CAN - Steuer/Regelungstechnikmodule Übersicht
Anbei finden Sie eine Übersicht unserer Auswahl an Modulen mit CAN-Interface.
Digitale Eingabemodule

RO-CAN-O16
CAN input module with 16 optical decoupled switching inputsInputs: 16 (5V - 24V )
Outputs: -
Beginning with the RO-CAN-O16 having 16 opto-inputs, we start the series of our CAN input-modules. Typical applications are status detection or counter applications. The galvanic isolated CAN interface guarrantees a safe connection to other CAN systems.
RO-CAN-O32
CAN input module with 16 optical decoupled switching inputsInputs: 32 (5V-24V )
Outputs: -
With 32 inputs, these modules can be used in larger installations . The galvanic isolated CAN interface guarrantees a safe connection to other CAN systems.
Digitale Ausgabemodule

RO-CAN-R16
CAN-output module with 16 relay outputsInputs: -
Outputs: 16 * Opto (1A)
16 relays with a maximum switching current of 1A (max.15W) are used for the switching operation on this module. The CAN interface is galvanically isolated.
RO-CAN-R32
CAN-output module with 32 relay outputsInputs: -
Outputs: 32 * Opto (1A)
32 relays with a maximum switch current of 1A (max.15W) are used for the switching operation on this module. The technical data are indentical to the RO-CAN-R16 module.
RO-CAN-R64
CAN-output module with 64 relay outputsInputs: -
Outputs: 64 * relays (1A)
The technical data are indentical to the RO-CAN-R16 module.
RO-CAN-M16
CAN-output module with 16 optocoupler outputsInputs: -
Outputs: 16 * Opto (2A)
These modules are able to switch currents up to 2A by transistors. Electronic switches are more resistant against interfering impulses, but they can only switch DC voltages.
RO-CAN-M32
CAN-output module with 32 optocoupler outputsInputs: -
Outputs: 32 * Opto (2A)
32 transistor outputs with 2A load current features this unit. The technical data are indentical to the RO-CAN-M16 module.
Digitale Ein-/Ausgabemodule

RO-CAN-O16-R16
CAN-in-/output modules with 16 in- and 16 outputs (relay 1A)Inputs: 16 (5V-24V)
Outputs: 16 * relays (1A)
With 16 galvanically isolated inputs and 16 relay outputs, this module is a good choice when inputs and outputs are needed. The galvanic isolated CAN interface guarranties a safe connection to a CAN system.
RO-CAN-O32-R32
CAN-in-/output modules with 32 in- and 32 outputs (relay 1A)Inputs: 32 (5V-24V)
Outputs: 32 * relays (1A)
The technical data are indentical to the RO-CAN-O16-R16 module.
RO-CAN-O64-R64
CAN-in-/output modules with 64 in- and 64 outputs (relay 1A)Inputs: 64 (5V-24V)
Outputs: 64 * relays (1A)
The technical data are indentical to the RO-CAN-O16-R16 module.
RO-CAN-O16-M16
CAN-in-/output modules with 16 in- and 16 outputs (optocoupler 2A)Inputs: 16 (5V-24V)
Outputs: 16*Opto (2A)
With 16 galvanically isolated inputs and 16 optical isolated outputs, this module is a good choice when inputs and outputs are needed. The galvanically isolated CAN interface guarranties a safe connection to other CAN systems.
RO-CAN-O32-M32
CAN-in-/output modules with 32 in- and 32 outputs (optocoupler 2A)Inputs: 32 (5V-24V)
Outputs: 32 * Opto (2A)
The technical data are indentical to the RO-CAN-O16-M16 module.
Analoge Module (ohne galvanischer Trennung) 

