{"id":25567842,"date":"2022-05-18T15:58:16","date_gmt":"2022-05-18T13:58:16","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/shop\/uncategorized\/bs-weu-modul-mit-16-32-64-96-128-digitalen-ausgaengen\/"},"modified":"2026-09-14T10:14:57","modified_gmt":"2026-09-14T08:14:57","slug":"tcp-switching-outputs-do","status":"publish","type":"product","link":"https:\/\/www.deditec.de\/en\/shop\/bs\/ethernet-wifi\/tcp-switching-outputs-do\/","title":{"rendered":"TCP switch outputs * Ethernet module with 16\/32\/64\/96\/128 digital outputs (Modbus TCP-compatible)"},"content":{"rendered":"<section class=\"ddt-product-description\">\n<h2>Product Description<\/h2>\n<p>The BSW-DO-8-128 Modbus TCP switching outputs from DEDITEC\u2019s BS-WEU series are industrial Ethernet output modules designed to control digital loads, actuators, and signal transmitters in network and automation environments. Depending on the model, 16, 32, 64, 96, or 128 digital output channels are available. The outputs can be configured as 1 A relay outputs, 3 A relay outputs, or 3 A MOSFET outputs. Connectivity is provided via Ethernet, Modbus TCP, Wi-Fi\/WLAN, or USB.<\/p>\n<h3>System Role in Ethernet and Modbus TCP Architectures<\/h3>\n<p>As network-enabled output modules, the Modbus TCP switching outputs handle the decentralized switching function between the control level and the field level. As a result, digital devices do not have to be wired exclusively to a central controller; instead, they can be integrated into distributed automation structures via Ethernet and Modbus TCP. This supports applications in machine control, plant automation, test benches, building automation, and control panel technology.<\/p>\n<p>The modules are suitable for PLC systems, PC-based controllers, control systems, HMI\/visualization systems, and custom-developed automation software. Digital outputs can be set, monitored, and integrated into existing control processes via the network interface.<\/p>\n<h3>Digital switching outputs for various load and channel sizes<\/h3>\n<p>The product cluster covers a variety of switching requirements. Variants with 16 or 32 outputs are suitable for more compact switching tasks, while those with 64, 96, or 128 outputs are designed for larger I\/O structures with many digital switching points. This allows you to select the number of channels appropriate for your application without changing the underlying system architecture.<\/p>\n<p>Relay outputs are designed for standard switching tasks with electrically isolated contacts. MOSFET outputs enable electronic switching in the DC voltage range and are particularly suitable for applications requiring contactless switching. This allows the module to be selected based on the load, load type, and desired switching behavior.<\/p>\n<h3>Reliable Signal Processing and Diagnostics<\/h3>\n<p>For industrial applications, controlled output behavior is crucial. The modules support timeout protection and fail-safe functions so that defined output states can be implemented in the event of communication problems. Status LEDs for each output facilitate direct monitoring at the device and support commissioning, diagnostics, and service in the control cabinet or on the machine.<\/p>\n<p>The rugged design, DIN rail mounting, and plug-in terminals facilitate clear wiring and easy integration into industrial installations.<\/p>\n<h3>Fail-Safe Mode for Defined Initial States<\/h3>\n<p>Fail-safe mode is designed to switch to a predefined state in the event of a communication failure or loss of communication. This prevents connected loads, actuators, or signaling devices from remaining in their last switching state in an uncontrolled manner. This function is particularly relevant for applications in which digital outputs are integrated into machine, building, or test bench processes and a defined response to faults is required.