{"id":25567960,"date":"2023-09-29T10:50:14","date_gmt":"2023-09-29T08:50:14","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/uc-can-mit-4-thermoelement-eingaengen-des-typ-k\/"},"modified":"2026-08-14T16:07:11","modified_gmt":"2026-08-14T14:07:11","slug":"can-thermocouple-inputs-4-temp-input","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/uc\/can\/can-thermocouple-inputs-4-temp-input\/","title":{"rendered":"CAN thermocouples * CAN with 4 type K thermocouple inputs"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":25584033,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[245,1584],"product_tag":[],"class_list":{"0":"post-25567960","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-temp4","7":"einausgang-temperatur-eingaenge","8":"konfigurations_interface-usb-en","9":"schnittstelle-can-en","10":"product_cat-uc","11":"product_cat-can","12":"pa_aufloesung-ad-modul-mit-16-bit-aufloesung_en","13":"pa_aufloesung-ad-modul-mit-18-bit-aufloesung_en","15":"first","16":"instock","17":"taxable","18":"shipping-taxable","19":"purchasable","20":"product-type-simple"},"acf":{"zusatztext_rest_api":"<h2>Typical Application Areas:<\/h2>\n<ul style=\"list-style-type: square\">\n<li><strong>Test benches and test systems:<br \/><\/strong>Optimal integration into test environments is enabled by the CAN interface of the UC-CAN-U-THERMO4_K, supporting analysis, simulation, and validation processes.<\/li>\n<li><strong>Decentralized automation via CAN bus networks:<br \/><\/strong>The CAN thermocouple modul is ideally suited for use in distributed automation systems in which multiple CAN nodes communicate with each other. Through the CAN interface, data packets can be exchanged directly between devices without a central controller. This enables efficient implementation of modular machine and system architectures.<\/li>\n<li><strong>Real-time communication on the CAN bus:<br \/><\/strong>Direct CAN communication via RAW CAN or J1939 enables data to be transmitted between system components without intermediate processing \u2013 quickly, efficiently, and with deterministic transmission behavior.<\/li>\n<li><strong>Process monitoring:<br \/><\/strong>Precise temperature control in industrial processes to ensure stable operations is enabled by the CAN thermocouple modul.<\/li>\n<li><strong>Quality control:<br \/><\/strong>Ensuring consistent product quality through accurate and repeatable temperature measurements.<\/li>\n<li><strong>Research and development:<br \/><\/strong>Use in laboratories and test environments for scientific experiments and test setups is also supported by the UC-CAN-U-THERMO4_K module.<\/li>\n<li><strong>Energy and environmental technology:<br \/><\/strong>Monitoring of temperatures in heating, cooling, or environmental systems for efficient operation.<\/li>\n<li><strong>Building and facility management:<br \/><\/strong>Integration into building management systems as well as industrial plant control for temperature monitoring is carried out seamlessly via the CAN thermocouple modul.<\/li>\n<\/ul>\n","zusatztext":"","produktbeschreibung_rest_api":"<section class=\"product-description product-description-UC-CAN-U-THERMO4_K\">\n<h2>Product Description \u2013 CAN thermocouple modul<\/h2>\n<p>The UC-CAN-U-THERMO4_K temperature module was specifically designed for precise temperature measurement in industrial CAN networks. With four inputs for Type K CAN thermocouples, the module enables high-resolution measurements across a wide temperature range. The integrated galvanic isolation reliably protects connected systems from interference and potential differences, ensuring that measured values remain stable and reproducible even in demanding industrial environments.<br \/>\nTemperature measurement is performed via a galvanically isolated CAN interface with an adjustable baud rate and automatic RX\/TX mode. This allows the module to be easily integrated into existing measurement, test, and automation systems. An integrated cold junction compensation ensures that thermocouple measurements remain precise even under changing environmental conditions\u2014a decisive advantage for industrial applications where temperature data is critical to safety or quality.<br \/>\nTypical applications include test benches where temperature profiles are analyzed or thermal loads are monitored, as well as process plants where temperature values are required for control, monitoring, or documentation. Thanks to its compact form factor and industrial-grade design, the CAN thermocouple modul is ideally suited for distributed measurement systems, laboratory environments, and automated manufacturing processes.<br \/>\nWith its combination of high measurement accuracy,<\/p>\n<h3>CAN interface with flexible USB configuration<\/h3>\n<p>The CAN interface of the UC-CAN-U-THERMO4_K is based on the CAN 2.0A\/B standard and enables robust, error-resistant communication via RAW CAN or J1939 in industrial networks. It supports the typical multi-master CAN bus architecture, allowing multiple nodes to efficiently exchange data without a central controller. The bit rate is flexibly configurable, enabling the CAN thermocouple modul to be easily adapted to different network speeds and system environments. Communication is handled via standardized CAN telegrams with event-driven data transmission for fast and reliable signal processing.<br \/>\nThe entire CAN configuration, including TX\/RX behavior, is conveniently carried out via the integrated USB interface on a PC. This allows parameters such as bus speed and message handling to be quickly configured and tested. This combination of CAN and USB connectivity significantly simplifies commissioning and reduces integration and diagnostic effort.<\/p>\n<h3>Flexible CAN control via auto TX\/RX and DELIB command mode<\/h3>\n<p>The UC-CAN-U-THERMO4_K can generally be controlled using two operating modes: Auto TX\/RX mode and DELIB command mode. In Auto TX\/RX mode, the module can automatically transmit and receive CAN packets without requiring a permanently connected control PC. Both RAW CAN and J1939 are supported.<br \/>\nAlternatively, DELIB command mode provides direct register-based access via a manufacturer-specific CAN protocol, allowing specific commands to be transmitted to the CAN thermocouple modul. Read and write operations are implemented using defined CAN IDs and structured data packets, enabling highly flexible and precise control.