USB module with 64 optocoupler inputs
USB-OPTOIN-64
USB module with 64 optocoupler inputs
- USB interface-controlled input module
- 64 optocoupler inputs (5V-24V, 64 counter)
- Counter for change of state of inputs
- Galvanic isolation
This digital module provides 64 Opto-in inputs, which are suitable for industrial applications for registration of status or even to count the changes of state of the inputs.
Our USB modules have been developed for industrial applications for measurement, control and regulation. The modules all feature a USB interface and can therefore be connected to PC systems with USB bus. The USB bus has been used successfully for many years in use and is characterized by its high flexibility.
As terminal block, user-friendly terminal strips with locking protection and ejection mechanism are used. They allow quick replugging . The wire connection itself is realised with a screwless connector system. A tool is included with each module.

More info
USB-Interface
Transfer rate
It supports the standard USB 2.0 and USB 1.1. The transfer rates are 12 Mbit/s or 1.5 MBit/s.
Inputs
Visual monitoring of inputs
The state of every input is directly indicated by a LED. That way, wrong wiring is easily noticeable.
Detecting short input pulses
The module won't miss fast state changes, even if the inputs are sampled in larger periods. Fast state changes between two readout-cycles are detected through an additional logic and can be readout by software. A LED (combined for all inputs) indicates a "state change". The LED does not extinguish until the software register for input state changes is read out.
Counter
Every input channel has a 16 bit counter. Herewith the module "counts" additional events.
Input protection using optocoupler
The inputs have AC-suitable optocouplers. Therefore you don't need to pay attention to the polarity while wiring the inputs.
Input voltage
By default the inputs are designed for a voltage of 24V. They can be adjusted (even later) to 15V, 12V or 5V.
Relay Outputs
Relay-outputs (galvanically isolated, permanent load of 1A AC)
Relays ensure a save galvanic isolation of the outputs. They are designed for up to 36V/1A. Maximum switchable power is 20W.
Timeout-protection
If required, a timeout-protection may be enabled, switching automatically off the outputs to prevent damage. This takes place, when e.g. the communication gets lost. Switching off the outputs is indicated by a LED.
Connector
Easy to maintain connector system
The plug and socket consist of a multipoint socket connector and a multipin connector with a throw-off lever. Plug-in and plug-out is easy as well as rewiring the terminal strip. The wire connection itself is realized with a screwless connector system. A tool is included with each module.

Config
Configuration of USB modules
A configuration of a USB product is not needed - this complete the driver with their Plug and Play mechanism.
Working with several modules
Are more than one USB products working on a system, the driver library differentiate between these modules.
Every brand new USB product has the ID "0". The ID can be changed by the DELIB-Configuratin Utility and will be stored in an EEPROM on the module.
So you can use up to eight identical modules on one pc.
Working with several modules on one pc
| DELIB-Configuration Utility für USB Module |
|
Click to enlarge ![]() |

Tech.-Info
USB-Interface |
|
| Power Supply | 7 to 24V DC (by a double-pole pluggable screw clamp) |
| Interface |
USB (galvanically isolated using optocoupler) USB 2.0 / USB 1.1 Jumpers for external power supply or via USB One LED for 5V voltage feed |
| API-library | Easy to implement C library to access the inputs and outputs |
Optocoupler-Input-Module |
|
| Inputs |
64 Opto-In-Inputs Galvanic isolated using optocoupler 24V AC switching voltage (optional as well available for 15V, 12V, or 5V) 16 Bit-counter per input channel Logging of impulses between 2 read out cycles |
| Activity-LED | A LED for each input channel |
| Connectors | 16 pin pluggable terminal block each 8 inputs |