<\/p>\n<h3>Typical Applications<\/h3>\n<ul>\n<li>Decentralized switching tasks via Modbus TCP in industrial Ethernet networks<\/li>\n<li>Control of relays, actuators, indicator lights, valves, and signal transmitters<\/li>\n<li>Digital outputs for machine and plant control systems<\/li>\n<li>Switching modules for test benches, laboratory setups, and test systems<\/li>\n<li>Building automation, lighting control, ventilation, and access control<\/li>\n<li>Control panel construction with numerous digital switching points<\/li>\n<li>PC-based automation and remote I\/O applications<\/li>\n<\/ul>\n<h3>Integration, Configuration, and Operation<\/h3>\n<p>Integration is performed via Ethernet using Modbus TCP, as well as other supported network protocols such as TCP, UDP, HTTP, and DHCP. A web interface and an app are available for setup, configuration, testing, and operation. Additionally, the modules can be integrated into custom software and control environments via APIs for Windows and Linux, the DELIB driver library, a command-line interface, and an open TCP protocol.<\/p>\n<p>USB 2.0 supports local commissioning and parameterization. WiFi\/WLAN enables wireless access in suitable network environments. This allows the Modbus TCP switching outputs to be used in both stationary control cabinet installations and flexible test, service, and automation setups.<\/p>\n<h3>Made in Germany<\/h3>\n<p>DEDITEC develops, manufactures, and distributes control, measurement, and regulation technology in Germany. For Modbus TCP switching outputs, \u201cMade in Germany\u201d means product-oriented development, traceable technical documentation, and a design tailored for industrial applications. The combination of a scalable number of channels, network-enabled Modbus TCP communication, a robust aluminum housing, and DIN rail mounting supports use in mechanical engineering, plant automation, test benches, control panel construction, and building automation.<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<section class=\"ddt-technical-data\">\n<h2>Technical Specifications<\/h2>\n<p>The BSW-DO-8-128 Modbus TCP switching outputs from DEDITEC\u2019s BS-WEU series are digital output modules for industrial Ethernet, WiFi\/WLAN, and USB applications. Depending on the model, they provide 16, 32, 64, 96, or 128 digital outputs and are designed for decentralized switching tasks in mechanical engineering, control panel construction, test benches, building automation, and industrial network control systems.<\/p>\n<p>&nbsp;<\/p>\n<h3>At a Glance<\/h3>\n<ul>\n<li>Modbus TCP switching outputs for industrial Ethernet and network controllers<\/li>\n<li>DEDITEC BS-WEU Series digital output modules<\/li>\n<li>Models with 16, 32, 64, 96, or 128 digital outputs<\/li>\n<li>Relay and MOSFET outputs for various switching tasks<\/li>\n<li>Relay outputs up to 1 A and relay outputs up to 3 A<\/li>\n<li>MOSFET outputs up to 3 A for electronic DC switching tasks<\/li>\n<li>10\/100 Mbit Ethernet with Modbus TCP<\/li>\n<li>Wi-Fi\/WLAN connectivity and USB interface for configuration, service, and operation<\/li>\n<li>Web interface, app, ICT tool, DELIB driver library, API, and command-line interface<\/li>\n<li>M2M function and event control for module-internal automation functions<\/li>\n<li>Fail-safe and timeout protection functions for defined output states<\/li>\n<li>LED indicator per I\/O channel and additional status indicators<\/li>\n<li>Supply voltage: +7 V DC to +24 V DC<\/li>\n<li>Mounting on 35 \u00d7 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature ranges available upon request)<\/li>\n<\/ul>\n<h3>Digital Outputs and Switching Tasks<\/h3>\n<ul>\n<li>Digital outputs for switching relays, actuators, signal transmitters, indicator lights, valves, and other digital loads<\/li>\n<li>Scalable channel counts with 16, 32, 64, 96, or 128 digital outputs<\/li>\n<li>Suitable for compact control tasks and larger decentralized I\/O structures<\/li>\n<li>Relay outputs for classic switching tasks with mechanical contacts<\/li>\n<li>Relay variants up to 1 A and 3 A for different switching capacities<\/li>\n<li>MOSFET outputs up to 3 A for electronic DC switching operations<\/li>\n<li>Selection based on load type, switching capacity, number of channels, and desired switching behavior<\/li>\n<\/ul>\n<h3>Interfaces and Integration<\/h3>\n<ul>\n<li>Centralized communication via Ethernet using Modbus TCP<\/li>\n<li>Integration into PLC, PC, HMI, visualization, and control system environments<\/li>\n<li>WiFi\/WLAN for wireless access in suitable network environments<\/li>\n<li>USB for local commissioning, configuration, and service purposes<\/li>\n<li>Web interface and app for operation and