<br \/>\nThese control modes can be conveniently configured on a PC via the integrated USB interface. The corresponding tool allows parameters such as communication behavior, TX\/RX logic and the DELIB command structure to be easily configured and tested. This enables the CAN thermocouple modul to be quickly adapted to different applications and efficiently integrated into existing CAN systems.<\/p>\n<h3>High-precision temperature measurement with K-type thermocouple inputs for demanding industrial applications<\/h3>\n<p>The four type K thermocouple inputs enable precise and reliable temperature measurement across a very wide range from -200 \u00b0C to +1350 \u00b0C. The CAN thermocouple modul is specifically designed for direct connection of K-type thermocouples and delivers stable measurement values even under changing environmental conditions.<br \/>\nThanks to the integrated 14-bit A\/D converter, a high resolution of 0.25 \u00b0C is achieved, allowing even the smallest temperature changes to be captured accurately. An integrated cold-junction compensation further improves measurement accuracy by automatically compensating for temperature influences at the connection points.<br \/>\nThe UC-CAN-U-THERMO4_K also features galvanic isolation of the measurement channels, ensuring high noise immunity and reliable operation in industrial environments. Overall, the module provides a robust and precise solution for demanding temperature monitoring applications.<\/p>\n<h3>M2M communication \u2013 direct device-to-device networking<\/h3>\n<p>The M2M (machine-to-machine) function enables direct communication between multiple modules or systems without a central control unit. States and events can be automatically exchanged and synchronized between devices, allowing the creation of distributed and autonomously operating automation structures. Communication is carried out via defined protocols and can be flexibly integrated into existing system architectures. As a result, M2M is particularly well suited for connected industrial and IoT applications.<\/p>\n<h3>Robust industrial design with a well-engineered connection and mounting architecture<\/h3>\n<p>The CAN thermocouple modul is housed in a compact DIN rail enclosure specifically designed for control cabinet use, enabling space-saving integration into industrial systems. With a housing width of 22.5 mm, it supports high packing density while still ensuring good accessibility to all connections. For electrical wiring of the UC-CAN-U-THERMO4_K, a pluggable WAGO spring-clamp system is used, enabling tool-free and vibration-resistant installation and supporting conductor cross-sections of up to 1.5 mm\u00b2. In addition, a separate 5-pin connector is provided for the power supply, ensuring a clear separation between signal and operating voltage. The entire connection architecture is designed for misconnection protection and fast maintainability, offering clear advantages during service and commissioning processes. Overall, the design combines a robust mechanical structure with a practical, modular wiring concept for continuous industrial operation.<\/p>\n<h3>User Benefits and Practical Application<\/h3>\n<p>The UC-CAN-U-THERMO4_K offers a practical solution for industrial control and monitoring tasks. Its rugged, galvanically isolated electronics ensure reliable operation, while the documentation, drivers, and ICT diagnostic tool enable quick integration. Thanks to regular updates and direct developer support, the module remains operational over the long term and supports sustainable planning in professional environments.<br \/>\n<br \/>\n<\/section>\n","sge_text":"<p>The UC-CAN-U-THERMO4_K thermocouple module features four inputs for Type K CAN thermocouples and enables precise temperature measurements in industrial applications. It is ideal for test benches used to analyze thermal processes, as well as for process plants where reliable temperature data is required for control and quality assurance. The galvanic isolation ensures high measurement stability and secure integration into CAN-based systems.<\/p>\n","produktvergleich_rest_api":"<\/p>\n<p><h2>Comparison of UC-CAN-U-THERMO4_K with common market products<\/h2>\n<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Interfaces &#038; Communication<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-U-THERMO4_K<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN thermocouple modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Protocol transparency<\/strong><\/td>\n<td data-label=\"Market Comparison\">For many standard modules, the telegram structure or integration is manufacturer-specific.<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Open CAN protocol for seamless integration into existing CAN architectures.<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Facilitates integration into existing controllers, gateways, and CAN networks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automatic telegram processing<\/strong><\/td>\n<td data-label=\"Market Comparison\">Recurring CAN telegrams often have to be processed using external control logic.<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Auto TX\/RX mode for automatic processing of CAN packets.<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Reduces the implementation effort in the controller and simplifies recurring communication tasks.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>CAN standards and bit rates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Supported CAN parameters are often limited or less clearly specified.<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Supports CAN 2.0A \/ 2.0B and bit rates from 10 kbit\/s to 1 Mbit\/s.