Ethernet - Measurement modules overview
Overview
Enclosed you will find an overview of our modules with Ethernet interface.
Digital input modules

RO-ETH-O16
Ethernet-input module with 16 optical decoupled switching inputsInputs: 16 (5V-24V )
Outputs: -
Beginning with the RO-ETH-O16 having 16 opto-inputs, we start the series of our Ethernet input-modules. Typical applications are status detection or counter applications.
RO-ETH-O32
Ethernet-input module with 32 optical decoupled switching inputsInputs: 32 * Opto-In (5V-24V)
Outputs: -
Beginning with the RO-ETH-O32 having 32 opto-inputs, we start the series of our Ethernet input-modules. Typical applications are status detection or counter applications.
Digital output modules

RO-ETH-R16
Ethernet relay module with 16 relais outputsInputs: -
Outputs: 16 * Relais (1A)
16 relays of which each one is able to switch a current up to 1A (max. 15 Watt). The galvanically isolated Ethernet interface guarantees a safe connection to the pc.
RO-ETH-R32
Ethernet relay module with 32 relais outputsInputs: -
Outputs: 32 * relais (1A)
32 relays of which each one is able to switch a current up to 1A (max. 20 Watt). The galvanically isolated Ethernet interface guarantees a safe connection to the pc.
RO-ETH-R64
Ethernet-relay-board width 64 relay outputs * din-rail moduleInputs: -
Outputs: 64 * relays (1A)
64 relays of which each one is able to switch a current up to 1A (max. 20 Watt).
RO-ETH-M16
Ethernet module with 16 * MOSFET outputsInputs: -
Outputs: 16 * MOSFETs (2A)
The module with 16 MOSFETs is able to switch loads up to 2A. As the switching operation is done electronically, the MOSFETs are more resistant against interfering impulses but they can only switch DC currents.
RO-ETH-M32
Ethernet-output module with 32 * MOSFET outputsInputs: -
Outputs: 32 * MOSFETs (2A)
The module with 32 MOSFETs is able to switch loads up to 2A. As the switching operation is done electronically, the MOSFETs are more resistant against interfering impulses but they can only switch DC currents.
RO-ETH-M64
Ethernet-output module with 64 * MOSFET outputsInputs: -
Outputs: 64 * Opto (2A)
The module with 64 MOSFETs is able to switch loads up to 2A. As the switching operation is done electronically, the MOSFETs are more resistant against interfering impulses but they can only switch DC currents.
Digital in-/output modules

RO-ETH-O16-R16
Ethernet-input/output module with 16 inputs and 16 outputs (relays 1A)Inputs: 16 * Opto-in (5V-24V )
Outputs: 16 * Relay (1A)
With 16 galvanically isolated inputs and 16 relay outputs, this module is a good choice when optical inputs and relay outputs are needed. The galvanically isolated ethernet interface guarranties a safe connection to the PC.
RO-ETH-O32-R32
Ethernet-input/output module with 32 inputs and 32 outputs (Relais 1A)Inputs: 32 * Opto-in (5V-24V)
Outputs: 32 * Relays (1A)
With 32 galvanically isolated optocoupler inputs and 32 galvanic isolated relay outputs, this module is a good choice when optical inputs and relay outputs are needed.
RO-ETH-O64-R64
Ethernet-input/output module with 64 inputs and 64 outputs (relays 1A)Inputs: 64 * Opto-in (5V-24V )
Outputs: 64 * relais (1A)
With 64 galvanically isolated optocoupler inputs and 64 galvanically isolated relay outputs, this module is a good choice when optical inputs and relay outputs are needed.
RO-ETH-O16-M16
Ethernet-in-/output modules with 16 in- and 16 outputs (Optocoupler 2A)Inputs: 16 * Opto-In (5V-24V)
Outputs: 16 * MOSFETs (2A DC)
With 16 galvanic isolated inputs and 16 optocoupler-controlled MOSFET outputs (and thus galvanically isolated), this module is a good choice when inputs and outputs are needed. The galvanically isolated ethernet interface guarantees a safe connection to the PC.
RO-ETH-O32-M32
Ethernet-in-/output modules with 32 in- and 32 outputs (Optocoupler 2A)Inputs: 32 * Opto-In (5V-24V)
Outputs: 32 * MOSFETs (2A DC)
With 32 galvanically isolated inputs and 32 optocoupler-controlled MOSFET outputs (and thus galvanically isolated), this module is a good choice when inputs and outputs are needed. The galvanically isolated ethernet interface guarantees a safe connection to the PC.
RO-ETH-O64-M64
Ethernet-in-/output modules with 64 in- and outputs (Optocoupler 2A)Inputs: 64 * Opto-In (5V-24V)
Outputs: 64 * MOSFETs (2A DC)
With 64 galvanically isolated inputs and 64 optocoupler-controlled MOSFET outputs (and thus galvanically isolated), this module is a good choice when inputs and outputs are needed.
Analog modules (without galvanic isolation) 