access<\/li>\n<li>ICT tool for configuration, parameterization, and diagnostics<\/li>\n<li>DELIB driver library, API, and command-line interface for software integration<\/li>\n<li>Open TCP protocol for project-specific control and automation applications<\/li>\n<li>Complete interface and detailed data are listed in the product tabs<\/li>\n<\/ul>\n<h3>Operational Safety, Diagnostics, and Automation Functions<\/h3>\n<ul>\n<li>Fail-safe function for defined output states in the event of communication problems<br \/>\nTimeout protection function for a controlled response to communication interruptions<br \/>\nIn the event of a timeout, digital outputs can be activated, deactivated, or left unchanged, depending on the configuration<br \/>\nStatus LEDs for each I\/O channel for quick monitoring directly on the module<br \/>\nAdditional system indicators for communication, error conditions, I\/O access, and output shutdown<br \/>\nM2M function for automated data exchange between DEDITEC modules<br \/>\nEvent Control for simple if-then logic directly within the module<br \/>\nSupport for commissioning, diagnostics, maintenance, and troubleshooting in the control cabinet or at the machine<\/li>\n<\/ul>\n<h3>Mechanics and Operating Environment<\/h3>\n<ul>\n<li>Designed for industrial applications in control cabinets and decentralized automation systems<\/li>\n<li>Supply voltage: +7 V DC to +24 V DC<\/li>\n<li>Mounting on 35 \u00d7 7.5 mm top-hat rail<\/li>\n<li>Operating temperature: +10 \u00b0C to +50 \u00b0C (extended temperature ranges available upon request)<\/li>\n<li>Suitable for typical industrial indoor and control cabinet environments<\/li>\n<li>Applications: Mechanical engineering, plant automation, test benches, control cabinet construction, building automation, and industrial network control systems<\/li>\n<\/ul>\n<\/section>\n","protected":false},"featured_media":25586456,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[232,1589],"product_tag":[],"class_list":{"0":"post-25567842","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"einausgang-digitale-ausgaenge","7":"einausgang-do16","8":"einausgang-do32","9":"einausgang-do64","10":"einausgang-do96","11":"einausgang-do128","12":"einausgang-_digital","13":"schnittstelle-seriell","14":"schnittstelle-wifi","15":"schnittstelle-can","16":"schnittstelle-usb","17":"schnittstelle-ethernet","18":"product_cat-ethernet-wifi","19":"product_cat-bs","20":"pa_anzahl-kanaele-do-96_do_ch_de","21":"pa_anzahl-kanaele-do-64_do_ch_de","22":"pa_anzahl-kanaele-do-32_do_ch_de","23":"pa_anzahl-kanaele-do-16_do_ch_de","24":"pa_anzahl-kanaele-do-128_do_ch_de","25":"pa_ausgaenge-do-art-relais-ausgaenge-3a_de","26":"pa_ausgaenge-do-art-relais-ausgaenge-1a_de","27":"pa_ausgaenge-do-art-mosfet-ausgaenge-2a_de","29":"first","30":"instock","31":"taxable","32":"shipping-taxable","33":"purchasable","34":"product-type-variable"},"acf":{"sge_text":"<p>The BSW-DO-8-128 product cluster comprises Modbus TCP switching outputs from the DEDITEC BS-WEU series for industrial Ethernet and network control systems. The digital output modules control relay or MOSFET outputs with 16, 32, 64, 96, or 128 channels via Ethernet, Wi-Fi\/WLAN, or USB. Depending on the variant, relay outputs rated at 1 A or 3 A and MOSFET outputs rated at 3 A are available. Typical applications include machine and plant control, test benches, control panel construction, and building and access control systems.<\/p>\n","question_1":"","answer_1":"","question_2":"","answer_2":"","question_3":"","answer_3":"","question_4":"","answer_4":"","question_5":"","answer_5":"","question_6":"","answer_6":"","question_7":"","answer_7":"","question_8":"","answer_8":"","question_9":"","answer_9":"","question_10":"","answer_10":"","produktvergleich_rest_api":"","zusatztext_rest_api":"","technische_daten_rest_api":"","produktvergleich":"<h2>Comparison: Modbus TCP Switching Outputs for Industrial Ethernet and Network Controllers<\/h2>\n<p>The following comparison provides a technical overview of the BSW-DO-8-128 Modbus TCP switching outputs: these are digital output modules from the DEDITEC BS-WEU series featuring Ethernet, WiFi\/WLAN, USB, Modbus TCP, scalable channel counts ranging from 16 to 128 outputs, and relay and MOSFET output options. The table is designed to facilitate a quick assessment for purchasing, development, control panel construction, test bench construction, and industrial automation.