<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Offers greater flexibility when integrating into different CAN systems and existing installations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Industrial use<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often used for simple control tasks<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Designed for industrial automation and CAN networks<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Suitable for demanding applications with high requirements for stability and continuous operation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>USB Standard<\/strong><\/td>\n<td data-label=\"Market Comparison\">usually only USB-A \/ B<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Thanks to USB-C, it is significantly more modern and faster than typical USB I\/O boards<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Improves compatibility with current devices and simplifies integration.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Number of USB modules that can be used simultaneously<\/strong><\/td>\n<td data-label=\"Market Comparison\">1\u20134 modules, often without proper management<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Up to 16 modules per system<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Enables larger system configurations without additional distributors or expansion devices.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Galvanic isolation of the CAN interface<\/strong><\/td>\n<td data-label=\"Market Comparison\">A galvanically isolated CAN interface is not standard on all devices.<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Electrically isolated CAN interface rated up to 500 V for reliable communication in industrial environments.<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Improves interference immunity and protects communication in harsh industrial environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Automation &#038; Diagnostics<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-U-THERMO4_K<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN thermocouple modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Diagnostic tools<\/strong><\/td>\n<td data-label=\"Market Comparison\">Mostly not available<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Extensive diagnostic capabilities integrated in the ICT tool<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Simplifies commissioning, troubleshooting, and long-term analysis through centralized, integrated diagnostic functions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Automated control and monitoring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Additional control PC required<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Configurable event control enables automated process monitoring without a control PC<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Reduces the need for external control logic and enables automated processes directly within the module.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Hardware flexibility<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-U-THERMO4_K<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN thermocouple modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Supply voltage<\/strong><\/td>\n<td data-label=\"Market Comparison\">Usually fixed (e.g., +24 V)<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Flexible +12 V DC \u2026 +28 V DC<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Facilitates use in various power supply configurations and reduces the need for additional power supplies.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>EMC stability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules often susceptible to interference<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Industrial\u2011grade EMC design<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Ensures low-interference operation in industrial environments with high electromagnetic interference.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Software &#038; Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-U-THERMO4_K<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN thermocouple modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Limited drivers<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">DELIB library for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Simplifies development through standardized programming interfaces and reduces the effort required for custom driver adaptations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example programs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Barely available or only upon request<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Example programs can be downloaded for free<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Accelerates implementation and facilitates the transition to project-specific applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Ensures long-term functionality and enables improvements without additional licensing costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Example code<\/strong><\/td>\n<td data-label=\"Market Comparison\">Fewer languages or restricted examples<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Extensive examples for C, C++, C#, Python, Java, VB, LabView<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Supports various development environments and facilitates integration into existing software landscapes.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response times<\/strong><\/td>\n<td data-label=\"Market Comparison\">Partially higher latency with standard I\/O<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Very fast firmware<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Improves real-time performance and enables reliable processing of time-critical signals.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>System integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Proprietary systems complicate integration<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Easy integration into PLCs, PCs, and test benches<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Facilitates integration into existing automation and test systems without extensive modifications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Test system integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Competitors often more expensive or less flexible<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Ideal for automotive and test bench applications<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Supports reproducible measurement and test procedures and reduces integration effort in complex test bench environments.