CANopen module with 4/8 analog outputs

0 customer reviews

ab  436,14

Availability: In Stock SKU: COS-DA4/8_16 Category:

The COS-DA4/8-16 module is available in versions with 4 or 8 analog outputs. It can be operated as a stand-alone device or in a network of several COS modules.
Due to the CANopen profiles according to the CiA® specification CiA 301, CiA 305 and CiA 401, this module is ideally suited for almost all applications in modern automation technology.

  • CANopen profiles according to CiA® specification CiA 301, CiA 305 and CiA 401
  • Galvanic isolation of the CAN bus
  • Node number and baud rate configurable via coding switch or LSS
  • 4 or 8 D/A channels each with 16-bit resolution
  • Galvanic isolation: max. 1kV
  • voltage ranges: 0-5V, 0-10V, +5V, +10V
  • Current ranges: 0-20mA, 4-20mA, 0-24mA
  • LED status indicators

Analogue outputs

With our digital to analog converter modules you are able to control current or voltage controlled actuators such as valves, servomotors or special power supplies. Especially in harsh industrial environments and with very long cable runs, analog signals, especially currents, can be transmitted interference-free.


Configuration

The baud rate (up to 1Mbit/s) and the node number of the module can be configured via coding switches. Alternatively, this configuration can also be carried out conveniently via LSS using a CANopen master in the bus.

The transmission can be optionally event-controlled, cyclic or synchronous. Thus, for example, digital input statuses can be sent to other BUS participants every second and additionally in the event of an input status change.

Dynamic PDO mapping also allows different types of measurement data to be sent in one PDO (e.g. analog and digital states).

Other nodes in the bus can be monitored via the heartbeat protocol. Each node cyclically sends a CAN message (heartbeat). If the message of a node is missing, e.g. due to a connection termination, this error is registered by the module and can switch an alarm, for example.


Easy installation thanks to DIN rail bus

Thanks to the practical COS bus connector, which is clipped into the top-hat rail, individual modules within a network can be very easily added or exchanged. CAN communication and the power supply is passed on to all connected modules via the DIN rail bus.


LEDs

At the front side of our COS modules there is a row of status LEDs. These give you a quick overview of the most important functions of the modules, such as the switching states of the individual I/Os, module status or whether clean communication via the DIN rail bus is possible. This can be very helpful for fast error analysis, especially for field applications.


Connectors

A screwless system from the manufacturer WAGO Kontakttechnik is used as the connector. The 1-wire female connectors are 100% protected against mismating and have an eject and locking mechanism. All conductor types up to 1.5mm² can be connected.


General

Power supply
as stand-alone device
+7V DC to +24V DC via voltage connector
Power supply
as composite device
Internally via the DIN rail bus
Power consumption
LEDs • Green = CANopen RUN / Indicates the current CANopen status of the module (e.g. “preoperational” or “stopped”)
• Red = CANopen ERR / signals an error, such as faulty CAN-BUS wiring
• Yellow = Power/Status / Lit when power supply = ok
• D/A channel active / not active
• Read/write access to D/A channel
• U mode active / not active
Connectors • Typ: Wago Kontakttechnik 713-1108/037-000
• Pluggable 16 pole female connector with locking mechanism
• 100 % malfunction protected
• 1-conductor connection for all types of conductors up to 1.5mm²
DIN Rail-Bus • CANopen bus connector
• Comfortable and fast connection of further DEDITEC COS modules
• CAN-High, CAN-Low
• +24V, GND
DIN rail mounting TS35
Operating temperature +10°C to +50°C
Dimensions 120 mm x 22,5 mm x 111 mm (H x W x D)

CAN-Interface

Interface • CANopen (electrically isolated up to 500V)
• CANopen profiles according to CiA® specification CiA 301, CiA 305 and CiA 401
NODE-ID • Configurable via coding switch or LLS 1 – 7F hex
Baud rates • Configurable via coding switches
• 1 Mbit/s
• 800 Kbit/s
• 500 Kbit/s
• 250 Kbit/s
• 125 Kbit/s
• 100 Kbit/s
• 50 Kbit/s
• 20 Kbit/s
• 10 Kbit/s
• Autobaud
Protocols • CANopen according to CiA® specification CiA 301, CiA 305 and CiA 401
• CAN 2.0A or CAN 2.0B

Analogue outputs

Analogue outputs • 4 or 8 channels with 16-bit resolution each
• Galvanic isolation channel 1..4 to channel 5..8: max. 1000V AC
• Galvanic isolation to power supply: max. 500V AC
• Voltage ranges: 0-5V, 0-10V, +5V, +10V
• Relative Accuracy: Min: -16 LSB / Max: +16 LSB
• Bipolar Zero Error (T = 25°C): ±4 ppm FSR/°C
• Zero-Scale Error (T = 25°C): ±2 ppm FSR/°C
• Full-Scale Error Temperature Drift: ±1 ppm/°C

[vrm360 canvas_name=s1 model_url=/wp-content/uploads/2021/02/COS-DA4_DA8.obj aspect_ratio=2 initial_offset=1.5 autostart=true lightintensity=0.05 amb_lightintensity=1 button_color=#cc0000 border_width=1 border_color=#acacac backgcolor=#f8f8f8]

Additional information

Weight N/A
Number of D/A channels

,

D/A Auflösung

14 Bit, 16 Bit

Configuration

Configuration of CANopen modules

The CANopen interface is configured via three rotary coding switches located on the front of the module.