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"g6g-respo-table\">\n<table>\n<tbody>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Product Type, Modbus TCP and System Integration<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style=\"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style=\"color: #555;\">BSW-DO-8-128<\/th>\n<th style=\"color: #555;\">Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Product Type<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many Web-I\/O or Ethernet-I\/O modules are designed as compact single modules, relay cards or universal mixed I\/O solutions.<\/td>\n<td data-label=\"BSW-DO-8-128\">Modbus TCP switching outputs as digital output modules of the DEDITEC BS-WEU series.<\/td>\n<td data-label=\"Practical Benefit\">Suitable when digital loads, relays, actuators or signal devices need to be switched specifically via Ethernet and Modbus TCP.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Signal Direction<\/strong><\/td>\n<td data-label=\"Market Comparison\">Combined I\/O modules often focus on general signal diversity.<\/td>\n<td data-label=\"BSW-DO-8-128\">Focus on digital switching outputs for industrial output signals.<\/td>\n<td data-label=\"Practical Benefit\">Supports clear switching tasks in machines, systems, test benches, control cabinets and building automation.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Modbus TCP<\/strong><\/td>\n<td data-label=\"Market Comparison\">Not every Ethernet switching module is consistently designed for Modbus TCP integration in automation environments.<\/td>\n<td data-label=\"BSW-DO-8-128\">Modbus TCP via Ethernet\/LAN.<\/td>\n<td data-label=\"Practical Benefit\">Simplifies integration into PLC, PC, HMI, visualization and control system environments.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Communication Paths<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many solutions focus on a primary interface such as Ethernet or USB.<\/td>\n<td data-label=\"BSW-DO-8-128\">Ethernet 10\/100 Mbit, WiFi\/WLAN and USB; additional interfaces are documented in the product tabs.<\/td>\n<td data-label=\"Practical Benefit\">Supports network operation, wireless access as well as local commissioning, parameterization and service.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Software Integration<\/strong><\/td>\n<td data-label=\"Market Comparison\">Software integration varies by manufacturer and is sometimes limited to individual tools or protocols.<\/td>\n<td data-label=\"BSW-DO-8-128\">Web interface, app, ICT tool, DELIB driver library, API, command line interface and open TCP protocol.<\/td>\n<td data-label=\"Practical Benefit\">Simplifies integration into custom test bench, control and automation software.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Digital Outputs, Channel Counts and Output Types<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style=\"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style=\"color: #555;\">BSW-DO-8-128<\/th>\n<th style=\"color: #555;\">Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Channel Count<\/strong><\/td>\n<td data-label=\"Market Comparison\">Compact Ethernet or Web-I\/O modules often offer fewer digital outputs or require multiple devices for larger switching tasks.<\/td>\n<td data-label=\"BSW-DO-8-128\">Variants with 16, 32, 64, 96 or 128 digital outputs.<\/td>\n<td data-label=\"Practical Benefit\">Many digital switching points can be consolidated into a network control system using a scalable output module.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Output Types<\/strong><\/td>\n<td data-label=\"Market Comparison\">Some switching modules are limited to relay outputs or electronic outputs.<\/td>\n<td data-label=\"BSW-DO-8-128\">Relay outputs and MOSFET outputs depending on the variant.<\/td>\n<td data-label=\"Practical Benefit\">The output module can be selected according to load type, switching frequency and desired output technology.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Relay Outputs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Relay outputs differ depending on the module in switching voltage, switching current and contact design.