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Mechanical &#038; physical properties<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-U-THERMO4_K<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN thermocouple modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the supplier, different or less standard designs may be used.<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Mounting on a 35 x 7.5 mm DIN rail for use in control cabinets and decentralized I\/O systems.<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Enables quick and standards-compliant integration into existing control cabinets.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Reliability<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-U-THERMO4_K<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN thermocouple modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Long-term availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Typically 3\u20135 years<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">10\u2011year guaranteed availability<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Simplifies long-term plant planning and reduces risks associated with early product discontinuations.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Firmware updates<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often paid or limited<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Free for life<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Ensures continuous functional improvement without additional operating costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>ICT tool<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often multiple tools, fewer functions<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">One tool for commissioning, diagnostics, loopback testing, long\u2011term simulation<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Simplifies commissioning, diagnostics, and testing procedures through a centralized software solution.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Production location<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many manufacturers produce in Asia<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Made in Germany<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Enables short supply chains, consistent quality assurance, and a reliable supply of spare parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MTBF<\/strong><\/td>\n<td data-label=\"Market Comparison\">Low-cost OEM modules with shorter lifespan<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">High MTBF values<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Reduces the probability of failure and increases availability in continuous-operation applications.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Failure rate<\/strong><\/td>\n<td data-label=\"Market Comparison\">Higher failure rates with low\u2011cost I\/O<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Very low field failure rates<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Minimizes unplanned downtime and reduces maintenance and service costs.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Spare parts availability<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often early discontinuation<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Long\u2011term spare parts availability<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Facilitates maintenance and modernization of existing systems over many years.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Service and support<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-U-THERMO4_K<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN thermocouple modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Support quality<\/strong><\/td>\n<td data-label=\"Market Comparison\">Call centers or external service providers<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Direct developer support<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Enables fast and technically sound problem-solving without the need to escalate issues through external service providers.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Response time<\/strong><\/td>\n<td data-label=\"Market Comparison\">Sometimes several days<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Very fast response, often same day<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Reduces downtime and speeds up the restoration of system operations when technical issues arise.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Customization<\/strong><\/td>\n<td data-label=\"Market Comparison\">Rare or very expensive<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Custom hardware\/firmware possible<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Enables project-specific solutions without the need for time-consuming in-house development or additional hardware components.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Documentation<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often minimal or incomplete<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Comprehensive and practical documentation<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Simplifies commissioning and reduces the need for follow-up inquiries thanks to clearly structured and comprehensive technical documentation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Consulting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Often only sales support<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Technicians instead of general sales staff<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Ensures application-oriented support directly tailored to technical requirements.