The BS-USB module is equipped with 32 digital outputs. For the digital outputs, you can choose between versions with relay 1A, relay 3A or MOSFET 2A. The module housing consists of a sturdy aluminum profile with top-hat rail mounting.
Optional extensions
- CAN and serial interface (see accessories)
- USB 2.0 interface up to 480 Mbit
- 32 Digital outputs: 1A, 2A or 3A
- Timeout protection function (configurable via software)
- Robust aluminium housing (suitable for top hat rail mounting)
Digital outputs
Relay 1A
With the option “Relay outputs (1A)” reed relays with normally open (NO) function are used. They are suitable for smaller switching capacities of up to 1A and have a service life of well over 100 million switching cycles. The electrical isolation between input and output circuit is up to 1.5kV.
Timeout-protection-function
If communication with the DEDITEC module is interrupted in a timeout case, the timeout protection function takes effect. It can be set for each digital output whether it is to be “switched off”, “switched on” or left unchanged. Motors can thus be switched off in a timeout case, for example, and connected horns or other alarm transmitters can be switched on.
New timeout modes
3 different timeout modes: “normal”, “auto reactive” and “secure outputs” for different procedures in case of a timeout event.
In “secure outputs” timeout mode, access to the outputs is blocked after a timeout event, thus preventing further access to the outputs.
Unlocking must be done by an additional software command.
Relay 3A
With the option “Relay outputs (3A)” power relays with normally open (NO) function are used. They are suitable for switching capacities of up to 3A and have a service life of up to 10 million switching cycles. The electrical isolation between input and output circuit is up to 3kV.
MOSFET 2A
With the option “Mosfet outputs (2A)” P-Ch MOSFETs are used. They are suitable for switching capacities up to 2A DC and are practically wear-free.
LEDs
Each digital input and output has a separate LED that lights up when the signal state is active. Furthermore, the status of the operating voltage, the communication with the interface, error events or the occurrence of a timeout can be displayed.
Connectors
A screwless system from the manufacturer WAGO Kontakttechnik is used as the connector. The 1-wire female connectors are 100% protected against mismating and have an eject and locking mechanism. All conductor types up to 1.5mm² can be connected.
Software and control
Our DELIB driver library, which is included with the product, makes it easy to address the product via our API.
We offer support for the following programming languages:
- C
- C++
- C#
- VB
- VBA
- VB.Net
- Java
- Delphi
- LabVIEW
We offer support for the following operating systems:
- Windows 10 (32bit/64bit)
- Windows 8/8.1 (32bit/64bit)
- Windows 7 (32bit/64bit)
- Windows Vista (32bit/64bit)
- Windows XP (32bit/64bit)
- Windows Server 2003 (32bit/64bit)
- Windows 2000
- Linux
Corresponding programming examples can be found in the “Software” section of the products or are included on the driver CD.
Reviews