<\/td>\n<td data-label=\"BSW-DO-8-128\">Relay outputs up to 1 A and relay outputs up to 3 A.<\/td>\n<td data-label=\"Practical Benefit\">Suitable for classic switching tasks with mechanical contacts, e.g. auxiliary relays, signal devices or load groups.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>MOSFET Outputs<\/strong><\/td>\n<td data-label=\"Market Comparison\">Electronic DC outputs are not available on all Ethernet switching modules or are only implemented in separate variants.<\/td>\n<td data-label=\"BSW-DO-8-128\">MOSFET outputs up to 3 A.<\/td>\n<td data-label=\"Practical Benefit\">Supports contactless DC switching, especially for applications with electronic loads or higher switching frequency.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Scalability<\/strong><\/td>\n<td data-label=\"Market Comparison\">For many solutions, channel count must be increased using additional modules, extensions or separate devices.<\/td>\n<td data-label=\"BSW-DO-8-128\">Product cluster with graded channel counts from 16 to 128 digital outputs.<\/td>\n<td data-label=\"Practical Benefit\">Simplifies selection according to application, from compact control cabinet setups to larger decentralized I\/O structures.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Operational Safety, Diagnostics and Automation<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style=\"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style=\"color: #555;\">BSW-DO-8-128<\/th>\n<th style=\"color: #555;\">Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Fail-Safe and Timeout<\/strong><\/td>\n<td data-label=\"Market Comparison\">Defined output states during communication problems are not implemented equally across all switching modules.<\/td>\n<td data-label=\"BSW-DO-8-128\">Fail-safe and timeout protection functions for digital outputs.<\/td>\n<td data-label=\"Practical Benefit\">Supports controllable output states in case of connection loss or communication issues.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Status Diagnostics<\/strong><\/td>\n<td data-label=\"Market Comparison\">Diagnostic capabilities vary by module and range from simple status indicators to software-supported evaluation.<\/td>\n<td data-label=\"BSW-DO-8-128\">LED indicator per I\/O channel plus additional system indicators.<\/td>\n<td data-label=\"Practical Benefit\">Simplifies commissioning, maintenance and troubleshooting directly on the module, in the control cabinet or at the machine.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Event Control<\/strong><\/td>\n<td data-label=\"Market Comparison\">Simple switching modules often implement event logic entirely in the higher-level controller or software.<\/td>\n<td data-label=\"BSW-DO-8-128\">Event control for storing simple if-then logic inside the module.<\/td>\n<td data-label=\"Practical Benefit\">Reduces effort for simple local control tasks and supports automated processes without an additional control PC.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>M2M Function<\/strong><\/td>\n<td data-label=\"Market Comparison\">Direct module-to-module communication is not provided in many standard switching modules or must be programmed externally.<\/td>\n<td data-label=\"BSW-DO-8-128\">M2M function for automated data exchange between DEDITEC modules after configuration.<\/td>\n<td data-label=\"Practical Benefit\">Supports distributed automation structures where modules need to communicate directly.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Remote Access<\/strong><\/td>\n<td data-label=\"Market Comparison\">Remote access, web operation and diagnostics vary significantly between devices.<\/td>\n<td data-label=\"BSW-DO-8-128\">Access via network, web interface and app.<\/td>\n<td data-label=\"Practical Benefit\">Enables operation, monitoring and service in network environments without checking every switching task locally on the device.<\/td>\n<\/tr>\n<tr class=\"table-headline-row\">\n<td colspan=\"4\">\n<h3>Industrial Use, Mounting and Commissioning<\/h3>\n<\/td>\n<\/tr>\n<tr class=\"table-repeat-head\">\n<th style=\"color: #555;\">Feature<\/th>\n<th style=\"color: #555;\">Market Comparison<\/th>\n<th style=\"color: #555;\">BSW-DO-8-128<\/th>\n<th style=\"color: #555;\">Practical Benefit<\/th>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Power Supply<\/strong><\/td>\n<td data-label=\"Market Comparison\">Many industrial I\/O modules are designed for typical low-voltage supplies in control cabinets; the exact range must be checked individually.