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan = \"4\">\n<h3>Economy<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style = \"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style = \"color: #555;\">Advantages of the DEDITEC UC-CAN-U-THERMO4_K<\/th >\n<th style=\"color: #555;\">Practical Benefits of the CAN thermocouple modules<\/th>\n<\/tr >\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Price-performance ratio<\/strong><\/td>\n<td data-label=\"Market Comparison\">Major brands significantly more expensive<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Very good price\u2011performance ratio<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Reduces total cost per channel and enables cost-effective system expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>License costs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Modbus\/features often require additional payment<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">No additional costs for protocols<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Simplifies cost planning and prevents unexpected follow-up costs associated with functional or protocol expansions.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Series prices<\/strong><\/td>\n<td data-label=\"Market Comparison\">Large manufacturers often inflexible<\/td>\n<td data-label=\"UC-CAN-U-THERMO4_K\">Attractive volume pricing<\/td>\n<td data-label=\"Practical Benefits of the CAN thermocouple modules\">Simplifies budget planning for larger volumes and enables cost-effective scaling of projects.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","technische_daten_rest_api":"<h2>Technical Specifications<\/h2>\n<p>The UC-CAN module features four galvanically isolated inputs for Type K thermocouples and enables precise temperature measurement in industrial applications. The integrated cold-junction compensation ensures stable measurement values even under changing environmental conditions. The CAN interface allows the module to be reliably integrated into existing systems, making it ideal for process monitoring, mechanical engineering, and demanding temperature testing tasks.<br \/>\n<\/p>\n<h3>Ethernet interface:<\/h3>\n<ul>\n<li>Ethernet 10\/100 Mbps<\/li>\n<li>Supported protocols: HTTP, UDP, TCP, DHCP, Modbus-TCP<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command line interface, open TCP protocol, Modbus-TCP<\/li>\n<li>Encrypted Ethernet communication possible<\/li>\n<li>Open standard or Modbus TCP protocol<\/li>\n<li>Web interface and app (smartphone and tablet)<\/li>\n<li>Electrically isolated up to 1.5 kV<\/li>\n<\/ul>\n<h3>Wi-Fi interface:<\/h3>\n<ul>\n<li>Wi-Fi connection available<\/li>\n<li>WPS feature<\/li>\n<\/ul>\n<h3>USB interface:<\/h3>\n<ul>\n<li>USB 2.0 interface up to 480 Mbit\/s<\/li>\n<li>Quick setup thanks to plug-and-play integration<\/li>\n<li>Control: API for Windows and Linux (DELIB driver library), command-line interface<\/li>\n<\/ul>\n<h3>CAN interface:<\/h3>\n<ul>\n<li>CAN interface according to ISO 11898<\/li>\n<li>Open CAN protocol<\/li>\n<li>RAW CAN\/J1939<\/li>\n<li>Automatic transmit\/receive mode<\/li>\n<li>Electrically isolated up to 500 V<\/li>\n<\/ul>\n<h3>Temperature inputs:<\/h3>\n<ul>\n<li>Type K thermocouple<\/li>\n<li>Resolution per channel: 14-bit<\/li>\n<li>Accuracy: 0.25 \u00b0C<\/li>\n<li>Temperature range: -200 \u00b0C to +1350 \u00b0C<\/li>\n<li>Accuracy: 0.25 \u00b0C<\/li>\n<li>Accuracy from \u2013200 \u00b0C to 700 \u00b0C: \u00b12 \u00b0C<\/li>\n<li>Accuracy from 700 \u00b0C to 1350 \u00b0C: \u00b14 \u00b0C<\/li>\n<li>Safety: Cold junction compensation<\/li>\n<li>Electrical isolation: Channels 1+2 to channels 3+4: max. 500 V<\/li>\n<li>Electrical isolation: Channels 1\u20134 to the power supply: max. 500 V<\/li>\n<\/ul>\n<h3>Additional features:<\/h3>\n<ul>\n<li>Configurable event control<\/li>\n<li>M2M functionality<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment:<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V to +24 V DC<\/li>\n<li>Plug-in terminal strips with a locking mechanism<\/li>\n<li>Mounting on 35 mm x 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature range available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control panel construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n","produktvergleich":"","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","faq_rest_api":"<div class=\"et_pb_row\">\r\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">CAN THE UC-CAN-U-THERMO4_K RESPOND TO SPECIFIC CAN MESSAGES?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Yes. Using Auto RX mode, received CAN messages can be evaluated and used directly to control functions or outputs. The required receive IDs are defined in the configuration beforehand.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">HOW CAN THE MODULES BE CONFIGURED, TESTED, AND UPDATED?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Configuration, diagnostics, and commissioning are conveniently performed using the DEDITEC ICT-Tool. It also allows functions to be tested and firmware updates to be carried out.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">ARE THERE READY-MADE PROGRAMMING EXAMPLES FOR CONTROLLING IN VB?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>Yes. In the download section, we provide a sample package that contains ready-made VB code for controlling our modules.\r\nIn addition, the package includes implementation examples for other supported programming languages.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT THE AVAILABLE INTERFACES AND FUNCTIONS?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>A complete description of the supported interfaces, communication options, and device functions can be found in the module manual. It is available at any time via the \"Downloads and Manuals\" tab on the respective product page as well as in the download section of the DEDITEC homepage.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\r\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT INTEGRATING THE API INTO MY OWN SOFTWARE PROJECTS?<\/h5>\r\n<div class=\"et_pb_toggle_content clearfix\">\r\n<p>All information required to integrate the module into your own applications, including API descriptions and function references, can be found in the module manual as well as on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\r\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25567960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25567960"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25584033"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25567960"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25567960"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25567960"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25567960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}