RO-CAN-AD16-DA4
CAN 16 * A/D-4 * D/A module with 16 * A/D input channels and 4 * D/A outputsInputs: 16 * A/D channels (16 bit / 4us conversion time) (0..+5V, 0..+10V -5..+5V, -10..+10V (0..20mA optional))
Outputs: 4 * D/A (16 bit, 10 us conversion time) (0..+5V, 0..+10V -5..+5V, -10..+10V)
The module has 16 A/D channels (16 bit / 4 us conversion time) and 4 D/A outputs (16 bit / 10 us conversion time) . The voltage (or optional the current) is converted into a digital value and may e.g. be given back as voltage through a D/A converter. The range of the input and output voltage are separately modifiable through programming.
RO-CAN-AD16
CAN module with 16 * A/D channels (16 bit / 10 us conversion time)Inputs: 16 * A/D channels (16 bit / 4us conversion time) (0..+5V, 0..+10V -5..+5V or -10..+10V (0..20mA optional))
Outputs: -
The module has 16 * A/D channels (16 bit / 4 us conversion time). The voltage (or optional the current) is converted into a digital value and is read out by software through the ethernet interface. The range of the input voltage is modifiable through programming.
RO-CAN-DA4
CAN module with 4 * D/A outputs (16 bit / 10 us conversion time)Inputs: -
Outputs: 4 * D/A (16 bit) (0-5V, 0-10V +5V, +10V)
The module has 4 D/A outputs (16 bit / 10 us conversion time). Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
Analoge Module (mit galvanischer Trennung)

RO-CAN-AD16_ISO
CAN module with 16 * A/D channels, inputs are galvanically isolatedInputs: 16 * A/D channels (16 bit / 4 us conversion time, inputs with common galvanic isolation ) (Unipolar: 0..5V or 0..10V, (0..20mA optional) Bipolar: -5V..+5V or -10V..+10V)
Outputs: -
The module has 16 A/D input-channels (16 bit / 4 us conversion time) . The voltage (or optional the current) is converted into a digital value and is read out by software through the CAN-interface. The range of the input voltage is modifiable through programming. The inputs have a common galvanic isolation.
RO-CAN-AD32_ISO
CAN module with 32 * A/D channels, inputs have common galvanic isolationInputs: 32 * A/D channels (16 bit / 4 us conversion time, inputs with common galvanic isolation ) (Unipolar: 0..5V or 0..10V, (0..20mA optional) Bipolar: -5V..+5V or -10V..+10V)
Outputs: -
The module has 32 * A/D input-channels (16 bit / 4 us conversion time) . The voltage (or optional the current) is converted into a digital value and is read out by software through the USB-interface. The range of the input voltage is modifiable through programming. The inputs have a common galvanic isolation.
RO-CAN-DA2_ISO
CAN module with 2 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 2*D/A (16 bit) (galvanically isolated) (Modes U: 0-5V, 0-10V +5V, +10V Modes I: 0-20mA, 4-20mA 0-24mA)
The module has 2 * D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
RO-CAN-DA4_ISO
CAN module with 4 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 4 * D/A (16 bit, galvanically isolated) (Modes U: 0-5V, 0-10V +5V, +10V Modes I: 0-20mA, 4-20mA 0-24mA)
The module has 4 D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
RO-CAN-DA8_ISO
CAN module with 8 * D/A outputs (16 bit / 10 us conversion time, each output is galvanically isolated)Inputs: -
Outputs: 8*D/A (16 bit, galvanically isolated) (Modes U: 0-5V, 0-10V +5V, +10V Modes I: 0-20mA, 4-20mA 0-24mA)
The module has 8 D/A outputs (16 bit / 10 us conversion time) . Digital values are converted as voltages at the outputs. The range of the output voltage is modifiable through programming.
Schrittmotoren Module

RO-CAN-STEPPER2
CAN stepper motor control for 2 * stepper motorsInputs: 4 * Switches (2*End/2*Ref) (12-24V)
Outputs: 2 * Stepper
Controller module for two-phase stepper motors. Functionality is given through an extensive driver library. Simple tasks as driving the motor to a certain positon with corresponding slope is very easy.