RO-ETH-AD16-DA4
Ethernet 16 * A/D-4 * D/A module with 16 A/D channels and 4 * D/A outputsInputs: 16 * A/D channels (16 bit / 4us conversion time) (0..+5V, 0..+10V -5..+5V, -10..+10V (0..20mA optional))
Outputs: 4 * D/A (16 bit, 10 us conversion time) (0..+5V, 0..+10V -5..+5V, -10..+10V)
The module has 16 * A/D channels (16 bit / 4 us conversion time) and 4 * D/A outputs (16 bit / 10 us conversion time) . The voltage (or optional the current) is converted into a digital value and may e.g. be given back as voltage through a D/A converter. The range of the input and output voltage are separately modifiable through programming.
RO-ETH-AD16
Ethernet module with 16 * A/D channelsInputs: 16 * A/D channels (16 bit / 4us conversion time) (0..+5V, 0..+10V -5..+5V or -10..+10V (0..20mA optional))
Outputs: -
The module has 16 * A/D channels (16 bit / 4 us conversion time). The voltage (or optional the current) is converted into a digital value and is read out by software through the ethernet interface. The range of the input voltage is modifiable through programming.
RO-ETH-DA4
Ethernet module with 4 * D/A outputs (16 bit / 10 us conversion time)Inputs: -
Outputs: 4 * D/A (16 bit, 10 us conversion time) (0-5V, 0-10V +5V, +10V)
The module has 4 D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
Analog modules (with galvanic isolation) 

RO-ETH-AD16_ISO
Ethernet module with 16 * A/D channels, inputs are galvanically isolatedInputs: 16 * A/D channels (16 bit / 4 us conversion time, inputs with common galvanic isolation ) (Unipolar: 0..5V or 0..10V, (0..20mA optional) Bipolar: -5V..+5V or -10V..+10V)
Outputs: -
The module has 16 *A/D channels (16 bit / 4 us conversion time) . The voltage (or optional the current) is converted into a digital value and is read out by software through the ethernet interface. The range of the input voltage is modifiable through programming. The inputs have a common galvanic isolation.
RO-ETH-AD32_ISO
Ethernet module with 32 * A/D channels, inputs have common galvanic isolationInputs: 32 * A/D channels (16 bit, 4 us conversion time, inputs with common galvanic isolation) (Unipolar: 0..5V or 0..10V, (0..20mA optional) Bipolar: -5V..+5V or -10V..+10V)
Outputs: -
The module has 32 A/D channels (16 bit / 4 us conversion time) . The voltage (or optional the current) is converted into a digital value and is read out by software through the ethernet interface. The range of the input voltage is modifiable through programming. The inputs have a common galvanic isolation.
RO-ETH-DA2_ISO
Ethernet module with 2 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 2 * D/A (16 bit, 10 us conversion time, each output has an additional galvanic isolation) (Modes U: 0..+5V, 0..+10V -5..+5V, -10..+10V Modes I: 0..20mA, 4..20mA, 0..24mA )
The module has 2 D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming. Each output has an additional galvanic isolation.
RO-ETH-DA4_ISO
Ethernet module with 4 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 4 * D/A (16 bit, 10 us conversion time, each output is galvanically isolated) (Mode U: 0..+5V, 0..+10V -5..+5V, -10..+10V Mode I: 0..20mA, 4..20mA, 0..24mA )
The module has 4 D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming. Each output has an additional galvanic isolation.
RO-ETH-DA8_ISO
Ethernet module with 8 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 8 * D/A (16 bit, 10 us conversion time, each output with galvanic isolation) (Mode U: 0..+5V, 0..+10V -5..+5V, -10..+10V Mode I: 0..20mA, 4..20mA, 0..24mA )
The module has 8 D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming. Each output has an additional galvanic isolation.
Stepper motor modules

RO-ETH-STEPPER2
Ethernet stepping motor control for 2 * stepperInputs: 4 * Switches (2*End/2*Ref) (12-24V)
Outputs: 2 * Stepper motor control
Controller module for two-phase stepper motors. Functionality is given through an extensive driver library. Simple tasks as driving the motor to a certain positon with corresponding slope is very easy.