<\/td>\n<td data-label=\"BSW-DO-8-128\">+7 V DC to +24 V DC.<\/td>\n<td data-label=\"Practical Benefit\">Usable in typical industrial low-voltage environments and project-specific control setups.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Control Cabinet Mounting<\/strong><\/td>\n<td data-label=\"Market Comparison\">Depending on the module design, additional adapters, table housings or special mounts may be required.<\/td>\n<td data-label=\"BSW-DO-8-128\">DIN rail mount 35 \u00d7 7.5 mm.<\/td>\n<td data-label=\"Practical Benefit\">Simplifies integration into control cabinets, test fields, plant engineering and decentralized automation structures.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Wiring<\/strong><\/td>\n<td data-label=\"Market Comparison\">Wiring and maintenance depend heavily on terminal type, locking mechanism and misplug protection.<\/td>\n<td data-label=\"BSW-DO-8-128\">Pluggable WAGO spring terminal strip with locking mechanism and misplug protection.<\/td>\n<td data-label=\"Practical Benefit\">Supports clear wiring, secure installation and service-friendly replacement in the control cabinet.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Operating Temperature<\/strong><\/td>\n<td data-label=\"Market Comparison\">Temperature ranges must be evaluated separately for Ethernet I\/O modules used in control cabinets, test fields or laboratory environments.<\/td>\n<td data-label=\"BSW-DO-8-128\">+10 \u00b0C to +50 \u00b0C.<\/td>\n<td data-label=\"Practical Benefit\">Suitable for typical industrial indoor, control cabinet, test bench and laboratory environments.<\/td>\n<\/tr>\n<tr>\n<td style=\"color: #555;\" data-label=\"Feature\"><strong>Commissioning and Service<\/strong><\/td>\n<td data-label=\"Market Comparison\">Commissioning depends on the module and may be done via web interface, manufacturer tool, local interface or custom software.<\/td>\n<td data-label=\"BSW-DO-8-128\">Configuration and access via ICT tool, web interface, app, USB, Ethernet and WiFi\/WLAN.<\/td>\n<td data-label=\"Practical Benefit\">Supports flexible setup, local service and network-based maintenance in industrial applications.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","zusatztext":"<section class=\"ddt-use-cases\">\n<h2>Typical Application Areas of the Modbus TCP Switching Outputs<\/h2>\n<p>The Modbus TCP switching outputs BSW-DO-8-128 are suitable for industrial applications in which digital loads, relays, actuators or signal devices need to be switched via Ethernet, WiFi\/WLAN, USB and Modbus TCP. With variants featuring 16, 32, 64, 96 or 128 digital outputs as well as relay and MOSFET outputs with 1 A and 3 A, the product cluster is particularly suitable for decentralized switching tasks in machines, control cabinets, test benches, building automation and distributed remote I\/O structures.<\/p>\n<p>&nbsp;<\/p>\n<h3>Suitable for<\/h3>\n<ul>\n<li>Machine and plant engineering<\/li>\n<li>Control cabinet construction and industrial control technology<\/li>\n<li>PLC-related automation environments with Modbus TCP<\/li>\n<li>Decentralized remote I\/O and Ethernet I\/O structures<\/li>\n<li>Test benches, test systems and laboratory setups<\/li>\n<li>Building automation, lighting control and access systems<\/li>\n<li>PC-based control and visualization systems<\/li>\n<li>Industrial network control with Ethernet, WiFi\/WLAN or USB<\/li>\n<li>Special-purpose machines and project-specific automation solutions<\/li>\n<\/ul>\n<h3>Typical Applications<\/h3>\n<ul>\n<li>Switching digital outputs via Modbus TCP in Ethernet networks<\/li>\n<li>Controlling relays, actuators, valves, indicator lights and signal devices<\/li>\n<li>Integrating digital switching outputs into PLC, HMI, visualization and SCADA environments<\/li>\n<li>Decentralized switching control in machines, systems and test equipment<\/li>\n<li>Controlling load groups in control cabinets or distributed I\/O installations<\/li>\n<li>Remote control and diagnostics of digital outputs via network access, web