Software
Controlling by the DELIB DLL under Windows
The DELIB DLL allows a standard respond of all DEDITEC measurement modules. For this we provide all functions of our products to the software engineer.
Simple testprogram with example for digital inputs
| Digital Input/Output Sample Testprogramm für Module |
|
Click to enlarge ![]() |
With this tool you can test our products very easily. It is easy to handle and supports all modules of DEDITEC. The example above shows a test of a RO-USB-O32 input module.
Examples for responding our products with "C"
In the following example we show you in "C", how to access to our input modules in short time.
1. Step: Open the module
handle = DapiOpenModule(RO-USB,0); // Open USB-module
2. Step: Reading of 16 digital inputs
data = DapiDIGet16(handle, 0); // Read the first 16 digital inputs
3. Step: Close the module
DapiCloseModule(handle); // Close the module
The function "DapiOpenModule" is used to open a special kind of module.
Which module should be openend, is defined by the two parameters.
The first parameter is for the "module ID". By the integrated "DELIB.H", you can also set this parameter to "RO-USB1".
So the driver library recognize, that an ethernet interface will be driven.
The second parameter assigns the module number. If only one module is connected to the pc, the module number is "0". Are there more than one modules in the network, you have to set the correct number.
Controlling of more than one USB-module
Example for opening several modules on one pc:
Open a module with ID "1"
handle1 = DapiOpenModule(RO-USB1,1); // open USB-module with ID=1
Open a module with ID "4"
handle2 = DapiOpenModule(RO-USB1,4); // open USB-module with ID=4

Overview about available DELIB-Functions
General
General Handling
DapiOpenModule
ULONG DapiOpenModule(ULONG moduleID, ULONG nr);
This function opens a particular module. p>
DapiCloseModule
ULONG DapiCloseModule(ULONG handle);
This command closes an opened module. p>
DapiGetLastError
ULONG DapiGetLastError();
This function returns the last registered error. p>
DapiGetLastErrorText
ULONG DapiGetLastErrorText(unsigned char * msg, unsigned long msg_length);
This function reads the text of the last registered error. p>
DapiGetDELIBVersion
ULONG DapiGetDELIBVersion(ULONG mode, ULONG par);
This function returns the installed DELIB version. p>
Special
Special functions
DapiSpecialCommand - DapiSpecialCMDGetModuleConfig
ULONG DapiSpecialCommand(ULONG handle, DAPI_SPECIAL_CMD_GET_MODULE_CONFIG, par, 0, 0);
This command returns the hardware equipment (number of in-/output channels) of the module. p>
Digital-input
Digital input functions
DapiDIGet1
ULONG DapiDIGet1(ULONG handle, ULONG ch);
This command reads a single digit input. p>
DapiDIGet8
ULONG DapiDIGet8(ULONG handle, ULONG ch);
This command reads 8 digital inputs simultaneously. p>
DapiDIGet16
ULONG DapiDIGet16(ULONG handle, ULONG ch);
This command reads 16 digital inputs simultaneously. p>
DapiDIGet32
ULONG DapiDIGet32(ULONG handle, ULONG ch);
This command reads 32 digital inputs simultaneously. p>
DapiDIGet64
ULONGLONG DapiDIGet64(ULONG handle, ULONG ch);
This command reads 64 digital inputs simultaneously. p>
DapiDIGetFF32
ULONG DapiDIGetFF32(ULONG handle, ULONG ch);
This command reads the flip-flops from the inputs and resets them.
(Input state change). p>
DapiDIGetCounter
ULONG DapiDIGetCounter(ULONG handle, ULONG ch, ULONG mode);
This command reads the counter of a digital input. p>

Connector
Plug connection
Screwless plug connectors
All input and output connectors have a practical, screwless terminal block. An mechanic ejection guarantees a very quick module change without any special tools. Wire connection happens with screwdriver or an included plastic pin. (s. pic.1)
Pic1:
Connection example of a RO-Module
![]() |
RO-MODULE | |
![]() |
Step 1:
| |
![]() |
Step 2:
| |
![]() |
Step 3:
| |
![]() |
Step 4:
|

