cabinet, and laboratory environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\" style=\"height: 76px;\">\n<td style=\"width: 1478px; height: 76px;\" colspan=\"4\">\n<h3>Software, Diagnostics, and Commissioning<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\" style=\"height: 23px;\">\n<th style=\"width: 184px; height: 23px;\">Feature<\/th>\n<th style=\"width: 431px; height: 23px;\">Market Comparison<\/th>\n<th style=\"width: 371px; height: 23px;\">UC-CAN-AD16-16\/18<\/th>\n<th style=\"width: 492px; height: 23px;\">Practical benefits<\/th>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Configuration<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">CAN modules are often configured using manufacturer-specific tools or directly via protocol commands.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">Configuration via the ICT tool.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">CAN communication, automatic processing, and module parameters can be tested prior to integration.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Software integration<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Depending on the manufacturer, integration is often limited to specific platforms or libraries.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">Control via DELIB commands and documented CAN functions.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Facilitates integration into your own measurement, test bench, and automation software.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Diagnosis and Testing<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">With simple modules, diagnostic and testing capabilities are often limited.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">ICT tool for configuration, testing, diagnostics, and firmware updates.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Supports commissioning, troubleshooting, and maintenance without the need for proprietary diagnostic software.<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"color: #555555; width: 184px; height: 47px;\" data-label=\"Merkmal\"><strong>Documentation and Downloads<\/strong><\/td>\n<td style=\"width: 431px; height: 47px;\" data-label=\"Marktvergleich\">Manuals, software packages, and firmware files are not available directly from all manufacturers.<\/td>\n<td style=\"width: 371px; height: 47px;\" data-label=\"UC-CAN-AD16-16\/18\">Manual, ICT\/DELIB software packages, and firmware flash file package in the Downloads section.<\/td>\n<td style=\"width: 492px; height: 47px;\" data-label=\"Praxisnutzen\">Speeds up the technical testing, implementation, and subsequent maintenance of the CAN measurement system.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","produktbeschreibung_rest_api":"","sge_text":"<p>The UC-CAN 16\/18-bit A\/D converter is an industrial 16-channel CAN bus module for the decentralized acquisition of analog voltage and current signals. The UC-CAN-AD16-16\/18 module provides 16 single-ended A\/D channels and is available with 16-bit or 18-bit resolution, depending on the variant. The measured values are transmitted via CAN 2.0A\/2.0B using an open CAN protocol and automatic TX\/RX mode. Galvanic isolation up to 500 V, software-based A\/D filtering, and event control support its use in industrial measurement data acquisition, test benches, machine monitoring, and CAN-based automation systems.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","zusatztext":"<h2>Typical applications for the UC-CAN 16\/18-bit A\/D converter<\/h2>\n<p>The UC-CAN 16\/18-bit A\/D Converter \u2013 16-Channel CAN Bus Module is suitable for industrial applications in which analog measurement signals need to be acquired and transmitted via the CAN bus to controllers, IPCs, gateways, data loggers, or SCADA systems. With 16 analog A\/D channels, selectable 16- or 18-bit resolution, and galvanically isolated CAN connectivity, the module is particularly well-suited for decentralized measurement tasks in machines, plants, test benches, mobile measurement systems, and distributed automation environments. The voltage and current ranges listed on the page, as well as the open CAN protocol, support integration into customer-specific measurement and control architectures.<\/p>\n<p>&nbsp;<\/p>\n<h3>Suitable for<\/h3>\n<ul>\n<li>Machine and Plant Engineering<\/li>\n<li>Control Panel Construction and Industrial Control Technology<\/li>\n<li>Test Benches, Test Systems, and Measurement Data Acquisition<\/li>\n<li>Laboratory, Development, and Research Systems<\/li>\n<li>Machine and Plant Monitoring<\/li>\n<li>Mobile Measurement Systems<\/li>\n<li>Decentralized CAN Measurement Networks and Retrofit Applications<\/li>\n<li>CAN-Based Automation and SCADA Systems<\/li>\n<\/ul>\n<h3>Typical applications<\/h3>\n<ul>\n<li>Acquiring analog sensor, transmitter, and transducer signals<\/li>\n<li>Transmitting analog measurement values via CAN to controllers, IPCs, gateways, data loggers, or SCADA systems<\/li>\n<li>Bundling multiple analog measurement points into a single CAN node<\/li>\n<li>Integration of existing sensor technology into CAN-based automation and measurement systems<\/li>\n<li>Monitoring of process values in machines, plants, and test environments<\/li>\n<li>Decentralized measurement data acquisition in stationary and mobile industrial or test systems<\/li>\n<li>Retrofitting analog measurement points in existing CAN architectures<\/li>\n<\/ul>\n<h3>Typical measurement and signal processing tasks<\/h3>\n<ul>\n<li>A\/D conversion of analog input signals with 16- or 18-bit resolution<\/li>\n<li>Acquisition of up to 16 single-ended analog signals<\/li>\n<li>Measurement of voltage signals in the ranges listed on the page: 0\u20135 V, 0\u201310 V, 0\u201320 V, 0\u201340 V, +5 V, +10 V, +20 V, and +40 V<\/li>\n<li>Measurement of current signals in the ranges 0\u201320 mA, 4\u201320 mA, and 0\u201324 mACAN-based transmission of analog measured values via an open CAN protocol<\/li>\n<li>Use of automatic transmit\/receive mode for CAN communication<\/li>\n<li>Electrically isolated CAN connection for more robust integration into industrial environments<\/li>\n<\/ul>\n","faq_rest_api":""},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25567974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25567974"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584301"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25567974"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25567974"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25567974"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25567974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}