interface or app<\/li>\n<li>Building scalable output systems with 16 to 128 digital switching points<\/li>\n<li>Integration into PC-based test, measurement and automation software via API, DELIB driver library or command line interface<\/li>\n<\/ul>\n<h3>Typical Signal and Switching Tasks<\/h3>\n<ul>\n<li>Switching digital loads via Ethernet and Modbus TCP<\/li>\n<li>Implementing decentralized output signals in distributed automation structures<\/li>\n<li>Switching classic relay outputs for industrial loads<\/li>\n<li>Electronic switching of DC loads via MOSFET outputs up to 3 A<\/li>\n<li>Controlling signal lights, warning devices, valves, interlocks and auxiliary relays<\/li>\n<li>Grouping many digital switching points across 16, 32, 64, 96 or 128 output channels<\/li>\n<li>Defined output states during communication issues via fail-safe and timeout protection functions<\/li>\n<li>Local commissioning, service and parameterization via USB as well as network access via Ethernet or WiFi\/WLAN<\/li>\n<li>Direct module communication and simple event logic via M2M function and event control<\/li>\n<\/ul>\n<\/section>\n","produktbeschreibung_rest_api":"","faq_rest_api":"<div class=\"et_pb_row\">\n<div class=\"et_pb_column et_pb_column_4_4  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW IS THE MODULE CONTROLLED VIA ETHERNET OR WIFI?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>The module can be integrated and controlled via either Ethernet or WiFi in an IP-based network. Both interfaces use the same communication mechanisms, so control is independent of the transmission medium.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW IS ACCESS TO DEVICE FUNCTIONS VIA USB IMPLEMENTED IN PROGRAMMING?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Access is carried out via provided API functions of the respective software library. These enable reading input states as well as setting or retrieving parameters and status information. Communication can be either cyclic or event-driven.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">CAN THE MODULE BE USED WITHOUT AN ADDITIONAL PLC?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Yes, thanks to the integrated event control, control tasks can be executed directly on the module. Using the ICT-Tool, \u201cif-then\u201d actions can be configured, enabling many applications to be implemented without an additional control PC or PLC.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND CURRENT DOCUMENTATION AND TECHNICAL RESOURCES?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>Current manuals, technical documentation, and other product-specific materials can be found directly on the product page under \"Downloads and Manuals\". In addition, these documents are also available for download in the central download section of the DEDITEC homepage.<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">WHERE CAN I FIND INFORMATION ABOUT INTEGRATING THE API INTO MY OWN SOFTWARE PROJECTS?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>All information required to integrate the module into your own applications, including API descriptions and function references, can be found in the module manual as well as on the DEDITEC website in the \"Software\" section under \"Control and Programming\".<\/p>\n<\/div>\n<\/div>\n<div class=\"et_pb_module et_pb_toggle ally-toggle et_pb_toggle_item  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">HOW CAN I DETERMINE IF THE LOAD IS GENERATING TOO HIGH A INRUSH CURRENT?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p>If signal relays are overloaded by an excessively high inrush current, the contacts may stick, causing the output to remain continuously open.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n"},"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product\/25567842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25567842"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25586456"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25567842"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_brand?post=25567842"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_cat?post=25567842"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/product_tag?post=25567842"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}