Optional E.
Hutschiene-1m
Die 1m Hutschiene eignet sich optimal zur schnellen Montage unserer Steuer/Regeltechnik-Module.
12V Hutschienen-Relais
Reichen die Schaltleistungen unserer Module nicht aus ?
Angesteuert werden können diese Relais beispielsweise durch unsere Relais oder MOS-Ausgänge. Als Steuerspannung muss hierbei 12V DC benutzt werden.
230V Hutschienen-Relais
Sie möchten überprüfen ob 230V AC auf ihrer Schaltung anliegen?
Angesteuert werden können diese Relais beispielsweise durch unsere Opto-In-Eingänge. Als Steuerspannung muss hierbei 230V AC/220V DC benutzt werden.
24V Hutschienen-Relais
Reichen die Schaltleistungen unserer Module nicht aus ?
Angesteuert werden können diese Relais beispielsweise durch unsere Relais oder MOS-Ausgänge. Als Steuerspannung muss hierbei 24V DC benutzt werden.
230V Hutschienen-Solid-State-Relais für induktive Lasten
Mit diesem Solid-State-Relais erweitern wir die maximale Schaltpannung unserer Digitalen Ausgabemodule auf 230V AC.
Angesteuert werden können diese Relais beispielsweise durch unsere Relais oder MOS-Ausgänge. Als Steuerspannung kann hierbei 3.5 ... 32V DC benutzt werden. Mit diesem Solid-State-Relais können induktive Lasten geschaltet werden.
230V Hutschienen-Solid-State-Relais für ohmsche Lasten
Mit diesem Solid-State-Relais erweitern wir die maximale Schaltpannung unserer Digitalen Ausgabemodule auf 230V AC.
Angesteuert werden können diese Relais beispielsweise durch unsere Relais oder MOS-Ausgänge. Als Steuerspannung kann hierbei 3.5 ... 32V DC benutzt werden. Mit diesem Solid-State-Relais können ohmsche Lasten geschaltet werden.
8-times relay powermodule (switching capacity 40V/10A), which can be controlled by relays/opto-couplers
The MOD-REL8_10A is an eight-times extension module, which has 8 relays with a switching capacity of 40V/10A AC or 40V/8A DC. This module can be controlled directly by opto-coupler outputs (e.g. SPS) or relay outputs, which can not switch high capacities.
16 poliger Steckverbinder mit Auswerfmechanik
Unsere Steckverbinder bieten einen einfachen und sicheren Anschluss an unsere Module. Durch die integrierte Auswerfermechanik ist das nachträgliche Austauschen der angeschlossenen Module möglich.
Netzteil 24V/2A für Hutschinenmontage
Das Hutschienen-Netzteil bietet Anwendern eine sichere Arbeitsumgebung und ist eine ideale Spannungsversorgung für unsere Steuer/Regeltechnik-Module. Es besitzt einen Wirkungsgrad von bis zu 80% und Internationale Sicherheitszulassungen Dank der Isolationsklasse 2 als auch der Sicherheit die das Hutschienen-Netzteil bietet.

Manuals
Manuals
Driver
Driver / Programs
DELIB USB driver for Linux
DELIB USB driver for Linux
The DELIB USB driver for Linux supports following products:
- RO-USB-Series
- USB-Mini-Sticks
- USB-Watchdog
- Linux Kernel 2.6.x
Manual for DELIB Driver Library for Windows 7, Windows Vista, XP, 2000 and Linux
Manual for DELIB Driver Library for Windows 7, Windows Vista, XP, 2000 and Linux Documentation of all functions
- module open/close functions
- Digital Input read 1 / 8 / 16 / 32 / 64 bit
- Digital Output write 1 / 8 / 16 / 32 / 64 bit
- A/D Read, read_volt, read_mA, set A/D mode
- D/A Write, write_volt, write_mA, set D/A mode
DELIB driver library for Windows 7, Vista, XP and 2000
DELIB driver library for Windows 7, Vista, XP and 2000
Installation file for USB driver
supports the following operating systems: 32 Bit:
- Windows 7
- Windows Server 2008
- Windows Vista
- Windows XP
- Windows Server 2003
- Windows 2000
64 Bit:
- Windows 7 x64
- Windows Server 2008 x64
- Windows Vista x64
- Windows XP x64
- Windows Server 2003 x64