Digital input modules

RO-CAN-O16
CAN input module with 16 optical decoupled switching inputsInputs: 16 (5V - 24V )
Outputs: -
Beginning with the RO-CAN-O16 having 16 opto-inputs, we start the series of our CAN input-modules. Typical applications are status detection or counter applications. The galvanic isolated CAN interface guarrantees a safe connection to other CAN systems.
RO-CAN-O32
CAN input module with 16 optical decoupled switching inputsInputs: 32 (5V-24V )
Outputs: -
With 32 inputs, these modules can be used in larger installations . The galvanic isolated CAN interface guarrantees a safe connection to other CAN systems.
Digital output modules

RO-CAN-R16
CAN-output module with 16 relay outputsInputs: -
Outputs: 16 * Opto (1A)
16 relays with a maximum switching current of 1A (max.15W) are used for the switching operation on this module. The CAN interface is galvanically isolated.
RO-CAN-R32
CAN-output module with 32 relay outputsInputs: -
Outputs: 32 * Opto (1A)
32 relays with a maximum switch current of 1A (max.15W) are used for the switching operation on this module. The technical data are indentical to the RO-CAN-R16 module.
RO-CAN-R64
CAN-output module with 64 relay outputsInputs: -
Outputs: 64 * relays (1A)
The technical data are indentical to the RO-CAN-R16 module.
RO-CAN-M16
CAN-output module with 16 optocoupler outputsInputs: -
Outputs: 16 * Opto (2A)
These modules are able to switch currents up to 2A by transistors. Electronic switches are more resistant against interfering impulses, but they can only switch DC voltages.
RO-CAN-M32
CAN-output module with 32 optocoupler outputsInputs: -
Outputs: 32 * Opto (2A)
32 transistor outputs with 2A load current features this unit. The technical data are indentical to the RO-CAN-M16 module.
Digital in- and output modules

RO-CAN-O16-R16
CAN-in-/output modules with 16 in- and 16 outputs (relay 1A)Inputs: 16 (5V-24V)
Outputs: 16 * relays (1A)
With 16 galvanically isolated inputs and 16 relay outputs, this module is a good choice when inputs and outputs are needed. The galvanic isolated CAN interface guarranties a safe connection to a CAN system.
RO-CAN-O32-R32
CAN-in-/output modules with 32 in- and 32 outputs (relay 1A)Inputs: 32 (5V-24V)
Outputs: 32 * relays (1A)
The technical data are indentical to the RO-CAN-O16-R16 module.
RO-CAN-O64-R64
CAN-in-/output modules with 64 in- and 64 outputs (relay 1A)Inputs: 64 (5V-24V)
Outputs: 64 * relays (1A)
The technical data are indentical to the RO-CAN-O16-R16 module.
RO-CAN-O16-M16
CAN-in-/output modules with 16 in- and 16 outputs (optocoupler 2A)Inputs: 16 (5V-24V)
Outputs: 16*Opto (2A)
With 16 galvanically isolated inputs and 16 optical isolated outputs, this module is a good choice when inputs and outputs are needed. The galvanically isolated CAN interface guarranties a safe connection to other CAN systems.
RO-CAN-O32-M32
CAN-in-/output modules with 32 in- and 32 outputs (optocoupler 2A)Inputs: 32 (5V-24V)
Outputs: 32 * Opto (2A)
The technical data are indentical to the RO-CAN-O16-M16 module.
Analog modules (without galvanic isolation)

RO-CAN-AD16-DA4
CAN 16 * A/D-4 * D/A module with 16 * A/D input channels and 4 * D/A outputsInputs: 16 * A/D channels (16 bit / 4us conversion time) (0..+5V, 0..+10V -5..+5V, -10..+10V (0..20mA optional))
Outputs: 4 * D/A (16 bit, 10 us conversion time) (0..+5V, 0..+10V -5..+5V, -10..+10V)
The module has 16 A/D channels (16 bit / 4 us conversion time) and 4 D/A outputs (16 bit / 10 us conversion time) . The voltage (or optional the current) is converted into a digital value and may e.g. be given back as voltage through a D/A converter. The range of the input and output voltage are separately modifiable through programming.
RO-CAN-AD16
CAN module with 16 * A/D channels (16 bit / 10 us conversion time)Inputs: 16 * A/D channels (16 bit / 4us conversion time) (0..+5V, 0..+10V -5..+5V or -10..+10V (0..20mA optional))
Outputs: -
The module has 16 * A/D channels (16 bit / 4 us conversion time). The voltage (or optional the current) is converted into a digital value and is read out by software through the ethernet interface. The range of the input voltage is modifiable through programming.
RO-CAN-DA4
CAN module with 4 * D/A outputs (16 bit / 10 us conversion time)Inputs: -
Outputs: 4 * D/A (16 bit) (0-5V, 0-10V +5V, +10V)
The module has 4 D/A outputs (16 bit / 10 us conversion time). Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
Analog modules (with galvanic isolation)