The upper and middle rotary coding switches determine the Node ID, the lower one the baud rate.


Rotary coding switch

In this example the operating mode is CANopen, the bit rate is 250 kBit/s and the node ID is 0x24.

 

The upper rotary coding switch determines the more significant bits and the middle switch the less significant bits.

The lower rotary coding switch is used to set the baud rate, the following is a list of all settings:


Meaning lower rotary switch

Value Operating mode Description
0 CANopen Bitrate = 1000 kBit/s
1 CANopen Bitrate = 800 kBit/s
2 CANopen Bitrate = 500 kBit/s
3 CANopen Bitrate = 250 kBit/s
4 CANopen Bitrate = 125 kBit/s
5 CANopen Bitrate = 100 kBit/s
6 CANopen Bitrate = 50 kBit/s
7 CANopen Bitrate = 20 kBit/s
8 CANopen Bitrate = 10 kBit/s
9 CANopen Autobaud + LSS
A CANopen Autobaud
B CANopen Bootloader Bitrate = 250 kBit/s
C CANopen Bootloader Bitrate = 1000 kBit/s, Node ID = 0x7e
D CAN 2.0 A/B Use settings from EEPROM
E CAN 2.0 A/B Bitrate = 1000 kBit/s, CAN ID = 0x100
F CANopen Bitrate = 1000 kBit/s, Node ID = 0x7e

How the modules are controlled exactly, you will find in the programming section

Connection example DA

Connection example

Screwless connector system

The customer’s connection wiring of the inputs and outputs is carried out via screwless, pluggable terminal strips. The conductor connection is made by a so-called actuating tool.
A locking and ejection mechanism facilitates the insertion and removal of the complete terminal strip.

 

Handling

Step 1

Remove the operating tool from the scope of delivery.

Step 2

Insert the operating tool firmly into the side opening in the direction of conductor connection.

Step 3

Now insert the stripped conductor into the open terminal contact.

Schritt 4

Pull the operating tool out again.

Step 5

Check the correct connection of the conductor. It should now no longer be possible to pull it out easily.

Manual COS-Series
Hardware and Software Description
Download
  • Description for the COS-Series
  • Hardware description
  • Software description (CANopen)/

 

DEDITEC driver CD

DEDITEC Driver CD with many helpful tools and manuals for commissioning your DEDITEC products.

  • DELIB driver library for Windows
  • Test and configuration software
  • Manuals
  • Data sheets
  • Example programs for C++, C#, VB, VB.Net, Delphi, LabVIEW

16 pol connector

Required to connect your application to the DEDITEC module

  • Type: Wago Kontakttechnik 713-1108/037-000
  • Pluggable female connector with locking mechanism
  • 100 % malfunction protected
  • 1-wire connection for all types of conductors up to 1.5mm²

Tool for wiring connectors

Serves to open and close the clamp contacts on the Wago connectors.
  • Type: Wago Kontakttechnik 734-231

Power supply 24V/2A for DIN rail mounting

The DR-4524 from Mean Well is a 48W rail mount power supply for industrial applications. It offers protection against short circuit, overload, overvoltage and overheating.

  • Input voltage range: 85V… 264V AC / 120V DC … 370V DC
  • Output voltage: 24V DC
  • Output current: 2A
  • Nominal power: 48W

DIN rail connector

The DIN-Rail connector is a single BUS segment which allows the connection to other modules. It is clipped into the DIN-rail and plugged into the side of an existing DIN-Rail connector.

  • DIN-Rail Bus Connectors
  • Connection of a NET or COS module
  • For extension of the NET or COS bus system
  • 1 piece

16 pol connector

Required to connect your application to the DEDITEC module

  • Type: Wago Kontakttechnik 713-1108/037-000
  • Pluggable female connector with locking mechanism
  • 100 % malfunction protected
  • 1-wire connection for all types of conductors up to 1.5mm²

Strain relief plate for 16 or 18 pole Wago connectors

A strain relief plate that can be mounted centrally between the conductor entries facilitates the plugging and unplugging process and allows easy access to the actuation openings even when wired.

  • Type: Wago / 713-127
  • Suitable for 16/18 pole female connectors with conductor connection
  • Mating and unmating aid for Wago connectors
  • Strain relief of the individual wired conductors
  • Easy mounting

Tool for wiring connectors

Serves to open and close the clamp contacts on the Wago connectors.
  • Type: Wago Kontakttechnik 734-231

DIN Rail

Top-hat rail for mounting our control technology modules.

  • Top-hat rail according to DIN EN 50022
  • Type: Phoenix Contact / 1208131
  • Dimensions in mm: 450 x 35 x 7.5 (L x W x D)

Reviews

There are no reviews yet.

Be the first to review “CANopen module with 4/8 analog outputs”

Your email address will not be published. Required fields are marked *