{"id":25568950,"date":"2010-05-12T16:07:31","date_gmt":"2010-05-12T14:07:31","guid":{"rendered":"https:\/\/deditec.khpmax5.serverpress.de\/?p=25568950"},"modified":"2025-09-18T14:56:32","modified_gmt":"2025-09-18T12:56:32","slug":"pr010","status":"publish","type":"post","link":"https:\/\/www.deditec.de\/en\/news\/pr010\/","title":{"rendered":"USB-LOGI-100 \u2013 USB Logic Analyzer with 100 MHz for PC"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;section&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; custom_padding=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row admin_label=&#8221;row&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; custom_margin=&#8221;0px||||false|false&#8221; custom_padding=&#8221;0px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Text&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; custom_margin=&#8221;0px||||false|false&#8221; custom_padding=&#8221;0px||||false|false&#8221; hover_enabled=&#8221;0&#8243; use_border_color=&#8221;off&#8221; border_color=&#8221;#ffffff&#8221; border_style=&#8221;solid&#8221; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<p><strong>Highlights<\/strong><\/p>\n<ul>\n<li>100 MSamples\/sec (down to 100 Samples\/sec)<\/li>\n<li>18 channels<\/li>\n<li>Adjustable from 100 MHz to 100 Hz<\/li>\n<li>4096 sample depth per channel<\/li>\n<li>1\/8 to 7\/8 pre-trigger range<\/li>\n<li>2 trigger levels<\/li>\n<li>Windows software Logi+<\/li>\n<\/ul>\n<p><strong>USB-LOGI-100 \u2013 USB Logic Analyzer with 100 MHz for PC<\/strong><\/p>\n<p>USB-LOGI-100 Logic Analyzer<br \/>High-quality entry-level model including analysis software.<br \/>With the USB-LOGI-100, DEDITEC GmbH (Br\u00fchl, Germany) expands its range of logic analyzers.<\/p>\n<p><strong>100 MHz Logic Analyzer<\/strong><\/p>\n<p>The USB-LOGI-100 supports a sampling rate of up to 100 MHz (adjustable down to 100 Hz).<br \/>A total of 18 channels can be sampled, each with a memory depth of 4096 samples.<\/p>\n<p>A pre-trigger can be configured between 1\/8 and 7\/8 of the memory range, allowing data acquisition to begin even before the defined trigger point.<br data-start=\"245\" data-end=\"248\" \/>For each channel, two trigger levels can be set with conditions such as high, low, rising edge, falling edge, or both edges.<br data-start=\"372\" data-end=\"375\" \/>These two trigger levels can be combined using a separate configuration menu.<\/p>\n<p>The device is housed in a compact and robust enclosure with dimensions of 80 \u00d7 61 \u00d7 22 mm.<br \/>Communication with the PC is handled via USB; no external power supply is required.<\/p>\n<p><strong>Logi+ Software<\/strong><\/p>\n<p>Included with the device is the Logi+ software for Windows. This program allows all 18 channels to be visualized graphically on-screen. Pre-trigger settings and trigger conditions can be freely configured. Measurement results can be saved, loaded, or exported for documentation purposes.<\/p>\n<p><strong>Optional Accessories<\/strong><\/p>\n<p>Optional accessories include a 20-pin measurement cable (for 18 channels + GND) and small test probes known as \u201cMicro Kleps\u201d.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Highlights 100 MSamples\/sec (down to 100 Samples\/sec) 18 channels Adjustable from 100 MHz to 100 Hz 4096 sample depth per channel 1\/8 to 7\/8 pre-trigger range 2 trigger levels Windows software Logi+ USB-LOGI-100 \u2013 USB Logic Analyzer with 100 MHz for PC USB-LOGI-100 Logic AnalyzerHigh-quality entry-level model including analysis software.With the USB-LOGI-100, DEDITEC GmbH (Br\u00fchl, Germany) expands its range of logic analyzers. 100 MHz Logic Analyzer The USB-LOGI-100 supports a sampling rate of up to 100 MHz (adjustable down to 100 Hz).A total of 18 channels can be sampled, each with a memory depth of 4096 samples. A pre-trigger can be configured between 1\/8 and 7\/8 of the memory range, allowing data acquisition to begin even before the defined trigger point.For each channel, two trigger levels can be set with conditions such as high, low, rising edge, falling edge, or both edges.These two trigger levels can be combined using a separate configuration menu. The device is housed in a compact and robust enclosure with dimensions of 80 \u00d7 61 \u00d7 22 mm.Communication with the PC is handled via USB; no external power supply is required. Logi+ Software Included with the device is the Logi+ software for Windows. This program allows [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":25585055,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[303],"tags":[],"class_list":["post-25568950","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/posts\/25568950","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/comments?post=25568950"}],"version-history":[{"count":4,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/posts\/25568950\/revisions"}],"predecessor-version":[{"id":25581601,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/posts\/25568950\/revisions\/25581601"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media\/25585055"}],"wp:attachment":[{"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/media?parent=25568950"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/categories?post=25568950"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.deditec.de\/en\/wp-json\/wp\/v2\/tags?post=25568950"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}