RO-CAN-AD16_ISO
CAN module with 16 * A/D channels, inputs are galvanically isolatedInputs: 16 * A/D channels (16 bit / 4 us conversion time, inputs with common galvanic isolation ) (Unipolar: 0..5V or 0..10V, (0..20mA optional) Bipolar: -5V..+5V or -10V..+10V)
Outputs: -
The module has 16 A/D input-channels (16 bit / 4 us conversion time) . The voltage (or optional the current) is converted into a digital value and is read out by software through the CAN-interface. The range of the input voltage is modifiable through programming. The inputs have a common galvanic isolation.
RO-CAN-AD32_ISO
CAN module with 32 * A/D channels, inputs have common galvanic isolationInputs: 32 * A/D channels (16 bit / 4 us conversion time, inputs with common galvanic isolation ) (Unipolar: 0..5V or 0..10V, (0..20mA optional) Bipolar: -5V..+5V or -10V..+10V)
Outputs: -
The module has 32 * A/D input-channels (16 bit / 4 us conversion time) . The voltage (or optional the current) is converted into a digital value and is read out by software through the USB-interface. The range of the input voltage is modifiable through programming. The inputs have a common galvanic isolation.
RO-CAN-DA2_ISO
CAN module with 2 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 2*D/A (16 bit) (galvanically isolated) (Modes U: 0-5V, 0-10V +5V, +10V Modes I: 0-20mA, 4-20mA 0-24mA)
The module has 2 * D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
RO-CAN-DA4_ISO
CAN module with 4 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 4 * D/A (16 bit, galvanically isolated) (Modes U: 0-5V, 0-10V +5V, +10V Modes I: 0-20mA, 4-20mA 0-24mA)
The module has 4 D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
RO-CAN-DA8_ISO
CAN module with 8 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 8*D/A (16 bit, galvanically isolated) (Modes U: 0-5V, 0-10V +5V, +10V Modes I: 0-20mA, 4-20mA 0-24mA)
The module has 8 D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
Stepper modules

RO-CAN-STEPPER2
CAN stepper motor control for 2 * stepper motorsInputs: 4 * Switches (2*End/2*Ref) (12-24V)
Outputs: 2 * Stepper
Controller module for two-phase stepper motors. Functionality is given through an extensive driver library. Simple tasks as driving the motor to a certain positon with corresponding slope is very easy.
RO-CAN-O8-R8-STEPPER2
CAN module with 8 * inputs, 8 outputs and stepper motor control for 2 * stepper motorsInputs: 8 * Opto-In
Stepper inputs: 4 * switches (2*End/2*Ref)
(5V-24V)
Outputs: 8 * Relais
Stepper outputs: 2 * Stepper
(1A)
Two-phase stepper motors can be controlled by this module. In addition, it has 8 galvanically isolated inputs and 8 relay outputs. The galvanically isolated CAN interface guarantees a secure connection to the PC.
Digital in- and output modules with time control

PT-100 modules / temperature sensing

RO-CAN-PT100-4
CAN-Module with 4 * PT100 Inputs (galvanically isolated)Inputs: 4 * PT100-Inputs, galvanic isolated (Temperature range form 200°C - 850°C)
Outputs: -
Over the two-or three-wire input a PT100 sensor can be connection. A very accurate measurement is possible because of the integrated 24 bit A/D converter. Depending on the sensor the temperature rainge is from -200°C to 850°C.
RO-CAN-PT100-8
CAN-Module with 8 * PT100 Inputs (galvanically isolated)Inputs: 8 * PT100-Inputs, galvanic isolated (Temperature range form 200°C - 850°C)
Outputs: -
Over the two-or three-wire input a PT100 sensor can be connection. A very accurate measurement is possible because of the integrated 24 bit A/D converter. Depending on the sensor the temperature rainge is from -200°C to 850°C.
Counter modules (PWM / Counter)

RO-ETH-CNT8
Ethernet counter module with 8 input counters and 2 output countersInputs: 8 input counters (32 Bit with max. 20 MHz, various modes)
Outputs: 2 output counters (32 Bit with max. 5 MHz)
8 input counters with 32 Bit and a resolution of max. 20 MHz. The following counter modes are available: counting impulses + counting impulses with "reset when read", distance measurement, number of measurement and PWM measurement.
2 output counters with 32 Bit allowing transmission of pulses.
Incremental modules

RO-ETH-CNT/IGR2
DIN rail Ethernet-Module with inputs for 2 incremental encodersInputs: 2 incremental encoder inputs
Outputs: -
With 2 incremental encoder inputs we start our entry in our digital counter modules. By the connected sensors (incremental encoder) is it possible to record changes in the position (linear) or the angular changes (rotating), the distance and travel direction or the angle change and the direction of rotation. The galvanically isolated Ethernet interface guarantees a safe connection to the pc.
RO-ETH-CNT/IGR4
DIN rail Ethernet-Module with inputs for 4 incremental encodersInputs: 4 incremental encoder inputs
Outputs: -
Due to the increased demand on incremental encoder inputs we hereby offer you the RO-ETH-CNT/IGR4 with 4 incremental encoder inputs. The specifications reflect the RO-ETH-CNT/IGR2 Modul.